Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FIRE ALARM PLANS - 16-00478-482 - Campus Courtyard 2
May 22, 2017 Rexburg Fire Department Pocatello, ID RE: Fire Alarm Plan Review for Campus Courtyard II Attn: Fire Marshal Dear Sir, Please review the enclosed fire alarm submittal for Campus Courtyard, located at 269 S. 5`h West, Rexburg, ID 83440. The scope of the job consists of installaing an new addressable fire alarm system. Enclosed are copies of the floor plan with device locations, manufacturer cut sheets, battery calculations, and voltage drop calculations. If you have any questions or changes, please give me a call at (208) 524-4282. Thank you for your time, Wes Ryan Peak Alarm Company Inc. touts Print Page Global Project Values: SILLNT Project Name: Cam us Courtyard II 24 Standby Hours:KNIGHT Project 1O: Alarm Mins:0 Prepared ByJ Peak Alarm. Kenny Fox Derating Factor: 1.2 r Date: 5/18/2017 Voltage Drop Warning Version r 24.14 Threshold %: 15 Panel ID: 5820XL-EVS Model: 5820XL-EVS Add. Fire Alarm Control Max NAC Current: 3.0 Amps Location: IT/Electrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5820XL-EVS 5820XL-EVS CTRL Panel 1 0.275 1 0.440 SK Photo, Photo -T, Photo -R i 0.000 1 0.000 SK Ion 0.000 0.000 SK Heat, Heat -HT 2 0.001 0.001 SK Heat ROR 0.000 0.000 SK Beam, Beam -T 0.000 0.000 SK Duct 0.000 0.000 SK Acclimate 0.000 0.000 SK Fire -CO 0.000 0.000 SK Control 0.000 0.000 SK Control -6 0.000 0.000 SK Monitor Minimon 4 0.002 0.002 SK Monitor -2 0.000 0.000 SK Monitor -10 0.000 0.000 SK Pull -SA Pull -DA 13 0.005 0.005 SK Relay '. 0.000 0.000 SK Relay -6 - 0.000 0.000 SK Zone 0.000 0.000 SK Zone -6 0.000 0.000 SK Relay -Mon -2 0.000 0.000 SK Isolator Module 0.000 0.000 822461 Isolator Base 0.000 0.000 B200SR Sounder Base 0.000 0.000 B200S Sounder Base 0.000 0.000 B200SR-LF Low Freg Sounder Base 0.000 0.000 B200S-LF Low Freq Sounder Base 0.000 0.000 B224RB Relay Base 0.000 0.000 RTS151 Magneto o Remote Test 0.000 0.000 RTS151KEY Key Activated Test 0.000 0.000 RA100Z Remote LED 0.000 0.000 5815XL SLC Loop Expander 0.000 0.000 5860 LCD Remote Annunc 0.000 0.000 5824 Serial/Parallel Module 0.000 0.000 5496 Power Expander 0.000 0.000 5895XL Power Expander 0.000 0.000 5865-4 LED Annunciator 4G 0.000 0.000 5865-3 LED Annunciator 3G 0.000 0.000 5880 LED Driver Module 0.000 0.000 5883 Relay Module 0.000 0.000 EVS-VCM Voice Control Module 0.000 0.000 EVS-SW24 Switch Expander 0.000r00(0)00 EVS-AMP 50W 100W or 125W 0.000 EVS-RVM Remote Voice Module 0.000 EVS-100WBU BackupAm Card 0.000 PGM -1/0#1 Notification APPI Circuit 0.000 0.996 #14 Solid 2.52 300 1.51 18.89 7.38% PGM -1/0#2 Notification Appl Circuit 0.000 1.173 #14 Solid 2.52 300 1.51 18.63 8.69% PGM -110#3 Notification A I Circuit 0.000 0.907 #14 Solid 2.52 300 1.51 19.03 6.72% PGM -1/0#4 Notification A I Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% PGM -1/0 #5 Notification A I Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% PGM -1/0 #6 Notification A I Circuit 0.000 0.000 #12 Solid 1.59 0.00 20.40 0.00% touts Print Page Standby Hours: 24 Alarm Mins: Derating Factor: 1.2 Voltage Drop Warning Threshold %: 10 Max NAC Current: 3.0 Amps Max Panel Current: 6.0 Amps Ckt.# Circuit Name --l'-1-1 vvuc 1v viuua rei uenyugiy Mtudl vun5 ly7 Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 0.075 0.205 NAC #1 Global Project Values: SILENT Project Name: Cam us Courtyard II KNIGHT Project ID:O 400 2.02 1 Prepared By: Peak Alarm 5495 Power Ex• • r • Date: 5/18/2017 Version 02.18.09 0.996 Panel ID: 15495 NAC #1 Model: 5495 Power Expander Location: IT/Electrical Room Volts: 24 VDC Standby Hours: 24 Alarm Mins: Derating Factor: 1.2 Voltage Drop Warning Threshold %: 10 Max NAC Current: 3.0 Amps Max Panel Current: 6.0 Amps Ckt.# Circuit Name --l'-1-1 vvuc 1v viuua rei uenyugiy Mtudl vun5 ly7 Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 0.075 0.205 NAC #1 5495 Circuit 1 1 0.000 1 1.006 #14 Solid 2.52 400 2.02 18.37 NAC #2 5495 Circuit 2 0.000 0.996 #14 Solid 2.52 400 2.02 18.39 NAC #3 5495 Circuit 3 0.000 0.996 #14 Solid 2.52 400 2.02 18.39 NAC #4 5495 Circuit 4 0.000 1 0.000 #12 Solid 1.59 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 Total Standby Current Ams 0.075 3.203 Total Alarm Cl Standbv Time In Hours 24 0.083 Alarm Time In The Derating Factor 1.20 wire resistances are based upon an ambient temperature of 72 degrees F. Becar the minimal difference between solid and stranded wire no differential was made. Configure Circuits Print Page ise of Configure Circuits Print Page Global Project Values: SILE NT Project Name: Cam us Courtyard II Standby Hours: 24 Project ID: Alarm Mins: Prepared By: Peak Alarm Derating Factor: 1.2 • Power Ex• - • - Date: 5/18/2017 Voltage Drop Warning Version 0... c, 0, Threshold %: 10 Panel ID:. 5495 NAC #2 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: ITIElectrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 1 0.075 1 0.205 NAC #1 5495 Circuit 1 0.000 0.830 #14 Solid 2.52 400 2.02 18.73 NAC #2 5495 Circuit 2 0.000 0.996 #14 Solid 2.52 400 2.02 18.39 NAC #3 5495 Circuit 3 0.000 0.830 #14 Solid 2.52 400 2.02 18.73 NAC #4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 Total Standby Current Ams 0.075 2.861 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes / 60 5 Mins Total Standlov AH Re uired 1.800 0.238 Total Alarm AH Re uired Total Combined AH Required 2.04 Multiply By The Derating Factor 1.20 Wire resistances are based upon an ambient temperature of 72 degrees F. Becac the minimal difference between solid and stranded wire no differential was made. Minimum Battery AmpHours Required 2.45 Configure Circuits Print Page ise of Configure Circuits Print Page Global Project Values: SILENT Project Name: I Campus Courtyard II Standby Hours: 24 KNIGHTI Project ID: Alarm Mins: Prepared By: IPeak Alarm Derating Factor: 1.2 5495 Power Expander CalculationsDate:F5/-18/-20--17---1 Voltage Drop Warning Version t t, Threshold %: 10 Panel ID: 15495 NAC #3 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: IT/Electrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.830 #14 Solid 2.52 400 2.02 NAC #2 5495 Circuit 2 0.000 0.996 #14 Solid 2.52 400 2.02 NAC #3 5495 Circuit 3 0.000 0.830 #14 Solid 2.52 g8.7 400 2.02 NAC #4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 Total Standby Currenf Ams 0.075 2.861 Total Alarm Current (Amps) Standby Time In Hours 24 1 0.083 Alarm Time In Minutes/ 60 5 Mins Total Standbv AH Re uired 1.800 1 0.238 ITotal Alarm AH Re uired Total Combined AH Required 2.04 Multiply By The Derating Factor 1.20 Wire resistances are based upon an ambient temperature of 72 degrees F. Becar the minimal difference between solid and stranded wire no differential was made. Minimum BatteAm Hours Re uired 2.45 Configure Circuits Print Page Js of NAC #1 5495 Circuit 1 Global Project Values: 0.830 1#14 Solid SILENT Project Name: Cam us Courtyard II Standby Hours:KNIGHT 24 NAC #2 5495 Circuit 2 Project ID:O Alarm Mins: #14 Solid 2.52 Prepared By: Peak Alarm Derating Factor: 1.2 5495 Power ExpanderDate: 5/18/2017 Voltage Drop Warning #14 Solid Version 0218.09 Threshold%: 10 Panel ID: 15495 NAC #4 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: IT/Electrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ #12 Solid 1.59 Vndlby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 15495 Pwr Module f n n7 n 9F, NAC #1 5495 Circuit 1 0.000 1 0.830 1#14 Solid 2.52 1 400 2.02 18.73 NAC #2 5495 Circuit 2 0.000 0.996 #14 Solid 2.52 400 2.02 18.39 NAC #3 5495 Circuit 3 0.000 0.830 #14 Solid 2.52 400 2.02 18.73 NAC #4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 2040. 0.075 1 2.861 Time In Minutes / AHRe wired 2.04 !ratio Factor 1.20 wire resistances are based upon an ambient temperature of 72 degrees F. BecaL the minimal difference between solid and stranded wire no differential was made. Configure Circuits Print Page ise of Configure Circuits Print Page Global Project Values: ySILENTProject Name: I Campus Courtyard II Standby Hours:KNIGHT 24 Project ID: Alarm Mins: Prepared By: Peak Alarm Derating Factor: 1.2 5495 Power Expander- 1 Date: 5/18/2017 Voltage Drop Warning 02,118.09 Threshold%: 10 Panel ID: 15495 NAC #5 Model: 5495 Power Expander Max NAC Current: 3.0 Amps Location: IT/Electrical Room Volts: 24 VDC Max Panel Current: 6.0 Amps Ckt.