Loading...
HomeMy WebLinkAboutPLAN REVIEWS - 03-00045 - Jack In The Box - Restaurant7/11/2003 Jeff W. Hammond Scott Edwards Architects 1630 SW Morrison St. Suite 210 Portland, Oregon 97205 Dear Jeff, STATE OF IDAHO www.cj.rexburg.jd.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax(208)359-3022 e-mail rexburg@ci.rexburg.id.us I have reviewed the drawings for the Rexburg, Idaho Jack in the -Box and have identified the following deficiencies: 1. The structural calculations use exposure `B" for wind design. I disagree with this exposure. The prevailing winds come out of the West slightly from the South. As you can see by the aerial photo that I have attached to the back of this document, there is nothing but open field and river in the direction that the wind travels. The exposure should be "C". Please have your structural engineer make the necessary changes to the structural calculations and the drawings if required. 2. Please provide a Flood Elevation Certificate as required in the 2000 International Building Code (IBC) Section 1612.5. 3. The soil investigation report identifies a layer of fill mixed with garbage covering the building lot. If you will be over excavating and bringing in structural fill, compaction density tests must be performed by a licensed testing firm Let us know who will be performing these tests so that we can coordinate with them. 4. Submit manufacturer's certificate of compliance for all components as per IBC Section 1-621.3.5. 5. Please provide energy calculations as per the 2000 International Energy Conservation Cade. 6. The Fire Department has reviewed the plans. I have attached a copy of the report. These items need to be addressed before issuance of a building permit. Please let me know if you have any questions. I can be reached during the day at 359-3020 Ext. 324. Sincerely, olam//�K Val Christensen Building Official C.C. John Millar Chris Huskinson RE XBURG-MADISON COUNTY EMERGENCYSERVICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208-359-3006 FAX 2000 International Fire Code Plan Date: JULY 1, 2003 Plan Review Review Date: JULY 7, 2003 Building Name: JACK IN THE BOX Building Address: SECOND EAST AND FOURTH NORTH Stories: ONE Type of Construction: V -B Occupancy Classification: B Existing Floor Area: N/A New Construction Floor Area: 2100 SQUARE FEET 1. Required Fire Flow (Appendix B): 1500 GPM FOR TWO HOURS Comments: NONE 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: O'DELLS FURNITURE/STONERIDEG MOTOR SPORTS Fire Hydrant Flows: OKAY Fire Flow Test Location: AS ABOVE Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: PLANS INDICATE EXISTING BUILDING ADJACENT TO PROPSED STRUCTURE TO BE PROVIDED WITH ADDITIONAL FIRE HYDRANT PROTECTION.....ARE THESE HYDRANTS GOING TO BE INSTALLED NOW OR AT A LATER DATE? PLEASE ADDRESS PRIOR TO CONSTRUCTION. 3, Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: OK Complete Road Acceptable: YES Comments: NONE Length: OK Surface: OK 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: U/K Type provided acceptable: YES Comments: PROVIDE A MINIMUM OF 2AIOBC IN PUBLIC AREA AND A 401KB EXTINGUISHER IN KITCHEN AREA. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: YES Type being provided: ANSUL Automatic fuel shut-off required: YES Portable fire extinguisher shown: YES Comments: ANSUL SYSTEM SHALL BE FULLY TESTED IN PRESENCE OF FIRE INSPECTOR BEFORE OCCUPANCY. 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Automatic: Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10. Other corrections that are required by special occupancy or conditions: NONE Plans as submitted are acceptable: YES Plans checked by: CHRIS HUSKINSON Date: 7-07-03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: