Loading...
HomeMy WebLinkAboutPLAN REVIEW - 02-00051 - Pioneer Farm Equipment9/3/2002 Scott Spaulding Design Intelligence 135 East Main Rexburg, Idaho 83440 Dear Scott, cdy 01AX V/ M 7 STATE OF IDAHO www.ci.rexburaJd.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the Pioneer Equipment drawings that you have provided me and have identified the following discrepancies: 1. The ADA parking requirements require two handicapped spaces when 26 parking spaces are provided. 2. Please obtain a development agreement from the City. See John Millar the Public Works Director regarding this issue. 3. The Sales Room (Equipment and Parts Display) exiting does not meet the diagonal rule for exit separation. Exit signs are required in this room as well as the Parts Storage Room. Please identify on plans. 4. Are all doors between the H-4 occupancy and the rest of the building 1 -hr. rated assemblies? 5. Special inspections are required for high strength bolting and any field welds. Who will be performing these inspections? Please provide us information regarding frequency of inspection and any details associated with these inspections. 6. The Fire Department has reviewed the plans. I have attached a copy of there report. Please provide the necessary information they have requested. Please return two sets of revised plans. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official cc John Millar Chris Huskinson REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box_ 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 8-20-02 Plan Review Review Date: 8-24-02 Building Name: PIONEER EQUIPMENT Building Address: 1500 WEST, REXBURG Stories: ONE Type of Construction: V -N Occupancy Classification: B, M, S-2, H-4 New Construction Floor Area: APPROXIMATELY 18,000 SQUARE FEET 1).Required Fire Flow (Appendix III -A): 3500 GPM/THREE HOURS Comments: FIRE FLOW REDUCED TO 1500 GPM AS THE FACILITY IS TO BE EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: EXISTING, AND PROPOSED ONE NEW ON SITE Fire Hydrant Flows: EXISTING OKAY Fire Flow Test Location: 1500 WEST Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: NONE 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: X Length: X Surface: X Turning Radius: X Grade: X Vehicle Vertical Clearance: X Turn Arounds: X Complete Road Acceptable: YES X 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: IF NOT INSTALLED AND MADE OPERATIONAL PRIOR TO CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: NOT SHOWN Comments: PROVIDE MINIMUM SIZE 2A10BC FIRE EXTINGUISHERS THROUGHOUT BUILDING. 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: YES Type Of System Being Installed: WET Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: YES Comments: 7).Standpipes (Article 10 Section 1004) Required: NO Type Required: Comments: 8).Ventilating Hood And Duct Fire Extinguishing System (Article 10 Section 1006.2) Required: NO Type Being Provided: Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4): Portable Fire Extinguisher Shown (Article 10 section 1006.2.7): Comments: 9).Fire Alarm Systems (Article 10 Section 1007)Required: YES Type Of System Required: Manual: Automatic: X Both: Type Of System Being Provided: Manual: Automatic: Both: Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO Comments: FIRE ALARM SYSTEM REQUIRED AS PER 1997 UFC. PLEASE PROVIDE PLANS THAT INCLUDE ALARM CONTROL AND TROUBLE SIGNALING EQUIPMENT, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS, MANUFACTURERS, MODEL NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS. 10).Other Corrections That Are Required By Special Occupancy Or Conditions: PLEASE ADDRESS ALL ITEMS LISTED. Plans As Submitted Are Acceptable: NO Plans Checked By: CHRIS HUSKINSON Date: 8-24-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X