HomeMy WebLinkAboutTHE COTTAGES APARTMENTS - LETTERS & DOCSm/ .ylL���DQQD°QJl • 0 STATE OF IDAHO NILE L BME MAY R ROSE BAGL .. o eRR RICHARD HORNER. TRE RCA NOTICE TO: Steve Clark 725 South 5000 West Rexburg, ID 83440 12 NORTH CENTER ST. PHONE (208) 359-3020 REXBURG, IDAHO 83440 Due to the violations of the UBC, UPC, NFC, NEC, and state and federal regulations governing natural gas usage noted in the inspections made on or about October 15, 1990, you are hereby notified that you are not entitled to an occupancy permit for "The Cottages Apartments" located at 151 South First East, Rexburg, Idaho. Pursuant to the UBC, Sections 205 and 202(e), you are notified that the City of Rexburg has never granted you an occupancy permit for the fifteen apartments and hereby orders occupancy of the premises discontinued until all applicable provisions of the UBC, UPC, NFC, NEC and federal and state regulations governing natural gas usage are fully and completely satisfied. Anyone desiring or continuing to live in these apartments shall do so at their own risk. DATED this 17th day of October, 1990. Building Inspector aI Mayor a t9G'r�CRN'�d�� Rexburg c � D �� - . g , l OFIDAHO STATE JOHN C. PORTER 4A, ROSE BAGLEY. os:Rn RICHARD HORNER. MB AER Steve Clark Route 111 Box 230A Rexburg, Idaho 83440 Dear Mr. Clark: 12 NORTH CENTER ST PHONE MOW 3593020 RVOURG. IDAHO 03x40 October 15, 1986 Chuck Frost, Chairman of Planning & Zoning, Nile Brown, Building Inspector, and Gordon Tychsen, Fire Inspector have recently inspected your parking area at your apartments on South 1st East. Their recommendations were: (1) You must have a 20 foot Driveway which is kept clear at all times for a Fire Lane; (2) You must warn your students that they can't park on the street or in your driveway. They also should not block any of the neighbor's driveways. On November 1 their cars will be towed away if they park on the street overnight. (3) You will not be allowed to build anymore apartments until you come to the Planning & Zoning with a Plot Plan and show adequate parking for your apartments. If you would like to discuss this further please attend the Planning & Zoning meeting on October 22, 1986, at 7:30 P. M. Sinc�rely, i vr� 3 n C Porter, Mayor rb RIC PAGE Director of Housing Steve Clarke The Cottages Rt. 1 Box 230 A Rexburg, ID 83440 September 5, 1990 I A CENTURY OF COMMITMENT SUMMITS YET TO CLIMB 1888-1788 Dear Steve: 0 It is our understanding that most of the young women who contracted with you for the newly constructed units at The Cottages have moved into unfinished apartments, and that although you are continuing to make finishing touches and final installations of appliances and fixtures, there is still no certificate of occupancy nor has the complex passed a final inspection to apply for that certificate. I need to inform you that the new portion of The Cottages is not approved to house Ricks College students until the building inspections have been made and, approved by the appropriate building inspectors and the certificate of occupancy from the City of Rexburg has been received. We are concerned about safety of the young women there who must contend with open breaker boxes, bare wires, power tools, and construction mess that could be a hazard. In addition to our safety concerns, we are concerned about the comfort and convenience of the students who must make due with some appliances, plumbing and electrical fixtures which are unusable; doors which are missing; telephones which won't be installed until October or November, somewhat limited parking space, etc. None of these students were informed by you of the unfinished conditions as we repuested of you two weeks ago. Several students and their parents were excited to come to "the most expensive unit in town" expecting to have things spit and polished. Instead, many have spent countless hours working to get their apartments cleaned up and prepared for occupancy. Some have articulated their frustration at the apparent discrepancy between the rental price and the product which is delivered by saying that with The Cottages you "expect the ritz and get the pits." Others have simply bailed out of the situation and have gone somewhere else to live. As a result, we are now getting requests for abatement of rent or rent refunds to help compensate them for their inconvenience. I would like to schedule a meeting with you at your convenience to discuss this matter and would offer my services to mediate an adequate solution between you and a small group of student representatives. Housing Office / Ricks College / Rexburg, Idaho 83440 / (208) 356-1045 Steve, I know that this situation is a very difficult one for you, but the students and parents also have some legitimate concerns and frustrations which must be addressed. I would like to help them look at the situation realistically, and in light of the financial constraints you are under right now, but they must be addressed honestly and fairly. We have communicated with the City and we have determined that the certificate of occupancy should be within reach by the end of November. If the certificate is not received by then, we will not leave The Cottages on the approved list to be printed in December, 1990 for the 1991-92 school year. The leniency here is in deference to the young women involved and the lack of other suitable alternatives for housing at the present time. However, without being approved, we will not allow the Cottages to house Ricks College students next summer or thereafter. Please communicate with me regarding these concerns and let's get together as soon as possible to review alternatives to solving these problems. After you and I meet we will inform the tenants of our concerns and possible solutions. Thanks for your help and understanding in these issues. Sincerely, Ric Page Director of Housing cc: ,Mayor Nile Boyle Mack Shirley, Vice President of Student Life Jerry Price, Assistant Vice President of Student Life Michael Orme, Ricks College Legal Counsel Cheryl Bird, President--Off-Campus Householders' Association cil /STATE OF IDAHO NILE L BOYLE M/.YOR ROSE BAGLEY. CLERK RICHARD HORNER. TREASURER Steve Clark 625 South 5000 West Rexburg, Idaho 83440 RE: The Cottage Apartments Steve Clark, 12 NORTH CENTER ST. PHONE 12081 3593020 REXBURG. IDAHO 83440 August 20, 1990 A Certificate of Occupancy is required from the Building Department of the City of Rexburg to the owner of apartments before any student can be placed in any apartments. In order to receive the Certificate of Occupancy, all parking areas must be completed. This includes drainage of lots, stairways, blacktopping and marking. All exterior of buildings must also be completed including stairways and decking. Then each apartment, as the interior is completed, can receive the Certificate of Occupancy. The general landscaping can be completed after students are living in the complex, but before bad weather arrives. The Building Department also must have the engineer's design and written approval of the change of decking and cantlevered section of front of building. Sincerely, Glenn Bean CC; Ricks College Off Campus Housing Department, Glenn Bean, and Mayor Boyle. bh . _ cay m/ �.d (L e �C l ([dTl y • 0 0 STATE OF IDAHO 12 NORTH CENTER ST. PHONE 12081 3583020 NILE L BOYLE REX BURG, IDAHO 83440 WMR ROSE BAGLEY. a IW RICHARD HORNER. TREASURER July 2, 1990 Steve Clark Cottage Apartments Rexburg, Idaho 83440 Dear Mr Clark: I have visited the job site of "The Cottage" Apartments, and with almost every visit I have had to correct or instruct the workman on work that was being done incorrectly or in a condition that indicated poor working practices. For example: walls that weren't plumb, headers that weren't according to code, and foundation walls not plumb straight, or conforming to the existing foundation walls, just to mention a few. The supervision on the job is not up to standard and in view of the work being performed with this supervision, I recommend that they get one man capable and experienced enough to handle this situation or we will have to close the project down. If this man can be found and placed in the position to carry on this work similar to other contractors in Rexburg, we should set a future date for this event and if it doesn't take place in this time the project will be shut down. There has been several changes from the original plan, and the owner is required to notify the building officials of this change for permission to change and present a detailed plan of this change with specifications. Signed, Glen Bean, Building Inspector 40 ys `? fi�G'rO CBNT"�� 6, j 4ntl D. Hancock R C /�� Rexburg City Attorney 30 South 2nd West P. 0. Box 427 Rexburg, Idaho 83440 (208) 356-5493 IN THE DISTRICT COURT OF THE SEVENTH JUDICIAL DISTRICT OF THE STATE OF IDAHO IN AND FOR THE COUNTY OF MADISON STATE OF IDAHO, Plaintiff, ) Case No. VS. ) SUMMONS STEVEN CLARK, ) Defendant. ) THE STATE OF IDAHO SENDS GREETING TO STEVEN CLARK, the above named defendant. YOU ARE HEREBY NOTIFIED, that a complaint upon oath has been filed against you in the Magistrate's Division of the District in and for the County of Madison by a State of Idaho Electrical Division Supervisor, Chris Martin, charging that you have committed the crime of violating certain provisions of the National Electrical Code as adopted by Rexburg City Ordinance No. 702. You are hereby directed to appear in the above court and plead to said complaint on Monday, the 5th day of November, 1990, at 1:30 o'clock P.M. WITNESS My hand and the seal of said court this 29th day of October, 1990. Magistrate ACKNOWLEDGMENT OF SERVICE I HEREBY ACKNOWLEDGE SERVICE of the above summons and complaint and promise to appear at said court on the date and time written to answer to the charge indicated above and understand that failure to appear as directed may result in the issuance of a warrant for my arrest. ;UMMONS -1- Defendant Rexburg d . ly 0 Wex /, rF STATE OFIDAHO JOHN C PORTER M1YCR ROSE BAGLEY. Q w RICHARD HORNER. MEA UREA Steve Clark Route #1 Box 230A Rexburg, Idaho 83440 Dear Mr. Clark: 12 NORTH CENTER ST PHONE (208) 3593020 REXBURG. IDAHO 83440 October 15, 1986 Chuck Frost, Chairman of Planning & Zoning, Nile Brown, Building Inspector, and Gordon Tychsen, Fire Inspector have recently inspected your parking area at your apartments on South 1st East. Their recommendations were: (1) You must have a 20 foot Driveway which is kept clear at all times for a Fire Lane; (2) You must warn your students that they can't park on the street or in your driveway. They also should not block any of the neighbor's driveways. On November 1 their cars will be towed away if they park on the street overnight. (3) You will not be allowed to build anymore apartments until you come to the Planning & Zoning with a Plot Plan and show adequate parking for your apartments. If you would like to discuss this further please attend the Planning & Zoning meeting on October 22, 1986, at 7:30 P. M. Sind rely, n C Porter, Mayor rb NILE L. BOYLE �wraR ROSE BAGLEY, CLERK RICHARD HORNER, TRE Ws R August 24, 1992 STATE OF IDAHO 12 NORTH CENTER STREET RE%BURG, IDAHO 83440 PHONE (208) 359-3020 Steve Clark Cottage Apartments 151 South 1st East Rexburg, Idaho 83440 Dear Mr. Clark, I have been asked by Farrell Davidson, Public Works Director, to inform you that the trench across your sidewalk in front of your apartments, that was used for drainage, has not been repaired to the correct grading requirements and presents a safety factor. It will have to be changed from the sidewalk to the curb to meet the grading requirements. We must insist this be done before September 15, 1992. Sincerely, (� Rose Baglry, Cit" y Clerk City of Rexburg jw AND INDUSTRIAL SERVICES October 19. 1990 TO: Gary L. Malmen Electrical Division Administrator FROM: Terry L. Coumerilh Electrical Licensing/Compliance SUBJECT: OVERVIEW OF INSPECTION OF "THE COTTAGES" REQUESTED BY THE CITY OF REXBURG On Tuesday, October 17, 1990, Mayor Nile Wiley of the City of Rexburg and Director of Public Works Farrel Davidson requested the assistance of the Electrical Division in assessing the electrical "condition" of a complex of apartments known as "The Cottages" located at 151 South First East. The units in question are indicated to be five (5) triplex apartments in a three story vertical arrangement. Because of the unavailability of Mr. Davidson on Wednesday, the inspection was scheduled for Thursday, October 19, 1990. On said date an inspection team consisting of Inspectors Dan Fadness, Roy Frisk and myself met with Mr. Davidson and conducted an electrical inspection of those items that were accessible and not requiring removal of building finish or that were not rendered inaccessible because of the occupants (comprised of approximately ninety (90) students and their associated furnishings, baggage, waterbeds, etc.). Some items (such as service panels and ground fault interrupter testing) were inspected in each and every apartment and other items were looked at on a random basis once a common deficiency was noted. Some items were not identified on the written list against each specific apartment once it became apparent that all apartments suffered a similar deficiency (e.g., over-lamping of fixtures in direct violation of warning on fixtures). It should be noted that in endeavoring to make this inspection, the team attempted to be a thorough as possible within the constraints imposed by occupation of the apartments without causing excessive inconvenience or time delays for the occupants or others. It has been noted previously that as redundancy of violations became apparent many were not itemized by the individual inspection team member against an individual apartment. eAf VO 18V0•C N EN NIA I. 1000 EQUAL OPPORTUNITY EMPLOYER • "loop (208) 334-:3950 Area Offices: U,01 202 AWOn :venue suite 201. Coeur d'Alene. ID 53814 (208) 7655570 • • • • • - 307 F.aSI LCWIS. P.O. 130% 4963. POCalellO. ID 83205.49r� 208) 233-4678 DEPARTMENT OF LABOR Gary H. Gould, Director AND INDUSTRIAL SERVICES October 19. 