# Circuit Name Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ Standby Alarm & Type 1000 Ft. One -Way Ohms EOL 5495 5495 Pwr Module 1 1 0.075 0.205 NAC #1 5495 Circuit 1 0.000 0.830 #14 Solid 2.52 400 2.02 18.73 NAC #2 5495 Circuit 2 0.000 0.996 #14 Solid 2.52 400 2.02 18.39 NAC #3 5495 Circuit 3 0.000 0.830 #14 Solid 2.52 400 2.02 18.73 NAC #4 5495 Circuit 4 0.000 0.000 #12 Solid 1.59 0.00 20.40 Aux 5495 Aux Power Out 0.000 0.000 #12 Solid 1.59 0.00 20.40 Total Standby Current Ams 0.075 2.861 Total Alarm Current (Amps) Standby Time In Hours 24 0.083 Alarm Time In Minutes 160 5 Mins Total Standbv AH Recruired 1.800 0.238 Total Alarm AH Re uired Total Combined AH Required 2,04 Multiply By The Derating Factor 1,20 wire resistances are based upon an ambient temperature of 72 degrees F. BeCal the minimal difference between solid and stranded wire no differential was made. Minimum Battery Am Hours Required 2.45 Configure Circuits Print Page ise of SILENT IntelliKnight° Model 5820XL KNIGHT Addressable Fire by Honeywell well Alarm Control System The IntelliKnight System is the easy way to make the most of fire alarm technology. IntelliKnight 5820XL is the first fire alarm system to provide you with revolutionary value and performance in addressable sensing technology. The 5820XL FACP offers exclusive, built-in digital communication, distributed intelligent power, a modular design and an expanded, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the 5820XL system, or to locate your nearest source, please call 800-328-0103. Description 5820XL is an intelligent addressable fire alarm control panel (FACP). The basic 5820XL system can be expanded by adding modules such as 5860 remote annunciator, 5815XL signalling line circuit expander, 5824 serial/parallel printer interface module (for printing system reports), and 5895XL intelligent power module. 5820XL supports SD or SK devices. 5820XL also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. Features • Built in support for 99 SK detectors and 99 SK modules, expandable to 396 SK detectors and 396 SK modules using System Sensor protocol • Built in support for 127 SD devices, expandable to 508 SD devices using the SD protocol. • Uses standard wire—no shielded or twisted pair required • Built-in digital communicator • Central station reporting by point or by zone • Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor, and Wheelock® • FlexputTM 1/0 circuits • Supports Class B (St le 4) and Class A (Style 6) configuration for SLC, SBUS, and Flexput circuits • 13 pre-programmed output cadences (including ANSI -3.41) and 4 programmable outputs • Built-in annunciator with 80 -character LCD display • RS -485 bus provides communication to system accessories • Built-in RS -232 and USB interface for programming via PC • Built-in Form C trouble relay rated at 2.5 amps at 27.4 VDC • Improvements in SKSS software deliver five times faster uploads /downloads • Two built-in Form C programmable relays rated at 2.5 amps at 27.4 VDC • Plex-1 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Model 5820XL • 6 amp power supply and maximum charring capacity of 35 amp hours (An additional cabinet enclosure is required for batteries in excess of 18 amp hours) • Pro9rammable date setting for Daylight Saving Time Installation The 5820XL can be surface or flush mounted Compatibility The 5820XL signal line circuit (SLC) supports multiple device types of the same protocol: • SK (System Sensor) • SD You cannot mix SD and SK SLC devices on a FACP. IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Indicator Lights General Alarm (Red): Flashes when in alarm; solid when alarm silenced Supervisory (Yellow): Flashes when a supervisory condition exists; solid when supervisory silenced System Troubles (Yellow): Flashes when a trouble condition exists; solid when trouble silenced System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared System Power (Green): Flashes for AC failure; solid when power systems are normal System Application 5820XL has one built-in signalling line circuit (SLC) which supports multiple devices dependent on protocol being used. Three additional loops can be added using the 5815XL SLC expanders to increase overall capacity. The 5820XL SLC loops support multiple device types, including: • Addressable photoelectric smoke detector • Addressable ionization smoke detector • Addressable heal sensor • Addressable duct smoke detector • Contact module • Relay output module • Addressable notification module • Addressable beam detector (SK protocol only) • Addressable multi -criteria smoke detector (SK protocol only) • Addressable multi modules (SK protocol only) The following advanced sensor capabilities are available with 5820XL: • Automatic drift compensation • Maintenance alert • Built-in sensor test to comply with NFPA 72 calibration testing requirements 5820XL features a 6 amp power supply and maximum battery charging capacity of 35 amp hours. An additional cabinet enclosure (PN RBB) is required for batteries in excess of 18 amp hours. Flexput circuits on 5820XL control can be Individually programmed to function as notification circuits, auxiliary power outputs, or initiation circuits that support both 2- and 4 -wire smoke detectors. The 5820XL system operates on non - twisted, unshielded cable when wired in compliance with standard wiring practices as called out in the National Electric Code 760-51 specifications for power -limited fire protective signalling cables. No special wiring is required. 5820XL provides 13 preset notification cadence patterns (including ANSI 3.41) and four user programmable selections for fire alarm notification. Two programmable general purpose Form C relay outputs are provided on 5820XL. Additionally, the IntelliKnight system features a built-in walk test and auto - programming. Its innovative, dead -front cabinet design allows for flush or surface mounting. System maintenance is easy to perform. User Interface The 5820XL built-in annunciator with 80 character LCD display and large easy-to-use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1000 events for viewing from the built-in or remote annunciator. System operation can be initiated with a mechanical firefighter's key or a valid 4- to 7 -digit operator's code. Programming The IntelliKnight system offers several options to simplify and speed up programming. The JumpStarta' feature minimizes programming required to start a new system. The built-in keypad and 5860 remote annunciator give on-site access to all programming. You can also program remotely using the 5660 Silent Knight Software Suite, which is Windows& based software. Built -In Digital Communicator 5820XL features a built-in UL listed digital communicator for remote reporting of system activity and system programming. The communicator has the ability to seize two telephone lines to report alarms and troubles to a monitoring facility. The communicator supervises two phone lines and will activate a trouble signal if a line failure is sustained for more than 45 seconds. Other communication features include: retry if communication fails, two phone number capability, download phone number capability and Touch -Tone or rotary dialing. The communicator is compatible with SIA and Ademco Contact ID. The format is selectable by account number. Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, water8ow, sprinkler supervisory (DACT non -coded) signalling services. Other Approvals: UL Listed; CSFM 7170-0559: 135; MEA 429-92-E Vol. VI; FM Approved IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel IntelliKnight 5820XL w"dradity Addressable Fire Alarm System "°"°eem n'som.a SK (System Sensor) Protocol Devices wndows Beard IR(A is Ndma4lo SK PUI-M .211-6A MalOo Iwd BK-MNmdO 8KRelW4 BKS . w.ed,p l.Mwl ROYy CaM01 pl —.. /.dIi ye AggyYpp Softer. 