HomeMy WebLinkAboutFS PRODUCT DATA REVISIONS 5-8-17 - 16-00482 - Campus Courtyard 2 Bld 8510 CPVC - COPPER - HANGER STEEL SIZE - SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION P FASTENERS WOOD STEEL FEATURES #905 ORDERING 3/4 thru 3" - Carbon Steel. - Mil. Galvanized. -S - - in : 3/4" - 3" CPVC pipe - 3/4" - " Steel pipe - 1/4 x11/2 lag - no pre-drill. in 3/4" - 3" CPVC - * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. AFCON " upport horizontal piping: 3/4" -3" CPVC. Support horizontal piping: 3/4"-2" Steel and Copper. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. screw - no pre-drill. 2 and Copper " " bolt min. 18 GA. pipe 1/4" or #14 Tek Screw. 3/4" - 2" Steel and Copper pipe - 1/4" or #14 Tek Screw. LISTING/APPROVAL- 203 - EX 4231, EX 2551 er these instructions #905 - UL Listed per NFPA13 Hanger Stabilize -Only CANALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 1/12 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org C 3/4 1 11/4 11/2 2 21/2 3 510 SIZE 2.125 2.312 3.170 3.400 4.010 4.320 5.320 L Fastener Dim. CL- CADCADCAD 514 OFFSET HANGER CPVC - COPPER STEEL• SIZE SYSTEM PIPE: MATERIAL FINISH PATENT No. 6,648,278. FUNCTION INSTALLATION WOOD - #905 STEEL- FEATURES #905 ORDERING 906 - 3/4" thru 3" - Carbon Steel. - Mil. Galvanized.. - -S rovid vertical ateral restraint revents upward movement of pipe that supplies a pendent sprinkler below ceiling. - including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. CPVC pipe - screw- no pre-drill. Copper pipe - Steel pipe - 1/4 x1 lag screw - 5/8 gypsum board - 1/4 x lag screw min. * 1 1/2 Offset * 3/4 and 1 pipe size a e common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * screw included - 5/16" hex head. - Part # and pipe size. # backing nut sold separately. AFCON AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 CONCRETE each = upport horizontal piping: 3/4" -3" CPVC or Copper. Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" p es listed /l and p a Stabilize vertical piping. When #905 threads are exposed in wood, install #906 backing nut. - UL Listed per NFPA13 3/4" - 3" 3/4" - 2" screw- no pre-drill. 3/4" - 2" " 1/2" no pre-drill. Thru " " 2" . 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. : Required minimum load fastener " - loose fit allows pipe to slide. " " m d with • 5(wt)+250lbs. 2 1.5000 #905 #906 Listed Restraint Listed Restraint Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 3.00 10/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 3/4 thru 2"" 3/4 thru 2"" CADCADCAD 511 CPVC - COPPER HANGERSIDE MOUNT SIZE SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION , WOOD #905 STEEL FEATURES #905 ORDERING - 3/4" thru 2" - Carbon Steel. - Mil. Galvanized. - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. - including NFPA13, 13R 13D and CPVC manufacturers instructions. Install on vertical mounting surface. in : CPVC pipe - Copper pipe - screw - no pre-drill. in CPVC pipe - Copper pipe - 1/4 or #14 Tek Screw. * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. ” AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 - - UL Listed per NFPA13. 3/4" - 2" screw - no pre-drill. 3/4" - 2" min. 18 GA. 3/4" - 2" 1/4 or #14 Tek Screw. 3/4" - 2" ” Side View - For Drawings Below Hanger - Metal Stud Hanger - Wood Stud Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCADCAD BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet Page 1 of 2 APRIL 2016 TFP1915 Worldwide Contacts www.tyco-fire.com General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. MaterialPipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 ColorOrange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP1915 Page 2 of 2 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. BLAZEMASTER is a trademark of The Lubrizol Corporation. Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com Sizes: Working Pressure: Temperature Range: Orientations: 2૔⁄૟” , 3”, 4”, 6”, 8” 10-175psi (0.7-12.1 bar) 33°-140°F (1°-60°C) 40/50(H) 20/30(H,V) The Deringer 20, 30, 40 and 50 backflow prevention valves are designed to prevent non-health/health hazard pollutants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. Rev. B UL-SPEC-001 Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com DEC 2016 GFS-310 (Formerly A-1) RESIDENTIAL AUTOMATIC SPRINKLERS MODELS GL4110 & GL4910 PENDENT RECESSED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profi le yet durable design which utilize a 3mm fran- gible glass ampule as the thermosensitive element. They feature economy, aesthetics and low fl ow. The combination of the 3mm frangible glass ampule and spe- cially designed defl ector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fi re control. These Globe Pendent and Recessed Pendent Residential Sprin- klers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc- tion of the approving authorities having jurisdiction. The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres- sure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern. The sprinkler and escutcheon are not factory assembled. Assembly is done in the fi eld. RESIDENTIAL PENDENT RESIDENTIAL RECESSED PENDENT TECHNICAL DATA • See reverse side for Approvals and Specifi cations. • Temperature Rating - 155°F (68°C), 175°F (79°C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Defl ector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - tefl on • Bulb - glass with alcohol based solution, 3mm size • Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE 155°F 175°F 68°C 79°C RED YELLOW 100°F 150°F 38°C 66°C DEC 2016 GFS-310 (Formerly A-1) RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4110 & GL4910 PENDENT RECESSED PENDENT NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. 2AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. 2" MIN. DIA. HOLE IN CEILING 1 29/32" DIA. 2 15/16" DIA. 1" MIN. 1 1/2" MAX. 1/8" 1/8" MIN. 5/8" MAX. 1" x 1/2" REDUCER CUP RETAINER CEILING INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS** CROSS SECTION ORDERING INFORMATION PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com 989-846-4583 1-800-248-0278 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). • Quantity • Model Number • Style • Orifi ce • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 • Quantity - Recessed Wrenches - P/N 325391 • Quantity - Protective Caps - P/N 327109-CAP • (Friction Fit Recessed) 1/2” ADJUSTMENT RECESSED PENDENT SPECIFY NOTE: METRIC CONVERSIONS ARE APPROXIMATE. WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. REFER TO PAGE 2 OF GLOBE’S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 13D AND 13R REQUIREMENTS. FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED. * ** 3 SIN MODEL STYLE TEMPERATURE MAX. AREA OF COVERAGE3 LENGTH x WIDTH Feet (Meters) *MIN. PRESSURE P.S.I. (bars) *MIN. FLOW G.P.M. (L/min.) MIN. DISTANCE BETWEEN SPRINKLERS Feet (Meters) 155°F (68°C) 175°F (79°C) GL4110 PENDENT RECESSED PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) 8 (2.4)X --- 14 (4.3) x 14 (4.3) 8.6 (.59) 12 (45) X X 16 (4.9) x 16 (4.9) 11.7 (.81) 14 (53) GL4910 PENDENT RECESSED PENDENT X X 12 (3.7) x 12 (3.7) 7.0 (.48) 13 (49) 8 (2.4) X X 14 (4.3) x 14 (4.3) 8.2 (.57) 14 (53) X X 16 (4.9) x 16 (4.9) 8.2 (.57) 14 (53) X X 18 (5.5) x 18 (5.5) 12.0 (.83) 17 (64) X X 20 (6.1) x 20 (6.1) 16.7 (1.15) 20 (76) SIN MODEL NOMINAL “K” FACTOR THREAD SIZE LENGTH FINISHES cULus EU NYC - DOB MEA 101-92-E GL4110 GL4910 4.1 (58 metric) 4.9 (68 metric) 1/2”NPT (15mm) 2 1/2” (6.4cm) Factory Bronze Chrome White Polyester2 Black Polyester1,2 X X SPECIFICATIONS AND APPROVALS Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model DH56 HSW Model DH56 HSW Recessed Model DH56 HSW Concealed Quick Response, Extended Coverage Dry Sprinklers B u l l e t i n 0 1 6 R e v . H Bulletin 016 Rev. H For coverages up to 28 feet wide and 10 feet long(1). 250 psi (17,2 bar) rated. Features: 1. Coverage for long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet wide and 10 feet long.(1) 2. Deflector to ceiling dimensions are: 4” (102mm) min. to 12” (305mm) max. 3. Minimum spacing between sprinklers 16 feet (4.9m).(1) 4. Polyester Coated or Electroless Nickel PTFE (Teflon®)* Plated Corrosion Resistant Sprinklers. *Concealed Sprinkler is not corrosion resistance. 5. UL Listed for extended coverage, light hazard applications. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi (17,2 bar) applications. 8. Quick response performance. 9. ½” (13mm) adjustment of escutcheon and cover. 10. Concealed cover plate can prevent the sprinkler from being used for unintended purposes. No exposed thermal element with the concealed version. 11. Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12. Factory assembled sprinkler & cup, shipped complete with bulb protector for concealed and FP recessed versions. 13. Sprinkler & cup assembly and escutcheon or cover are separately packaged. 14. Available in a variety of plated and painted finishes (1) See Fig. 9. Approval Organizations 1. Listed by Underwriters Laboratories Inc. and UL certified for Canada (cULus) 2. NYC MEA 258-93-E Patents US Patent No. 7,841,418 Other Patents Pending Products Description The Model DH56 are quick response extended cover- age sidewall dry sprinklers for use in light hazard applica- tions. The Model DH56 dry sprinkler with SWC cover plate is a concealed sprinkler that uses Reliable’s push on/thread off sidewall cover. This sprinkler has the cup factory mounted and is shipped with a bulb protector that protects the 3mm frangible glass bulb during shipping and post installation fin- ishing operations. The DH56 can be combined in the field with the FP Escutcheon to make a recessed dry sprinkler. DH56 HSW Concealed with SWC coverplate (See Fig. 7) DH56 HSW (See Fig. 4) DH56 HSW FP Recessed (See Fig. 6) DH56 HSW/HB (See Fig. 5) The SWC cover plate and FP recessed escutcheons have ½” adjustment. The SWC cover plate is attached with 135 & 165 degree solder. In the event of a fire the rising ambient temperature melts the solder and the cover plate is ejected away by springs exposing the 3mm frangible glass bulb. The use of a 3mm bulb allows quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the same temperature rating. Model DH56 dry sprinklers are intended for use in dry and preaction systems to protect areas subjected to freez- ing temperatures and unheated portions inside and outside buildings. See Fig. 1 for guidelines on using dry sprinklers in wet systems.*DuPont Registered Trademark 2. Environments wherein dry sprinklers are employed can be corrosive. For this reason, Model DH56 dry sprinklers have a special wax fillet placed in the gap between the cup that supports the bulb and the wrenching boss. This wax will not interfere with the operation of the sprinkler, and it prevents contaminants from entering the internal portion of the drop nipple. The wax must not be removed. Application The Model DH56 is a horizontal sidewall dry sprinkler intended for installation in light hazard occupancies in ac- cordance with NFPA 13. These sprinklers are designed to provide fire protection in long and narrow spaces such as hallways, corridors, decks and rooms up to 28 feet (8,5m) wide and 10 feet (3m) long. They are rated for 250 psi (17,2 bar) and can be mounted between 4 and 12 inches (102 and 305mm) down from the ceiling. General Installation Instructions Model DH56 dry sprinklers must be installed only in stan- dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) pipe tees in the horizontal position, even at branch line ends. They should not be installed into elbows or pipe couplings located on drop nipples to the sprinklers. For these and other fittings including CPVC, the dry sprinkler should be installed into a fitting to allow protrusion into the fitting in ac- cordance with the diagrams. The “A” dimension of the dry sprinkler, which extends into a freezing zone from wet pipe systems, should be selected to provide, as a minimum, the specified lengths in inches shown in Fig. 1. Caution: Do not install Model DH56 HSW Dry sprinklers into CPVC adapter fittings or tees that have an internal obstruction. This will damage the sprinkler and /or the fitting. Refer to Fig. 8 DH56 HSW To install the DH56 HSW dry sprinkler cut a 21/8” diameter hole in the wall as shown in Fig. 4. Use the Model F3 instal- lation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting1. Apply a Teflon* based sealant to the sprinkler threads before install- ing in the sprinkler. Installation is completed by removing the orange glass bulb-protector and assembling the slip-on escutcheon to the sprinkler’s can. DH56 HSW/HB To install the DH56 HSW/HB dry sprinkler cut a 2½” di- ameter hole in the wall as shown in Fig. 5. Use the Model F3 installation wrench (see Fig. 3) on the square boss to tighten the sprinkler until it is secured in the sprinkler fitting1. Apply a Teflon* based sealant to the sprinkler threads be- fore installing in the sprinkler. Installation is completed by removing the orange glass bulb-protector and assembling the slip-on escutcheon to the sprinkler’s can. DH56 HSW Recessed with FP Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutch- eon as a recessed sprinkler cut a 25/8” diameter hole in the wall as shown in Fig. 6. Temporarily remove the plastic pro- tective cap, and then use the Model XLO2 wrench1 (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the push-on escutcheon. Turn clockwise to adjust the escutcheon against the wall. DH56 HSW Concealed with SWC Cover Plate To install the DH56 HSW dry sprinkler with the SWC cover- plate as a concealed sprinkler, cut a 21/8” diameter hole into the wall as shown in Fig. 7. Temporarily remove the plastic protective cap, and then use the Model XLO2 wrench1 (see Fig. 2) to tighten the sprinkler until it is secured in the sprin- kler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon* based seal- ant to the sprinkler threads before installing in the sprinkler. It is recommended that the sprinkler be protected during plastering and painting operations by reinstalling the plastic protective cap. Installation is completed by removing the protective cap and inserting the coverplate. Coverplate as- semblies provide ½” (13mm) of adjustment. Final adjust- ment is made by turning the coverplate clockwise until the skirt flange makes full contact with the wall surface. Cover removal requires turning in the counter-clockwise direction. Concealed coverplate assemblies are listed only for use with specific sprinklers. The use of any other concealed wall sprinkler or the use of the SWC coverplate on any sprinkler with which it is not specifically listed will void all guarantees, warranties, listings and approvals. Note: DH56 and DH56 Recessed Sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SER- VICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDO- ING THE CLASP BY HAND. DO NOT USE TOOLS TO RE- MOVE THE PROTECTORS. *DuPont Registered Trademark 1 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interfaces with the steel outer tube of the assembly (Item #8 on fig 10). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler’s removal at a later date. Fig. 1 3. 4. Step 3 Step 2 Step 1 Fig. 2 - XLO2 Wrench Fig. 3 - F3 Wrench Maintenance Model DH56 Quick Response Dry Sprinklers should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in their original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Model DH56 Quick Response Extended Coverage Horizontal Sidewall Dry Sprinkler Specifi cation Sprinklers shall be a [quick response – cULus Listed] ex- tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction with a special deflector capable of providing a discharge over a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long horizontal throw. Water seal assembly shall consist of a Teflon* coated Belleville spring washer. Installation shall permit sprin- kler deflectors to be positioned 4“ (102mm) to 12” (305mm) below the ceiling. Sprinklers shall have a nominal K-factor of 5.6 (80), and 1” NPT thread. Sprinkler temperature rating shall be [155°F (68° C)] and [200°F (93°C)]. Rated working pressure shall be 250 psi (17.2 bar). Standard finish: [white] [chrome][bronze][Special finish– specify]. Quick response extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For recessed EC horizontal sidewall sprinklers: Replace “horizontal sidewall” with “recessed horizontal sidewall.” Add: (1) Recessed escutcheon assembly shall be a two-piece es- cutcheon of push-on and thread off design with ½” (13mm) adjustment. Standard finish shall be chrome, white and brass. Quick response recessed horizontal sidewall sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace “horizontal sidewall” with “concealed horizontal sidewall.” Add: Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” (13mm) cover plate adjust- ment. Cover plate temperature rating shall be 135°F (57°C) for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [white] [Custom Color– specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664 (Bulletin 016). Technical Data: K Factor Thread Size Temperature Rating Maximum Ambient Temperature Sprinkler Identifi cation Number (SIN)US Metric Sprinkler SWC Cover 5.6 80 1” 155°F (68°C) 135°F (57°C) 100°F (38°C) RA1664 175°F (79°C) 165°F (74°C) 150°F (66°C) 200°F (93°C) 165°F (74°C) 150°F (66°C) Coverage Area Maximum Coverage Area Width x Length ft x ft (m x m) Flow Rate gpm (L/min) Pressure psi (bar) 28 x 8 (8,5 x 2,4) 23 (87,1) 16.9 (1,2) 28 x 10 (8,5 x 3) 28 (106) 25 (1,7) Approval Type: • Quick Response, Extended Coverage. • Approved for installation in accordance with NFPA 13 for light hazard occupancies. *DuPont Registered Trademark 5. Note: The Sprinkler Can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides - ¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 4 Note: The Sprinkler Can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment pro- vides - ½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 5 6. Fig. 7 Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 6 7. Fig. 8 Ordering Information Specify: 1. Sprinkler Type (select one): (a) Model DH56 Dry EC HSW (b) Model DH56 Dry EC HSW/HB (c) Model DH56 Dry Recessed EC HSW/FP (d) Model DH56 Dry Concealed EC HSW 2. Sprinkler Temperature Rating. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. 5. Length: “A” Dimension (face of tee to face of ceiling or wall) in 1/4” (6mm) increments. Notes: 1. The “A” dimension is based on a nominally gauged pipe thread “make-up” of 0.600” (15mm) per ANSI B2.1 [7½ threads approximately]. 2. All platings and paintings are decorative and intended for interior use. UL Listing Category Sprinklers, Automatic and Open. Quick Response Sprinklers. Installation Wrench1 Model XLO2 Sprinkler Wrench (Recessed & Concealed) Model F3 Sprinkler Wrench Note: A leak tight 1” NPT sprinkler joint can be obtained with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Escutcheon Data: FP cup/escutcheon assembly - ½” (13mm) adjustment Finishes (1) Standard Finishes (1) Sprinkler Escutcheon Cover Plate White or Black Polyester (2) ChromeBronze Brass (3) WhiteChrome White Special Application Finishes Sprinkler HSW/HSW HB Escutcheons Electroless Nickel PTFE(Teflon®)*(2)Electroless Nickel PTFE (Teflon®)* (1) Other colors and finishes are available. Consult factory for details. (2) cULus listed Corrosion Resistant (3) Not available for HB escutcheons. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. Fig. 9 1 Installation Wrenches: Throughout this technical bulletin, Reliable has specified specific installation wrenches for use on each version of our sprinklers. A pipe wrench may also be used to install a dry sprinkler provided that it only interferes with the steel outer tube of the assembly (item #8 on fig 16). Keep in mind that a pipe wrench will incorporate a large amount of torque into the final assembly. This torque will have to be matched or exceeded upon the sprinkler removal at a later date. 8. *DuPont Registered Trademark 9. Fig. 10 ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C331400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL TEFLON COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL MATERIAL SPECIFICATIONS Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 02/15 P/N 9999970308 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3QR56 Dry K5.6 (80 metric) Quick-Response, Standard Spray Sprinklers B u l l e t i n 1 5 7 R e v . M Bulletin 157 Rev. M Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended es- cutcheon • Horizontal Sidewall with Model FP recessed es- cutcheon (FM Standard Response) • Horizontal Sidewall with Model F1 recessed es- cutcheon (FM Standard Response) 2. Available with 1” NPT, ISO7-1R1, 3/4” NPT, or ISO7- 1R3/4 inlet fitting. 3. 3/4” NPT inlet fittings permit replacement of older 3/4” inlet dry sprinklers without changing to a larger sprin- kler fitting. 4. Sprinklers, escutcheons, and cover plates are avail- able in a wide variety of standard and special appli- cation finishes. 5. White polyester, black polyester, and Electroless Nickel PTFE (ENT) finish sprinklers are cULus Listed as Corrosion Resistant. 6. Available with cULus Listed 250 psi (17.2 bar) pres- sure rating for Dry Pendent and select HSW configu- rations. FM Approved for 175 psi (12 bar). Product Description Model F3QR56 Dry sprinklers are quick-response, stan- dard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent or Dry Horizontal Sidewall configurations, Model F3QR56 Dry sprinklers all use a 3 mm glass bulb operating element. See the Temperature Rat- ings table in this Bulletin for available temperature ratings. Model F3QR56 Dry sprinklers are intended for installation on wet-pipe, dry-pipe, or preaction sprinkler systems in ac- cordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other applicable installation standards. Model F3QR56 Dry sprinklers are available with a vari- ety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3QR56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Avail- able sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3QR56 Dry sprinklers; the use of any other recessed escutcheon or cover plate with Model F3QR56 Dry sprinklers will void all guarantees, warranties, listings and approvals. Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) Inlet fittings are available with 1” NPT, ISO 7-1R1, 3/4” NPT, or ISO7-1R3/4 threads. Sprinklers with 3/4” NPT and ISO7- 1R3/4 inlet fittings are intended primarily for replacement of existing 3/4” or ISO7-1R3/4 inlet dry sprinklers, but may also be used in new installations. 2. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3QR56 Dry sprinklers. Available Configurations, Listings, and Approvals Sprinkler Model Escutcheon or Cover Plate Available Length (See Figs. 1-9) Listings and Approvals(1) Inlet Threads Sprinkler Identification Number (SIN) F3QR56 Dry Pendent Standard Escutcheon 2” to 36” (50 to 900 mm) cULus, NYC 3/4” NPT or ISO7-1R3/4 R5714 HB Extended Escutcheon 3-1/2” to 36” (90 to 900 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus, FM, NYC 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus(2), NYC(2)3/4” NPT or ISO7-1R3/4 R5734 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon Standard Escutcheon 2” to 48” (50 to 1200 mm)cULus(2), FM(3), NYC(2) 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon 3-1/2” to 48” (90 to 1200 mm) cULus(2), FM(3)(4), NYC(2)FP Recessed Escutcheon (1) For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (3) FM Approved for Light Hazard only. (4) Model F3QR56 Dry Horizontal Sidewall with Model F1 or Model FP recessed escutcheon are FM Approved as Standard Response. Patents Model F3QR56 Dry series sprinklers may be covered by one or more of the following patents: US Patent No. 5,775,431 US Patent No. 5,967,240 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) Technical Data Nominal K-Factor: 5.6 gpm/psi1/2 (80 L/min/bar1/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3QR56 Dry Pendent cULus, NYC --250 psi (17.2 bar) FM --175 psi (12 bar) F3QR56 Dry Horizontal Sidewall cULus, NYC 4” to 6 “250 psi (17.2 bar) 6” to 12”175 psi (12 bar) FM --175 psi (12 bar) Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals(1) Ordinary Orange 135°F (57°C)135°F (57°C)100°F (38°C)cULus, FM, NYCRed155°F (68°C) Intermediate Yellow 175°F (79°C)165°F (74°C)150°F (66°C)cULus, NYC Intermediate Green 200°F (93°C)165°F (74°C)150°F (66°C)cULus, FM, NYC High Blue 286°F (141°C)None 225°F (107°C)cULus, FM(2), NYC 165°F (74°C)150°F (66°C)cULus, NYC (1) For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. Finishes Component Sprinkler Escutcheon(1)Cover Plate Standard Finishes Bronze Brass(3)White Paint White Polyester(2)White Polyester ChromeChromeChrome Special Application Finishes Electroless Nickel PTFE(2) Electroless Nickel PTFE Black Polyester Customer Color Polyester Satin Chrome Black Paint Custom Color Paint Black Plating Black Polyester(2) Custom Color Polyester (1) Standard and Model HB escutcheons are supplied with both the can and escutcheon finished. Model F1 escutcheons are supplied with both the collar and escutcheon finished. Model FP escutcheons are supplied with the escutcheon finished; the cup is galvanized steel with no further finish. (2) cULus Listed as a Corrosion Resistant Sprinkler. (3) Brass finish available for standard, Model F1, and Model FP escutcheons only. 3. 4. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 1 Model F3QR56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5714) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Sprinkler Guard: Model C2 Model F3QR56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5714) “A” Dim.3½” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 2 5. Sprinkler Guard: Model C2 Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model FP escutcheon in ceilings which have positive pressure in the space above. Fig. 3 6. Model F3QR56 Dry Pendent Sprinkler with Model FP Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Model F3QR56 Dry Pendent Sprinkler with Model CCP Cover Plate (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Pendent sprinkler with the Model CCP cover plate in ceilings which have positive pressure in the space above. Fig. 4 7. Model F3QR56 Dry Pendent Sprinkler with Model F1 Recessed Escutcheon (SIN R5714) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections. Fig. 5 8. Note: The sprinkler can protrudes ¼” when escutcheon is in nominal position. Escutcheon adjustment provides -¼” (-6mm) to +1¼” (+32mm) “A” dimension adjustment range. Fig. 6 9. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Standard Escutcheon (SIN R5734) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections 10. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model HB Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 7 11. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: Do not install the Model F3QR56 Dry Horizontal Sidewall sprinkler with the Model FP escutcheon in walls which are positively pressurized with respect to the protected space. Fig. 8 12. Model F3QR56 Dry Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon (SIN R5734) “A” Dim.31/2” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Fig. 9 13. Fig. 10 Fig. 11 14. Fig. 13 - Model XLO2 Wrench Fig. 12 - Model F3 or Model F3R Wrench 15. ITEM # DESCRIPTION MATERIAL SPECIFICATION 1 FRAME BRASS PER UNS C83600 2 DEFLECTOR BRONZE PER UNS C51000 3 LOAD SCREW BRASS PER UNS C22000 4 SEAT ADAPTOR BRASS ALLOY PER UNS C36000 5 BULB INSERT COPPER ALLOY PER UNS C31400 6 GLASS BULB GLASS W/GLYCERIN SOLUTION 7 ORIFICE ADAPTOR BRASS ALLOY PER UNS C36000 8 OUTER TUBE GALVANIZED STEEL 9 INNER TUBE BRASS ALLOY PER UNS C23000 10 YOKE BRASS ALLOY PER UNS C38000 11 INLET BRASS ALLOY PER UNS C35330 12 CAP BRASS ALLOY PER UNS C54400 13 SPRING WASHER/SEAL PTFE COATED BERYLLIUM NICKEL 14 FLIP DISK BRASS ALLOY PER UNS C54400 15 CAN/ESCUTCHEON PAINTED OR PLATED MILD STEEL Fig. 16 16. 