HomeMy WebLinkAboutPLAN REVIEWS - 02-00026 - Kensington ApartmentsF��BURci /` ////�/'� //// O ///� �(�o/(�r� ��//pp P.O. Box 280 edy of ILeoA1.R/ ar7 12 North Center Street « , Rexburg, Idaho 83440 Phone (208) 359-3020 STATE OF IDAHO Fax (208) 359-3022 g<IsHEO www.ci.rexburg.id.us e-mail rexburg@ci.rexburg.id.us 4/1/2002 Scott Spaulding Design Intelligence 135 East Main Rexburg, Idaho 83440 Dear Scott, I have reviewed the Ashbury Apartment drawings that you have provided me and have identified the following discrepancies: 1. Building setbacks are to eaves. Change front setback as required. 2. Add fire hydrants as per request by Fire Department. I have attached a copy of the Fire Department review to the back of this document. 3. Dumpster can't be located in front setback. 4. A fence or a suitable buffer must be provided between parking areas and other residential properties. 5. Two parking spaces are required for manager's apartment. 6. Parking spaces under building don't fit. 7. Elevations are not provided at parking under building. The aisle adjacent to this parking is a fire lane and must have an even grade. 8. Provide handicapped parking. 9. An accessible routemust be provided to all the lower units. The drawing identifies stairs along this route. 10. The managers apartment must be on ground level. The apartment must be designed so that a handicapped manager could reside in it. In other words, you must not have any use on the upper floor of the unit that you don't provide on the first floor. Bathroom on lower level must be constructed per ADA requirements. 11. Provide details for grab bars and fixtures in ADA bathrooms. 12. All lower level units must be constructed as per 1997 Uniform Building Code (UBC) Section 1106 Type B Dwelling Units. Provide details. 13. The bathroom in the Type A unit does not work. The interior aisle between the door and the fixtures is too narrow. 14. Ceiling above balcony must be constructed as one hour fire resistive. Please provide details. 15. Please provide details of fire separation between the under floor parking and the units above. 16. Front doors are required to be'/< hour assemblies. 17. Provide details that identify Fire Department requests. If hydrants are added, please identify. If 4 -hour separation walls are to be used, please provide details. 4 -hour walls can't be placed at walls containing doors. Identify hire extinguishers, smoke detectors and horn strobes as per Fire Department. I have attached the list from the Fire Department to the back of this document. 18. Provide balcony details for fire resistance construction as per UBC Section 1006.3.2.3. 19. Provide truss manufacturer specifications and detail sheets. 20. I didn't see where floor/ceiling fire separation was called out. With TH floor systems, two layers of 1/2" Type "Y' drywall are required. Please provide me with 2 sets of revised plans. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359-3020 ext. 324. Siincerely, vR Val Christensen Building Official cc John Millar Chris Huskinson Tom Sainsbury REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359-3010 1997 Uniform Fire Code Plan Date: 12/2001 Plan Review Review Date: 3/28/02 Building Name: ASHBURY PLACE Building Address: APPROXIMATELY 365 SOUTH SECOND EAST Stories: 2.5 Type of Construction: V -N Occupancy Classification: R-1 Existing Floor Area: N/A New Construction Floor Area: 18,738 SQ. FT. 1).Required Fire Flow (Appendix III -A): 3,750 GPM FOR THREE HOURS Comments: FLOW MAY BE REDUCED BY UP TO 75% IF BUILDING HAS AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM INSTALLED. 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant Location: D-31, D-34, D-38 Fire Hydrant Flows: D-31=750 GPM, D-38=712 GPM, D-34=1256 GPM Fire Flow Test Location: SAME AS ABOVE Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: NO Fire Hydrant Location Acceptable: NO Water Supply Comments: BASED ON BUILDING SQUARE FOOTAGE TABLE A - III -B -I REQUIRES FOUR HYDRANTS WITHIN 350 FEET OF EACH PROPOSED BUILDING. EXISTING HYDRANTS DO NOT PROVIDE SUFFICENT FLOW, ONLY ONE HYDRANT IS WITHIN THE 350 FOOT RANGE. NEED TO PROVIDE THREE ADDITIONAL HYDRANTS. 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES Acceptable: Width: YES Length: YES Surface: OKAY Turning Radius: OKAY Grade: OKAY SIGNAGE: NO Clearance: OKAY Turn Arounds: OKAY Complete Road Acceptable: NO, DRIVEWAY DIRECTLY IN FRONT OF BUILDING MUST BE SIGNED � FIRE LANE, NO PARKING ALONG ENTIRE LENGTH IN ADDITION TO HAVING THE CURB PAINTED RED AND MAINTAINED. 4).Access Roads and Water Supply, Including Fire Hydrants Are Required To Be Installed And Made Serviceable Prior To And During Time Of Construction (Article 9 Section 901.3): YES Comments: HYDRANTS AND ACCESS MUST BE INSTALLED AND OPERATIVE PRIOR TO CONSTRUCTION OR A STOP WORK WILL BE ISSUED. 5),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: NOT SHOWN Comments: PROVIDE MINIMUM OF ONE 2A10BC FIRE EXTINGUISHER PER UNIT IN ADDITION TO COMMON AREAS, LAUNDRIES, ETC. 6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: NO Type Of System Being Installed: Sprinkler System Monitoring Required (Article 10 Section 1003.3) Required: NO Comments: 7).Standpipes (Article 10 Section 1004) Required: NO Type Required: Comments: 8).Ventilating Hood And Duct Fire Extinguishing System (Article 10 Section 1006.2) Required: NO Type Being Provided: Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4): Portable Fire Extinguisher Shown (Article 10 section 1006.2.7): Comments: 9) Fire Alarm Systems (Article 10 Section 1007)Required: SEE COMMENTS Type Of System Required: Manual: Automatic: Both: Type Of System Being Provided: Manual: Automatic: Both: Components Of System Shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: Comments: SMOKE DETECTORS REQUIRED IN EACH SLEEPING ROOM AND ADJOINING CORRIDORS. HORN/STROBES AND SMOKE DETECTORS REQUIRED IN TYPE � 4 HANDICAP UNIT. 10).Other Corrections That Are Required By Special Occupancy Or Conditions: ADDRESS ALL ABOVE ITEMS Plans As Submitted Are Acceptable: NO Plans Checked By: CHRIS HUSKINSON Date: 3-28-02 Please furnish comments back to the plan reviewer in the following manner: Written Comments: YES New Plans: YES