HomeMy WebLinkAboutPLAN REVIEWS - 03-00083 - 425 & 427 Stegelmeier Ln - New Twinhome9/10/2003 DM Design Dean Martineau 60 West Canyon Road Avon, Utah 84328 Dear Dean, (lily 012(ewlur7 STATE OF IDAHO 1ww.c1.rexbura. d.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg Qci.rexburg.id.us I have reviewed the Loren Stegelmeier Apartment drawings that were provided me and have identified the following discrepancies: 1. Provide a handicapped parking space as per ICC/ANSI A117.1. The space must have an access aisle adjacent to it. 2. The International Building Code (IBC) requires that the lower units be Type "B" handicap adaptable units as per ICC/ANSI Al 17.1. The interior doors, light switches, outlets, appliances, controls any many other items are required to meet ICC/ANSI Al 17.1. 3. Provide a sidewalk to the public way. An accessible route is required from the entrance of the Type `B" units to the public way as per the IBC Section 1104.3. With the current configuration, a ramp is required for accessibility. Please provide details of the ramp, its handrails and guards. 4. Provide details for parking lot drainage. 5. Relocate trash dumpster. Our trash trucks are side loaders and need room to pick up. 6. Identify one hour separation between the units. Call out type "X" sheetrock at party walls and ceilings. Be aware that manufactured joists have different drywall requirements than dimensional lumber. Identify on plans how the fire separation between the upper and lower units is to be accomplished. 7. Be aware that plumbing in the party wall can cause many problems with the integrity of the fire seperation. Plastic pipes can not penetrate the membrane of the 1 -hour firewall unless they are properly constructed to do so. Special fire resistive rings are required or special details that show metal parts entering the membrane and all plastic remaining within the wall. Please show details on plans. 8. Please identify the type and location of the furnace for each unit. 9. Please identify smoke detectors and fire extinguishers in each unit. Smoke detectors are required in both bedrooms and also in the hall outside of the bedrooms. 10. Please provide stair details. Include the rise and run along with guard rail and handrail dimensions. 11. Provide structural calculations as per the 2000 IBC. Include seismic and wind calculations for the Rexburg area. The drawings do not identify foundation bolts or shear walls. Identify spacing of bolts and fastening procedure at shear walls. 12. Who is the Design Professional of Responsible Charge as per IBC Section 106.3.4? If you are that individual, it is your duty for "reviewing and coordinating submittal documents prepared by others". 13. The State of Idaho has adopted the 2000 International Energy Conservation Code (IECC). Please provide energy calculations. 14. The Fire Department has reviewed the plans. I have attached a copy of their report. Please provide the necessary information they have requested. Please return two sets of revised plans and the necessary calculations. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely/ Val Christensen Building Official cc John Millar Chris Huskinson cily 0/ )? (exlmrf STATE OF IDAHO P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@srv.net REXBURG-MADISON COUNTY EMERGENCYSER VICES 26 NORTH CENTER STREET REXB URG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: 8-12-03 Plan Review Review Date: 9-5-03 Building Name: LOREN STEGELMEIER APARTMENTS Building Address: OFF NORTH HIGHWAY 33, REXBURG Stories: TWO Type of Construction: V -B Occupancy Classification: R-2 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 3700 SQUARE FEET 1. Required Fire Flow (Appendix B): 1750 GPM/TWO HOURS Comments: FIRE FLOW REQUIREMENTS MAY BE REDUCED IF AUTOMATIC FIRE SPRINKLER SYSTEM INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: NONE USABLE Fire Hydrant Flows: NONE Fire Flow Test Location: NONE Fire Flow Supplied By: NONE Other Approved Water Source: NONE Water Supply Acceptable: NO Fire Hydrant Location Acceptable: NO Water Supply Comments: NEAREST FIRE HYDRANT OVER Y2 MILE AWAY. PROJECT REQUIRES A MINIMUM OF ONE HYDRANT WITHIN 500 FEET OF PROPOSED STRUCTURE. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: OK Length: OK Surface: UNKNOWN Complete Road Acceptable: NO Comments: UNKNOWN ROAD SURFACE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NO Type provided acceptable: NOT SHOWN Comments: PROVIDE MINIMUM 2A10BC FIRE EXTINGUISHER WITHIN EACH UNIT 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO U Type being provided: Automatic fuel shut-off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Automatic: Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10. Other corrections that are required by special occupancy or conditions: NO Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKTNSON Date: 9-5-03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X