17. Installation Instructions Model F3QR56 Dry sprinklers must only be installed in the following fittings: 1. The side outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee 2. The run outlet of an ANSI B 16.3 class 150 (malleable or ductile) or ANSI B16.4 class 125 (cast) iron pipe tee, with the side outlet plugged (wet-pipe systems only) 3. Spears Manufacturing Company Brass Thread In- sert Style or Special Reinforced Plastic Thread Style Listed adapter or tee (wet-pipe systems only) (gasket sealed outlets shall not be used) 4. Any Listed CPVC sprinkler adapter or tee only in ac- cordance with Fig. 11 and upon verification that the CPVC adapter or tee does not interfere with the sprin- kler’s inlet (wet-pipe systems only) (gasket sealed outlets shall not be used) Model F3QR56 Dry sprinklers must not be installed into el- bows, welded outlets, or gasket sealed outlets. Installation of the Model F3QR56 Dry sprinkler is not recommend in cop- per pipe systems, as this may reduce the life expectancy of the sprinkler. In all dry-pipe system installations, the Model F3QR56 Dry sprinkler must be installed with protrusion into the fitting in accordance with Fig. 1 through Fig. 9 in this Bulletin. Do not install Model F3QR56 Dry sprinklers with the standard (long) inlet fitting into CPVC fittings that have an internal obstruc- tion (see Fig. 11); this will damage the sprinkler, the fitting, or both. Model F3QR56 Dry sprinklers are available with a short “PL” inlet fitting for installation on CPVC fittings of wet- pipe sprinkler systems only. Model F3QR56 Dry sprinklers connected to wet-pipe sys- tems must be installed with the Exposed Minimum Barrel Length required by Fig. 10 located in a Heated Area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the es- cutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler’s inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3 and F3R wrenches are designed to be in- serted into the groves in the sprinkler’s wrench boss as shown in Fig. 12. The Model XLO2 wrench is de- signed to fit into the cup and engage the wrench boss as shown in Fig. 13. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent damage to the sprin- kler. The sprinkler is then tightened into the pipe fitting to achieve a leak free connection. The recommended minimum to maximum installation torque is 22 - 30 lb- ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7- 1R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F3QR56 Dry sprinkler may be installed using a pipe wrench. The pipe wrench shall only be permitted to inter- face with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 16). Do NOT wrench any other portion of the sprinkler assembly. A pipe wrench can install the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprin- kler because the installation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 4. Standard and Model HB escutcheons can be in- stalled by slipping the escutcheon over the can until the escutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP es- cutcheon is installed by pressing or threading the es- cutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direc- tion. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cover plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. 5. Remove the orange protective clip when placing the sprinkler system in service. Ordering Information Specify: 1. Sprinkler: [Model F3QR56 Dry Pendent SIN R5714] [Model F3QR56 Dry Horizontal Sidewall SIN R5734] 2. Escutcheon/Cover Plate: [None][Standard escutch- eon][Model HB extended escutcheon][Model F1 recessed escutcheon][Model FP recessed escutch- eon][Model CCP cover plate – pendent only] 3. Inlet Threads: [1” NPT][ISO7-1R1][3/4” NPT][ISO7- 1R3/4] 4. Inlet Fitting: [Long – Standard Inlet Fitting][Short “PL” – Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Rat- ings table 6. Sprinkler Finish: See Finishes Table 7. Escutcheon/Cover Plate Finish: See Finishes Table 8. Length: “A” Dimension (face of tee to face of ceiling or wall) in ¼” (6 mm) increments – See Fig. 1 through Fig. 9 Note: The “A” dimension is based on a nominally gauged pipe thread “make-up” of .600” (15mm) per ANSI B2.1 [approxi- mately 7 ½ threads]. Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 10/16 P/N 9999970175 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years,. Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Required Centerline of Sprinkler Tube/Inlet to Finished Ceiling Vertical Dimension* Installation Wrench F3QR56 Dry Pendent Standard Escutcheon 2-1/8” (54 mm) Not Applicable F3 or F3RHB Extended Escutcheon 2-1/2” (64 mm) F1 Recessed Escutcheon 2-1/4” (57 mm) XLO2FP Recessed Escutcheon 2-1/2” (64 mm)CCP Cover Plate F3QR56 Dry Horizontal Sidewall Standard Escutcheon 2-1/8” (54 mm)4-5/8” to 12-5/8” (118 mm to 321 mm)F3 or F3RHB Extended Escutcheon 2-1/2” (64 mm) F1 Recessed Escutcheon 2-1/4” (57 mm)cULus, NYC 4-5/8” to 6-5/8” (118 mm to 168 mm) XLO2 FP Recessed Escutcheon 2-1/2” (64 mm) F1 Recessed Escutcheon 2-1/4” (57 mm)FM 4-5/8” to 12-5/8” (118 mm to 321 mm)FP Recessed Escutcheon 2-1/2” (64 mm) * Based on 5/8” (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3QR56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sen- sitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by us- ing a soft brush or gently vacuuming. Replace any sprin- kler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or op- erated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 B u l l e t i n 1 7 6 R e v . C Bulletin 176 Rev. C Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed/F2 3. F1 Res 30 Recessed/FP 4. F1 Res 30 CCP Pendent 5. F1 Res 49 Pendent 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP 8. F1 Res 49 CCP Pendent 9. F1 Res 58 Pendent 10. F1 Res 58 Recessed Pendent/F1 11. F1 Res 58 Recessed Pendent/FP 12. F1 Res 58 CCP Pendent 13. F1 Res 44 & 58 HSW 14. F1 Res 44 & 58 HSW Recessed HSW/F2 15. F1 Res 58 HSWX 16. KRes58 HSWX 17. F1 Res 44 SWC 18. F1 Res 76 Pendent 19. F1 Res 76 Recessed Pendent/F1 20. F1 Res 76 Recessed Pendent/FP 21. F1 Res 76 CCP Pendent F1 Res 30, 49, 58 & 76 Recessed Pendent/F1 The 3mm glass-bulb pendent sprinklers permit the ef- ficient use of residential water supplies for sprinkler cover- age in residential fire protection design. Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the water- way for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (Actual) - F1 Res 58 Pendent & HSW/HSWX Sprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.10 gpm/ft2 F1 Res 30, 49, 58 & 76 Recessed Pendent/FP F1 Res 30, 49, 58 & 76 CCP Pendent F1 Res 44 & 58 Recessed HSW/F2Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinkler Patent Pending - Model F1 Res 76 Pendent Sprinkler Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass-bulb and low profile decorative design. F1 Res 44 SWC F1 Res 58 HSWX 2. K=7.6) that will provide lower pressure demands for 0.1 gpm/ft2 densities in NFPA 13 residential applica- tions. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (24/4.9)2 = 24 psi (1.65 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- fore, the minimum flow required is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No. 2 Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) Coverage Area= 8 x 20 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K=7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Example No. 4 Room Size= 14 ft x 18 ft (4.3 m x 5.5 m) Coverage Area= 14 x 18 = 252 ft2 (23.6 m2) Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K=7.6 Pressure= (252/7.6)2 = 11 psi (0.76 bar) The baseline flow and pressure of an 18 ft x 18 ft cover- age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm @ 11 psi (94.6 L/min @ 0.76 bar). In general residential sprinklers require fl ows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the fl ows and pressures at 0.05 density are the baseline fl ows and pressures. Flows and pressures below the listed 0.05 density shall not be used. Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems designed to NFPA 13D or NFPA 13R, use listed area of coverage and minimum flow and pressure requirements shown in Bulletin 135. For systems designed to NFPA 13, use information in this bulletin. The number of design sprinklers shall be the most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressures. NFPA 13 For residential sprinkler systems designed to NFPA 13, a minimum density of 0.1 gpm/ft2 must be provided over the “design area” that includes the four (4) hydraulically most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum required dis- charge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1. The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is re- quired to use the minimum required flow for the next largest coverage area); or 2. A minimum discharge density of 0.1 gpm/ft2 applied over the “design area” consisting of the four most hy- draulically demanding sprinklers for the actual cov- erage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the As = S x L method to de- termine the sprinkler protection area of coverage in accordance with NFPA 13, apply the 0.1 gpm/ft2 den- sity to this area to determine the minimum required flow. Compare this flow to the minimum 0.05 gpm/ft2 cULus Listed flow for the appropriate coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the technical bulletin is less than the calculated 0.1 gpm/ft2 density flow required, the .1 density flow must then be used in the equation Q=KP, solving for P, to establish the mini- mum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual resi- dential sprinklers may exceed the required minimum 0.05 gpm/ft2 density. Reliable has available resi- dential sprinklers with larger K-factors (K=5.8 and 3. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Mod- el F1 Res sprinklers. Use of any other recessed escutch- eon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprin- kler wrench; for installing Model F1 Res recessed HSW sprinklers use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may dam- age these sprinklers. Note: A ‘leak tight” sprinkler joint can be obtained with the following torque: • 3/4” NPT (R3/4) – 14-20 ft-lbs (19 - 27.1 N-m) • ½” NPT (R1/2) – 8-18 ft-lbs (10.8 – 24.4 N-m) Do not tighten sprinklers over maximum recom- mended torque. It may cause leakage or impairment of the sprinklers. F1 escutcheon, 3/4” (19mm) adjustment • Model F1 Res 30, 49, 58 & 76 Pendent • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / F1/F2 Note: See escutcheon table for dimensions. Fig. 1 Fig. 2 **Baseline fl ows and pressures for 0.05 density Defl ector - to - ceiling Maximum 1” (25mm) to 4” (100mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) 4. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C 1/2” NPT (R1/2)7/16” (11)155 175 68 79 175 (12)100 150 38 66 4.9 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4” (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2” (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler *Defl ector - to - ceiling Maximum 4” (100mm) to 8” (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19 (72) 15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7” (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm) °F °C °F °C ½” NPT (R½) ½” (13) 155 175 68 79 175 (12)100 150 38 66 5.8 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Ceiling -to-Defl ector Inch (mm) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) 1-4 (25-100)R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 155 175 68 79 100 38 3.0 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100); ½ recessed using F2 escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3) 14 (4,3) 10 (37,8) 11 (0,76) 10 (37,8) 11 (0,76) For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures 5. Technical Data: F1 Res 76 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C 3/4” NPT (R3/4)17/32 (13.5)155 175 68 79 175 (12)100 150 38 66 7.6 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4 (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1)3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1)3/16 - 11/16 (4.7 - 17.4) *Calculate for a .10 density but in no case go below the baseline flows & pressures *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 x 20 (6.1x6.1) 23 9.2 (0.63) • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP • Model F1 Res 30, 49, 58 & 76 CCP Pendent* Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1” x ¾” reducer. FP push-on/thread-off escutcheon* Not listed for corrosion resistance. 6. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent / FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½)7/16” (11) 155 68 135 57 175 (12) 100 38 4.9 2.25 (57) CCP Options Data: “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1/2 (12.7)15/16 (24) 3/16 (4.7)3/4 (19) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1) 13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) FP Data “A”: FP Position “A” Inch (mm) Max. Recessed 7/16 (11) Min. Recessed 15/16 (24) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for in- stallation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½) ½ (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 135 57 100 38 3.0 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100); ½ (13mm) recessed using FP escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3) 14 (4,3) 11 (37,8) 13.4 (0,92) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. *Calculate for a .10 density but in no case go below the baseline flows & pressures F1 Res 44 & 58 Recessed HSW/F2 • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8 (10)155 175 68 79 175 (12)100 150 38 66 4.4 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 12 (45.4) 7.5 (0.52) R3531 14 x 14 (4.3x4.3) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 18 (68.1) 16.8 (1.16) 18 x 18 (5.5x5.5) 155 (68) 175 (79) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ¾” NPT (R3/4)17/32” (13.5)155 175 68 79 135 57 175 (12) 100 150 38 66 7.6 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 22 8.4 (0.58) 20 x 20 (6.1x6.1) 25 10.8 (0.74) 8. Technical Data: F1 Res 44 SWC Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Cover Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F °C °F °C °F °C ½” NPT (R½)3/8 (10) 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 13 (49.2) 8.7 (0.60) R3531 14 x 14 (4.3x4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 17 (64.3) 15.0 (1.1) 16 x 18 (4.9x5.5) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9x6.1) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 14 (52.9) 10.2 (0.71) 14 x 14 (4.3x4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9x4.9) 18 (68.1) 16.8 (1.16) 16 x 18 (4.9x5.5) 20 (75.6) 20.7 (1.43) • Model F1 Res 44 SWC* Fig. 5 *Calculate for a .10 density but in no case go below the baseline flows & pressures * Not listed for corrosion resistance. 