HomeMy WebLinkAboutREVIEWS - 01-00022 - Beckenridge Apartments - 12 Units6/18/2001 Bill Follett Green Valley P.O. Box 156 Ucon, ID 83454 Dear Bill: edy (012exiar 7 STATE OF IDAHO www.drexburg.id.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone(208)359-3020 Fax(208)359-3022 e-mail rexburg®Ci.rexburg.id.us I have reviewed the plans for the Breckenridge apartments and have identified the following discrepancies: 1. Provide handicap ramp at corner of I" West and 2nd South. 2. Screen the garbage dumpster and place in an area where a side -loading truck can access it. 3. Provide 28' radius for fire truck at South entrance. Also create wider driveway by eliminating the sidewalk on the South side of the building in the Southeast corner of the project. 4. Provide fire hydrant as per Rexburg Fire Department. 5. Sidewalk and driveway at street approaches will need to be constructed of 6" reinforced concrete. 6. Provide details of handicap ramp. 7. Provide sprinkler plan. 8. Show the fire sprinkler system mechanical room inside of the building. It can not be in a setback. 9. Provide draftstop details. 10. Provide floor details for 1-hr.fire resistance. 11. Identify smoke detectors. 12. Provide door details. 13. Provide mechanical information. 14. Provide electrical plan. 15. Provide detail showing pipe penetrations into firewalls. 16. Provide Type "A" Accessible Unit. Provide details such as grab bar, cabinet, toilet, sink, shower, etc. 17. Address any items identified by the Fire Department. I have attached a copy of their review to the back of this document. Please make the necessary corrections and return two sets of drawings as soon as possible. If you have any questions please give me a call at 359-3020 ext. 314. Sincerely, Val Christensen Assistant Engineer cc: John Millar Chris Huskinson REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 02-01 Plan Review Review Date: 06-05-01 Building Name: Breckenridge Apartments Building Address: Corner of First West and Second South Stories: 3 Type of Construction: V-1 Occupancy Classification: R-1 Existing Floor Area: N/A New Construction Floor Area: @ 13,535 square feet 1).Required Fire Flow (Appendix III -A): 1,500 GPM 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: C18, C25 Fire Hydrant Flows: OK Fire Flow Test Location: C18, C25 Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: NO Fire Hydrant Location Acceptable: Existing OK, provide one hydrant on site Water Supply Comments: Need to add one hydrant on site to comply with UFC. Best location would be on the sidewalk near the south end of proposed building (Between new and old structures). 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: NO Turning Radius: NO Clearance: U/K Length: NO Surface: OK Grade: OK Vehicle Vertical:U/K Turn Arounds: NONE Complete Road Acceptable: NO Comments: Corners in parking lot need to have minimum of 28 foot radius (around parking stalls) and the southwest stall at rear of managers building. There shall be no parking (Signed and marked with paint) along the sidewalk on the east side of new building to allow for fire apparatus access. Existing driveway to the south of proposed manager's building too narrow. Needs to be a minimum of 20 feet wide with no parking (Signed and marked with paint). Parking along southern edge of property doesn't allow fire apparatus to fully access old building. 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: Not Shown Type Provided Acceptable: Minimum of 2A-10BC required 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: YES Type Of System Being Installed: Unknown Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: U/K Comments: Have not been provided with sprinkler plans. 9).Fire Alarm Systems (Article 10 Section 1007)Required: YES Type Of System Required: Manual: Automatic: Both: YES Type Of System Being Provided: Manual: Automatic: Unknown what type of system to be provided, no plans submitted. Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO 10).Other Corrections That Are Required By Special Occupancy Or Conditions: Plans As Submitted Are Acceptable: NO Plans Checked By: Chris Huskinson Date: 6-05-01 Please furnish comments back to the plan reviewer in the following manner: Written Comments: YES New Plans: YES ugG '0/�/�,o, P.o. Box 280 YS edy 01ea�°�(//ary 12 North Center Street Rexburg, Idaho 93440 Phone (209) 359-3020 STATE OF IDAHO Fax (209) 359-3022 e<IsHF www.c1.rexburg.id.us e-mail rexburg®ci,rexburg.id.us 8/20/2001 Scott Spaulding Design Intelligence 135 East Main Rexburg, Idaho 83440 Dear Scott, On 8/17/01,1 completed framing inspection on the Erickson Pontiac Building. Below is a list of items that I have identified as incomplete, incorrect or unexplained: 1. The front wall and the side.walls of the show room were not engineered for seismic or wind loads. Please provide details and calculations. 2. The boiler room has been moved to the mezzanine area. A beam is carrying part of the load from the boiler room floor. This beam transmits its load to the walls below. The walls transfer the load to the floor slab that has not been designed for this purpose. Please provide me with the calculations showing that the unreinforced slab will be adequate to support the loads from the newly created bearing wall and especially the point load generated from the column carrying the end of the beam. 3. The original plans call out for the interior wood framed walls to be sheeted with 5/8" o.s.b. for shear purposes. It has come to my understanding that the contractor wants to substitute angle bracing in place of the o.s.b. panels. Please provide me with details and calculations required to make the change. 4. We had requested a fist and the times of the special inspections required as per the 1997 Uniform Building Code (UBC) Section 1701.5. Concrete, Bolting and Field Welding all require special inspections. At this time we have not received any information concerning these inspections. 5. I am a little concerned about the headroom in the mezzanine area. The fire sprinkler pipe is at "head banging" level on one side and a steel beam in the boiler room is definitely a safety concern for the same reason. Please make some provisions for clearly identifying these potential safety concerns. Please let me know if there will be any problems making the above changes. If you have any questions, please give me a call at 359-3020 ext. 324. Sincerely,. G �� Val Christensen Assistant Engineer cc: John Millar Chris Huskinson