FS PRODUCT DATA - 16-00482 - Campus Courtyard 2 Bld 8
510 CPVC - COPPER - HANGER STEEL SIZE - SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION P FASTENERS WOOD STEEL FEATURES #905 ORDERING 3/4 thru 3" - Carbon Steel. - Mil. Galvanized. -S - - in : 3/4" - 3" CPVC pipe - 3/4" - " Steel pipe - 1/4 x11/2 lag - no pre-drill. in 3/4" - 3" CPVC - * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. AFCON " upport horizontal piping: 3/4" -3" CPVC. Support horizontal piping: 3/4"-2" Steel and Copper. Size 3/4" - 2" provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Stabilize vertical piping. including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. screw - no pre-drill. 2 and Copper " " bolt min. 18 GA. pipe 1/4" or #14 Tek Screw. 3/4" - 2" Steel and Copper pipe - 1/4" or #14 Tek Screw. LISTING/APPROVAL- 203 - EX 4231, EX 2551 er these instructions #905 - UL Listed per NFPA13 Hanger Stabilize -Only CANALSO BE USED TO REPLACE - #500 Pipe Strap #520 Tin Strap Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 1/12 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org C 3/4 1 11/4 11/2 2 21/2 3 510 SIZE 2.125 2.312 3.170 3.400 4.010 4.320 5.320 L Fastener Dim. CL- CADCADCAD 514 OFFSET HANGER CPVC - COPPER STEEL• SIZE SYSTEM PIPE: MATERIAL FINISH PATENT No. 6,648,278. FUNCTION INSTALLATION WOOD - #905 STEEL- FEATURES #905 ORDERING 906 - 3/4" thru 3" - Carbon Steel. - Mil. Galvanized.. - -S rovid vertical ateral restraint revents upward movement of pipe that supplies a pendent sprinkler below ceiling. - including NFPA13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. CPVC pipe - screw- no pre-drill. Copper pipe - Steel pipe - 1/4 x1 lag screw - 5/8 gypsum board - 1/4 x lag screw min. * 1 1/2 Offset * 3/4 and 1 pipe size a e common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * screw included - 5/16" hex head. - Part # and pipe size. # backing nut sold separately. AFCON AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 CONCRETE each = upport horizontal piping: 3/4" -3" CPVC or Copper. Support horizontal piping: 3/4" - 2" Steel. Size 3/4" - 2" p es listed /l and p a Stabilize vertical piping. When #905 threads are exposed in wood, install #906 backing nut. - UL Listed per NFPA13 3/4" - 3" 3/4" - 2" screw- no pre-drill. 3/4" - 2" " 1/2" no pre-drill. Thru " " 2" . 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. : Required minimum load fastener " - loose fit allows pipe to slide. " " m d with • 5(wt)+250lbs. 2 1.5000 #905 #906 Listed Restraint Listed Restraint Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 3.00 10/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 3/4 thru 2"" 3/4 thru 2"" CADCADCAD 511 CPVC - COPPER HANGERSIDE MOUNT SIZE SYSTEM PIPE: MATERIAL FINISH FUNCTION INSTALLATION , WOOD #905 STEEL FEATURES #905 ORDERING - 3/4" thru 2" - Carbon Steel. - Mil. Galvanized. - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. - including NFPA13, 13R 13D and CPVC manufacturers instructions. Install on vertical mounting surface. in : CPVC pipe - Copper pipe - screw - no pre-drill. in CPVC pipe - Copper pipe - 1/4 or #14 Tek Screw. * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required screw included - 5/16" hex head. - Part # and pipe size. ” AFCON LISTING/APPROVAL- 203 - EX 4231, EX 2551 Per these instructions FASTENERS #905 - - UL Listed per NFPA13. 3/4" - 2" screw - no pre-drill. 3/4" - 2" min. 18 GA. 3/4" - 2" 1/4 or #14 Tek Screw. 3/4" - 2" ” Side View - For Drawings Below Hanger - Metal Stud Hanger - Wood Stud Specific products are exclusively designed to be compatible with other products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. the following warranty restriction will apply. - will warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by . shall be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non- products have been, or are used. AFCON AFCON AFCON AFCON AFCON AFCON ONLY Be advised DISCLAIMER NOT NOT 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org CADCADCAD BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet Page 1 of 2 APRIL 2016 TFP1915 Worldwide Contacts www.tyco-fire.com General Description TYCO CPVC Pipe and Fittings pro- duced by Tyco Fire Protection Prod- ucts (TFPP) are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermo- plastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch thru 3 Inch Maximum Working Pressure175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved City of Los Angeles (Refer to Installation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. MaterialPipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 ColorOrange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900 dated April 2016. GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP1915 Page 2 of 2 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. BLAZEMASTER is a trademark of The Lubrizol Corporation. Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authority having juris- diction. Contact the installing contrac- tor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com Sizes: Working Pressure: Temperature Range: Orientations: 2⁄” , 3”, 4”, 6”, 8” 10-175psi (0.7-12.1 bar) 33°-140°F (1°-60°C) 40/50(H) 20/30(H,V) The Deringer 20, 30, 40 and 50 backflow prevention valves are designed to prevent non-health/health hazard pollutants from entering the potable water supply system caused by backpressure and/or backsiphonage conditions. Rev. B UL-SPEC-001 Backflow Direct, LLC • 3290 Monier Circle • Rancho Cordova • California • 95742 • United States of America Phone: 916-760-4524 Website: www.backflowdirect.com DEC 2016 GFS-310 (Formerly A-1) RESIDENTIAL AUTOMATIC SPRINKLERS MODELS GL4110 & GL4910 PENDENT RECESSED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4110 and GL4910 Residential Sprinklers have a low profi le yet durable design which utilize a 3mm fran- gible glass ampule as the thermosensitive element. They feature economy, aesthetics and low fl ow. The combination of the 3mm frangible glass ampule and spe- cially designed defl ector make the Model GL4110 and GL4910 Residential Sprinklers the ultimate in life safety and fi re control. These Globe Pendent and Recessed Pendent Residential Sprin- klers have met the strict requirements of Underwriters Laboratories Inc. as described in the UL Standard for Residential Sprinklers for Fire Protection Service, UL 1626, and should be used accordingly. These sprinklers should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direc- tion of the approving authorities having jurisdiction. The heart of Globe's Model GL4110 and GL4910 sprinklers proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fl uid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pres- sure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern. The sprinkler and escutcheon are not factory assembled. Assembly is done in the fi eld. RESIDENTIAL PENDENT RESIDENTIAL RECESSED PENDENT TECHNICAL DATA • See reverse side for Approvals and Specifi cations. • Temperature Rating - 155°F (68°C), 175°F (79°C) • Water Working Pressure Rating - 175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze • Defl ector - brass • Screw - brass • Bulb seat - copper • Spring - nickel alloy • Seal - tefl on • Bulb - glass with alcohol based solution, 3mm size • Escutcheon Assembly - steel SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER TEMPERATURES BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURE ORDINARY INTERMEDIATE 155°F 175°F 68°C 79°C RED YELLOW 100°F 150°F 38°C 66°C DEC 2016 GFS-310 (Formerly A-1) RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4110 & GL4910 PENDENT RECESSED PENDENT NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 1FINISHES AVAILABLE ON SPECIAL ORDER. 2AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. 2" MIN. DIA. HOLE IN CEILING 1 29/32" DIA. 2 15/16" DIA. 1" MIN. 1 1/2" MAX. 1/8" 1/8" MIN. 5/8" MAX. 1" x 1/2" REDUCER CUP RETAINER CEILING INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS** CROSS SECTION ORDERING INFORMATION PRINTED U.S.A. 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 FAX 989-846-9231 www.globesprinkler.com 989-846-4583 1-800-248-0278 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specifi c details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). • Quantity • Model Number • Style • Orifi ce • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 • Quantity - Recessed Wrenches - P/N 325391 • Quantity - Protective Caps - P/N 327109-CAP • (Friction Fit Recessed) 1/2” ADJUSTMENT RECESSED PENDENT SPECIFY NOTE: METRIC CONVERSIONS ARE APPROXIMATE. WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. REFER TO PAGE 2 OF GLOBE’S RESIDENTIAL SPRINKLER INSTALLATION GUIDE (BULLETIN R.S.I.G.) FOR NFPA 13D AND 13R REQUIREMENTS. FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM REQUIRED FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIA ARE STATED. * ** 3 SIN MODEL STYLE TEMPERATURE MAX. AREA OF COVERAGE3 LENGTH x WIDTH Feet (Meters) *MIN. PRESSURE P.S.I. (bars) *MIN. FLOW G.P.M. (L/min.) MIN. DISTANCE BETWEEN SPRINKLERS Feet (Meters) 155°F (68°C) 175°F (79°C) GL4110 PENDENT RECESSED PENDENT X X 12 (3.7) x 12 (3.7) 7.2 (.50) 11 (42) 8 (2.4)X --- 14 (4.3) x 14 (4.3) 8.6 (.59) 12 (45) X X 16 (4.9) x 16 (4.9) 11.7 (.81) 14 (53) GL4910 PENDENT RECESSED PENDENT X X 12 (3.7) x 12 (3.7) 7.0 (.48) 13 (49) 8 (2.4) X X 14 (4.3) x 14 (4.3) 8.2 (.57) 14 (53) X X 16 (4.9) x 16 (4.9) 8.2 (.57) 14 (53) X X 18 (5.5) x 18 (5.5) 12.0 (.83) 17 (64) X X 20 (6.1) x 20 (6.1) 16.7 (1.15) 20 (76) SIN MODEL NOMINAL “K” FACTOR THREAD SIZE LENGTH FINISHES cULus EU NYC - DOB MEA 101-92-E GL4110 GL4910 4.1 (58 metric) 4.9 (68 metric) 1/2”NPT (15mm) 2 1/2” (6.4cm) Factory Bronze Chrome White Polyester2 Black Polyester1,2 X X SPECIFICATIONS AND APPROVALS The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 B u l l e t i n 1 7 6 R e v . C Bulletin 176 Rev. C Model F1 Residential Sprinklers for Design Density of .10 gpm/ft2 Model F1 Res Sprinklers Listed to meet the minimum design density as required by UL1626. Types: 1. F1 Res 30 Pendent 2. F1 Res 30 Recessed/F2 3. F1 Res 30 Recessed/FP 4. F1 Res 30 CCP Pendent 5. F1 Res 49 Pendent 6. F1 Res 49 Recessed Pendent/F1 7. F1 Res 49 Recessed Pendent/FP 8. F1 Res 49 CCP Pendent 9. F1 Res 58 Pendent 10. F1 Res 58 Recessed Pendent/F1 11. F1 Res 58 Recessed Pendent/FP 12. F1 Res 58 CCP Pendent 13. F1 Res 44 & 58 HSW 14. F1 Res 44 & 58 HSW Recessed HSW/F2 15. F1 Res 58 HSWX 16. KRes58 HSWX 17. F1 Res 44 SWC 18. F1 Res 76 Pendent 19. F1 Res 76 Recessed Pendent/F1 20. F1 Res 76 Recessed Pendent/FP 21. F1 Res 76 CCP Pendent F1 Res 30, 49, 58 & 76 Recessed Pendent/F1 The 3mm glass-bulb pendent sprinklers permit the ef- ficient use of residential water supplies for sprinkler cover- age in residential fire protection design. Upon fire conditions, rising heat causes a sprinkler’s heat-sensitive glass-bulb to shatter, releasing the water- way for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: • Thermal Sensor: Nominal 3mm glass-bulb • Sprinkler Frame : Brass Casting • Sprinklers’ Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi • Thread Size: ½” NPT (R1/2) • K-Factor: 3.0 (Actual) - F1 Res 30 Pendent Sprinkler 4.9 (Actual) - F1 Res 49 Pendent Sprinkler 5.8 (Actual) - F1 Res 58 Pendent & HSW/HSWX Sprinkler 7.6 (Actual) - F1 Res 76 Pendent Sprinkler 4.4 (Actual) - F1 Res 44 HSW Sprinkler • Density: Minimum 0.10 gpm/ft2 F1 Res 30, 49, 58 & 76 Recessed Pendent/FP F1 Res 30, 49, 58 & 76 CCP Pendent F1 Res 44 & 58 Recessed HSW/F2Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) 2. NYC MEA 258-93-E UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model F1 Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model F1 Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model F1 Res 44 SWC Sprinkler Patent Pending - Model F1 Res 76 Pendent Sprinkler Product Description Model F1Res Pendent sprinklers (Figs. 1, 2, 3 & 4) combine excellent durability, high sensitivity glass-bulb and low profile decorative design. F1 Res 44 SWC F1 Res 58 HSWX 2. K=7.6) that will provide lower pressure demands for 0.1 gpm/ft2 densities in NFPA 13 residential applica- tions. Example No. 1 Room Size= 12 ft x 20 ft (3.6 m x 6.1 m) Coverage Area= 12 x 20 = 240 ft2 (22.3 m2) Flow @ 0.10 gpm/ft2 density= 240 x 0.10 = 24 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (24/4.9)2 = 24 psi (1.65 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). There- fore, the minimum flow required is 24 gpm @ 24 psi (90.8 L/min @ 1.65 bar). Example No. 2 Room Size= 8 ft x 20 ft (2.4 m x 6.1 m) Coverage Area= 8 x 20 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 49 Pendent Sprinkler, K=4.9 Pressure= (16/4.9)2 = 10.7 psi (0.74 bar) The baseline flow for a 20 ft x 20 ft (6.1 m x 6.1 m) cover- age area using the baseline density of 0.05 gpm/ft2 will be 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Therefore, the minimum flow required is 20 gpm @ 16.7 psi (75.7 L/min @ 1.14 bar). Example No. 3 Room Size= 10 ft x 16 ft (3.0 m x 4.91 m) Coverage Area= 10 x 16 = 160 ft2 (14.9 m2) Flow @ 0.10 gpm/ft2 density= 160 x 0.10 = 16 gpm Using an F1 Res 76 Pendent Sprinkler, K=7.6 The baseline flow for a 16 ft x 16 ft coverage