HomeMy WebLinkAboutPLAN REVIEW - 02-00077 - Cougar Court Apartments - 7 Buildings (149 Units)4/24/2002 Brent Hilton Hilton Architects 6895 South 900 East Salt Lake City, UT 84047 Dear Brent, edy ollexlury STATE OF IDAHO www.cj.rexburgJd.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg@d.rexburg.id.us I have reviewed the plans for the Cougar Apartments and have identified the following discrepancies or questions: 1. Please provide dimensions on parking plan (site plan). The parallel spaces along the laundry are too short. Parallel spaces should be 22' long or longer. You need 2 spaces per dwelling unit. It appears that you are 7 spaces short. 2. The ADA requires that one of your handicapped parking spaces be a van accessible space. The aisle adjacent to a van accessible space is required to be 96" wide. The other handicapped spaces require a 60' aisle. Please identify these aisles and dimensions on parking plan. 3. Compact parking spaces are to be signed. Please identify compact spaces and signage on plans. 4. Some of the trash dumpsters are located in parking lot corners. Our trash trucks are side loading and will not be able to access these dumpsters. 5. Please identify privacy fencing where parking lots border other properties. 6. All units on the lower floor must be type "A" or type "B" handicapped units. Please identify the location of all handicapped units on the site plan. 7. Please identify location(s) of 2 hr. fire-wall(s). 8. Please provide literature on stucco for 1 -hr rating. 9. The footings in the entry do not have the required 36" of ground cover for frost protection. 10. Please provide truss details prior to framing inspection. 11. Sheet S I calls out for Special Inspections on concrete and structural field welding. Please let us know who will be performing these inspections as soon as possible. Section 1701.1 of the 1997 Uniform Building Code (UBC) requires that the special inspectors be employed by the owner or the engineer or architect of record acting as the owner's agent. Let us know if you will be employing the special inspectors. The Contractor is not allowed to perform this function. 12. I have attached a copy of the Fire Department review top the back of this document. Please provide me with 2 new stamped copies of the corrected plans. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely, Val Christensen Building Official C.C. John Millar Chris Huskinson REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 8-02 Plan Review Review Date: 9-12-02 Building Name: COURGAR APARTMENTS Building Address: WESTATES SUBDIVISION Stories: 3 Type of Construction: V -I Occupancy Classification: R-1 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 21,000 SQ. FEET 1).Required Fire Flow (Appendix III -A): 4,000 GPM/FOUR HOURS Comments: AN APPROVED AUTOMATIC SPRINKLER SYSTEM IS REQUIRED FOR ALL BUILDINGS IN THIS PROJECT. (AS OF THIS DATE NO PLANS HAVE BEEN SUBMITTED FOR THE LAUNDRY FACILITY, HENCE IT IS UNKNOWN THE STATUS OF THAT BUILDING). WITH A SPRINKLER SYSTEM THE MINIMUM FIRE FLOW REQUIRED IS 1500 GPM/2 HOURS. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: OKAY Fire Hydrant Flows: UNKNOWN Fire Flow Test Location: NONE Fire Flow Supplied By: N/A Other Approved Water Source: NONE Water Supply Acceptable: YES, SEE COMMENTS Fire Hydrant Location Acceptable: YES Water Supply Comments: PLEASE PROVIDE AN ESTIMATED FIRE FLOW FROM EACH HYDRANT PRIOR TO APPROVAL 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: YES Length: YES Surface: YES Turning Radius: YES Grade: OK Vehicle Vertical: UNKNONW Clearance: OK Turn Arounds: YES Complete Road Acceptable: SEE COMMENTS BELOW Comments: ALL AREAS ADJACENT TO BUILDINGS NOT MARKED FOR PARKING SHALL BE SIGN � NO PARKING FIRE LANE, IN ADDITION TO HAVING THE ---__ CURB --PAINTED- RED—AND—MAIN-T-AI-NED. --- --- -- - - --------------------_----- 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: MINIMUM OF ONE 2A10BC EXTINGUISHER PER UNIT Comments: NONE 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: YES Type Of System Being Installed: UNKNOWN Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: YES Comments: 7).Standpipes (Article 10 Section 1004) Required: NO Type Required: Comments: 8).Fire Alarm Systems (Article 10 Section 1007)Required: YES Type Of System Required: Manual: Automatic: Both: YES Type Of System Being Provided: Manual: Automatic: UNKNOWN Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, PLEASE INDICATE SMOKE DETECTORS AND THEIR PLACEMENT. SEE COMMENTS BELOW 10).Other Corrections That Are Required By Special Occupancy Or Conditions: FIRE ALARM SYSTEM: PLEASE SUBMIT SUBMITTALS OF ALARM CONTROL AND TROUBLE SIGNALING EQUIPMENT, ANNUNCIATION, POWER CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE DROP CALCULATIONS-,- _MANIIFACTURERS—MODEL—NUMBERS; - - AND--LIS-T-ING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS AND INTERFACE CONNECTIONS. ADA UNITS SHALL HAVE ALL HORN/STROBE UNITS. FINAL PLANS: MOST CURRENT PLANS DO NOT MATCH SITE PLAN AS APPROVED BY P a Z, PLEASE RECTIFY. Plans As Submitted Are Acceptable: NO Plans Checked By: CHRIS HUS&INSON Date: 9-12-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: YES New Plans: YES