1990 TO: Gary L. Malmen Electrical Division Administrator FROM: Terry L. Coumerilh Electrical Licensing/Compliance SUBJECT: OVERVIEW OF INSPECTION OF "THE COTTAGES" REQUESTED BY THE CITY OF REXBURG On Tuesday, October 17, 1990, Mayor Nile Wiley of the City of Rexburg and Director of Public Works Farrel Davidson requested the assistance of the Electrical Division in assessing the electrical "condition" of a complex of apartments known as "The Cottages" located at 151 South First East. The units in question are indicated to be five (5) triplex apartments in a three story vertical arrangement. Because of the unavailability of Mr. Davidson on Wednesday, the inspection was scheduled for Thursday, October 19, 1990. On said date an inspection team consisting of Inspectors Dan Fadness, Roy Frisk and myself met with Mr. Davidson and conducted an electrical inspection of those items that were accessible and not requiring removal of building finish or that were not rendered inaccessible because of the occupants (comprised of approximately ninety (90) students and their associated furnishings, baggage, waterbeds, etc.). Some items (such as service panels and ground fault interrupter testing) were inspected in each and every apartment and other items were looked at on a random basis once a common deficiency was noted. Some items were not identified on the written list against each specific apartment once it became apparent that all apartments suffered a similar deficiency (e.g., over-lamping of fixtures in direct violation of warning on fixtures). It should be noted that in endeavoring to make this inspection, the team attempted to be a thorough as possible within the constraints imposed by occupation of the apartments without causing excessive inconvenience or time delays for the occupants or others. It has been noted previously that as redundancy of violations became apparent many were not itemized by the individual inspection team member against an individual apartment. eAf VO 18V0•C N EN NIA I. 1000 EQUAL OPPORTUNITY EMPLOYER October 19, 1990 Memo: "The Cottages" Inspection Page -2- The appropriate corrective actions would require not only addressing the specific itemized violation as stated in the report, but competent licensed electrical personnel would by necessity have to inspect each and every location where similar discrepancies could be found. For example: 1. Spot checks show bath fans are not properly grounded due to misapplication or non-use of "ground clips". Ground clips are normally considered only slightly more complex than a screw, but it is obvious that because of the spot checks made all bath fans should be checked. 2. It is apparent, for example,.that a mechanical connector has not been used at numerous splice locations. Some splices were made with the proper connectors. Only investigation of each and every outlet, receptacle switch, light outlet, etc. would determine the actual numbers of this specific violation. 3. None of the circuit breaker panel directories were filled out. 4. Some individual panels exhibited evidence of "professional" involvement; i.e., separation of grounds and neutrals, proper bonding, neat workmanlike terminations, etc. Most panels showed'a distinct lack of expertise or knowledge of electrical installations. Violations in panels create hazards ranging from electrical shock potential to, as in apartment 9C, the inability of a branch circuit breaker to trip because of unterminated feeder ground. 5. Integrity of the "firewall" system is much in doubt as observable penetrations have not been sealed with appropriate firestop. Page 1 of 3 EF -411 State of Idaho 2118/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OIMER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Service Eauipment LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 fffHlNf if If fH lffffNHNH1HNf ffffNlHHffHNftllH Hlff NfHf 1fHflNHffHff Nflfff/HNNINfHHfNf HH1Hf f Hfff The etectrieal instatlation described above hes been inspected and was found to be essentially in accord with the min(nn mNlrements of the National ELectrical Code except as follows. NEC REFERENCE I FINDINGS I Service equipment consists of four (4) general electric jthree gang meter -disconnects cat. At TMM4312R with 100- 1 I ampere circuit breakers plus one (1) ITE brand four gang i I meter -disconnects with 100 ampere circuit breakers install- s I ed. All units are rated 400 -ampere service mains I 1 250-94 I Main grounding electrode conductors appear undersized as I i they appear to be #6 copper or #4 copper conductor, The I i National Electrical Code would reauire 1/0 copper based on I I the 400 -ampere mains rating. I 110-12 1 All bonding straps appear loose in the service panel and I sheet metal screws have been substituted for the factory I I machine screws. I ELECTRICAL INSPECTOR DATE ka Page 2 of 3 EF•411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 west ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Service Equipment LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 H1HtHf 1Hf N1ff11fNfH1HfH1N1fNN11Hf HNf1NNtH1Hf NH1f 1HHHflflNfff111111111111fff1Nf Hf1HHfHfflf 1NHf The electrical instatlation described above has been inspected and Was found to be essentially in accord With the minfaam requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS 90-4 j The supplemental grounding electrode (ground rod) and con- i I ductor termination were unaccessible for inspection. The I number, size and routing of grounding conductors indicated I a lack of understanding of proper grounding methods by the jinstaller. 90-4 j The use of an anti-oxygent on the aluminum feeder conductors ranged from non-existent on some conductors to over (sloppy) I I application on others. 110-3(b) j Square -D brand circuit breakers were evident in meter bases 1 9 and 10 in violation of equipment listing. I 90-4 I All enclosures require final fastener installation. 373-5(c) ( ) In each of the service equipment combination meter-discon- i nect enclosures, the individual SER type feeder cables were I not individually secured to the enclosure with the proper ELECTRICAL INSPECTOR DATE ka EF•411 State of Idaho 2/18/88R Department of Later and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 .South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Service Equipment Page 3 of 3 LOCATION OF BUILDING: 151 South First East Rexbur¢. Idaho 83440 f Hff111ffffHN11HfMHH1f1H1HH111fN111f1HffNNlff H1f Hffliff f HNf1HH1fINHNtHH1HNf1ffH NffHHHH1HIN The electrical installation described above has bean inspected and was found to be essentially In accord with the minion requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS _ I i connector and bushing, but rather were fed through a single I I knock -out with a chase nipple. Therefore the cables are I I not secured to,the enclosure but are capable of movement I and the transmission of stress to the terminations at the i I circuit breakers, etc. 336-10(b) ( ) Romex shall not be exposed on exterior of structure (behind I I gas pipe) to join mismatched walls I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division RECUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 {Nest ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 6A LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 •++++rrr++++rr++rrrrr+rr+rrr:rrrrrrerrrrr+r++r+rrrrr»r++»rre+rrrrrrrrrrr:rr++rrr++++rrr:rrr+r:rerr+�++++rrrrre+++++++++rrrr The electrical installation described above has been inspected and was found to be essentially in accord with the minimus requirements of the National Electrical Code extent as follows. NEC REFERENCE I FINDINGS 220-4 I (Only one small appliance circuit in kitchen. 110-22 I (Service equipment and circuit breaker panels shall be clear- ly labelled. 110-13 I (Doorbell transformer shall be properly mounted not hanging I I from wires. 90-4 jPanel cover does not cover opening in sheetrock. 410-56 d ( )(e) (Faceplate is needed on range outlet. 210-52 I (Outlets in back bedroom are inoperative. 250-61(b) ( ) (The neutral shall not be used to ground equipment on the load I I side of the service disconnect (separate neutrals). 110-12 i (Electrical equipment shall be installed in workmanlike man -- I ner. ELECTRICAL INSPECTOR its DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrlsl Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER$ CONTRACTORt NAME$ Stephen E. Clark NANEt Unknown ADDRESS$ 625 South 5000 Nest ADDRESSt Rexburg, Idaho 83440 PERMIT NUMBER$ TYPE OF BUILDING: _ Apartment 7A LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 HHiHNHfHIfiNfNtH1f1f1HfHHHIfNffflfHNNNN1HNffffHHfffffflHNHfHffNNfHfHffftflnfHfflHfff HHf N The eteotrical installation described above has been inspected and was found to be essentially in accord with the minima requirements of the National Electrical Code exeeot as follows. NEC REFERENCE I 'FINDINGS 410-56(d)(e) I iThe range receptacle shall have a faceplate installed. 110-13 jThe doorbell transformer shall be properly mounted. 370-10 I iBoxes shall be flush or recessed not more than j inch. 110-3b IRomex is too close to boiler flue pipe. 370-10 jSquare holes were cut in ceiling for round light boxes. 373-4 i (Unused opening in panel cover shall be filled. 410-18(a) j Kitchen light fixture shall be properly grounded. _110-13 j Kitchen light fixture shall be properly installed. 210-7 !Receptacles shall be of the grounding type (see by sink in I I bedroom). 370-17(c) I Outlet boxes shall not be sole support of paddle fans I I (socket loose). 250-61(b) t I The neutral shall not be used to ground equipment on the load I I side of the service disconnect. 110-12 Electrical installations shall be done in a workmanlike manner. LECTRICAL INSPECTOR DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industriat Services Electricai Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 ADDRESS: PERMIT NUMBER: TYPE OF BUILDING:Apartment 8A LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 Hf H1f HbN NNf RNf if f11Nf 11HNHf f fMfNff NRHIHRNNf f ff Nf f fffMef ff f Rf 1f Nf f f of f fN Hfff ff f fHHff1l11HRHHNR1f The electrical installation described above has been inspected and was found to be essentlatly in accord with the minima requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS I 110-13 1 Doorbell transformer shall be properly installed. 370-10 I Bath fixture needs to be properly installed and sheetrock I I repaired. 410-4(a) j Northeast bathroom fixture (Tracy's room) not approved for I I a damp location. I 410-56(d)(e)I Range outlet needs faceplate. 370-10 j Range outlet box shall be flush (recessed now) 370-17(c) ( ) I Plastic box on paddle fan. I 90-4 1 No doorbell button. 250-61(b) ( ) I The neutral shall not be used for grounding on load side of I I service disconnect. 110-12 j Electrical equipment shall be installed in a workmanlike I manner. I ELECTRICAL INSPECTOR DATE ka EF -411 State of Idaho 2118/88R Department of Labor and Industrial Services Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark RAKE: Unknown ADDRESS- 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 9A LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 f RR111f /f iH HfRNf f NHff IfMffNH1H1NN1fRRHNfflff\fH\f HHHf 1HRHfRf\fN HRfR\NHH1fIf1Hf 1fH1fb11HHlfffffff The electrical installation described above has leen inspected and was found to be essentially in accord with the minimm requirements of the National_ Electrical Code except as follows. NEC REFERENCE I FINDINGS I 410-15(a) 1 Outside porch light not secured to box. I 220-4 1 Kitchen outlets on bathroom circuits. 