9. Technical Data: F1 Res 58 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F °C °F °C ½” NPT (R½)½ (13)155 175 68 79 175 (12)100 150 38 66 5.8 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 ½ (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 16 (60.6) 7.6 (0.53) R3533 14 x 14 (4.3x4.3) 155 (68) 175 (79) 18 (68.2) 9.7 (0.67) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 29 (109.8) 25 (1.73) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 31 (117.4) 28.6 (1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 10. Technical Data: F1Res 58 HSWX (SIN RA3533) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C °F °C Bulb ½” NPT (R½)1/2” (13) 175 (12) 155 175 68 79 100 150 38 66 5.8 2.45 (62) RA3533 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C) Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) Fig. 6 Technical Data: KRes58 HSWX (RA3593) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C Link ½” NPT (R½)1/2” (13) 175 (12) 100 38 5.8 2.45 (62) RA3593 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F/74°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 29 (109) 25 (1,72) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. 11. Maintenance Model F1 Res 30, 49, F1 Res 58 & F1 Res 76 Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper op- eration or non-operation. Model F1Res 30, 49 & 58 Pendent Sprinkler Specifi cations Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the appli- cable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance list- ing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb con- taining no plastic parts, and having a temperature rat- ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 (Bulletin 135). *DuPont Registered Trademark 12. Model F1 Res 30, 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/F2, Model F1 Res 30, 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s instal- lation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and deflector shall be of bronze frame construction hav- ing a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residen- tial recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installa- tion guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Con- cealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifi cations Sprinklers shall be [cULus Listed] low flow residen- tial horizontal sidewall sprinklers engineered to pro- vide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guide- lines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprin- kler frame and deflector shall be of bronze frame con- struction having a ½” NPT thread. Water seal assem- bly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2” adjustment (Model F2) standard finish should be Bright Chrome and white painted. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nomi- nal K factor of 4.4. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish– specify]. Residential horizontal sidewall sprinklers shall be Reli- able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). *DuPont Registered Trademark Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Re- place “horizontal sidewall sprinkler” with “recessed hori- zontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjust- ment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Resi- dential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow resi- dential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the list- ed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- ed] [White Polyester] [Special finish– specify]. Residen- tial pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residen- tial recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer’s technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Mod- el F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Stan- dard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer’s installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes(1) Standard Finishes Sprinkler F1, F2, FP Escutcheons Bronze Chrome Plated White Polyester Coated(2) Brass Bright Chrome Plated White Painted Special Application Finishes Sprinkler F1,F2,FP Escutcheons Electroless Nickel PTFE(Teflon®)*(2) Bright Brass Black Plated Black Paint Off White Chrome Dull Electroless Nickel PTFE (Teflon®)* Bright Brass Black Plated Black Paint Off White Chrome Dull (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 13. *DuPont Registered Trademark The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03 /14 P/N 9999970322 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection General Description The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13* •1-1/2 Inch (DN40) Male Thread x Female Thread •1-1/2thru6Inch(DN40thruDN150) Groove x Groove *Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition tocheck valves,control valves, and system piping. The Riser Manifoldsmaybeinstalledineitherthe horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises. WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion.Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end-to-end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve. NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non-hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1.Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable Step 2.Connect the drain line, and then close the drain valve. Step 3.Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code. Step 4.Refer to Figure 4 for optional relief valve. Step 5.Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system.Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. Model 513 (13) Riser Manifold 1-1/2 thru 6 Inch (DN40 thru DN150) For NFPA 13 Sprinkler Systems Page 1 of 6 TFP962APRIL, 2006 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Page2of6 TFP962 FIGURE 1 1-1/2 INCH (DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS to the Waterflow Alarm Switches. 6-1/8" (155,6 mm) 12-5/8" (320,7 mm) (131,8 mm) Male x Male NPT 1. Approximate weight, 11.2 lbs. (5,1 kg). Cover Tamper Switches installed internal ULC Listed Manifolds are equipped with2. NOTES: 3/4" (19,1 mm) 1" 5-3/16" NPT 1 Male x Female NPT, Manifolds Groove x Groove 10" (254,0 mm) Manifolds 14-1/4" 11-1/8" (282,6 mm) (362,0 mm) 2 W a t e r f l o w 3 3. CH: Common Hardware 3-1/2" (88,9 mm) QTY. UL/FM Waterflow Alarm Switch: VSR-SF with Paddle, VSR-SF with Paddle and Cover Tamper Switch, ULC/FM DESCRIPTION 1-1/2" Manifold Body, Groove x Groove Male x Female NPT 2 NO. 1 ............... .............. 1..... ....... 1 1 1 N/A 976-519-02 971-096-00 N/A P/N Water Pressure Gauge 300 psi/2000 kPa3 . . 1 2341 Closed) (Normally Drain Valve Inspector's Test & Drain Valve (Normally set to "Drain") TFP962 Page3of6 FIGURE 2 2 thru 6 INCH (DN50 thru DN150) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 9/16 1 (14,3) C Nominal Installation Dimensions in Inches and (mm) 1 4-5/16 (25,4) 4-5/16 (109,5) (109,5) (25,4) 133 Inch 17-3/16 Cover Tamper Switches installed internal to the Waterflow Alarm Switches. ULC Listed Manifolds are equipped with NOTES: CH: Common Hardware2. 