area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Example No. 4 Room Size= 14 ft x 18 ft (4.3 m x 5.5 m) Coverage Area= 14 x 18 = 252 ft2 (23.6 m2) Flow @ 0.10 gpm/ft2 density= 252 x 0.10 = 25.2 gpm (94.6 L/min) Using an F1 Res 76 Pendent Sprinkler, K=7.6 Pressure= (252/7.6)2 = 11 psi (0.76 bar) The baseline flow and pressure of an 18 ft x 18 ft cover- age area is 21 gpm @ 7.6 psi (79.5 L/min @ 0.52 bar). Therefore, the minimum flow and pressure is 25.2 gpm @ 11 psi (94.6 L/min @ 0.76 bar). In general residential sprinklers require fl ows and pressures as listed for 0.05 densities to achieve the proper spray pattern so the fl ows and pressures at 0.05 density are the baseline fl ows and pressures. Flows and pressures below the listed 0.05 density shall not be used. Application Model F1 Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The National Fire Protection Association or the approving authority having jurisdiction. When using F1 Residential Sprinklers for systems designed to NFPA 13D or NFPA 13R, use listed area of coverage and minimum flow and pressure requirements shown in Bulletin 135. For systems designed to NFPA 13, use information in this bulletin. The number of design sprinklers shall be the most hydraulically demanding sprinklers as required by NFPA 13. Flows and pressures can not be below the baseline flows and pressures. NFPA 13 For residential sprinkler systems designed to NFPA 13, a minimum density of 0.1 gpm/ft2 must be provided over the “design area” that includes the four (4) hydraulically most demanding sprinklers for the actual coverage areas being protected by the 4 sprinklers. The minimum required dis- charge from each of the four most hydraulically demanding sprinklers shall be the greater of the following: 1. The flow rates given in the Reliable Residential Sprinkler Technical Bulletins referenced in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area (for actual coverage areas less than or between those indicated in the respective technical bulletin, it is re- quired to use the minimum required flow for the next largest coverage area); or 2. A minimum discharge density of 0.1 gpm/ft2 applied over the “design area” consisting of the four most hy- draulically demanding sprinklers for the actual cov- erage areas being protected by the four sprinklers. The maximum dimension of the actual coverage area cannot be any greater than the maximum coverage area indicated in the technical bulletins referenced in Table A. Design Note: Using the As = S x L method to de- termine the sprinkler protection area of coverage in accordance with NFPA 13, apply the 0.1 gpm/ft2 den- sity to this area to determine the minimum required flow. Compare this flow to the minimum 0.05 gpm/ft2 cULus Listed flow for the appropriate coverage area in the technical bulletin for the specific residential sprinkler. If the flow stated in the technical bulletin is less than the calculated 0.1 gpm/ft2 density flow required, the .1 density flow must then be used in the equation Q=KP, solving for P, to establish the mini- mum required pressure using the sprinkler K-factor. Note: In many cases the listed flow of individual resi- dential sprinklers may exceed the required minimum 0.05 gpm/ft2 density. Reliable has available resi- dential sprinklers with larger K-factors (K=5.8 and 3. Installation Models F1 Res sprinklers are to be installed as shown. Model F1, F2 and FP Escutcheons, illustrated herewith, are the only recessed escutcheons to be used with Mod- el F1 Res sprinklers. Use of any other recessed escutch- eon will void all approvals and warranties. For installing Model F1 Res Pendent sprinklers use only the Model D sprinkler Wrench; for installing Models F1 Res Recessed Pendent, CCP sprinklers use only the Model GFR2 sprin- kler wrench; for installing Model F1 Res recessed HSW sprinklers use only the Model GFR2 Sprinkler wrench. Use of wrenches other than those specified may dam- age these sprinklers. Note: A ‘leak tight” sprinkler joint can be obtained with the following torque: • 3/4” NPT (R3/4) – 14-20 ft-lbs (19 - 27.1 N-m) • ½” NPT (R1/2) – 8-18 ft-lbs (10.8 – 24.4 N-m) Do not tighten sprinklers over maximum recom- mended torque. It may cause leakage or impairment of the sprinklers. F1 escutcheon, 3/4” (19mm) adjustment • Model F1 Res 30, 49, 58 & 76 Pendent • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / F1/F2 Note: See escutcheon table for dimensions. Fig. 1 Fig. 2 **Baseline fl ows and pressures for 0.05 density Defl ector - to - ceiling Maximum 1” (25mm) to 4” (100mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5x5.5) 17 (64.3) 12.0 (0.83) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) 4. Technical Data: F1 Res 49 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C 1/2” NPT (R1/2)7/16” (11)155 175 68 79 175 (12)100 150 38 66 4.9 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4” (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1) 3/16 - 15/16 (4.7 - 24.0) F2 1/2” (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1) 3/16 - 11/16 (4.7 - 17.4) * Note: Escutcheons F1 or F2 may be used with Model F1 Res 49 & 58 Recessed Pendent Sprinkler *Defl ector - to - ceiling Maximum 4” (100mm) to 8” (203mm) Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 15 (57) 9.4 (0.65) R3516 14 x 14 (4.3x4.3) 16 (60.5) 10.6 (0.73) 16 x 16 (4.9x4.9) 17 (64.3) 12.0 (0.83) 18 x 18 (5.5x5.5) 19 (72) 15.0 (1.0) 20 x 20 (6.1x6.1) 22 (83.2) 20.2 (1.4) *Note: The F1 Res 49 pendent and recessed pendent residential sprinklers can be installed per NFPA 13 in beamed ceilings meeting the following criteria: 1. Maximum beam depth = 7” (178mm) 2. Beam spacing at or greater than 7.5 ft. (2.3m) on center. Technical Data: F1 Res 58 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm) °F °C °F °C ½” NPT (R½) ½” (13) 155 175 68 79 175 (12)100 150 38 66 5.8 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Ceiling -to-Defl ector Inch (mm) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) 1-4 (25-100)R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) **Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 Pendent and Recessed Pendent (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. Actual K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 155 175 68 79 100 38 3.0 2.25 (57) **Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100); ½ recessed using F2 escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3) 14 (4,3) 10 (37,8) 11 (0,76) 10 (37,8) 11 (0,76) For Ceiling types refer to NFPA 13, 13R or 13D **Calculate for a .10 density but in no case go below the baseline flows & pressures 5. Technical Data: F1 Res 76 Pendent and Recessed Pendent Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C 3/4” NPT (R3/4)17/32 (13.5)155 175 68 79 175 (12)100 150 38 66 7.6 2.25 (57) Escutcheon*, F1 or F2, Data: Type Adjustment Inch (mm) “A” Inch (mm) Face of fi tting to ceiling Inch (mm) F1 3/4 (19.0)Min.