370-10 j Outlet boxes shall be flush or recessed not more than 4 inch. 410-4(a) ( ) 1 Bathroom fixturds not rated for damp location. I 90-4 1 Kitchen light fixture broken. I 373-4 I Panel needs knock out seals. I 110-3(b) 1 Romex against boiler flue between floors. I 210-52 1 Missing receptacles shall be installed. I 410-18 1 Kitchen florescent fixture shall be grounded. I 250-61(b) I Neutrals and equipment grounds not separated in subpanels I 110-12 1 Electrical installations shall be in workmanlike manner. ELECTRICAL INSPECTOR ka DATE EF -411 2/18/88R PROPERTY OWNER: NAME: Stephen E. Clark State of Idaho Department of Labor and Industrial Services Electrical Division ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 REQUESTED INSPECTION FINDINGS CONTRACTOR: NAME: Unknown ADDRESS: PERMIT NUMBER: TYPE OF BUILDING: Apartment 10A LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 •f 1Nf f IfH1f fNiH1Nf f N1Niif11ff1NfNN1f 1fNHb1Nf f1NHf 1bf f fRMN1f ff 1RtN1f H11H1M1NN/NYIfHH1fH11f f b1f f1 The electrical installation described above has been inspected and was found to be essentially in accord with the minimae recufrements of_ the National_ Electrical Code except as follows. NEC REFERENCE I FINDINGS 1 373-4 1 Unused openings in circuit breaker panel 1 T T hp, filled 1 373-5(c) 1 Romex shall be secured to panel (just run through hole no I I romex connector). b I 336-10 p ( ) 1 Exposed romex at doorbell transformer. I 250-61(b) 1 Neutrals shall be separate from grounds in subpanel 110-13 j Doorbell transformer not properly installed. 250-114 I Equipment grounds shall be spliced with mechanical connectors I I (not .just twisted). 110-12 1 Electrical equipment shall be installed in a neat workman- like manner. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY MMIER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS2 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 6B LOCATION OF BUILDING: 151_ South First East Rexburg. Idaho 83440 ♦ •»u��r���* ae��:y'rt�»�m��eee�t��������� �e��� �� e»kt���� u��t�+� �f.e ��e� e� �� Stu �� �����+ti��»t������ ��:����Rnu te+.���R� The etectrical Instatlatl on described above has been inspected and was found to be essentially in accord with the minimus requirements of the National El ectriceI. Code except as fotlows. NEC REFERENCE I FINDINGS I 110-13 1 Doorbell transformer shall be properly mounted I 90-4 1 Light by sink inoperative I 410-4(a) I Bath fixtures are marginally out of damp area I 210-52 1 Receptacle missing in southeast bathroom 110-12 j All electrical installations shall be in a workmanlike I I manner. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and IndustriaL Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 west ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 7B LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 HH#fHlfftlfHfYHHff#Rf Yf#fff#ff HllHHbb#tlff#Hff 1f11ff1f11HlRHHtlfHlffffflf lR/ftVllfffff Vf#lIH HRfHH#H111H The electrical installation described above has been Inspected and Was found to be essentially in accord With the minimum requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS 110-13 1 Doorbell transformer not properly mounted. 410-56(d)(e)j Range outlet needs face plate. 110-22 1 Panel shall be labelled. 110-3(b) i Lighting fixtures shall not be over-lamped (exceeds rating). I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 PERMIT NUMBER: ADDRESS: TYPE OF BUILDING: Apartment 8B LOCATION OF BUILDING: 151 South First East Rexbure. Idaho 83440 f tlfHflf I###f#1f1HN#1RllH fff #Rf 1Hf RNH NR#HH#INH b#NN#Hf ##Iflrlf R####fff#1##fff N1Hf fRR###M R1f1f #f#N H#tl HfH The electrical installation described above has been inspected and was found to be essentially in accord with the minium requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS I 110-13 1 Doorbell transformer not properly installed. I 90-4 I Kitchen light needs cover. I 110-12 I Wires being pinched under light. I 210-52 I Unterminated bare conductors in panel. I 110-22 1 Panel needs labelling. 410-56(d)(e)j Range outlet needs faceplate. 110-12 1 Electrical equipment shall be installed in a workmanlike manner. ELECTRICAL INSPECTOR DATE ka EF -411 2/18/88R PROPERTY OWNER: NAME: Stephen E. Clark State of Idaho Department of Labor and Industrial services Electrical Division ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 REQUESTED INSPECTION FINDINGS CONTRACTOR: ADDRESS: PERMIT NUMBER: TYPE OF BUILDING: Apartment 9B LOCATION OF BUILDING: 1.51 South First East Rexbure. Idaho 83440 HfH1Hf Hf#f ifffffifllf f##H#1HffHlH#fHffH#Hf 1HlH HRflfHlfllfH#Hf1Hf fHifHHH1H#H HfY1H#H#H#Ht1f f ff fHf The electrical installation described above has been inspected and was found to be essentially in accord with the minfmA requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 220-4 I Kitchen and bath GFIs shall not be on the same circuit 110-13 i Doorbell transformer not properly installed 250-61(b) I I Panel grounds and neutrals shall be separated 373-4 j Panel shall not'have open holes. 379-5(c) ( ) I Romex shall be secured to panel with a connector. 370-15(b) j Round boxes with square holes in sheetrock shall be patched. _ 336-10(b) I Romex at dishwasher shall be protected (it is exposed) 110-22 I Panel shall be labelled. I ELECTRICAL INSPECTOR ke DATE EF•411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR - NAME. Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS - Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 10B LOCATION OF BUILDING- 151 South First East _ Rexburg, Idaho _ 83440 Hf 11f1H HYf1f H1f1fH/1H Nf1NMHltlfifHiHlf1HHHlffHltH Hff HfllffflfbfHlf R11feHf fHHHtlHff ftf afflf f 1H H11ff The electrical Installation described above has been Inspected and was found to be essentially in accord with the minimm requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS I 250-114 1 Equipment grounds shall be spliced with a mechanical I I connector. I 110-13 1'Doorbell transformer shall be properly mounted. I 410-56(d)(e)I Range outlet shall have faceplate installed. I 336-10(b) I Romex to dishwasher shall be protected. I 210-52(b)(1)1 Hood shall not be wired on small appliance circuit. I 210-52(b)(1)1 Kitchen outlets shall not extend into bathrooms. I 250-61(b) I Grounds and neutrals shall be separated in subpanel. I 110-3(b) I Romex connectors shall not be installed backwards. 1 110-14 1 Feeder equipment ground shall not be reduced in number of I I strands (clipped). 1 110-22 1 Panel shall be labelled. 110-12 j Electrical installations shall be installed in a neat and workmanlike manner. ELECTRICAL INSPECTOR ka DATE EF•411 State of Idaho 2/18/88R Department of Lebor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 ADDRESS: PERMIT NUMBER: TYPE OF BUILDING: Apartment 6C LOCATION OF BUILDING: 151 _South First East Rexburg, Idaho 83440 •H\}b Hf }H 11H1HNf HffHf fffH1HRHRfNf fHNf 1f111ff}\11NHH N11f1RH H1Rf Hf}IH ff}}1f\ffRH f/\\f fff}HfYf1NH Nf} The electrical installation described above has been inspected and was found to be essentially in accord with the minim m requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS 210-52 1 No point along wall perimeter shall be farther than six feet I I from an outlet (dining room) I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 7C LOCATION OF BUILDING: 151 South First East Rexbure. Idaho 83440 t f f tRtf NN1f f NN1f11f NHNf NfNf fNRf •NN/Nf 1t}111N•►f 1tNtNNNN9Nf f f NRf f f tbf tf 1f 11f Nff b}Nf }N}}f}f RRNHf RN The alectrical installation described above has been inspected and was food to be essentially in accord with the minimum requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS I 210-52 1 Two outlets in bedroom are unenergized. I 110-22 1 Panel shall be labelled. 90-4 j There shall not be unt.erminated conductors in panel. 110-7 i There are signs'of arcing at bonding screw in apartment I I panel. I 110-3(b) I Fixtures shall not be over-lamped. 336-10(b) j Romex to dishwasher shall be protected. I 410-56(d)(e) I Range outlet shall have faceplate installed. I 110-12 1 Substandard workmanship. I ELECTRICAL INSPECTOR ka DATE EF•411 State of Idaho 2/18/88R Department of labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 8C LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 1ffH1NfHNfN111tltl1N1N1f11HfNHNHH1HHfNNf1NHf/HHH1f111f1ffif1lfbiHflfHNiHHN1fflHHfiffHfHNf of The electrical installation described above has been inspected and Was found to be essentlally in accord With the minimum requirements of the National Electrical Code except es follows. NEC REFERENCE I FINDINGS 410-57(a) and I Outside outlets shall have weatherproof covers and be ground 210-8(a)(3) 1 1 fault interrupter protected. 110-3(b) I I Panel shall be labelled.• 110-3(b) I I Circuit breakers shall not terminate more than one wire un - I i less so approved. 400-8(1) 1 1 Boilers shall be wired by an approved wiring method, not 1 cord. 90-4 1 Light fixture missing. 110-3(b) I I Romex shall not be installed next to boiler flue. 90-4 i 1 Romex around hot water pipe. 250-114 I 1 Equipment grounds shall be spliced (open in closet) 300-15 j Wires shall not be spliced outside of box or hidden in I I walls. 110-12 j Installation shall be neat and workmanlike. ELECTRICAL INSPECTOR ka DATE Page 1 of 2 EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: - TYPE OF BUILDING: Apartment 9C LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 •H1H HlN lhfff Hf IHV ffN Hf fiN1f 1tff11HfHRffffRllfiHlfHHlfNlfit111f11Rft!! VRif NtRNNfIHlRf1RH1fflb HflRf f NIH The electrical installation described above has been inspected and was found to be essentially in accord with the minimm requirements of the National Etectriaal Code except as follows. NEC REFERENCE I FINDINGS I I This unit was "red -tagged". I 110-14 and I Subpanel shall have feeder equipment ground with proper I 250 I lug terminated in panel. 250-61(b) ( ) I Separate neutrals and grounds in panel. I 110-22 I Seal openings in panel. 410-57(a)(3)1 I Outside outlet shall have a weatherproof cover. 210-8(a)(3) I Outside outlet shall have ground fault protection 90-4 I Ceiling needs repairing around bath fan. 210-52 I I Install outlet on east wall of southwest bedroom 410-56(d) I I Install receptacle faceplate in utility room I 410-56(e) i Tighten outlet in west wall of northwest bedroom. I 90-4 1 Reposition lamp in utility room. 250-80(b) ( ) 1 Bond hot water and gas piping to cold. ELECTRICAL INSPECTOR ka DATE Page 2 of 2 EF,411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark WE: Unknown ADDRESS. 625 .South 5000 west ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartemnt 9C (continued) LOCATION OF BUILDING: _ 151 South First East Rexburg. Idaho 83440 #fff#flff I#f it#NiflNfffNNRN►HRtfffffHN►RHHHN11f11NNHHff►►1#ffRNftNH11NRNH►fNfiHllf tfMtHHHfN Hfff The electrical installation described above .has been inspected and wasi found to be essentially. in accord with the minimum requirements of the National Electrical Code except as follows. _ NEC REFERENCE I FINDINGS 410-56(e) j Install extension ring and remount receptacle behind sink. 90-4 I Correct switching in living room. I 410-56(d) I Living room needs faceplate. I 110-12 1 Electrical installation shall be done in a workmanlike and I I neat manner. ELECTRICAL INSPECTOR ka DATE Page 1 of 2 EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: - CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 10C LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 ff fYf1fM;HNMRMRfRRefff 1NR1MtlfifbfN1f11fifR11RR11ffRH btfffllfRfffffifffH1t11HRff1lfRffRHffff bRf1f1f1RfffRRHH The electrical Installation described above has been inspected and Was found to be essentially in accord with the minimum requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS 400-8(1) I 1 Boiler shall be wired by approved method not 16-2 cord. 250-80(b) j Hot water and gas shall be bonded to cold. 110-3(b) I Light in utility unfinished and too close to flue. 90-4 I 1 Bad GFI in kitchen. 110-12 I 1 Panel secured by bent over nails. 110-22 1 Openings in panel shall be filled. 90-4 j Florescent light in kitchen is broken. 250-6(b) ( ) 1 Neutrals and grounds shall be separated in subpanel. 90-4 I I Boiler circulating pump flex conduit is unsecured. 250-61(b) ( ) I Bare splices in neutral in back of panel. 300-15 I 1 Open splices in closet shall be properly enclosed. 110-3(b) I I Romex connectors in panel shall not be installed backwards. 250-42(e) ( ) I Bath fans shall be properly and effectively grounded. 110-14 i Strands shall not be cut out of subpanel feeder ground. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR - NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS - Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 10C Page 2 of 2 LOCATION OF BUILDING: 151 South First _EastRexburg, .Idaho 83440 HNf fNfNf 1MHNtfN•NHNNfNNVNtM11ftlNM/tMtttNffftlftftHNf1N►fNNVffIftHVNtlffftfNHtf►ffffNNpfNHf The electrical Installation described above has been Inspected and was found to be essentially In accord with the minimus requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS I 210-52(b)(1)1 Kitchen and bathroom ground fault interrupter shall not be I 1 on the same circuit. I 110-36• 1 Fixtures shall not be over-lamped. 250-114 j Equipment grounds shall be connected with an approved I 1 mechanical connector. I 410-56(d)(e)I Needs range outlet and faceplate. 