1. H C E D 4 Inch (DN80) 6 Inch (DN150) (DN100) A B Drain Valve (Normally Closed) 20-1/2 (436,6) 20-1/2 (520,7) (520,7) (330,2) (330,2) (330,2) 13 13 QTY. 2 INCH (DN50) MANIFOLD DESCRIPTION ULC/FM UL/FM Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, 2" Manifold Body, Groove x Groove 300 psi/2000 kPa Water Pressure Gauge 3 2 NO. 1 1............... .............. ..1 1 .......1 Manifold 2 Inch 2-1/2 Inch (DN50) (DN65) 976-357-01 976-520-01 2341 Size N/A P/N 16-3/4 17-3/16 (425,5) (436,6) A (330,2) (330,2) 13 13 B 3-1/2 18.77-1/86 14-1/4 1-1/4" NPT to "Drain") (Normally set & Drain Valve F Test (422,3) 16-5/8 (469,9) 18-1/2 (362,0) W a t e r f l o w 1 7-9/16 (152,4) (215,9) (192,1) 8-1/2 3 9-1/16 (181,0) 10 (254,0) (230,2) 2 4-1/2 (88,9) 6-5/8 (168,3) (114,3) 2" NPT 2" NPT G 32.7 (8,5) (18,9) 41.6 (14,8) Drain Size 1-1/4" NPT13-3/4 (331,8) 13-1/16 (349,3) (136,5) (146,1) 5-3/8 5-3/4 D 6-3/8 6-7/8 (161,9) (174,6) E 3-1/2 3-1/2 (88,9) (88,9) FG 1" NPT H Weight (6,1) 13.5 16.8 lbs. (kg) (7,6) 2 Waterflow Alarm Switch: 976-520-05 2341 976-357-05 VSC with Paddle, VSC with Paddle and Cover Tamper Switch, ULC/FM UL/FM Water Pressure Gauge 300 psi/2000 kPa3 1.. .............. ............... 1 1 P/N N/A 2341 976-520-04 976-357-04 N/A P/N 1...............UL/FM 300 psi/2000 kPa Water Pressure Gauge Cover Tamper Switch, VSC with Paddle and ULC/FM Groove x Groove 6" Manifold Body, DESCRIPTIONNO. 1 3 ....... 6 INCH (DN150) MANIFOLD QTY. 1 .............. 1.. 1 Groove x Groove 4" Manifold Body, DESCRIPTION Waterflow Alarm Switch: VSC with Paddle, 2 NO. 1 .......1 QTY. 4 INCH (DN100) MANIFOLD 1..............ULC/FM 976-520-02 2341Water Pressure Gauge 300 psi/2000 kPa3 ..1 976-357-02............... Groove x Groove 2-1/2" Manifold Body, Cover Tamper Switch, VSC with Paddle and VSC with Paddle, Waterflow Alarm Switch: DESCRIPTION 2-1/2 INCH (DN65) MANIFOLD 1 UL/FM 2 NO. ....... 1 N/A1 P/NQTY. 1..............ULC/FM 976-520-03 300 psi/2000 kPa Water Pressure Gauge 3 1. . 2341 ............... 3" Manifold Body, Groove x Groove Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, DESCRIPTION 3 INCH (DN80) MANIFOLD 1 2 UL/FM NO. 1 .......1 976-357-03 N/A QTY. P/N Page4of6 TFP962 FIGURE 3 WIRING GUIDANCE INCOMING OUTGOING SINGLE CONDUCTOR TERMINAL PLATE LOOPED SECTION UNINSULATED CLAMPING CONDUCTORS SEPARATE STRIPPED ENDS SWITCH TERMINAL CONNECTIONS CLAMPING TERMINAL PLATE IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD SEVERED CAUTION: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS COM NCNO NO FLOW CONTACTS SPDT (Form C) 5A @ 125 VACCONTACT RATING 2.5A @ 30 VDC .......... .... COM NO NC POWER SIGNAL LOCAL DEVICE NON-SUPERVISED CIRCUITCONDITION END OF LINE RESISTOR COM SUPERVISED CIRCUIT STYLE B/CLASS B CONTROL NO NC PANEL signaling unit, while the other contact is used to operate a local audible or visual annunciator. Switch has two switches, one can be used to operate a central station, proprietary or remove For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm NOTE: (SEE NOTE) COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS SHOWN WITH COVER IN PLACE COM .......... ....CONTACT RATING NO CONTACTS 3A @ 250 VAC 5A @ 125 VAC NC SPDT (Form C) 1mA @ 5 VDC min. Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stallingcontractor orproductmanufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Noattemptistobemadetorepairany Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The alarm/flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise thoseresponsibleformoni- toring proprietary and/or central sta- tion alarms. Alarm/Flow Test Procedure Step 1.Place the test & drain Valve in the “test” position. Step 2.Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3.Verify operation of associated alarms. Step 4.Close the drain valve. Step 5.Place the test & drain Valve in the “drain” position. Step 6.Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7.Close the drain valve. Step 8.Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. TFP962 Page5of6 FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE 1 system outlet piping, and a connection back 3/8" Copper Tubing, 2" (DN50) Manifolds 6" (DN150) Manifolds 4" (DN100) and 3" (DN80) Manifolds To install optional Pressure Relief Trim on must be provided by the installer on the a 1-1/2" (DN40) Manifold, a 1/2" NPT outlet 2-1/2" (DN65) and 1 1 1 .... ... .... 971-124-02 971-124-01 971-124-03 Pressure Relief Valve, DESCRIPTION 175 psi, Nonadjustable NO. 2 QTY. 1. . 198-066-00 P/N CH: Common Hardware with installer supplied 3/8" copper tubing. to the manifold drain trim must be fabricated 3 2 134 2 3 1-1/2" (DN40) Manifold Discard unused trim components. Fabricated 3/8" Copper Tubing Installer 1/2" NPT Outlet 90° Compression Fitting .............. 1" x 1/2" Reducing Hex4 Bushing 1 CH DESCRIPTIONNO. 3 QTY. P/N CH2................Fitting Manifold Drain Trim 3 Provided System Outlet Installer Piping 1-1/2" (DN40) Manifold Only: 2" (DN50), 2-1/2" (DN65), 6" (DN150) Manifold 3" (DN80), 4" (DN100), or Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which havebeensubjecttomisuse,improper installation,corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume forit, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer’s repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,specialorconsequentialdam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, ex- press or implied, including warranties ofmerchantabilityandfitnessforapar- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow alarm switch, P/N (specify). NOTES Orders for Figure 513 may be filled with a Figure 13. The two assemblies are completely interchangeable in function, application, and end-to-end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UL/ULC/FM Assemblies With Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4086 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4087 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4090 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4091 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4092 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4095 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4096 UL/FM Assemblies Without Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4055 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4056 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4060 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4061 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4062 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4065 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4066 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, P/N (specify). 1-1/2" or 2". . . . . . . . . . . . . . . P/N 4063 2-1/2" or 3". . . . . . . . . . . . . . . P/N 4072 4" or 6" . . . . . . . . . . . . . . . . . . P/N 4073 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold,P/N (Ref. Figure 1 or 2, as applicable). Page6of6 TFP962 TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446