111-1e —► H61 ► Compatble CS fil— 9e+m Dd•tlJ Receiver P"I S1®OY Ddalo ftwen SOR.,e; wp t In—tercet s o SK -MUD cmnecnOR Ma«aama _J IP COmmunicalor 5880 Remmuannurae:ol CN W rnpNe ' > MPY[6 W qwb O Dorca.F v°an x aa aolae W+.AAOR .11 MOENeWMn.p W44.1AT R°ae ease M as tle NRIJYa�bl� BK -Beam 81(48 T l IR(A is Ndma4lo SK PUI-M .211-6A WZMI --Oe BK-MNmdO 8KRelW4 BKS . w.ed,p l.Mwl ROYy CaM01 pl —.. /.dIi ye AggyYpp Monau 111-1e MI, M ON NNuh In'A OMB pMq 9e+m Dd•tlJ MJOY!a P"I S1®OY Ddalo MYJu• MaEY'e I Uce d1e 5580 to conrrOl.P tO4 083 Relay Interface M.O. 5R85dar 5885) IFAAmuraiav Imase so.") IntelliKnight Model 5820XL Addressable Fire Alarm Control Panel Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.5A or 240 VRMS at 50/60 Hz, 1.4A Total Accessory Load: 6A @ 27.4 VDC, power -limited Standby Current: 215 mA Alarm Current: 385 mA Flexput Circuits: Six programmable circuits which can be programmed individually as: Notification circuits: 3A @ 27.4 VDC per circuit, power -limited Auxiliary power circuits: 3A @ 27AVDC per circuit, power -limited Initiation Circuits: 100 mA @ 27AVDC per circuit, power limited Physical Flush Mount Dimensions: 14.5"W x 24.75"H x 3.9"D (36.8Wx62.9Hx9.8Dcm) Overall Dimensions: 16.2"W x 26.4"H x 4.2"D (40.6 W x 67 H x 11.8 D cm) Weight: 28 lbs. (12.8 kg) Color: Red Battery Charging Capacity: 7.0-35 AH Battery Size: 18 AH max allowed in control panel cabinet. Larger capacity batteries can be housed in RBB accessory cabinet. Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) S -BUS Accessories 5860/R Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's keyswitch as the 5820XL. 5860 is gray and 5860R is red. 5815XL Signal Line Circuit Expander The SLC expander is used to add more addressable devices to the IntelliKnight system. 5820XL supports three 5815XUs. Each 5815XL can support 99 SK detectors and 99 SK modules or 127 SD devices. 5895XL Intelligent Power Module Adds 6 amps of power, 6 Flexput 1/0 circuits and 2 Form C relay circuits to a 5820XL system. 5496 Intelligent Power Module A 6 amp notification power expander that provides four power -limited notifi- cation appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs, and one piezo output. 5865.3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs, and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS -232 serial port for connecting a printer to the 5820XL. Use to print a real-time log of system events, detector status reports, and event history. Interfaces with building control system. Miscellaneous Accessories 5660 Silent Knight Software Sults (SKSS) User-friendly Windows software for remote programming of 5820XLs using a PC. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite (SKSS) Powerful end-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-1 Dead front cabinet door with clear window to limit access to the FACP. RBB Remote battery box accessory cabinet. Use if backup batteries are too large to ft into FACP cabinet. Dimensions: 16"W x 10" H x 6" D (406 mmWx254mmHx152mmD) SD505-DTS-K Remote test switch. Used with SD505-DUCTR. Provides remote key operated test function and annunciation of detector alarm. SD and SK Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices Data Sheet 53623 SK Devices Data Sheet ® SILENT This document is not Intended to be used for Installation purposes. We try to keep our Made In America KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. m For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472 PN 350210 Rev H2 by Honeywell Phone: (203) 484-7161, Fax: (203) 484-7118. www.sllentknlght.com. ® 2012 Honeywell International Inc. IntelliKnight & Jumpstart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight Model 5495 SILENT KNIGHT Distributed Power Module ® In an emergency, by Honeywell you need maximum power The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday — what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features • UL Listed for 6 amps of notification power • Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems • Dip switches allow for easy reconfiguration • 24 VDC filtered output voltage • Four power -limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B • Additional continuous auxiliary output • 3 amps per output circuit • 2 inputs; 2 Class B or 2 Class A • Ground fault detector/indicator • Independent trouble relay • AC loss delay option shuts off power to non-essential high -current accessories like magnetic door holders • Built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday • Stand alone operation • Lightweight design adds to ease of installation and reduces shipping costs • Operates with most polarized, UL Listed notification devices • ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the Inputs on the 5495. The control panel's notification circuit end -of -line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kd2 end -of -line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals • UL Listed • MEA429-92-E Vol XII • CSFM 7300.0559:123 • NFPA 72 • OSHPD (CA) OSP-0065-10 (see accessories) PN 350395 Rev G © 2015 Honeywell International Inc. Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal 1 Input Distributed Signal Circuit Output Signal 2 Power .-Input Module 5495 Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision The 5495 supervises a variety of functions including: • Low AC power • Low battery condition • Earth ground fault • Auxiliary output power limit condition • EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification • 4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0 (6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panel's notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit - 15 mA: Both input circuits - 30 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 35.0 AH Ambient temp.: 32° to 120° F (0° to 49° C) Signal 1 —Signal 2 Signal 3 Signal 4 —Aux. Power Aux trouble: Yellow Output troubles (1-4): Yellow Ordering information 5495 Distributed Power Module Accessories: SK -SCK Seismic Compliance Kit AC input: 120 VAC at 2 amps Mechanical Output: 24 VDC at 6 amps Dimensions: Current: 12.25" W x 16" H x 3" D (30.88 cm W x Standby 75 mA 40.64 cm H x 7.62 D cm) Alarm 205 mA Auxiliary power circuit: 1 Indicator Lights Notification circuits: 4 AC power on: Green Battery trouble: Yellow Output configuration: • 2 Class A (Style Z) Ground fault: Yellow SILENT This document is not intended to be used for installation purposes. We try to keep our product information up -lo -date and accurate. We cannot cover all KNIGHT ® specific applications or anticipate all requirements. All specifications are = subject to change without notice. For more information, contact Silent Knight -_ by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, sai Fax: (203) 484-7118.For Technical Support, please call 800.446-6444. Assembled In America www.slientknight.com *- SYSTEM �4 SENSOR Outdoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrkerlO Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features • Weatherproof per NEMA 4X, IP56 • Listed to UL 1638 (strobe) and UL 464 (horn) • Compatible with System Sensor synchronization protocol and legacy SpectrAlert products • Field -selectable candela settings: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candola • Rotary switch for horn tone and three volume selections • Horn rated at 88+ dBA at 16 volts • Rated from -40OF to 151 OF • Universal mounting plate with an onboard shorting spring that tests wiring continuity before devices are installed • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Listed for ceiling or wall mounting SpectrAlert Advance offers the broadest line of outdoor horns, strobes, and horn strobes in the industry. With white or red plastic housings, wall or ceiling mounting options, and plain or FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement, including indoor, outdoor, wet, and dry applications in temperatures from -40OF to 151 OF Like the entire SpectrAlert Advance line, outdoor horns, strobes, and horn strobes for wall applications include a variety of features that increase application flexibility and simplify installation. First, field -selectable settings, including candela, automatic selection of 12- or 24 -volt operation, horn tones, and three volume options enable installers to easily adapt devices to meet requirements. Next, SpectrAlert Advance devices use a universal mounting plate for both wall and ceiling applications. This mounting plate includes an onboard shorting spring that ensures wiring continuity before devices are installed, so installers can verify proper wiring without mounting the devices and exposing them to potential construction damage. Once the plates are mounted, all SpectrAlert Advance devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes (metal back boxes are available separately) that accommodate in -and - Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater SIGNALING corrosion. Knock -outs located on the back eliminate the need to drill Y� holes for screw-in mounting. Plastic and metal weatherproof back F M MEA-,�,-s5s,a, boxes come with 34 -inch top and bottom conduit entries and %-inch LISiEO (ou•�.Or so-ohP.) roved—.25-,653169(hvn sVCb.s. approved knock -outs at the back. A screw-in NPT plug with an O-ring gasket 840 11 (Chimes, horn 940CP5, hOr^s) 4>PAOVEO 53593 (Oad.r Bnd eO,l sVOb.