110-12 i Electrical installations shall be installed in a neat and workmanlike manner. ELECTRICAL INSPECTOR DATE ke 4ys sed Area Offee5: Anion 202 Anton Avenue. Suite 201, CceUf d'Alene, ID 83814 .1 O 307 EaSI LeWiS, P.O. BOX 4963, Pocatello, ID 83205-4963 M m r a Gary H. Gould. Director DEPARTMENT OF LABOR 277 North Sixth, Statehouse Mail, Boise, ID 83720 AND INDUSTRIAL SERVICES EQUAL OPPORTUNITY EMPLOYER November 21, 1990 TO: REXBURG CITY COUNCIL FROM: Dan Fadness, Electrical Inspector, Idaho State SUBJECT: Reinspection of Cottages Apts. Owned by Steve Clark Inspection was made on repairs and corrections by inspector Roy Frisk and myself on November 21, 1990. The following is a summary and not a detailed report, submitted for your deliberations concerning the property. Electrical contractor Ivan Jolly (number C-2956) is the con- tractor of record on the job. Repair work is being done under Idaho State Permit C180195. Corrections were being done off the repair punch list. Two areas were of concern to me. Mr. Clark and the contractor were replacing some bathroom fixtures that were not wet location rated, All bath/shower room fixtures shall be replaced, but all were not written up. Since the bath/shower rooms were all the same, the fixtures shall all be the same. Secondly, the service entrances were not cor- rected at all as of the time I was there. The service entrance is the heart of the system as the breaker panels are the brains and it is of major importance that all is correct at that location. Basically the inside is nearly done to the point that it could be rated acceptable and the outside has not been repaired and/or corrected yet. The final approval is still in progress but it is progressing. If I can be of further help, please call at 236-6089 or 756-3967. .Respectfully Su mitted, KDan Fa ness NOTE: Apt 10C is being used as a work base and no corrections or inspections were made in this area. e'll- '=890.ENiEN 90 J. D. Hancock City Attorney City of Rexburg 30 South 2nd West P. 0. Box 427 Rexburg, Idaho 83440 (208) 356-5493 Attorneys for Plaintiff IN THE DISTRICT COURT OF THE SEVENTH JUDICIAL DISTRICT OF THE STATE OF IDAHO IN AND FOR THE COUNTY OF MADISON MAGISTRATES DIVISION STATE OF IDAHO, Plaintiff, VS. Case No. CRIMINAL COMPLAINT STEVEN CLARK, Defendant. PERSONALLY APPEARED before me this 29th day of October, 1990, Chris Martin, a supervisor of the Idaho State Electrical Division, of Pocatello, in the County of Bannock, who being duly sworn, complains and says: COUNT 1. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install more than one small appliance circuit in the kitchen in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 220-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -1- �F COUNT 2. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to clearly label service equipment and circuit breaker panels in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 3. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly mount the doorbell transformer in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 4. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to cover the opening in the sheetrock with the panel cover in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 5. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a faceplate on the range outlet in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, CRIMINAL COMPLAINT -2- Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 6. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install operative outlets in the back bedroom in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 7. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install separate neutrals since the neutral shall not be used to ground equipment on the load side of the service disconnect in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT B. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 9. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -3- of Rexburg, County of Madison, State of Idaho, did fail to install a faceplate in the range receptacle in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 10. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly mount the doorbell transformer in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 11. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to flush or recess boxes not more than 1/4 inch in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-10, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 12. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install romex far enough away from the boiler flue pipe in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3b as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -4- COUNT 13. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did cut square holes in ceiling for round light boxes in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-10, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 14. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fill the unused opening in panel cover in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 15. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly ground the kitchen light fixture in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-18(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 16. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install the kitchen light fixture in Apartment 7-A of the Cottages Apartments located at 151 South First East, CRIMINAL COMPLAINT -5- 0 Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 17. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install receptacles of the grounding type (see by sink in bedroom) in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-7, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 18. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did use unapproved outlet boxes as the sole support of paddle fans in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-17(c), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 19. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did use the neutral to ground equipment on the load side of the service disconnect in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 20. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT Q'L' of Rexburg, County of Madison, State of Idaho, did fail to do electrical installations in a workmanlike manner in Apartment 7-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 21. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install the doorbell transformer in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 22. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install the bath fixture and repair sheetrock in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-10, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 23. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a fixture approved for a damp location in the northeast bathroom in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-4(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -7- COUNT 24. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a faceplate in the range outlet in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 25. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a flush range outlet box in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-10, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 26. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install an approved box on the paddle fan in Apartment B -A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-17(c), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 27. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a doorbell button in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in CRIMINAL COMPLAINT -8- violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 28. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did use the neutral for grounding on load side of service disconnect -in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 29. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install the electrical equipment in a workmanlike manner in Apartment 8-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 30. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to secure the outside porch light to the box in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-15(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 31. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install CRIMINAL COMPLAINT -9- kitchen outlets on bathroom circuits in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 220-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 32. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to flush or recess outlet boxes not more than 1/4 inch in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-10, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 33. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to rate bathroom fixtures for damp location in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-4(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 34. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fix the broken kitchen light fixture in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 35. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -10- of Rexburg, County of Madison, State of Idaho, did install knock out seals in the panel in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 36. That Steven Ctark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install romex against boiler flue between floors in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 37. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install missing receptacles in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. TAUNT 38. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to ground kitchen florescent fixture in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-18, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 39. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -11- of Rexburg, County of Madison, State of Idaho, did fail to separate neutrals and equipment grounds in subpanels in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 40. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 9-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 41. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fill unused openings in circuit breaker panel in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 42. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to secure romex to panel in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-5(c), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 43. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -12- of Rexburg, County of Madison, State of Idaho, did expose romex at doorbell transformer in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 336-10(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 44. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to separate the neutrals from the grounds in subpanel in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 45. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install the doorbell transformer in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 46. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to splice equipment grounds with mechanical connectors in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-114, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 47. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -13- of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 10-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 48. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly mount the doorbell transformer in Apartment 6-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 49. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install operative light by sink in Apartment 6-B of the (Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 50. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install bath fixtures approved for damp area in Apartment 6-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-4(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -14- COUNT 51. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a receptacle in the southeast bathroom in Apartment 6-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 52. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 6-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 53. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly mount doorbell transformer in Apartment 7-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 54. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install face plate on range outlet in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, CRIMINAL COMPLAINT -15- Idaho, in violation of the National Electrical Code, Section 910-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 55. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to label electrical panel in Apartment 7-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 56. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did over -lamp lighting fixtures in Apartment 7-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 57. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install doorbell transformer in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 58. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a cover over the kitchen light in Apartment 8-B of the CRIMINAL COMPLAINT -16- Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 59. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fix pinched wires under light in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 60. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to terminate bare conductors in panel in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 61. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to label electrical panel in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 62. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to CRIMINAL COMPLAINT -17- install faceplate on range outlet in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 63. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 8-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 64. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install kitchen and bath GFIs on the same circuit in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 220-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 65. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install doorbell transformer in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 66. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -18- of Rexburg, County of Madison, State of Idaho, did fail to separate panel grounds and neutrals in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 67. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did leave open holes in panel in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 68, That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to secure romex to panel with a connector in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-5(c), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 69. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to patch round boxes with square holes in sheetrock in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 370-15(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 70. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -19- of Rexburg, County of Madison, State of Idaho, did fail to protect romex at dishwasher in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 336-10(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 71. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to label electrical equipment panel in Apartment 9-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 72. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to splice equipment grounds with a mechanical connector in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-114, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 73. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly mount doorbell transformer in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-13, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 74. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -20- of Rexburg, County of Madison, State of Idaho, did fail to install faceplate on range outlet in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 75. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to protect romex to the dishwasher in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 336-10(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 76. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did wire hood on small appliance circuit in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52(b)(1), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 77. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install kitchen outlets so they did not extend into bathrooms in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52(b)(1), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -21- COUNT 78. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to separate grounds and neutrals in subpanel in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 79. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install romex connectors backwards in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 80. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did reduce number of feeder equipment ground strands in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-14, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 81. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to label electrical equipment panel in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section CRIMINAL COMPLAINT -22- 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 82. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 10-B of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 83. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to keep point along wall perimeter within six Teets from an outlet in the dining room in Apartment 6-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 84. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to energize two outlets in bedroom in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 85. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to CRIMINAL COMPLAINT -23- label electrical equipment panel in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 86, That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to determine all conductors in electrical equipment panel in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 87. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fix arcing at bonding screw in apartment panel in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-7, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 88. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did over -lamp fixtures in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 89. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -24- of Rexburg, County of Madison, State of Idaho, did fail to protect romex to dishwasher in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 336-10(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor: COUNT 90. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install a faceplate on the range outlet in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 91. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 7-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 92. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install weatherproof covers on outside outlets and be ground fault interruptor protected in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Sections 410-57(a) and 210-8(a)(3), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -25- COUNT 93. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to label electrical instrument panel in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 94. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install circuit breakers so that they shall not terminate more than one wire unless so approved in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 95. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to wire boilers by an approved wiring method, not cord, in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 500-8(a), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 96. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did not replace missing light fixture in Apartment 8-C of the Cottages CRIMINAL COMPLAINT -26- 0 Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 97. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install romex next to boiler flue in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 98. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install romex around hot water pipe in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 99. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to splice equipment grounds in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-114, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 100. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did splice wires outside of box or hidden in walls in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, CRIMINAL COMPLAINT -27- Idaho, in violation of the National Electrical Code, Section 300-15, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 101. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 8-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 102. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to have feeder equipment ground with proper lug terminated in subpanel in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Sections 110-14 and 250, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 103. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th 15th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to separate neutrals and grounds in panel in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 104. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -28- of Rexburg, County of Madison, State of Idaho, did fail to seal openings in panel in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 105. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly install service entrance cable in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 106. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install weatherproof cover on outside outlet in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(a)(3), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 107. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install ground fault protection on outside outlet in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-8(a)(3), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 108. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -29- of Rexburg, County of Madison, State of Idaho, did fail to repair ceiling around bath fan in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho,,in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 109. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install outlet on east wall of southwest bedroom in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 110. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install receptacle faceplate in utility room in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 111. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to tighten outlet in west wall of northwest bedroom in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 112. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -30- of Rexburg, County of Madison, State of Idaho, did fail to reposition lamp in utility room in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 113. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to bond hot water and gas piping to cold in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-80(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 114. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install extension ring and remount receptacle behind sink in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 115. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to correct switching in living room in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -31- COUNT 116. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install faceplate in living room in Apartment 9-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 117. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a workmanlike manner in Apartment 6-A of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 118. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to wire boiler by approved method in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 400-8(1), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 119. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to bond hot water and gas to cold in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, CRIMINAL COMPLAINT -32- Idaho, in violation of the National Electrical Code, Section 250-80(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 120. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to finish light in utility and did install too close to flue in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 121. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install a defective GFCI in kitchen in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 122. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did secure panel by bent over nails in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 123. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fill openings in panel in Apartment 10-C of the Cottages CRIMINAL COMPLAINT -33- Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-22, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 124. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to fix broken florescent light in kitchen in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 125. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to separate neutrals and grounds in subpanel in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-6(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 126. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to secure boiler circulating pump flex conduit in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 127. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City CRIMINAL COMPLAINT -34- of Rexburg, County of Madison, State of Idaho, did fail to take care of bare splices in neutral in back of pane. in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-61(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 128. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly enclosed open splices in closet in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 300-15, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 129. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install open romex connectors in panel backwards in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 130. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly and effectively ground bath fans in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-42(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -35- COUNT 131. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did cut strands out of subpanel feeder ground in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-14, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 132. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did install kitchen and bathroom ground fault interruptor on the same circuit in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 210-52(b)(1), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 133. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did over -lamp fixtures in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-36, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 134. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to have equipment grounds connected with an approved mechanical connector in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-114, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -36- COUNT 135. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install faceplace on range outlet in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 410-56(d)(e), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 136. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install electrical equipment in a neat and workmanlike manner in Apartment 10-C of the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 137. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did cause the main grounding electrode conductors to be undersized as they appear to be #6 copper or #4 copper conductor when the National Electrical Code would require 1/0 copper based on the 400 -ampere mains rating at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 250-94, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 138. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to tighten all bonding straps in the service panel and sheet metal screws have been substituted for the factory machine screws at CRIMINAL COMPLAINT -37- the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-12, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 139. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail make accessible the supplemental grounding electrode (ground rod) and conductor termination for inspection, but the number, size and routing of grounding conductors indicated a lack of understanding of proper grounding methods by the installer at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 140. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to properly use anti-oxygent on the aluminum feeder conductors at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 141. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did cause Square -D brand circuit breakers to be evident in meter bases 9 and 10 in violation of equipment listing at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 110-3(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. CRIMINAL COMPLAINT -38- COUNT 142, That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to install final fastener installation on all enclosures at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 90-4, as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 143. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did fail to individually secure the SER type feeder cables to the service equipment combination meter -disconnect enclosures with the proper connector and bushing, but rather were fed through a single knock -out with a chase nipple and therefore, the cables are not secured to the enclosure, but are capable of movement and the transmission of stress to the terminations at the circuit breakers, etc., at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 373-5(c), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. COUNT 144. That Steven Clark of 625 South 5000 West, Rexburg, Idaho, on or about the 19th day of October, 1990, in the City of Rexburg, County of Madison, State of Idaho, did expose romex on exterior of structure (behind gas pipe) to join mismatched walls at the Cottages Apartments located at 151 South First East, Rexburg, Idaho, in violation of the National Electrical Code, Section 336-10(b), as adopted by Rexburg City Ordinance No. 702, a misdemeanor. A copy of the State of Idaho Electrical Inspectors' report is attached hereto as Exhibit "A" and incorporated by this reference. CRIMINAL COMPLAINT -39- All of which is contrary to the form, force and effect of the statute and ordinances in such cases made and provided and against the peace and dignity of the state of Idaho. Said complainant therefore prays that a summons be issued to the said Steven Clark and that he may be dealt with according to the law. Chris Martin, Supervisor Idaho State Electrical Division SUBSCRIBED AND SWORN TO before me this 29th day of October, 1990. Brent J. Moss, Magistrate NOTE: Some items were not itentified against each specific apartment once it became apparent that all apartments suffered a similar deficiency. CRIMINAL COMPLAINT -40- October 19. 1990 TO: Gary L. Malmen Electrical Division Administrator FROM: Terry L. Coumerilh Electrical Licensing/Compliance SUBJECT: OVERVIEW OF INSPECTION OF "THE COTTAGES" REQUESTED BY THE CITY OF REXBURG On Tuesday, October 17, 1990, Mayor Nile Wiley of the City of Rexburg and Director of Public Works Farrel Davidson requested the assistance of the Electrical Division in assessing the electrical "condition" of a complex of apartments known as "The Cottages" located at 151 South First East. The units in question are indicated to be five (5) triplex apartments in a three story vertical arrangement. Because of the unavailability of Mr. Davidson on Wednesday, the inspection was scheduled for Thursday, October 19, 1990. On said date an inspection team consisting of Inspectors Dan Fadness, Roy Frisk and myself met with Mr. Davidson and conducted an electrical inspection of those items that were accessible and not requiring removal of building finish or that were not rendered inaccessible because of the occupants (comprised of approximately ninety (90) students and their associated furnishings, baggage, waterbeds, etc.). Some items (such as service panels and ground fault interrupter testing) were inspected in each and every apartment and other items were looked at on a random basis once a common deficiency was noted. Some items were not identified on the written list against each specific apartment once it became apparent that all apartments suffered a similar deficiency (e.g., over-lamping of fixtures in direct violation of warning on fixtures). It should be noted that in endeavoring to make this inspection, the team attempted to be a thorough as possible within the constraints imposed by occupation of the apartments without causing excessive inconvenience or time delays for the occupants or others. It has been noted previously that as redundancy of violations became apparent many were not itemized by the individual inspection team member against an individual apartment. 4&Af—!i6--- 133 UV-..-CTN N 1 A EQUAL OI'I'ONTUM i'Y EMI'L0Y611 OR (208)334-3D5U202 Area Offices: jo A111011 Avenue, Sulle 201 COCUr (I'Alelle, ID 83614 tzo61 76sss7l1307 •�1 • • I • • Easl I.C\v15. P.O. BOX 4063 POC61C110, ID 63205-4963 208) 233-4678 DEPARTMENT OF LABOR Gary 1-1. Gould, Director AND INDUSTRIAL SERVICES October 19. 1990 TO: Gary L. Malmen Electrical Division Administrator FROM: Terry L. Coumerilh Electrical Licensing/Compliance SUBJECT: OVERVIEW OF INSPECTION OF "THE COTTAGES" REQUESTED BY THE CITY OF REXBURG On Tuesday, October 17, 1990, Mayor Nile Wiley of the City of Rexburg and Director of Public Works Farrel Davidson requested the assistance of the Electrical Division in assessing the electrical "condition" of a complex of apartments known as "The Cottages" located at 151 South First East. The units in question are indicated to be five (5) triplex apartments in a three story vertical arrangement. Because of the unavailability of Mr. Davidson on Wednesday, the inspection was scheduled for Thursday, October 19, 1990. On said date an inspection team consisting of Inspectors Dan Fadness, Roy Frisk and myself met with Mr. Davidson and conducted an electrical inspection of those items that were accessible and not requiring removal of building finish or that were not rendered inaccessible because of the occupants (comprised of approximately ninety (90) students and their associated furnishings, baggage, waterbeds, etc.). Some items (such as service panels and ground fault interrupter testing) were inspected in each and every apartment and other items were looked at on a random basis once a common deficiency was noted. Some items were not identified on the written list against each specific apartment once it became apparent that all apartments suffered a similar deficiency (e.g., over-lamping of fixtures in direct violation of warning on fixtures). It should be noted that in endeavoring to make this inspection, the team attempted to be a thorough as possible within the constraints imposed by occupation of the apartments without causing excessive inconvenience or time delays for the occupants or others. It has been noted previously that as redundancy of violations became apparent many were not itemized by the individual inspection team member against an individual apartment. 4&Af—!i6--- 133 UV-..-CTN N 1 A EQUAL OI'I'ONTUM i'Y EMI'L0Y611 October 19, Memo: "The Page -2- 1990 Cottages" Inspection The appropriate corrective actions would require not only addressing the specific itemized violation as stated in the report, but competent licensed electrical personnel would by necessity have to inspect each and every location where similar discrepancies could be found. For example: 1. Spot checks show bath fans are not properly grounded due to misapplication or non-use of "ground clips". Ground clips are normally considered only slightly more complex than a screw, but it is obvious that because of the spot checks made all bath fans should be checked. 2. It is apparent, for example, that a mechanical connector has not been used at numerous splice locations. Some splices were made with the proper connectors. only investigation of each and every outlet, receptacle switch, light outlet, etc. would determine the actual numbers of this specific violation. 3. None of the circuit breaker panel directories were filled out. 4. Some individual panels exhibited evidence of "professional" involvement; i.e., separation of grounds and neutrals, proper bonding, neat workmanlike terminations, etc. Most panels showed a distinct lack of expertise or knowledge of electrical installations. Violations in panels create hazards ranging from electrical shock potential to, as in apartment 9C, the inability of a branch circuit breaker to trip because of unterminated feeder ground. 