I have reviewed the Pioneer Equipment drawings that you have provided me and
have identified the following discrepancies:
1. The ADA parking requirements require two handicapped spaces when 26
parking spaces are provided.
2. Please obtain a development agreement from the City. See John Millar the
Public Works Director regarding this issue.
3. The Sales Room (Equipment and Parts Display) exiting does not meet the
diagonal rule for exit separation. Exit signs are required in this room as well
as the Parts Storage Room. Please identify on plans.
4. Are all doors between the H-4 occupancy and the rest of the building 1 -hr.
rated assemblies?
5. Special inspections are required for high strength bolting and any field welds.
Who will be performing these inspections? Please provide us information
regarding frequency of inspection and any details associated with these
inspections.
6. The Fire Department has reviewed the plans. I have attached a copy of there
report. Please provide the necessary information they have requested.
Please return two sets of revised plans. Let me know if I can be of any further
assistance. If you have any questions, please give me a call at 359-3020 ext. 324.
Sincerely,
Val Christensen
Building Official
cc John Millar
Chris Huskinson
REXBURG MADISON COUNTY FIRE DEPARTMENT
P.O. Box_ 280
26 North Center
Rexburg, Idaho 83440
(208) 359-3010
1997 Uniform Fire Code Plan Date: 8-20-02
Plan Review Review Date: 8-24-02
Building Name: PIONEER EQUIPMENT
Building Address: 1500 WEST, REXBURG
Stories: ONE Type of Construction: V -N
Occupancy Classification: B, M, S-2, H-4
New Construction Floor Area: APPROXIMATELY 18,000 SQUARE FEET
1).Required Fire Flow (Appendix III -A): 3500 GPM/THREE HOURS
Comments: FIRE FLOW REDUCED TO 1500 GPM AS THE FACILITY IS TO BE
EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM.
2).Water Supply (Article 9, Section 903) Required: YES
Fire Hydrant Location: EXISTING, AND PROPOSED ONE NEW ON SITE
Fire Hydrant Flows: EXISTING OKAY
Fire Flow Test Location: 1500 WEST
Fire Flow Supplied By: FD
Other Approved Water Source: NONE
Water Supply Acceptable: YES
Fire Hydrant Location Acceptable: YES
Water Supply Comments: NONE
3.)Fire Apparatus Access Roads (Article 9 Section 902)
Required: YES
Acceptable: Width: X Length: X Surface: X
Turning Radius: X Grade: X Vehicle Vertical
Clearance: X Turn Arounds: X
Complete Road Acceptable: YES
X
4).Access Roads and Water Supply, Including Fire Hydrants Are
Required To Be Installed And Made Serviceable Prior To And During
Time Of Construction (Article 9 Section 901.3): YES
Comments: IF NOT INSTALLED AND MADE OPERATIONAL PRIOR TO
CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED.
5),Installation Of Portable Fire Extinguisher (Article 10 Section
1002) Required: YES Location Acceptable: NOT SHOWN
Type Provided Acceptable: NOT SHOWN
Comments: PROVIDE MINIMUM SIZE 2A10BC FIRE EXTINGUISHERS THROUGHOUT
BUILDING.
6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003
Required: YES Type Of System Being Installed: WET
Sprinkler System Monitoring Required (Article 10 Section 1003.3)
Required: YES
Comments:
7).Standpipes (Article 10 Section 1004) Required: NO
Type Required: Comments:
8).Ventilating Hood And Duct Fire Extinguishing System (Article 10
Section 1006.2) Required: NO
Type Being Provided:
Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4):
Portable Fire Extinguisher Shown (Article 10 section 1006.2.7):
Comments:
9).Fire Alarm Systems (Article 10 Section 1007)Required: YES
Type Of System Required: Manual: Automatic: X Both:
Type Of System Being Provided: Manual: Automatic: Both:
Components Of System Shown: Smoke Detectors: Heat Detectors:
Manual Pull Station: Sounding Devices: Visual Devices:
Door Holders: Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO
Comments: FIRE ALARM SYSTEM REQUIRED AS PER 1997 UFC. PLEASE
PROVIDE PLANS THAT INCLUDE ALARM CONTROL AND TROUBLE SIGNALING
EQUIPMENT, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS,
CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS, MANUFACTURERS,
MODEL NUMBERS AND LISTING INFORMATION FOR EQUIPMENT, DEVICES AND
MATERIALS.
10).Other Corrections That Are Required By Special Occupancy Or
Conditions: PLEASE ADDRESS ALL ITEMS LISTED.
Plans As Submitted Are Acceptable: NO
Plans Checked By: CHRIS HUSKINSON Date: 8-24-02
Please furnish comments back to the plan reviewer in the following
manner: Written Comments: X New Plans: X