$) 3323512 ch'rra-Ob80) MEA452-05,E „35-1653.lag (hvn4 &mss) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe, and Horn Strobe Specifications General SpectrAlert Advance outdoor horns, strobes, and horn strobes shall mount to a weatherproof back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuit" Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 17 and 33 volts. Outdoor SpectrAlert Advance products shall operate between -40 and 151 degrees Fahrenheit from a regulated OC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options shall be set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn or horn strobe models shall operate on a coded or non -coded power supply. The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use In wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F (-401C to 66°C) Strobe Flash Rate 1 flash Der second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR' Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18AWG Wall -Mount Dimensions (Including lens) 5.6"L x 4,7"W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Weatherproof Back Box Dimensions (SA-WBB) 5.7"L x 5.1"W x 2.0"D (145 mm L x 130 mm W x 51 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. Avosoi2m UL Current Draw Data RUNIIJUNIUMMOffrF M-1111TIMMMANIII 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal Candela 8-17.5 Volts DC FWR 16.33 Volts DC FWR Standard 15 123 128 66 71 Candela 15175 142 148 77 81 Range 30 NA NA 94 96 69 75 NA NA 15B 153 60 95 NA NA 181 176 50 110 NA NA 202 195 69 115 NA NA 210 205 High 135 NA NA 228 207 Candela 150 NA NA 246 220 Range 177 NA NA 281 251 RUNIIJUNIUMMOffrF M-1111TIMMMANIII 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non -Temporal High 57 56 69 75 Non -Temporal Medium 42 50 60 69 Non -Temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 Temporal High 8-17.5 Volts Temporal 16-33 Volts 97 112 168 190 210 218 Temporal Medium 129 152 DC Input 15 15/75 15 15!75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 Temporal High 136 155 Temporal 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 135 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 88 85 95 110 166 189 208 216 Non -Temporal Low 132 154 High 80 90 105 161 184 202 211 UL Max. Current Draw 101 101 177 177 8t Coded Medium 78 16-33 Volts 85 85 90 16-33 Volts 97 98 DC input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures, listed Horn and Horn Strobe Output •6-175 candela ratings must be reduced in accordance with 16.33 24 -Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic ZO Z Position Pattern dB DC FWR DC FWR DC FWR OC FWR Listed Candela Candela rating at -)0°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15[75 Do not use below 320F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 78 78 85 85 90 90 98 98 Temporal 115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 8t Coded Medium 78 78 85 85 90 90 97 98 185 185 91 Coded Low 75 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2 -wire horn strobe. AVDSo12m SpectrAlert Advance Diagrams Wall -Mount Horn Strobes r.� erproof Back Box Wall -Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description P21`tK't 2 -Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P2RHK`t 2 -Wire Horn Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) P2WK`t 2 -Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2WHK`t 2 -Wire Horn Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) P4RKt 4 -Wire Horn Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) P4WK 4 -Wire Horn Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) P2RHK-120 2 -Wire Horn Strobe, High cd, Red. Outdoor, 120 V (includes plastic weatherproof back box) SRK`t Strobe, Standard cd, Red, Outdoor (includes plastic weatherproof back box) SRHK't Strobe, High cd, Red, Outdoor (includes plastic weatherproof back box) SWK" Strobe, Standard cd, White, Outdoor (includes plastic weatherproof back box) SWHK'* Strobe, High cd, White, Outdoor (includes plastic weatherproof back box) Homs HRKt Horn, Red, Outdoor (includes plastic weatherproof back box) Accessories SA-WB8 Red, Metal Weatherproof Back Box White, Metal Notes: Add "-P" to nodal number for plain housing (no "FIRE" marking on cover), e.g.. P2RK-P. t Add "-R" to model number for weatherproof replacement device (no back box included), only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. "Standard cd" refers to strobes that include 15.15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 •Fax: 630-377-6495 e,� ;, ®zmz sr a sa .«. SENSOR' ,<. ,, «�a ., '«<u,•«,�gm";emi«,regia,,DS01201 e,i„eu..,:�«,nw,a,�a sn�i. avosmzm •3nz SYSTEM �4 SENSOR Selectable -Output Low Frequency Sounder and Low Frequency Sounder Strobes for Wall Applications SpectrAlertO Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • 520 Hz x 10% square wave tone • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Field -selectable candela settings on wall units: 135, 150, 177, and 185 • Rotary switch for low frequency sounder tone • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically compatible with legacy SpectrAlert devices • Compatible with MDL3 sync module • Listed for ceiling or wall mounting ( r F R E E t The SpectrAlert Advance series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes In the industry. With white and red plastic housings, dual listed for wall and ceiling mounting, SpectrAlert Advance can meet virtually any application requirement. The wall -mount low frequency sounder, and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz 3 10% and is of a square wave tone. Like the entire SpectrAlert Advance product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can lest wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, Agency Listings automatic selection of 12- or 24 -volt operation, and a rotary switch for 520 Hz low frequency sounder tones, slsaauas F M MEA 118TE0 .v.•ovcn approved W11 (sw,MeQ E5512(0.Ea) 3'NM3 MEA452 a5 7135-16530223 712516530220 SpectrAlert Advance Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1'/r -Inch back box, 4 -Inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8 -inch back box, A universal mounting plate shall be used for mounting products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync -Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field -selectable candela settings including 135, 150, 177, and 185. The field selectable tones will sound within the frequency range of 520 Hz f 10% square wave tone and have a permanent marking on the housing that reads "low frequency sounder", Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts (includes fire alarm panels with built in sync). When used with the Sync -Circuit Module MDL3, 12 -volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24 -volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three pattern, non -temporal (continuous) pattern and coded supply within the frequency range of 520Hz x 10% square wave tone. The low frequency sounder shall operate on a coded or non -coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non -coded power supply. The field selectable tones will sound within the frequency range of 520 Hz m10% square wave tone. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service, The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 411/,6 x 411/16 x 2'/s -inch back box. The module shall also control two Style Y (class D) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. 32°F to 120°F Humidity Range 10 to 93% non -condensing Frequency Range 520 Hz t 10% Strobe Flash Rate 1 flash Der second Nominal Voltage Low Frequency Sounder Requlated 12 DC/FWR or reaulaled 24 DC/FWR' Nominal voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR' Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall -Mount Dimensions (Including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (SBBR, SBBW) 062 mm L x 119 mm W x 64 mm Dl Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 Inches D (142 mm L x 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions (SBBR, SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR, SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that Is used on some power supply and panel outputs. UL Current Draw Data UL Max. Low Frequency Sounder Current Draw (mA RMS) 8-1x5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 191 262 138 166 Continuous High 292 384 138 208 292 388 UL Max. Current Draw (mA RMS), 2 -Wire Low Frequency Sounder Strobe, High Candela Range Volts 16-33 Volts Reverberant 1633 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 277 292 325 344 Temporal 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data 8-17.5 16-33 24 -Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC Advance Dimensions N4.7 in.