5. Integrity of the "firewall" system is much in doubt as observable penetrations have not been sealed with appropriate firestop. Page 1 of 3 EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAMEt Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESSt Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDINOt Service Eauipment LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 f\ff\fff\\•fiff\\•f\Nf\►►►f►f►H\f►f►\\\•f\fif\fit}f►\ff►\f►►\\ff\f\Iflfff\\\\\\ff\ff►\\\\\f►►►\Nf\\\fff\fH\\►Miff►\f\fff The stectrlcal Installation described above has been inspected and was foul to be essentlally In accord with the minister requirements of the National Electrical Code except as foltows NEC REFERENCE I FINDINGS I I Service equipment consists of four (4) general electric _ jthree gang meter -disconnects cat # TMM4312R with 100- 1 I ampere circuit breakers plus one (1) ITE brand four gang I I meter -disconnects with 100 ampere circuit breakers install - I I ed. All units are rated 400 -ampere service MiLins, 1 250-94 - f Main grounding electrode conductors appear undersized as I the I Y appear to be #6 copper or #4 copper conductor. The I i National Electrical Code would reauire 1/0 copper based on I I the 400 ampere mains rating 110-12 1 All bonding straps appear loose in the service panel and I I sheet metal screws have been substituted for the factory I machine screws. i ELECTRICAL INSPECTOR ka DATE Page 2 of 3 EF -411 2/i8/SSR PROPERTY OWNERS State of Idaho Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESSt 625 South 5000 West ADDRESSt Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BunDINGt __ Service Equipment LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 f11R1111RRRRf NR1RR1R111RRRfRRfff11R1RR1f1fRRf YfRRffffffiffRllfifff111f1fffNlRRfRRRRRfRffR Rff Rf111Rf RRRiRIffNfRNN1R1R1RRf The stectrlcal installation described above has been Inspected and was fotad to be essentiatly in accord with the mininm requirements of the National Electrfcal Code except as follows NEC REFERENCE I FINDINGS 90-4 j The supplemental grounding electrode (ground rod) and con- i I ductor termination were unaccessible for inspection The jnumber, size and routing of grounding conductors indicated I i a lack of understanding of proper grounding methods by the installer. _90-4 j The use of an anti -ox gent on the aluminum feeder conductors jranged from non-existent on some conductors to over (sloppy) application on others. 110-3(b) ( ) I Square -D brand circuit breakers were evident in meter bases I i 9 and 10 in violation of equipment listing I 90-4_ 1 All enclosures require final fastener installation 373-5(c) i In each I f nect enclosures the individual SER type feeder cables were I not individually secured to the enclosure with the proper ELECTRICAL INSPECTOR DATE ka EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY ONNERI CONTRACTORI NAME: Stephen E. Clark NAME: Unknown ADDRESSt 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Service Equipment Page 3 of 3 LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 •1111f1111111fef11NN11111111N111111111M111111111111f af1111111f•f11111111fef11111111fif1111111111f1f1111NfiNNlf af11111f The electrical installation described above has been Inspected and was found to be essentlally In accord with the minima requirements of the Nationsl Electrical Code except as follows NEC REFERENCE I FINDINGS _ I I connector and bushings but rather were fed through a single I I knock -out with a chase nipple. Therefore the cables are I I not secured to•the enclosure but are capable of movement I and the transmission of stress to the terminations at the i I circuit breakers etc. 336-10(b) I Romex shall not be exposed on exterior of structure (behind I I gas pipe) to join mismatched walls I ELECTRICAL INSPECTOR ke DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division PROPERTY OWNER: REQUESTED INSPECTION FINDINGS CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 6255 South 5000 {Nest _ ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING? Apartment 6A LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 RByyRyfMfyM1f yfyytllRRRRRRffH ltYflffH 1111f yy 11Rfy1 R11RRfff1RH H1Rf OffHlRRf yRbf kMNyyRl,ffif yfRf yffiflRHf1111 J1H •tyyy bfyf The electrical installation described above has been inspected and Was found to be essentially in accord with the minimum requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS I 220-4 (Only one small appliance circuit in kitchen I 110-22 iService equipment and circuit breaker panels shall be clear i ly labelled. 110-13 _ (Doorbell transformer shall be properly mounted not hanging I I from wires. 90-4 jPanel cover does not cover opening in sheetrock 410-56_d ( )(e) (Faceplate is needed on range outlet 210-52 iOutlets in back bedroom are inoperative 250-61(b) jThe neutral shall not be used to ground equipment on the load I 1 side of the service disconnect (separate neutrals) I 110-12 1Electrical equipment shall be installed in workmanlike man - I _ I ner. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Indastr Pat Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY ONNERt CONTRACTOR! uANEt Stephen E. Clark NAME.t Unknown ADDRESSt 625 South 5000 Nest Rexburg, Idaho 83440 ADDR[SSt PERMIT NUMBERt TYPE OF SUILDINGt Apartment 7A LOCATION OF SUILDINOt 151 South First East Rexburg. Idaho 83440 •ffffHNffffffeeN-**** N/HNMNetfHfffffNff ffNNaNNfNNaNNNlffefNNff*N -"*N "fffffNefNfNHfffftfffN The otectriaal Installation described above has been inspected and was foul to be aanntiatly In accord with the minimum requirements of the National Electrical Code except as follow. NEC REFERENCE I FINDINGS 410-56(d)(e) IThe range receptacle shall have a faceplate installed 110-13 doorbell tranE 11 be recessed not more than 1 inch. 110-3b IRomex is too close to boiler flue pipe 370-10 1 (square holes were cut in ceiling for round light boxes 373-4 iUnused opening in panel cover shall be filled 410-18(a) (Kitchen light fixture shall be properly, grounded 110-13 j Kitchen light fixture shall be properly instal 210-7 acles shall be of the grounding type (see by sink in I I bedroom). I 370-17(c) 1 Outlet boxes shall not be sole support of paddle fans I _ I (socket loose). _250-61(b) I The neutral shall not be used to ground equipment on the load I I side of the service disconnect 110-12 Electrical installations shall be done in a workmanlike manner. :LECTRICAL INSPECTOR DATE EF -01 2/18/88R PROPERTY OWNER: NAME: Stephen E. Clark State of Idaho Department of Labor and Industrial Services Electrical Division ADDRESSt 625 South 5000 Wes Rexburg, Idaho 83440 PERMIT NUMBER: REQUESTED INSPECTION FINDINGS CONTRACTORi NAMEI Unknown ADDRESS: TYPE OF BUILDINGS _.Apartment 8A LOCATION OF BUILDING: 151 South First East Rexburg. Idaho 83440 •Rf11f fRRRflff lffff1f1f11f•R111fH11111f1RRf if R111f1111fif1f11ff1H111/1f1ff11ffifftf RRR1RRRRRf1f11f11111R1ff1RHf1f1R RRRRf�f The electrical Installation described stove has been Inspected and was found to be essentially in accord with the minimum requirements of the National Electrical Code except as foltows NEC REFERENCE I FINDINGS 110-13 j Doorbell transformer shall be properly installed 370-10 j Bath fixture needs to be properly installed and sheetrock I _ I repaired. I 410-4(a) i Northeast bathroom fixture (Tracy's room) not approved for I I a damp location. 410-56 d ( )(e)I Range outlet needs faceplate 370-10 j Range outlet box shall be flush (recessed now) 370-17(c) _ I Plastic box on paddle fan 90-4 I No doorbell button 250-61(b) ( ) I The neutral shall not be used for grounding on load side of I L service disconnect 110-12 1 Electrical equipment shall be installed in a workmanlike I manner. ELECTRICAL INSPECTOR ka DATE IF -4.11 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY ONNER: CONTRACTORS NAMES Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBERS TYPE OF BUILDING: Apartment 9A LOCATION OF BUILDING: 151 South_ First East Rexburg, Idaho 83440 ff##R1f#f #W Wl ff11WIWWRWfffl lfffWR#•ffff111ff#f 11NffR1Hff11f1f##fRR##fffllW#Wifflf•##RRR1111W#!!!11!11 RWWf •ff RflH lf##1#•111 The electrical Installation described above has been Inspected and was found to be essentially In accord with the minimum requirements of the National Electrical Code except as follows. NEC REFERENCE I FINDINGS 410-15 a 1 ( ) I Outside porch light not secured to box ' I 220-4 1 Kitchen outlets on bathroom circuits _370-10 j Outlet boxes shall be flush or recessed not more than inch. 410-4(a) 1 ( ) I Bathroom fixtures not rated for damp location 90-4 1 Kitchen light fixture broken 373-4 j Panel needs knock out seals _110-3(b) I Romex against boiler flue between floors 1 210-52 1 Missing receptacles shall be installed 410-18 j Kitchen florescent fixture shall be grounded 250-61(b) I Neutrals and equipment grounds not separated in subpanels 110-12 1 Electrical installations shall be in workmanlike manner. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY MINER: CONTRACTORt NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West i ADDRESSt Rexburg, Idaho 83440 PERMIT NUMBERS TYPE OF BUILDINGS Apartment 10A LOCATION OF SUILDING1 151 South First East Rexburg, Idaho 83440 HitlNNINIH1fIHHffflfNNflfflfNbNNHiNNHIiN NIH NNII Hf 111fffHHHlf NfffHIN HNfHf N1fHffNNffHf NH The electrfcal installatfon described above has been inspected and was found to be essentielly In accord with the minfmua requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 1 373-4 1 Unused openings in n ;r nit br nkPr panel shall hP i;lle❑ 373-5(c 1 (_) I Romex shall be secured to panel (Just run through hole no I romex connector) 336-10(b) I ( ) I Exposed romex at doorbell transformer. 250-61(b) I ( ) 1 Neutrals shall be separate from grounds in subnanel 110-13 Doorbell transformer not properly installed 250-114 I i Equipment grounds shall be spliced with mechanical connectors I 110-12 I Electrical equipment shall be installed in a neat workman - I 1 like manner. ELECTRICAL INSPECTOR DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrfal Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS! 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBERS LOCATION OF BUILDING: TYPE OF BUILDING: Apartment 6B 151 South First East Rexburg Idaho 83440 f•R#RRRfifRRRifRfifRMRRRf iRRiAft#RR#RRRRRRRfiRRRifii RfRRlRfi•R1fif RRRR111RRRRRifRR Rif#R#RRR11Rif1fYRRR1RRR11RRRRifif 1ff11RRf The slectrical installation described above has been inspeeted and Was found to be essentially in accord with the minimus requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 110-13 1 Doorbell transformer shall be Dronerly mounted 90-4 iI Light by sink inoperative 410-4(a) ( ) I Bath fixtures are marginally out of damp area 210-52 1 Receptacle missing in southeast bathroom 110-12 _i All electrical installations shall be in a workmanlike I I manner. I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 7B LOCATION OF BUILDING: 151 _South First East Rexburg. Idaho 83440 •ffff»f ff»f»•»fffuf»ff»»fff»f»fff»ufffffff»uf»ffff fff»»f»»ff»»uf»f»ff»»w»f»ffff»fff m»fuf fff The electrical Installation described above has been inspected and was found to be essentially in accord with the minimum requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 110-13 i Doorbell transformer not properly mounted 410-56(d)(e)j Range outlet needs face plate. 110-22 j Panel shall be labelled. ELECTRICAL INSPECTOR ka Lighting fixtures shall not be over-lamped (exceeds rat DATE EF -411 State of Idaho 2/18/88R Department of talar and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME. —Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS. Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 8B LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 NN11fNf Nlf3NNNbfbNRNffNVNVNffNRRfffNNNN bfMNNff •fNfff IHR#N1b1RVRf NRIN NRNN#INNINH••##1b Nf The electrical Installation described above has been Inspected and was found to be essentially in accord with the minimum requirements of the -Rational Electrical Code except as follows NEC REFERENCE I FINDINGS 110-13 I Doorbell transformer not properly installed 90-4 1 Kitchen light needs cover. 110-12 I Wires being pinched under light I 210-52 1 Unterminated bare conductors in panel I 110-22 — 1 Panel needs labelling 410-56(d)(e)j Range outlet needs faceplate. 110-12 1 Electrical equipment shall be installed in a workmanlike I _ I manner. ELECTRICAL INSPECTOR ka DATE Ef•G11 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark ADDRESS: 625 South 5000 West Rexburg, Idaho 83440 PERMIT NUMBER: NAME: Unknown ADDRESS: TYPE OF BUILDING: Apartment 9B LOCATION Of BUILDING: 151 South _First East Rexburg. Idaho 83440 }}1f1f♦11f}f}flffffffRR}ff}fffff}11R}fiff}}}}f1fR}Rif1fl1ff11f11f1ffflfR}ffffifflfff•1R1111HRH1fff1f1:*c111}1111Rf fffl}}1t1f The electrical installation described above has been Inspected and was found to be essentiatly In ord with the minimum requirements of the National Electrical Code except as follows NEC REFERENCE 1 FINDINGS 220-4 i Kitchen and bath GFIs shall not be on the same circuit 110-13 1 Doorbell transformer not properly installed I 250-61(b) I Panel grounds and neutrals shall be separated 373-4 j Panel shall not have open holes 379-5(c) (_) i Romex shall be secured to panel with a connector 370-15(b) ( ) i Round boxes with square holes in sheetrock shall be patched. 336-10(b) ( ) I Romex at dishwasher shall be protected (it is exposed) 110-22 1 Panel shall be labelled I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2/18188R Department of Labor and industrial Services Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY OwwER: CONTRACTORS NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE of BUILDING: Apartment 10B LOCATION OF BUILDINGS 151 South First East Rexburg. Idaho 83440 1111!111}111}1}f•1f111111f1Nf1f11M1fff11M11f1Hfttf M11111111lf1f1111f1f1111ff•1f1f11Mfff1lf}111111f11111ff111f1ff}1111!! The electrical installation described above has been Inspected and was found to be essentially In accord with the minima requirements of the National Electrical Code except as follows,_ NEC REFERENCE I FINDINGS 1 250-114 1 Equipment grounds shall be spliced with a mechanical I 1 connector. 