= 3/4 (19.1) Max.=11/2 (38.1)3/16 - 15/16 (4.7 - 24.0) F2 1/2 (12.7)Min.= 15/16 (23.8) Max.=11/2 (38.1)3/16 - 11/16 (4.7 - 17.4) *Calculate for a .10 density but in no case go below the baseline flows & pressures *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 21 7.6 (0.53) 20 x 20 (6.1x6.1) 23 9.2 (0.63) • Model F1 Res 30, 49, 58 & 76 Recessed Pendent / FP • Model F1 Res 30, 49, 58 & 76 CCP Pendent* Fig. 3 Fig. 4 NOTE: The F1 Res 76 will use a 1” x ¾” reducer. FP push-on/thread-off escutcheon* Not listed for corrosion resistance. 6. Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent / FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½)7/16” (11) 155 68 135 57 175 (12) 100 38 4.9 2.25 (57) CCP Options Data: “A” Cover Adjustment Inch (mm) “B” CCP Height Inch (mm) 1/2 (12.7)15/16 (24) 3/16 (4.7)3/4 (19) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 13 (49) 7.0 (0.48) R3516 14 x 14 (4.3x4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9x4.9) 14 (53) 8.2 (0.56) 18 x 18 (5.5x5.5) 18 (68.1) 13.5 (0.93) 20 x 20 (6.1x6.1) 20 (75.7) 16.7 (1.14) FP Data “A”: FP Position “A” Inch (mm) Max. Recessed 7/16 (11) Min. Recessed 15/16 (24) Note: Sprinklers shown in Fig. 3 and Fig. 4 are not suitable for in- stallation in ceilings which have positive pressure in the space above. Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ½” NPT (R½) ½ (13) 155 68 135 57 175 (12) 100 38 5.8 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 16 (61) 7.6 (0.53) R3513 14 x 14 (4.3x4.3) 16 (61) 7.6 (0.53) 16 x 16 (4.9x4.9) 16 (61) 7.6 (0.53) 18 x 18 (5.5x5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1x6.1) 22 (83.3) 14.4 (1.0) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) CCP Assembly Temp. Rating Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)21/64” (8.2) 175 (12) 135 57 100 38 3.0 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12 (3,6) 8 (30,3) 7.0 (0,48) 1 to 4 (25 to 100); ½ (13mm) recessed using FP escutcheon 8 (2,4) 14 x 14 (4,3 x 4,3) 14 (4,3) 11 (37,8) 13.4 (0,92) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a .10 density but in no case go below the baseline flows & pressures 7. *Calculate for a .10 density but in no case go below the baseline flows & pressures F1 Res 44 & 58 Recessed HSW/F2 • Model F1 Res 44 & 58 HSW • Model F1 Res 44 & 58 Recessed HSW/F2 Technical Data: F1 Res 44 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm)°F °C °F °C ½” NPT (R½)3/8 (10)155 175 68 79 175 (12)100 150 38 66 4.4 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 1/2 (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 12 (45.4) 7.5 (0.52) R3531 14 x 14 (4.3x4.3) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 18 (68.1) 16.8 (1.16) 18 x 18 (5.5x5.5) 155 (68) 175 (79) 19 (72.0) 18.7 (1.29) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 14 (53.0) 10.2 (0.71) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 16 (60.6) 13.3 (0.92) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 17 (64.4) 15.0 (1.04) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 20 (75.7) 20.7 (1.43) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 23 (87.1) 27.4 (1.89) *Calculate for a .10 density but in no case go below the baseline flows & pressures Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating CCP Assembly Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp.K Factor Sprinkler Length Inch (mm)°F °C °F °C °F °C ¾” NPT (R3/4)17/32” (13.5)155 175 68 79 135 57 175 (12) 100 150 38 66 7.6 2.25 (57) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 21 7.6 (0.53) R7618 14 x 14 (4.3x4.3) 21 7.6 (0.53) 16 x 16 (4.9x4.9) 21 7.6 (0.53) 18 x 18 (5.5x5.5) 22 8.4 (0.58) 20 x 20 (6.1x6.1) 25 10.8 (0.74) 8. Technical Data: F1 Res 44 SWC Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Cover Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F °C °F °C °F °C ½” NPT (R½)3/8 (10) 155 68 135 57 175 (12) 100 38 4.4 2.45 (62) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 13 (49.2) 8.7 (0.60) R3531 14 x 14 (4.3x4.3) 14 (53.0) 10.2 (0.71) 16 x 16 (4.9x4.9) 17 (64.3) 15.0 (1.1) 16 x 18 (4.9x5.5) 19 (71.8) 18.7 (1.13) 16 x 20 (4.9x6.1) 23 (87.1) 27.4 (1.89) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 14 (52.9) 10.2 (0.71) 14 x 14 (4.3x4.3) 15 (56.7) 11.7 (0.81) 16 x 16 (4.9x4.9) 18 (68.1) 16.8 (1.16) 16 x 18 (4.9x5.5) 20 (75.6) 20.7 (1.43) • Model F1 Res 44 SWC* Fig. 5 *Calculate for a .10 density but in no case go below the baseline flows & pressures * Not listed for corrosion resistance. 9. Technical Data: F1 Res 58 HSW & HSW/F2 Thread Size Nominal Orifi ce Inch (mm) Sprinkler Temp. Rating Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) °F °C °F °C ½” NPT (R½)½ (13)155 175 68 79 175 (12)100 150 38 66 5.8 2.45 (62) Escutcheon, F2, Data: Type Adjustment Inch (mm) Face of Fitting to wall Inch (mm) F2 ½ (13) 3/16 - 11/16 (4.7 - 17.4) *Baseline fl ows and pressures for 0.05 density Max. Sprinkler Spacing ft (m) “A” Ceiling -to- Defl ector Inch (mm) Sprinkler Temp. Rating °F (°C) Flow gpm (Lpm) Pressure psi (bar) Sprinkler Identifi cation Number (SIN) 12 x 12 (3.6x3.6) 4 - 6 (101-152) 155 (68) 175 (79) 16 (60.6) 7.6 (0.53) R3533 14 x 14 (4.3x4.3) 155 (68) 175 (79) 18 (68.2) 9.7 (0.67) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 21 (79.5) 13.2 (0.91) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 25 (94.7) 18.6 (1.28) 16 x 20 (4.9x6.1) 155 (68) 175 (79) 29 (109.8) 25 (1.73) 12 x 12 (3.6x3.6) 6 - 12 (152-305) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 14 x 14 (4.3x4.3) 155 (68) 175 (79) 22 (83.3) 14.4 (1.0) 16 x 16 (4.9x4.9) 155 (68) 175 (79) 26 (98.4) 20.1 (1.39) 16 x 18 (4.9x5.5) 155 (68) 175 (79) 31 (117.4) 28.6 (1.97) *Calculate for a .10 density but in no case go below the baseline flows & pressure 10. Technical Data: F1Res 58 HSWX (SIN RA3533) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Sprinkler Temp. Rating Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C °F °C Bulb ½” NPT (R½)1/2” (13) 175 (12) 155 175 68 79 100 150 38 66 5.8 2.45 (62) RA3533 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F/68°C) Intermediate Temp. Rating (175°F/79°C) Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. • Model F1 Res 58 HSWX (Bulb) • Model KRes58 HSWX (Link) Fig. 6 Technical Data: KRes58 HSWX (RA3593) Thread Size Nominal Orifi