� 7 6.4 In. Wall -mount low frequency sounder strobes SpectrAlert Advance Ordering Information Wall -mount low frequency sounder Wall Low Frequency Sounder Strobes P2RH-LF 2 -Wire Low Frequency Sounder Strobe, High cd, Red P2WH-LF 2 -Wire Low Frequency Sounder Strobe, High cd, White Low Frequency Sounders HR -LF Low Frequency Sounder, Red HW -LF Low Frequency Sounder, White SSBR Surface Mount Back Box, Wall, Red SBBW Surface Mount Back Box, Wall, White TR -HS Trim Ring, Wall, Red Notes: "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ®m ssyse*se so. SENSOR Phone: 800 SENSOR2 •Fax: 630-377-6495 Prweaw1m ,e lllf —Wn,—W111< o noa. 'dN,fts �,V �«w[ p cabWIn�wUret q N,had Reb@aca. VS[stlte, 9�c www.systemsensoccom AVDS164N.1115 SYSTEM �4 SENSOR Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrkerrP Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24 -volt operation at 15 and 15/75 candela • Field -selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and three volume selections • Universal mounting plate for wall units • Mounting plate shorting spring checks wiring continuity before device Installation • Electrically Compatible with legacy SpectrAlert devices • Compatible with MD1_3 sync module • Listed for ceiling or wall mounting Agency Listings SIGNALING q w7o ��� LISTED 5901 I(cFimes. hmn tlmbee, SM12(slmbes) AF Mrs) 3023572 approved MEAOM5-E 7125-1653 186 (,naoor.LOFe,( 712&1653 IN(,orn Iv b.% cFime aV.bes) 7135-1653.189 (�oms. chimes( X44 F q /. The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE -printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall -mount horns, strobes, and horn strobes Include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with three volume selections. SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11h -inch back box, 4 -inch octagon back box, or double -gang back box. Two -wire products shall also mount to a single -gang 2 x 4 x 17/8 -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync•Circuif" Module accessary, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full - wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system, Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range, The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. On four -wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8 -inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control, The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32-F to 120-F (0-C to 49°C) I flash per second or regulated 24 Operating Voltage Range' 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDU Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Well -Mount Dimensions (Including lens) 5.6"L x 4.7"W x 2.5"D (142 mm L x 119 mm W x 64 mm 0) Horn Dimensions 5.6"L x 4.7"W x 1.3"D (142 mm L x 119 mm W x 33 mm D) Wall -Mount Trim Ring Dimensions (sold as a 5 pack) (TR -HS) 5.7"L x 4.8"W x 0.35"D (145 mm L x 122 mm W x 9 mm Dl Notes: 1. Full Wave Rectified EER) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. P, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data Temporal High 8-175 Volts 15-33 Volts 88 97 112 8-17.5 V0lts 190 16-33 Volts Candela DC FWR DC 78 FWR 103 Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 160 71 194 Temporal High 57 55 103 69 75 Candela 15/75 142 148 77 Non -Temporal Medium 81 155 Temporal Medium 44 49 189 58 69 Range 30 NA NA 94 90 Candela 185 96 161 Temporal Low 38 44 245 259 44 48 75 NA NA 158 258 153 Temporal Medium Non -temporal High 57 56 Temporal Medium 69 75 95 NA NA 181 101 176 Coded Non -temporal Medium 42 50 85 60 69 110 NA NA 202 Low 195 75 Non -temporal Low 41 44 96 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, 8-17.5 Volts 16-33 Volts DC Input 15 15!75 15 15!75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non -Temporal High 141 152 91 100 116 176 201 221 229 Non -Temporal Medium 133 145 75 85 102 163 187 207 216 Non -Temporal Low 131 144 68 79 96 156 182 201 210 Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non -Temporal High 142 161 103 112 126 181 203 221 229 Non -Temporal Medium 134 155 85 95 110 166 189 208 216 Non -Temporal Low UL Max. Current Draw (mA DC Input 132 RIAS), 2 -Wire 16-33 Volts 135 150 154 Horn 80 Strobe, High 177 90 Candela 185 105 Range 1135-185 cd) FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 Non -Temporal 290 297 Temporal High 81 215 231 258 265 Temporal Medium 235 253 7t 288 297 Temporal Medium 82 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non -Temporal High 255 270 303 309 Non -Temporal High 233 248 275 281 Non -Temporal Medium 242 259 293 299 Non -Temporal Medium 219 232 262 267 Non -Temporal Low 238 254 291 295 Non -Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC FWR 15-33 Volts DC FWR 24 -Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non -Temporal High 82 82 88 88 93 92 100 100 5 Non -Temporal Medium 78 78 85 85 90 90 98 98 6 Non -Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8r Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 iSettings 7, 8, and 9 are not available on 2 -wire horn strobes Advance Dimensions 3" Wall -mount horn strobes SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2R 2 -Wire Horn Strobe, Standard cd, Red P2R-P 2 -Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2 -Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2 -Wire Horn Strobe, High cd, Red P2RH-P 2 -Wire Horn Strobe, High cd, Red, Plain P2W 2 -Wire Horn Strobe, Standard cd, White P2W-P 2 -Wire Horn Strobe, Standard cd, White, Plain P2WH 2 -Wire Horn Strobe, High cd, White P2WH-P 2 -Wire Horn Strobe, High cd, White, Plain P4R 4 -Wire Horn Strobe, Standard cd, Red P4R-P 4 -Wire Horn Strobe, Standard cd, Red, Plain P4RH 4 -Wire Horn Strobe, High cd, Red P4W 4 -Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR -P Strobe, Standard cd, Red, Plain SR -SP Strobe, Standard cd, Red, "FUEGO" Wall Strobes (cont.) SRH Strobe, High on, Red SRH -P Strobe, High cd, Red, Plain SRH -SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW -P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns Red HW Horn, White Accessories TR -HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have TUEGO" marking on cover "Standard cd" refers to strobes that include 15.15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 02014 sye!eT Sen.or. Phone: 800-SENSOR2 • Fax: 630-377-6495 SENSOR' "e•, sig, oere x roacemv, •,ema mm wsystemsensoccom Icr<w=n,pmuol'm,wmtiwnv,D81M - 1114 versirnd Nis date Aea,. SYSTEM SENSOR" Indoor Selectable - Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features R E • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24 -volt operation at 15 and 30 candela • Field -selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only Agency Listings SIGNALING M <�> Roveo 0 LISTED 55512 FM approvw axcep� 5305p1 Se011 Iw XI RT, dd. ;I2i A=3M 305]303.3057072 The System Sensor L -Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L -Series can meet virtually any application requirement. The L -Series line of wall -mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L -Series utilizes a universal mounting plate for all models with an onboard shorting spring, so Installers can test wiring continuity before the device is installed, Installers can also easily adapt devices to a suit a wide range of application requirements using field -selectable candela settings, automatic selection of 12- or 24 -volt operation, and a rotary switch for horn tones with two volume selections. L -Series Specifications General L -Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/s -inch back box, 4 x 4 x 1'h -inch back box, 4 -inch octagon back box, or double -gang back box, L -Series compact products shall mount to a single -gang 2 x 4 x 17A -inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L -Series products, when used with the Sync•Circuit' Module accessory, shall be powered from a non -coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync -Circuit Module, 12 -volt -rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24 -volt -rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L -Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full -wave rectified unfiltered power supply. Strobes and horn strobes shall have field -selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L -Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L -Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary -signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non -temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non -coded power supply. Synchronization Module The module shall be a System Sensor Sync -Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21B -inch back box. The module shall also control two Style Y (class R) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120-F (0-C to 49°C) Humidity Range 10 to 93% non -condensing Strobe Flash Rate 1 flash Der second rvommar vonage Hegulated 12 DC or regulated 24 DC/FWW.2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDU Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Terminal Wire wan -mourn urmensions pncmamg rens) b.b- L x 4.7'" W x 1.91-D (143 mm L x 119 mm W x 49 mm D) Compact Wall -Mount Dimensions (Including lens) 5.26" L x 3.46" W x 1.91" D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.25"D (143 mm L x 119 mm W x 32 mm D) Compact Horn Dimensions 5.25" L x 3.45" W x 1.25'D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time -varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. UL Current Draw Data 8-17.5Volts 16-33Volts DC DC FWR Candela 15 88 43 60 Range 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 Sound Pattern dB 8-17.5 Volts DC 15-33 Volts DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non -Temporal High 43 47 54 Non -Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non -Temporal High 42 43 54 3.1 KHz Non -Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Max. Current Draw (mA RMS), 2 -Wife Horn Strobe, Candela Range (15-115 cd) 197 235 283 3.11K Temporal High 81 8-115 Volts 155 16.33 Volts 196 234 284 31K Temporal Low 68 DC Input 75cd 30cd 75cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non -Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non -Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non -Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 75cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non -Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.11K Temporal High 81 105 155 177 196 234 284 31K Temporal Low 68 90 145 166 186 222 276 3.1K Non -Temporal High 104 131 177 204 230 264 326 3.1K Non -Temporal Low 77 102 156 177 199 234 291 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Volts DC 16-33 Volts DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non -Temporal High 85 90 90 4 Non -Temporal Low 76 84 B4 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non -Temporal High 84 89 89 8 3.1 KHz Non -Temporal Low 77 83 83 9' Coded High 85 90 90 10' 3.1 KHz Coded High 84 89 89 Settings 9 and 10 are not available on the 2 -wire horn strobes L -Series Dimensions 1.91 3.46 1.25 IIIIIIIIII 11 ,1 r, .v.l.r,r. 5.27 0 Compact Strobe / Horn Strobe _ 1 ice— j1l I/9 ori q. L -Series Ordering Information Wall Horn Strobes P2RL 2 -Wire, Horn Strobe, Red P2WL 2 -Wire, Horn Strobe, White P2GRL 2 -Wire, Compact Horn Strobe, Red P2GWL 2 -Wire, Compact Horn Strobe, White P2RL-P 2 -Wire, Horn Strobe, Red, Plain P2WL-P 2 -Wire, Horn Strobe, White, Plain P2RL-SP 2 -Wire, Horn Strobe, Red, FUEGO P2WL-SP 2 -Wire, Horn Strobe, White, FUEGO Wall Strobes SBBRL SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, While, ALERT 3.46 1.25 0 0°0°A°A A 1 0 0a0 00000 .27pop°pApAeA° AAAAAIAAAAAAv I°AA11A°A°I° AIIt111111A1A IIIIIIA111111 It11111 1 Compact Horn Horn Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO'marking on cover All -ALERT models have "ALERT" marking on cover SYSTEM 3825 Ohio Avenue I St. Charles, IL 60174 CM17 S Mn. oar„or. Z-4 SENSOR' Phone: 800-SENSOR21 Fax: 630-377-6495 nm.= r<. wttrmm A ro . vsu":,.ms.,,.or,,= Iwcunenrpw.,:rmrnrreew,,ir Avory Re �ereuvers�.v,dmlcasu xneH. wwwsystemsensor.com nvosessola • °arn Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HOWL Compact Horn, White Accessories TR -2 Universal Wall Trim Ring Red TR -2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE" marking on cover) All -SP models have "FUEGO'marking on cover All -ALERT models have "ALERT" marking on cover SYSTEM 3825 Ohio Avenue I St. Charles, IL 60174 CM17 S Mn. oar„or. Z-4 SENSOR' Phone: 800-SENSOR21 Fax: 630-377-6495 nm.= r<. wttrmm A ro . vsu":,.ms.,,.or,,= Iwcunenrpw.,:rmrnrreew,,ir Avory Re �ereuvers�.v,dmlcasu xneH. wwwsystemsensor.com nvosessola • °arn dn-3459:al • K-200 STI Stopper® 11 and NOTIFIER° Weather Stopper® 11 j6V Covers for Manual Pull Stations by Honeywell Miscellaneous General The Safety Technology International, Inc. Stoppers II cover for manual pull stations helps deter unwanted activation and is also an effective guard against physical damage. It has been proven by use in thousands of installations throughout the world, Including schools, hospitals, hotels and stores. The Stopper® II has also been tested and approved by fire prevention and testing authorities. Features • Window made of clear and durable plastic. • Optional warning horn powered by 9 VDC battery. • Provides weatherproofing for outdoor pull stations when equipped with optional gasket (Weather Stopper 11). • Fits pull stations from 5-1/2" to 6.3/4". • Unconditional lifetime guarantee against cover breakage and damage. Applications The Stopper® II can be used in almost any pull station environment. Spacer Installation (SURFACE MOUNT MODELS ONLY) The spacer is used for surface -mounted or oversized manual stations. Longer screws are provided for use with tap -in anchors. Remove knock -out at top or bottom of spacer as necessary. Gasket Installation (WEATHER STOPPER® 11 MODELS ONLY) Installing neoprene gaskets behind the spacer and/or Stopper® II frame will provide additional weatherproofing. A conduit gasket may be used to seal the top or bottom of the spacer. (159 ve• z• cm) (5.06 cm) T T.TB an I,I 5314'(14.66 cm) zaa• (6.98 cn) ILII Srhbp S p b LIFTHERE Mot —f SPACE11 OPTIONAL Part No. 3166 Size Of Pull Station Accomodated The Stopper® II and Weather Stopper®11 can be Installed over a flush -mounted station up to 6.1/2" wide and 6-3/4' high. However, the pull station's maximum dimensions will decrease as its depth (distance from the wall) Increases, Le.: a 3/4" deep pull station may be 5-1/2" wide x 6' high; a 1-5/8" deep pull station may be 5" wide x 6" high; a 2-3/8" deep pull station may be 4' wide x 5-3/4" high; a 2-3/4' deep pull station may be 3" wide x 5-1/2" high. See sections "Spacer Installation" and "Gasket Installation". Agency Listings and Approvals These listings and approvals apply to the modules specified In this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be In process. Consult factory for latest listing status. • UL Listed: S2466 • ULC Listed: S2466 • ADA Compliant • STI -1100 & STI -1130: Factory Mutual Approved • STI -1100 & STI -1130: BSA: 947 -81 -SA • STI -1100, STI -1130, STI -1250, STI -3150: CSFM AHJ Approval Required • STI -1200, STI -1230, STI -1250: MEA 49.00-E • STI -1250, STI -3150: NEMA -3R When mounted on a smooth surface or when mounted with STI- 1280 Back Plate do -3459: a1 •2/26/10 —Page 1 of 2 Product Line Information STI.1100Stopper0 II, flush mount, with horn. STI.113OStopper® II, surface mount, with horn. STI-1200Stopper® II, flush mount, without horn. STI.1230Stopper® II, surface mount, without horn. STI-1250Weather Stopper® II, flush mount. STI.3150Weather Stopper® II, surface mount. MANUAL NEOPRENE PULL CONOUITGASKET ar weatherproof STOPPER II COVER STATION around Clear LEXAM MOVABLE INSERT per11w.300�. pad 3003. ultraviolet stabilized. to toamtatko. ConduO 1 lop ar botlam. p ®/ HORN 05 as at 10 X. a 16 Power am" Weather Stoppero II (at left) 9 VW battery LOCKOUTSCREW NEOPRENE GASKETused RETAINING ACTIVATIOW to weatherproof CABLE DEACTIVATION SWITCH Stopper ll. 400 lb. breaking FRAME strength. (Red LEXAN®1 Screws add Anctwrs SPACER (Rod LEXAN®I used only \ proMdetl with Spacer. \®✓ Man manual Fire Alarm Station is surface-mounted(order separately). Stoppero II (at right) MANUAL PLASTIC PULL INSERT STATION NEOPRENE ✓ CONDUITGASKET I used 10 sea! .round Oor