110-13 I Doorbell transformer shall be properly mounted. I 410-56(d)(e)I Range outlet shall have faceplate installed 336-10(b) 1 ( ) I Romex to dishwasher shall be protected. 210-52(b)(1)j Hood shall not be wired on small appliance circuit I _210-52(b)(1)1 Kitchen outlets shall not extend into bathrooms I 250-61(b) I Grounds and neutrals shall be separated in subpanel 110-14 1 I Feeder equipment ground shall not be reduced in number of I I strands (clipped). 1 110-22 1 Panel shall be labelled 110-12 j Electrical installations shall be installed in a neat and workmanlike manner. ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2118188R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAMEt Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING[ _ Apartment 6C LOCATION OF BUILDING: 151 South First East Rexburg Idaho 83440 •H�i•�4�b �i�M�tl1M���e�M Verb �H�b�N�biNf�HiM�M}�HHHtl��aIrM�H����f��1Rb�MNHR��H���b�Hff nuu�ufHOU The electrical Installation described above has been Inspected and was found to be essentially In accord with the minimum requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 210-52 No point along wall perimeter shall be farther than six feet I I from an outlet (dining room) I ELECTRICAL INSPECTOR ke DATE EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services - Electrical Division REOUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR - NAMES Stephen E. Clark NAME- Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBERS TYPE OF BUILDING: Apartment 7C LOCATION OF BUILDING: 151 South First EastRexburg, Idaho 83440 Nflf ffffffffffibMffbf flfafffffHflf fff bff •flHif9Hlf ffNlMfbbfRMfff tlfMlNf f iflM NfftlfHHflfffHAf MNf)fHff M The electrical installation described above has been Inspected and was found to be essentially in accord with the minimum requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS I 210-52 I Two outlets in bedroom are unenergized 110-22 I Panel shall be labelled. 90-4 1 There shall not be unterminated conductors in panel 110-7 j There are signs of arcing at bonding screw in apartment I , _I panel. I 110-3(b) I Fixtures shall not be over-lamped 336-10(b) I Romex to dishwasher shall be protected _410-56(d)(e) I Range outlet shall have faceplate installed I 110-12 1 Substandard workmanship I ELECTRICAL INSPECTOR ka DATE EF -411 State of Idaho 2118/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTORs NAME: Stephen E. Clark NAME: Unknown ADDRESSt 625 South 5000 West ADDRESSs Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 8C LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 H1f 1f 1H f#1b HRHHRRf H#1HH##Hf11H#HH#HMHfMH Hf Hf R1HH11M#RHHHRIR#1 HRf 1R#H1HR1bHHHHHHf#H HHRf The electrical Installation described above has been Inspected and was found to be essentially in accord with the mininun _requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 410-57(a)andl I Outside outlets shall have weatherproof covers and be ground 210-8(a)(3) I fault interrupter protected. 110-3(b) I Panel shall be labelled.. 110-3(b) I I Circuit breakers shall not terminate more than one wire un - I I less so approved. 400-8(1) i Boilers shall be wired by an approved wiring method not I cord. 90-4 1 1 Light fixture missing. 110-3(b) I Romex shall not be installed next to boiler flue 90-4 I 1 Romex around hot water pipe 250-114 1 J.-Eauipment ¢rounds shall hp sp1ir d (open in closet) 300-15 j Wires shall not be spliced outside of box or hidden in I I walls. 110-12 j Installation shall be neat and workmanlike ELECTRICAL INSPECTOR DATE Page 1 of 2 EF IG`11 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: - TYPE OF BUILDING: Apartment 9C LOCATION OF BUILDING: 151 South First East Rexburg, Idaho 83440 Ulf M1H1H 1ttf 1!!l1111Rtl11111Nf 1fef111R1f11Hf 1R11H11111ff R1f1ft11 tl1f11f MbRHR11tH1e111111fifR11 tl111if11M11ff H11f The electrical Installatlon described above has been Inspected and was found to be essentially In aceord with the minlrt um requirements of the National Electrical. Code .except as follows. NEC REFERENCE I FINDINGS I I This unit was "red -tagged" 110-14 and I Subpanel shall have feeder equipment ground with proper 250 I t lug terminated in panel 250-61(b) ( ) I Separate neutrals and grounds in panel 110-22 I t Seal openings in panel. 90-4 I I Repull service entrance cable and install properly. 410-57(a)(3)1I Outside outlet shall have a weatherproof cover. 210-8(a)(3)I I Outside outlet shall have ground fault protection 90-4 I Ceiling needs repairing around bath fan 210-52 I t Install outlet on east wall of southwest bedroom 410-56(d) I Install receptacle faceplate in utility room 410-56(e) I Tighten outlet in west wall of northwest bedroom I 90-4 1 Reposition lamp in utilitv room 250-80(b) I Bond hot water and gas piping to cold ELECTRICAL INSPECTOR DATE ka Page 2 of 2 EF�411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark WE: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartemnt 9C (continued) LOCATION OF BUILDING: 151 South First _East Rexburg, Idaho 83440 Hf•f ff}ffiHHf }f1fRH MH Hf 1HRRffNfUfiNf Hff bfiHHHltlff fRffHHf1H}HH}HH}HHHRb 1ffHHHffNbf Hff 1f1H 1ff The electrical installation described above has been Inspected and was found to be essentially in accord with the minima requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 410-56(e) I Install extension ring and remount receptacle behind sink 90-4 I Correct switching in living room. I 410-56(d) I Living room needs faceplate 1 110-12 I Electrical installation shall be done in a workmanlike and I I neat manner. ELECTRICAL INSPECTOR ka DATE Page 1 of 2 EF -411 State of Idaho 2/18/88R Department of Labor and Industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER! CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBERS TYPE OF BUILDING: Apartment 10C LOCATION OF BUILDING! 151 South First East Rexburg. Idaho 83440 •flltf Rfiff\ffflfRfif\fRf\\\\1ffRRllfif\fffY11\111ff\f 11ff/tif Rtll tf\ltff\RfM11f\1R\Rf\f\\\ltff\1ffR11RR11tf \ff1111R1RR\1 Rt\11R The electrical Installation described above has been Inspected and was found to be essentially in accord with the minimun requirements of the National Electrical Code except as follows NEC REFERENCE I FINDINGS 1 400-8(1) I _ Boiler shall be wired by approved method not 16-2 cord 250-80(b) j Hot water and gas shall be bonded to cold 110-3(b) ( ) I Light in utility unfinished and too close to flue I 90-4 1 Bad GFI in kitchen. I 110-12 1 Panel secured by bent over nails, 110-22 I Openings in panel shall be filled. 90-4 j Florescent light in kitchen is broken. 250-6 b 1 _ ( ) I Neutrals and grounds shall be separated in subpanel I _90-4 I , Boiler circulating pump flex conduit is unsecured 250-61(b) _i_Bare splices in neutral in ba 300-15 1 I Open splices in closet shall be properly enclosed I _110-3(b) I Romex connectors in panel shall not be installed backwards. 250-42(e) - I Bath fans shall be properly and effectively grounded 110-14 j Strands shall not be cut out of subpanel feeder ground ELECTRICAL INSPECTOR ka DATE Page 2 of 2 EF•411 State of Idaho 2/18/888 Department of Labor and industrial Services Electrical Division REQUESTED INSPECTION FINDINGS PROPERTY OWNER: CONTRACTOR: NAME: Stephen E. Clark NAME: Unknown ADDRESS: 625 South 5000 West ADDRESS: Rexburg, Idaho 83440 PERMIT NUMBER: TYPE OF BUILDING: Apartment 10C LOCATION OF BUILDING: .151 South First East Rexburg, Idaho 83440 •IItIRtRf IfR111fitllttMlfRl lftM/RfflR 1f f111fffRfffRf RRRRt If IiIRRIfIRRIti11tRRRfltt tftfllt tffRltltfffflfRfRfffRtlfRlfff lltRRfff The etectrfeal Installation described above has been Inspected and was found to be essentially In accord with the minimum requirements of the National Electrical Code except as follows. _ NEC REFERENCE I FINDINGS I 210-52(b)(1)I Kitchen and bathroom ground fault interrupter shall not be I on the same circuit. I 110-36 1 Fixtures shall not be over-lamped 250-114 j Equipment grounds shall be connected with an approved 1 mechanical connector. I 410-56(d)(e)l Needs range outlet and faceplate 110-12 I Electrical installations shall be installed in a neat and Iworkmanlike manner. ELECTRICAL INSPECTOR ka DATE ...•tib O4 NiA- O* (208) 334-3950 • .. area Offices: y A �, .R�.�• � �.,,,, � 202 AI110R Avenue. 25 Coeur d'Alene, IU 83814 Q4 ¢Pi7Cile?7{, °3jx �• ,N ,*41111. • ^I I 1208) 765-5579 307 Hast Lewis, P.O. BOX 4063, POCa1C11O. to 83205.496:3 NT�rE d OQ 4 • I '� • I • I • • - 208) 233-4678 DEPARTMENT OF LABOR Gary H. Gould, Director AND INDUSTRIAL SERVICES October 19, 1990 TO: Whom It May Concern FROM: Roy Frisk Electrical Inspector, 3-E SUBJECT: INSPECTION OF THE COTTAGES I helped inspect the apartments in Rexburg called The Cottages. In my findings, this place is a disaster. There are a lot of problems in all of the apartments. The National Electrical Code is a minimum guide for the installation of electrical and this complex does not even come close to that. As far as I'm concerned, there is a gray area for the safety of all people who live there. I feel that it would be advantageous for a good, qualified electrical contractor to clean up all of these problems. If I can be of more help, please call me. Mom NOW 1: EQUAL 01-1`0111 UNITY EMI'I.OVER U0�01u-- 1?OBI 3J4 -3J50 Area Offices: 202 Anton Avenue. Suite 201, Coeur d'Alene, ID 83814 izo9176s-ss79 307 East Lewis. P.O. Box 4063, Pocatello, ID 832054063 • 1 • • • • I • • 208) 233-4678 DEPARTMENT OF LABOR Gary H. Gould, Director AND INDUSTRIAL SERVICES October 19, 1990 TO: Whom It May Concern FROM: Dan Fadness Electrical Inspector, 3-C SUBJECT: INSPECTION OF THE COTTAGES I get a real bad gut feeling about this apartment complex. We found many violations from fairly minor to fairly major. I don't have any idea what lies in the covered walls, and I have absolutely no confidence in the electrical contractors and/or "journeymen". I would feel justified and comfortable calling for a license hearing on any or all of them. There appears to be nearly total lack of concern for personal safety and quality of work. ah EQUAL OPMATUNITY EMPLOYER �y G¢s Sa `� •J�°•n 1108) 334.39.;/) Area Offices: H " 202 AIIIOO Avenue. suite 201 Coeur d'Alene. ID 83814 M Y " e"�' �• - 1 4 ', YI (208) 765-5579 ♦q 307 Hast LewIS. P.O. 13OX 4963 Pocalelio. ID 83205.4963 AEE h OQ •' • • • 208) 233-4678 DEPARTMENT OF LABOR Gary H. Gould, Director AND INDUSTRIAL SERVICES October 19, 1990 TO: Whom It May Concern FROM: Terry L. Coumerilh Inspector Licensing/Compliance SUBJECT: INSPECTION OF "THE COTTAGES" In the inspection of electrical safety as pertains to enforcement of the minimum standards of the National Electrical Code, the inspector is given by the NEC the power of judgement (NEC 90-4) and is expected to apply the standards in a fair impartial and consistent manner along with the judgement of experience of the individual inspector. In the exercise of this judgement, the concept of "workmanship" plays as important part. Not only does it reflect the standards of the past, it reflects the future direction of installations whether they be electrical or otherwise. Therefore, "workmanship" is an important factor in determining the overall quality of the installation. It should also be noted that quality of workmanship is cited less often than other code sections because of its subjective aspects. That being said, the overview of this apartment complex is one of dismay. The workmanship and physical installation appear to have been done by a person or persons unknown who either do not understand and/or care about the niceties or basic requirements of electrical installations. This installation does show some evidence of a competent electrical installer, but such evidence is few and far between. It would appear that the majority of work has been done by unqualified and unsupervised persons. I can only assume these lack of qualifications would include violations of Idaho Electrical Licensing Laws. VCE iEN NIA L•19_pQ EQUAL OPPORTUNITY EMPLOYER October 19, 1990 Memo: Inspector Comments Terry Coumerilh Page -2- As a final comment, it should be pointed out that electrical installation is just one component of the whole and observation of the whole gives very little cause for optimism of the installations hidden by the structure finish. For example: romex in contact with loose (unsecured) water pipes can be detrimentally affected by that movement over a period of time; gaps around boxes allow the transference of heat and sparks into wall cavities and potential carbonization of wood products; battery powered smoke detectors instead of powered ones in violation of the Uniform Building Code; gas meters in close proximity to electrical service equipment, etc. All in all and overall in my opinion, this is one of the poorest installations I have seen in quite a while.