HomeMy WebLinkAboutPLAN REVIEW - 04-00251 - Parkside Townhomes - Clubhouse10/16/2003 John Dester Georgetown Development 2230 N. University Pkwy Provo, UT 84604 Dear John, cify 012VX1M7-7 STATE OF IDAHO www.ci.rexburqJd.us P,O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the drawings for the Parkside Clubhouse and have identified the following deficiencies: 1. A new site plan was not provided with the drawing. Provide handicapped parking and identify the accessible route from the building to the handicapped spaces and to the pedestrian walks. Identify dimensions from the building to the other buildings and to the property line. 2. The plans must be stamped by a licensed professional as per the 2000 International Building Code (IBC) Section 106.1. Provide structural calculations. 3. Submit manufacturer's certificate of compliance for all components as per IBC Section 1621.3.5. 4. Provide 1 hr. separation between the pool equipment room and the rest of the building. Identify the door to this room as a fire rated door. 5. Identify exit signs. 6. Please provide truss details before framing inspection. 7. Energy calculations are required as per the 2000 International Energy Conservation Code. 8. The energy code compliance documents that you provided me for the Rexburg, Idaho Parkside Clubhouse are for Spanish Fork Utah and were created using an outdated software. Please provide a new checklist using COM Check (available at energycodes.com). Be sure to pick the 2000 IECC and Rexburg, Idaho from the drop down lists. 9. I have attached a copy of the Fire Department review to the back of this document. Please resolve any issues identified by them. Please provide me with 2 new copies of corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official E7 BUq ora ��a /f /f P.O. Bax 280 rc o Q f;/// 0�/ ex l(�QQr y 12 North Center Street CY Q / // Rexburg, Idaho 83440 " n Phone (208) 359.3020 STATE OF IDAHO Fax (208) 359-3022 TgeG1SHE0 , e-mail rexburg@srv.net REXBUJ? G -MADISON COUNTY EMERGENCYSERVICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: UNKNOWN Plan Review Review Date: 10-5-03 Building Name: GEORGETOWN CLUBHOUSE Building Address: UNKNOWN Stories: ONE Type of Construction: V -B Occupancy Classification: A-3 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 4,500 SQUARE FEET 1. Required Fire Flow (Appendix B): 1750 GPM/TWO HOURS Comments: FIRE FLOW MAY BE REDUCED IF STRUCTURE HAS AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: TWO PROPOSED HYDRANTS Fire Hydrant Flows: UNKNOWN Fire Flow Test Location: N/A Fire Flow Supplied By: N/A Other Approved Water Source: NONE Water Supply Acceptable: NO Fire Hydrant Location Acceptable: NO Water Supply Comments: UNKNOWN HYDRANT FLOW, PLEASE PROVIDE ENGINEERS CALCULATION FOR FLOWS. UNCLEAR OF HYDRANT LOCATIONS, PLEASE PROVIDE IMPROVED SITE PLAN. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: NO Complete Road Acceptable: NO Length: NO Surface: OK Comments: NO SITE PLAN INCLUDED WITH BUILDING PLANS. 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: NEED TO PROVIDE MINIMUM OF 2AI0BC EXTINGUISHER IN KITCHEN AREA, AT LEAST TWO OTHERS IN BUILDING WITHIN TRAVEL DISTANCES. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: NOT SHOWN Sprinkler system monitoring (Section 907) required: Comments: NONE 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO Type being provided: Automatic fuel shut-off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: YES Type of system required: Manual: Automatic: X Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, SMOKE DETECTORS ARE REQUIRED IN OCCUPANCY. 10. Other corrections that are required by special occupancy or conditions: Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 10-5-03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X