dult to weatherprool (path do. 30(K). NEOPRENE GASKET (part no. 3002). SPACER (red Poiyce�sed only when manual Fire AMrm Stenon is NEOPRENE surface-mounted(pad no. 3100). GASKET (part no. 3002). MER STOPPER II COVER rodded Polycadwnate rlolet stabilized). RETAINING CABLE -4001b. breakingstrength. _ FRAME (Polycarborete) Screws and Anch,rs / Pwidetl wilt Sparer. i usid3,wm1 NOTIFIER® is a registered trademark of Honeywell International Inc, ®2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I® This document is not intended to be used for la purposes. We try to keep our product Information up-to-datlIat e andnd accurate. We cannot cover all specific applications or anticipate all requirements. ENNNEERINR N MANRfAR1URIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made In the U.S. A. For more information, contact Notifier. Phone: (203) 481 FAX: (203) 484-7118. www.notifieocom Page 2 of 2 — dn-3459:a1 •2/20/10 SILENT KNIGHT by Honeywell SK -Heat, SK -Heat -HT and SK-Heat-ROR Addressable Thermal Heat and Rate -of -Rise Detectors The SK -Heat, SK -Heat -HT, and SK-Heat-ROR are plug in thermal detectors, with integral communication, that provide features that surpass conventional detectors, These thermal detectors are for use with Silent Knight IntelliKnight series Fire Alarm Control Panels (FACPs). IntelliKnight heat detectors are an essential component in virtually any IntelliKnight installation. The IntelliKnight panel recognizes each detector by its specific address, so precious seconds are not wasted in determining location of an alarm. Description SK -Heat, SK -Heat -HT and SK- Heat-ROR are intelligent sensors that utilize a state -of -the art thermistor sensing circuit for fast response. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK -Heat is a fixed temperature sensor that uses a thermistor sensing circuit to produce 135°F (57°C) fixed temperature alarm. SK -Heat -HT is a variable high temperature detector that provides high temperature detection at 135°F - 190°F. (57°C - 88°C) SK-Heat-ROR is a rate -of -rise temperature sensor with 135°F (57°C) fixed temperature alarm. Features • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Innovative thermistor sensing circuit • Superior EMI resistance for reliability • Variety of mounting options to meet any application • Dual LED indicators for 3600 visibility • Detector transmits signal to indicate maintenance is required • Plug-in mounting provides ease of Installation • Optional remote LED annunciator (System Sensor' PN RA100Z) • Tamper -proof feature available on mounting bases • Rotary address switches for fast installation - UL Listed Specifications Physical Height: 2.0" (51 mm) Diameter: 6.1" (155 mm) installed in B21OLP base Shipping Weight: 4.8 oz (137 g) Electrical Operating Voltage: 15 to 32 Volts DC Peak Standby Current: 300pA @ 24 VDC LED Current: 6.5 mA@ 24 VDC Environmental Operating Temperature SK -Heat & SK-Heat-ROR: -4° — 100°F (-20°C— 38°C) SK -Heat -HT -40 — 150°F (-20°C — 66°C) Humidity: 10% — 93% noncondensing Thermal Ratings SK -Heat: Fixed temperature alarm 135-F (57°C) SK -Heat (base included) SK -Heat -HT High temperature heat sensor 135°F - 190°F (57°C - 88°C) SK-Heat-ROR: Rate -of -rise detection 15°F/min (8.31C/min) Compatibility The SK -Heat -HT and SK-Heat- ROR are compatible with the following IntelliKnight FACP's: 5820XL 5808 5700 The SK -Heat is compatible with the following IntelliKnight FACP's: 5820XL 5808 5700 5600 (Rev 2.0 or higher) The SK -Heat, SK -Heat -HT and SK- Heat-ROR are compatible with the following detector bases: B21OLP 6" base (included) B501 2 wire base B224BI Isolator base B224RB Relay base B200SR Sounder base Model SK -Heat, SK -Heat -HT, SK -Heat ROR Addressable Thermal and Rate -of -Rise Thermal Detectors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent Thermal Sensor Silent Knight Model SK -Heat, SK -Heat -HT or SK-Heat-ROR. The base included shall be B210LP. The Heat detector shall have a Flashing status LED for visual supervision. When the detector is activated, the flashing LED will latch on steady at full brilliance. The detector may be reset by actuating the control panel reset switch. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be Feld removable when not required.Voltage and RF/transient suppression techniques shall be employed to minimize false alarm potential. Wiring SK-Serles Detector Mounting Bases Accessories M02.09-00 - Test Magnet with Telescoping Handle. RA10OZ - Remote LED Annunciator. RMK400 - Recessed Mounting Kit. Provides low profile for use with B501. XR2B - Detector Removal Tool. A removal and re- placement tool for SK plug -In detectors. Includes the T55-127.000. M02-04-01 - Replacement Test Magnet. XP -4 - Extension Pole for XR28. Extends from 5 —15 ft. T55-127-000 - Detector Removal Head. BCK-200B - Black Detector Kit. For SK -series detectors. . Unless otherwise noted, specifications apply to all SK thermal detectors. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject FORM# 350120 Rev. D1 13. to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road Northford, CT 06472-1610 Phone: (800) 328-0103, ®2013 Honeywell International Inc. Fax: (203) 484-7118. For Technical Support call 800-446.6444. www.silentknight.com SILENT SK -Monitor KNIGHT a� by Honeywell Intelligent Monitor Module The SK -Monitor module provides an interface to contact devices, such as security contacts, waterflow switches, or pull stations. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK -Monitor is an addressable monitor module for use with Silent Knight IntelliKnight series fire alarm control panels (FACPs). The SK -Monitor is intended for use in intelligent, two -wire systems, where individual address of each module is selected using the built-in rotary switches. The SK -Monitor supports Class A supervised or Class B supervised wiring to the load device. Conventional 4 -wire smoke detectors can be monitored for alarm and trouble conditions. Features • Single contact monitor • Support for Class A and Class B wiring • Fully supervised • Panel controlled status LED that flashes green in normal state and is solid red in alarm • Attractive ivory cover plate Rotary address switches for fast installation • SEMS screws for easy wiring • UL Listed Installation The SK -Monitor mounts directly into a 4" square electrical box. The box must have a minimum depth of 2-1/8". A surface mount electrical box (System Sensor® PN SMB500) is available from Silent Knight. Compatibility The SK -Monitor is compatible with the following IntelliKnight FACP's: 5700 5808 5820XL 5820XL-EVS SK -Monitor Specifications Physical Height: 4.5" (11.4 cm) Width: 4" (10.2 cm) Depth: 1.25" (3 cm) Shipping Weight: 6.3 oz (196 g) Electrical Operating Voltage: 15 — 32 VDC Current Draw (LED on): 5.0 mA max Operating Current (LED flashing): 375 pA Model SK -Monitor Intelligent Monitor Module TO NEXT _ FROM PATEL OR DEVICE _ �-y� J 'x� t�K PRENOLt313EMOE SECURITY DEVICES ON THE SAME MODULE, MONITOR ANY NUTABER OF LL LISTED CONRLT MODULE CLORREDEVICESMAYSEUSED.DO NOT M% FRE ALARM INTL9NO, SUPERVISORY, Cfl 9 'S41 C NIECi MOOLLEii TO LB1ED LYMPATELE CONTROL PAN3S OILY SECLHRY CEVICES ON73£ SAYE MOOLLE 47X EOL IJ IJ y�!y T 'S.IGNAL LINE CROUTTI RESISTOR 1 1 'r�n3Ri• Si YOC1AlL EIR47K TWIFTEDPAIR _. B FECOMENDED WTIONS DEVICE CRCUT#DCI-NFPA STYLE S POWER UMITEDASOIIA MAX. • 11 WOO MAX INSTALLCCN➢ICr CLOEUFEDEVICS9 PER ALLWRIN3 WICHN E SUPERVISED AND POWER LIMITED MANLPACTUfBie INSTALLAOICN NSTRUCnow. 2 -Wire Initiating Circuit Configuration, NFPA Style B TO NEXT DEVICE EOL RESISTOR B INTERNALAT TERMINALS a a V FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED OOMPATISLE NOTIFIER CONTROL PANELS ONLY SIGNAL UNE URCUIT (91 D; 82VOC MA MAX. SHIEICED.T WISTED PAIR B RECOMENOED INSTALL CONTACT CLOSURE DEVICES PER ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED MANUFACTURERS INSTALLATION INSTRUCTIONS, 4 -Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5 Operating Temperature: 320F — 120°F (0°C — 49°C) sec with 47K EOL) 550 NA max @ 24 VDC (one communication every 5 Humidity: 10%— 93% non -condensing sec with EOL <1 K) Ordering Information 5.5 mA (with LED latched on) SK -Monitor Monitoring Module LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K n Accessories Initiating Device Circuit Wiring Resistance: 1,500,Q max SMB500 4" Square Surface Mount Electrical SLC Loop Resistance: 40 S2 max. Box This document is not intended to be used for installation purposes. We try to ® SILENT keep our product Information up-to-date and accurate. We cannot cover all MADE IN AMERICA KNIGHT specific applications or anticipate all requirements. All specifications are • subject to change without notice. For more information, contact Silent Knight FORM# 350131 Rev D by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, © 2013 Honeywell International Inc. Fax: (203) 484.7118. For Technical Support, Please call 8200446-6444. www.sileritknight.com MONITOR ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED DO NOT MIX MODULE FIRE ALARM INTIATING, SUPERVISORY, OR O O SECURITY DEVICES ON THE SAME MODULE, EOL RESISTOR B INTERNALAT TERMINALS a a V FROM PANEL OR PREVIOUS DEVICE CONNECT MODULES TO LISTED OOMPATISLE NOTIFIER CONTROL PANELS ONLY SIGNAL UNE URCUIT (91 D; 82VOC MA MAX. SHIEICED.T WISTED PAIR B RECOMENOED INSTALL CONTACT CLOSURE DEVICES PER ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED MANUFACTURERS INSTALLATION INSTRUCTIONS, 4 -Wire Initiating Circuit Configuration, NFPA Style D Standby Current: Environmental 400 pA max @ 24 VDC (one communication every 5 Operating Temperature: 320F — 120°F (0°C — 49°C) sec with 47K EOL) 550 NA max @ 24 VDC (one communication every 5 Humidity: 10%— 93% non -condensing sec with EOL <1 K) Ordering Information 5.5 mA (with LED latched on) SK -Monitor Monitoring Module LED Current: 5.5 mA (with LED latched on)End-of-Line Resistance: 47K n Accessories Initiating Device Circuit Wiring Resistance: 1,500,Q max SMB500 4" Square Surface Mount Electrical SLC Loop Resistance: 40 S2 max. Box This document is not intended to be used for installation purposes. We try to ® SILENT keep our product Information up-to-date and accurate. We cannot cover all MADE IN AMERICA KNIGHT specific applications or anticipate all requirements. All specifications are • subject to change without notice. For more information, contact Silent Knight FORM# 350131 Rev D by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, © 2013 Honeywell International Inc. Fax: (203) 484.7118. For Technical Support, Please call 8200446-6444. www.sileritknight.com SILENT KNIGHT by Honeywell SK -Photo, SK -Photo -T and SK-PhotoR Intelligent Photoelectric Smoke Sensors The SK -Photo is a photoelectric smoke detector, the SK -Photo -T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IntelliKnight Fire Alarm Control Panels (FACPs). For more information about the IntelliKnight system, or to locate your nearest source, please call 800-328-0103. Description Optional remote LED annunciator (System Sensor® PN RA100Z) SK -Photo and SK -Photo -T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK -Photo and SK -Photo -T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK -Photo -T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The SK-PhotoR is a remote test capable detector for use with the DNR/DNRW duct smoke detector. (not included) Features • Sleek, low -profile design • Base included • Reliable analog communications for trouble-free operation • Age resistant polymer housing • Dual electronic thermistor design on the SK -Photo -T • Superior EMI resistance for reliability • Simple field cleaning for code compliance • Variety of mounting options to meet any application • Dual LED indicators for 3600 visibility • Detector transmits signal to indicate maintenance is required • Plug-in mounting provides ease of Installation I • Tamper -proof feature available on mounting bases • Listed for use in duct applications • Rotary address switches for fast installation • UL Listed • FM Approved Specifications Physical Height: 2.0" (5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: 300 pA @ 24 VDC Maximum Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature SK -Photo: 320 — 120°F (0°C — 49°C) SK -Photo -T: 320 — 100°F (0°C — 38°C) Humidity: 10% — 93% non -condensing Other Ratings SK -Photo -T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 — 4000 fpm (0 — 20 m/sec) SK -Photo (Base Included) Installation The SK -Photo and SK -Photo -T plug into a compatible IntelliKnight-series detector base. The SK-PhotoR is a remote test capable detector head included within the DNR (W) duct smoke detector. Compatibility SK -Photo, and SK -Photo -T are compatible with the following detector bases: 8210LP 6" base (included) 8501 2 wire base B224RB Relay base B224BI Isolator base B200SR Sounderbase The SK -Photo, SK -Photo -T, and SK- PhotoR are compatible with the following IntelliKnight FACPs: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK -Photo, SK -Photo -T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight SK -Photo or SK -Photo -T with thermal. The combination detector head, and twist -lock base, shall be UL listed and compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct Interchange with SK -Photo or SK -Photo -T. Base shall be the appropriate twist -lock base part number B21OLP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal -resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK -Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Wiring SKSerles Detector Mounting Bases SILENT This document is not Intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are FORM# 350118 Rev E x subject to change without notice. For more information, contact Silent Knight © 2013 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484.7118. For Technical Support, Please call 800446-6444. www.silentkinight.com SILENT SK -Pull -SA and SK -Pull -DA KNIGHT by Honeywell Intelligent Pull Stations The SK -Pull -SA and SK -Pull -DA are a single action or dual action addressable fire alarm pull station for use with Silent Knight's IntelliKnight fire control panel. Extremely easy to operate, the SK -Pull -DA and SK -Pull -SA provide a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. For more information about the IntelliKnight system, or to locate you nearest source, please call 1-800-328-0103. Description The SK -Pull -SA is a single action pull station requiring only one motion to activate the station. The SK -Pull -DA is a dual 1 action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight Intelliknight series fire alarm control panels (FACPs). Features • Installer can open station without causing an alarm condition • Dual -color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition • Key operated test and reset lock using lock plate actuator • Key matches compatible FACP locks • Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) • Meets ADA requirement for 5 lbs maximum pull force to active • Shell, door, and handle molded from durable LEXAN® • Reliable analog communications for trouble-free operation • Braille text on station handle • Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled • Rotary address switches for fast installation • UL Listed, including UL 38, Standard of Manually Actuated Signaling System SK -Pull -SA SK -Pull -DA Compatibility The SK -Pull -SA and SK -Pull -DA are compatible with the following IntelliKnight FACP's: 5600 5700 5808 5820XL 5820XL-EVS Model SK -Pull -DA and SK -Pull -SA Intelligent Pull Stations Engineering Specifications The contractor shall furnish and install where indicated on the plans, Addressable Pull Stations, Silent Knight model SK -Pull -SA single action pull station or SK -Pull -DA, dual action pull station. SK -Pull -DA or SK -Pull -SA meet the ADAAG controls and operating mechanisms guidelines, and the ADA requirements for a 5 Ib. maximum pull force to activate the pull station. Wiring SK -Pull -SA & SK -Pull -DA Pull Stations Specifications Physical Height: 5.5' (14 cm) Width: 4" (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi -Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 15-32 VDC Average Operating Current (LED flashing): 300 pA Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 320 -120°F (0°C - 49°C) Humidity: 10% - 93% non -condensing Accessories BG -TR Optional trim ring. SB -1/0 Surface backbox SILENT This document is not intended to be used for installation purposes. We try MADE IN AMERICA to keep our product information up-to-date and accurate. We cannot cover WGHT all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent FORM# 350135 Rev C by Honeywell Knight 12 Clintonville Road, Northford, CT 06472-1610 ©2013 Honeywell International Inc. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800.446-6444. www.silentknight.com