ce Inch (mm) Max. Pressure psi (bar) Max. Ambient Temp. K Factor Sprinkler Length Inch (mm) Sprinkler Identifi cation Number (SIN)°F °C Link ½” NPT (R½)1/2” (13) 175 (12) 100 38 5.8 2.45 (62) RA3593 *Baseline fl ows and pressures for 0.05 density Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165°F/74°C)Top of Defl ector to Ceiling Inch (mm) Minimum Spacing Ft (m)Flow GPM (L/min) Pressure PSI (bar) 18 x 20 (5,5 x 6,1) 18 (5,5) 29 (109) 25 (1,72) 4 to 6 (100 to 152); ½ (13) recessed using F2 escutcheon 8 (2,4) 20 x 20 (6,1 x 6,1) 20 (6,1) 30 (114) 26.8 (1,85) 16 x 22 (4,9 x 7,3) 16 (4,9) 33 (125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16 (4,9) 38 (144) 42.9 (2,96) 14 x 26 (4,3 x 7,9) 14 (4,3) 42 (160) 52.4 (3,75) 18 x 20 (5,5 x 6,1) 18 (5,5) 35 (133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) Recessed using F2 escutcheon 16 x 22 (4,9 x 6,7) 16 (4,9) 38 (144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16 (4,9) 42 (160) 52.4 (3,6) 14 x 26 (4,3 x 7,9) 14 (4,3) 46 (174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D *Calculate for a 0.10 density but in no case go below the baseline floor and pressures. 11. Maintenance Model F1 Res 30, 49, F1 Res 58 & F1 Res 76 Sprin- klers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprin- klers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper op- eration or non-operation. Model F1Res 30, 49 & 58 Pendent Sprinkler Specifi cations Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pen- dent sprinklers engineered to provide a minimum de- sign density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the appli- cable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance list- ing shall be 1” to 8” maximum. Sprinkler frame and de- flector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb con- taining no plastic parts, and having a temperature rat- ing of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Residential pendent sprinklers shall be Reliable Model F1 Res 49 & 58, SIN R3516 & R3513 (Bulletin 135). *DuPont Registered Trademark 12. Model F1 Res 30, 49 & 58 Recessed Pendent/F1, Model F1 Res 30, 49 & 58 Recessed Pendent/F2, Model F1 Res 30, 49 & 58 Recessed Pendent/FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s instal- lation guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Deflector-to-ceiling distance listing shall be 1” to 8” maximum. Sprinkler frame and deflector shall be of bronze frame construction hav- ing a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 4.9 (70). Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Model F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residen- tial recessed pendent sprinklers shall be Reliable [Model F1 Res 49 & 58 Recessed Pendent/F1] [Model F1 Res 49 & 58 Recessed Pendent/F2] [Model F1 Res 49 & 58 Recessed Pendent/FP] SIN R3516 & R3513 (Bulletin 135). Model F1 Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer’s installa- tion guidelines and the applicable installation standard. Where pendent residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprinkler frame and deflector shall be of bronze frame construction having a ½” NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb contain- ing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange. Meth- od of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate temperature rating shall be 135°F (57°C). A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Con- cealed pendent sprinklers shall be Reliable Model F1 Res 49 & 58 CCP, SIN R3516 & R3513 (Bulletin 135). Model F1 Res 44, F1 Res 58 Horizontal Sidewall, F1 Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifi cations Sprinklers shall be [cULus Listed] low flow residen- tial horizontal sidewall sprinklers engineered to pro- vide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in con- formance with the manufacturer’s installation guide- lines and the applicable installation standard. Where horizontal sidewall residential sprinklers are installed under sloped ceilings having a pitch from [4/12] to [8/12], the sprinklers shall be listed for such use. Sprin- kler frame and deflector shall be of bronze frame con- struction having a ½” NPT thread. Water seal assem- bly shall consist of a Teflon-coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2” adjustment (Model F2) standard finish should be Bright Chrome and white painted. The F1 Res 58 HSW is also available with low lead frame. F1 Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and F1 Res 44 a nomi- nal K factor of 4.4. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish– specify]. Residential horizontal sidewall sprinklers shall be Reli- able Model F1 Res 44, F1 Res 58, F1 Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). *DuPont Registered Trademark Model F1 Res 44 & 58 Recessed Horizontal Sidewall Sprinkler Use description for the Model F1 Res 58 horizontal sidewall sprinkler with the following modifications: Re- place “horizontal sidewall sprinkler” with “recessed hori- zontal sprinkler.” Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½” adjust- ment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish– specify]. Resi- dential recessed horizontal sidewall sprinklers shall be Reliable Model F1 Res 58/F2, SIN R3513 (Bulletin 135). Model F1 Res 76 Pendent Sprinklers shall be [cULus Listed] low flow resi- dential pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the list- ed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plat- ed] [White Polyester] [Special finish– specify]. Residen- tial pendent sprinklers shall be Reliable Model F1 Res 76, SIN R7618 (Bulletin 135). Model F1 Res 76 Recessed Pendent/F1, Model F1 Res 76 Recessed Pendent/F2, Model F1 Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residen- tial recessed pendent sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer’s technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer’s installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish– specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with ½” adjustment (Mod- el F2)] [with ¾” adjustment (Model F1)] [of push-on and thread off design with ½” adjustment (Model FP)]. Stan- dard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model F1 Res 76 Recessed Pendent/F1] [Model F1 Res 76 Recessed Pendent/F2] [Model F1 Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model F1 Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.10 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer’s technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer’s installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a ¾” NPT thread. Water seal assembly shall consist of a Teflon-coated Belleville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½” cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color– specify]. ]. Concealed pendent sprinklers shall be Reliable Model F1 Res 76 CCP, SIN R7618 (Bulletin 135). Finishes(1) Standard Finishes Sprinkler F1, F2, FP Escutcheons Bronze Chrome Plated White Polyester Coated(2) Brass Bright Chrome Plated White Painted Special Application Finishes Sprinkler F1,F2,FP Escutcheons Electroless Nickel PTFE(Teflon®)*(2) Bright Brass Black Plated Black Paint Off White Chrome Dull Electroless Nickel PTFE (Teflon®)* Bright Brass Black Plated Black Paint Off White Chrome Dull (1) Other finishes and colors are available on special order. Consult factory for details. (2) cULus listed Corrosion Resistant. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Temperature Rating 4. Sprinkler Finish 5. Escutcheon Finish 13. *DuPont Registered Trademark The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03 /14 P/N 9999970322 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gauges • Identification signs • Fire department connection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Reliable...For Complete Protection General Description The Figure 513 (13) Riser Manifolds described in this technical data sheet provide the necessary waterflow alarm, pressure gauge, alarm test ori- fice, drain, and sight glass equipment in a single assembly for use in NFPA 13 sprinkler systems as follows: NFPA 13* •1-1/2 Inch (DN40) Male Thread x Female Thread •1-1/2thru6Inch(DN40thruDN150) Groove x Groove *Although the Riser Manifold described in this data sheet is intended for NFPA 13 sprinkler systems, it may be used for NFPA 13D or 13R residential sprinkler systems, where a test orifice of 5.6K (80K) is accept- able. The variety of sizes and grooved end connections allow cost effective and easy transition tocheck valves,control valves, and system piping. The Riser Manifoldsmaybeinstalledineitherthe horizontal (flow switch on top) or verti- cal (flow going up) for both single sprinkler rises and floor control in high rises. WARNING The Riser Manifolds described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation, in addition to the standards of any other authorities having jurisdic- tion.Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals The Figure 513 (13) Riser Manifolds with a cover tamper switch for the wa- terflow alarm switch are UL Listed, ULC Listed, and FM Approved. The Figure 513 (13) Riser Manifolds without a cover tamper switch for the waterflow alarm switch are UL Listed and FM Approved. Maximum Working Pressure 175 psi (12,1 bar) Test Orifice 5.6K (80K) Assembly The manifold body of the Figure 513 is ductile iron, whereas the manifold body of the Figure 13 is cast iron. The two assemblies are completely inter- changeable in function, application, and end-to-end laying length. Finish Red painted. Installation The Riser Manifolds may be installed in either the horizontal (flow switch on top) or vertical (flow going up). The inlet of the Riser Manifold may be di- rectly connected to a shut-off control valve. NOTES Where applicable pipe thread sealant is to be applied sparingly. Use of a non-hardening pipe thread sealant is recommended. Never remove any piping component nor correct or modify any piping defi- ciencies without first depressurizing and draining the system. Step 1.Install the manifold body with the flow arrow pointing in the down- stream position using threaded con- nections and/or listed mechanical grooved connections, as applicable Step 2.Connect the drain line, and then close the drain valve. Step 3.Refer to Figure 3 for wiring guidance. All wiring must be per- formed in accordance with the Author- ity Having Jurisdiction and/or the Na- tional Electrical Code. Step 4.Refer to Figure 4 for optional relief valve. Step 5.Place the system in service by filling the system with water. When fill- ing the system, partially open the con- trol valve to slowly fill the system.Fill- ing the system slowly will help avoid damaging the waterflow alarm switch. After the system is fully pressurized, completely open the control valve. Step 6.Secure all supply valves open. Model 513 (13) Riser Manifold 1-1/2 thru 6 Inch (DN40 thru DN150) For NFPA 13 Sprinkler Systems Page 1 of 6 TFP962APRIL, 2006 Technical Services:Tel: (800) 381-9312 / Fax: (800) 791-5500 Page2of6 TFP962 FIGURE 1 1-1/2 INCH (DN40) RISER MANIFOLD ASSEMBLY AND DIMENSIONS to the Waterflow Alarm Switches. 6-1/8" (155,6 mm) 12-5/8" (320,7 mm) (131,8 mm) Male x Male NPT 1. Approximate weight, 11.2 lbs. (5,1 kg). Cover Tamper Switches installed internal ULC Listed Manifolds are equipped with2. NOTES: 3/4" (19,1 mm) 1" 5-3/16" NPT 1 Male x Female NPT, Manifolds Groove x Groove 10" (254,0 mm) Manifolds 14-1/4" 11-1/8" (282,6 mm) (362,0 mm) 2 W a t e r f l o w 3 3. CH: Common Hardware 3-1/2" (88,9 mm) QTY. UL/FM Waterflow Alarm Switch: VSR-SF with Paddle, VSR-SF with Paddle and Cover Tamper Switch, ULC/FM DESCRIPTION 1-1/2" Manifold Body, Groove x Groove Male x Female NPT 2 NO. 1 ............... .............. 1..... ....... 1 1 1 N/A 976-519-02 971-096-00 N/A P/N Water Pressure Gauge 300 psi/2000 kPa3 . . 1 2341 Closed) (Normally Drain Valve Inspector's Test & Drain Valve (Normally set to "Drain") TFP962 Page3of6 FIGURE 2 2 thru 6 INCH (DN50 thru DN150) RISER MANIFOLD ASSEMBLY AND DIMENSIONS 9/16 1 (14,3) C Nominal Installation Dimensions in Inches and (mm) 1 4-5/16 (25,4) 4-5/16 (109,5) (109,5) (25,4) 133 Inch 17-3/16 Cover Tamper Switches installed internal to the Waterflow Alarm Switches. ULC Listed Manifolds are equipped with NOTES: CH: Common Hardware2. 1. H C E D 4 Inch (DN80) 6 Inch (DN150) (DN100) A B Drain Valve (Normally Closed) 20-1/2 (436,6) 20-1/2 (520,7) (520,7) (330,2) (330,2) (330,2) 13 13 QTY. 2 INCH (DN50) MANIFOLD DESCRIPTION ULC/FM UL/FM Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, 2" Manifold Body, Groove x Groove 300 psi/2000 kPa Water Pressure Gauge 3 2 NO. 1 1............... .............. ..1 1 .......1 Manifold 2 Inch 2-1/2 Inch (DN50) (DN65) 976-357-01 976-520-01 2341 Size N/A P/N 16-3/4 17-3/16 (425,5) (436,6) A (330,2) (330,2) 13 13 B 3-1/2 18.77-1/86 14-1/4 1-1/4" NPT to "Drain") (Normally set & Drain Valve F Test (422,3) 16-5/8 (469,9) 18-1/2 (362,0) W a t e r f l o w 1 7-9/16 (152,4) (215,9) (192,1) 8-1/2 3 9-1/16 (181,0) 10 (254,0) (230,2) 2 4-1/2 (88,9) 6-5/8 (168,3) (114,3) 2" NPT 2" NPT G 32.7 (8,5) (18,9) 41.6 (14,8) Drain Size 1-1/4" NPT13-3/4 (331,8) 13-1/16 (349,3) (136,5) (146,1) 5-3/8 5-3/4 D 6-3/8 6-7/8 (161,9) (174,6) E 3-1/2 3-1/2 (88,9) (88,9) FG 1" NPT H Weight (6,1) 13.5 16.8 lbs. (kg) (7,6) 2 Waterflow Alarm Switch: 976-520-05 2341 976-357-05 VSC with Paddle, VSC with Paddle and Cover Tamper Switch, ULC/FM UL/FM Water Pressure Gauge 300 psi/2000 kPa3 1.. .............. ............... 1 1 P/N N/A 2341 976-520-04 976-357-04 N/A P/N 1...............UL/FM 300 psi/2000 kPa Water Pressure Gauge Cover Tamper Switch, VSC with Paddle and ULC/FM Groove x Groove 6" Manifold Body, DESCRIPTIONNO. 1 3 ....... 6 INCH (DN150) MANIFOLD QTY. 1 .............. 1.. 1 Groove x Groove 4" Manifold Body, DESCRIPTION Waterflow Alarm Switch: VSC with Paddle, 2 NO. 1 .......1 QTY. 4 INCH (DN100) MANIFOLD 1..............ULC/FM 976-520-02 2341Water Pressure Gauge 300 psi/2000 kPa3 ..1 976-357-02............... Groove x Groove 2-1/2" Manifold Body, Cover Tamper Switch, VSC with Paddle and VSC with Paddle, Waterflow Alarm Switch: DESCRIPTION 2-1/2 INCH (DN65) MANIFOLD 1 UL/FM 2 NO. ....... 1 N/A1 P/NQTY. 1..............ULC/FM 976-520-03 300 psi/2000 kPa Water Pressure Gauge 3 1. . 2341 ............... 3" Manifold Body, Groove x Groove Waterflow Alarm Switch: VSC with Paddle, VSC with Paddle and Cover Tamper Switch, DESCRIPTION 3 INCH (DN80) MANIFOLD 1 2 UL/FM NO. 1 .......1 976-357-03 N/A QTY. P/N Page4of6 TFP962 FIGURE 3 WIRING GUIDANCE INCOMING OUTGOING SINGLE CONDUCTOR TERMINAL PLATE LOOPED SECTION UNINSULATED CLAMPING CONDUCTORS SEPARATE STRIPPED ENDS SWITCH TERMINAL CONNECTIONS CLAMPING TERMINAL PLATE IMPROPER CONNECTION METHOD PROPER CONNECTION METHOD SEVERED CAUTION: An uninsulated section of a single conductor is not permitted to be looped around the terminal and serve as two separate connections. The wire must be severed to serve as two separate connections, thereby providing supervision of the connection in the event that the wire becomes dislodged from the terminal. WATERFLOW SWITCH TYPICAL ELECTRICA CONNECTIONS COM NCNO NO FLOW CONTACTS SPDT (Form C) 5A @ 125 VACCONTACT RATING 2.5A @ 30 VDC .......... .... COM NO NC POWER SIGNAL LOCAL DEVICE NON-SUPERVISED CIRCUITCONDITION END OF LINE RESISTOR COM SUPERVISED CIRCUIT STYLE B/CLASS B CONTROL NO NC PANEL signaling unit, while the other contact is used to operate a local audible or visual annunciator. Switch has two switches, one can be used to operate a central station, proprietary or remove For supervised circuits, see "Switch Terminal Connections" above. The Waterflow Alarm NOTE: (SEE NOTE) COVER TAMPER SWITCH (ULC ASSEMBLIES ONLY) CONTACTS SHOWN WITH COVER IN PLACE COM .......... ....CONTACT RATING NO CONTACTS 3A @ 250 VAC 5A @ 125 VAC NC SPDT (Form C) 1mA @ 5 VDC min. Care and Maintenance The following inspection procedure must be performed as indicated, in ad- dition to any specific requirements of the NFPA, and any impairment must be immediately corrected. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stallingcontractor orproductmanufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Noattemptistobemadetorepairany Riser Manifold component in the field. Only the pressure gauge, waterflow alarm switch, or relief valve can be replaced. If any other problems are encountered the entire riser manifold must be replaced. The alarm/flow test procedure will re- sult in operation of the associated alarms. Consequently, notification must be given to the owner and the fire department, central station, or other signal station to which the alarms are connected, and notification must be given to the building occupants. Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the effected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise thoseresponsibleformoni- toring proprietary and/or central sta- tion alarms. Alarm/Flow Test Procedure Step 1.Place the test & drain Valve in the “test” position. Step 2.Fully open the drain valve. Make certain that drainage water will not cause any damage or injury. Step 3.Verify operation of associated alarms. Step 4.Close the drain valve. Step 5.Place the test & drain Valve in the “drain” position. Step 6.Verify that the residual (flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. Step 7.Close the drain valve. Step 8.Verify that the static (not flow- ing) pressure indicated by the pres- sure gauge is no less that originally recorded for the system when it was first installed. TFP962 Page5of6 FIGURE 4 OPTIONAL PRESSURE RELIEF VALVE 1 system outlet piping, and a connection back 3/8" Copper Tubing, 2" (DN50) Manifolds 6" (DN150) Manifolds 4" (DN100) and 3" (DN80) Manifolds To install optional Pressure Relief Trim on must be provided by the installer on the a 1-1/2" (DN40) Manifold, a 1/2" NPT outlet 2-1/2" (DN65) and 1 1 1 .... ... .... 971-124-02 971-124-01 971-124-03 Pressure Relief Valve, DESCRIPTION 175 psi, Nonadjustable NO. 2 QTY. 1. . 198-066-00 P/N CH: Common Hardware with installer supplied 3/8" copper tubing. to the manifold drain trim must be fabricated 3 2 134 2 3 1-1/2" (DN40) Manifold Discard unused trim components. Fabricated 3/8" Copper Tubing Installer 1/2" NPT Outlet 90° Compression Fitting .............. 1" x 1/2" Reducing Hex4 Bushing 1 CH DESCRIPTIONNO. 3 QTY. P/N CH2................Fitting Manifold Drain Trim 3 Provided System Outlet Installer Piping 1-1/2" (DN40) Manifold Only: 2" (DN50), 2-1/2" (DN65), 6" (DN150) Manifold 3" (DN80), 4" (DN100), or Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which havebeensubjecttomisuse,improper installation,corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP’s sole option. TFBP neither assumes, nor authorizes any person to assume forit, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer’s repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,specialorconsequentialdam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP’s liability exceed an amount equal to the sales price. Theforegoingwarrantyismadeinlieu of any and all other warranties, ex- press or implied, including warranties ofmerchantabilityandfitnessforapar- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Information Riser Manifold: Specify; Size (specify), Figure 513, (specify connection type inlet x outlet) Riser Manifold (specify - without or with) a cover tamper switch for the waterflow alarm switch, P/N (specify). NOTES Orders for Figure 513 may be filled with a Figure 13. The two assemblies are completely interchangeable in function, application, and end-to-end laying length. If a ULC Listing is required, the Riser Manifold must be ordered with a cover tamper switch for the waterflow alarm switch. UL/ULC/FM Assemblies With Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4086 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4087 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4090 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4091 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4092 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4095 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4096 UL/FM Assemblies Without Cover Tamper Switch 1-1/2 Inch (DN40) MT x FT . . . . . . . . . . . . . . P/N 4055 1-1/2 Inch (DN40) MT x MT . . . . . . . . . . . . . . P/N 4056 2 Inch (DN50) G x G . . . . . . . . . . . . . . . . P/N 4060 2-1/2 Inch (DN65) G x G . . . . . . . . . . . . . . . . P/N 4061 3 Inch (DN80) G x G . . . . . . . . . . . . . . . . P/N 4062 4 Inch (DN100) G x G . . . . . . . . . . . . . . . . P/N 4065 6 Inch (DN150) G x G . . . . . . . . . . . . . . . . P/N 4066 Optional Pressure Relief Valve: Specify: Operational Pressure Relief Valve and Trim for use with (specify size) Figure 513 or 13 Series Riser Manifold, P/N (specify). 1-1/2" or 2". . . . . . . . . . . . . . . P/N 4063 2-1/2" or 3". . . . . . . . . . . . . . . P/N 4072 4" or 6" . . . . . . . . . . . . . . . . . . P/N 4073 Replacement Parts: Specify: (description) for use with Fig- ure 513 or 13 Riser Manifold,P/N (Ref. Figure 1 or 2, as applicable). Page6of6 TFP962 TYCO FIRE & BUILDING PRODUCTS,451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response Page 1 of 10 JUNE 2015 TFP560 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com NOTICE The Series DS-1 Stainless Steel Dry- Type Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. The Series DS-1 Stainless Steel Dry- Type Sprinklers must only be installed in fittings that meet the requirements of the Design Criteria section. • in systems that are seasonably drained to avoid freezing (e.g., vacation areas) The stainless steel construction of these sprinklers extends the life of a sprinkler beyond that of traditional copper alloy sprinklers exposed to corrosive atmospheres. Although corrosion-resistant sprinklers have passed the standard corrosion tests of the applicable approval agencies, the testing is not representative of all pos- sible corrosive atmospheres. Consequently, it is necessary that the end user be consulted with respect to the suitability of this alternate material of construction for any given corrosive environment. As a minimum, consider the following criteria: • ambient temperature • concentration of chemicals • humidity • gas/chemical velocity • corrosive nature of the chemical to which the sprinklers are exposed Stainless Steel Pendent Dry-Type Sprinklers The pendent sprinklers are provided with stainless steel escutcheons that allow vertical adjustment during instal- lation. This adjustment provides a measure of flexibility in determining the length of fixed piping to cut for sprin- kler drops. Stainless Steel Sidewall Dry-Type Sprinklers The horizontal sidewall sprinklers are designed for installation along a wall or side of a soffit and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent sprinklers due to aesthetics or build- ing construction considerations where piping along the ceiling is not desirable. General Description TYCO Series DS-1 Stainless Steel Dry- Type Sprinklers, 5.6K Pendent, Hori- zontal Sidewall (HSW), and Extended Coverage HSW, Standard (5 mm bulb) and Quick (3 mm bulb) Response are the first stainless steel dry-type sprin- klers to be listed by UL and C-UL. With a K-factor of 5.6, these corrosion-resis- tant automatic sprinklers can be used in wet-pipe, dry-pipe, or preaction systems. These pendent and horizontal sidewall sprinklers are available in a variety of configurations to suit coverage type and thermal sensitivity. Refer to the Sprinkler Identification Numbers (SINs) section for details. Series DS-1 Stainless Steel Dry-Type Sprinklers are typically used: • where corrosive atmospheres exist (e.g., salt-water areas, parking garages, chemical storage areas, mechanical rooms, industrial man- ufacturing sites, and software chip washing facilities) • on dry-pipe systems exposed to freezing temperatures (e.g., sprinkler drops from unheated portions of buildings) • with pipe connections exposed to freezing temperatures (e.g., sprinkler drops from wet-pipe systems into freezers or hori- zontal piping extensions to protect unheated areas) TFP560 Page 2 of 10 APPLICATION(1) Coverage(2) W x L, Ft. x Ft. (m x m) Minimum Flow, gpm (lpm) Minimum Pressure, psi (bar) Temperature Rating Top of Deflector-to-Ceiling Distance(2) TY3339 (3 mm Bulb) For Quick Response, Light Hazard, Extended Coverage per NFPA 13 16 x 16 (4,9 x 4,9) 26 (98) 21.6 (1,49) 135°F (57°C) and 155°F (68°C) 4 inches (100 mm) to 12 inches (300 mm) 16 x 18 (4,9 x 5,5) 29 (110) 26.8 (1,85) 16 x 20 (4,9 x 6,1) 32 (121) 32.7 (2,25) 18 x 16 (5,5 x 4,9) 29 (110) 26.8 (1,85) Notes: 1. These sprinklers are Listed by UL and C-UL. Stainless steel sprinklers noted to be UL and C-UL Listed are listed as Corrosion Resistant Sprinklers. 2. The minimum allowable spacing between sprinklers to prevent cold soldering is 14 feet (4,3 m). Temperature Rating Bulb Color Code Standard Coverage Extended Coverage Horizontal SidewallPendentHorizontal Sidewall TY3230 (3 mm Bulb) with Standard Escutcheon (Figure 10) with Recessed Escutcheon(a) (Figure 11) with Deep Escutcheon (Figure 12) without Escutcheon (Figure 13) TY3250 (5 mm Bulb) with Standard* Escutcheon (Figure 10) with Recessed Escutcheon(a) (Figure 11) with Deep* Escutcheon (Figure 12) without* Escutcheon (Figure 13) TY3337 (3 mm Bulb)(b) with Standard Escutcheon (Figure 14) with Deep Escutcheon (Figure 15) without Escutcheon (Figure 16) TY3357 (5 mm Bulb)(b) with Standard Escutcheon (Figure 14) with Deep Escutcheon (Figure 15) without Escutcheon (Figure 16) TY3339 (3 mm Bulb)(c) with Standard Escutcheon (Figure 17) 135°F (57°C)Orange 1, 2 1, 2 1**, 2**1**, 2**1***, 2*** 155°F (68°C)Red 1, 2 1, 2, 3*1**, 2**1**, 2**1***, 2*** 175°F (79°C)Yellow 1, 2 1, 2 1**, 2**1**, 2**N/A 200°F (93°C)Green 1, 2 1, 2, 3*1**, 2**1**, 2**N/A 286°F (141°C)Blue 1, 2 1, 2, 3*1**, 2**1**, 2**N/A 360°F (182°C)Mauve N/A 1, 2 N/A 1**, 2**N/A Notes: 1. Listed by Underwriters Laboratories, Inc. (UL). Stainless steel sprinklers noted to be UL Listed are listed as Corrosion Resistant Sprinklers. Maximum order lengths are de- scribed in Figures 10 through 17. 2. Listed by Underwriters Laboratories for use in Canada (C-UL). Stainless steel sprinklers noted to be C-UL Listed are listed as Corrosion Resistant Sprinklers. Maximum order lengths are described in Figures 10 through 17. 3. Loss Prevention Certification Board (LPCB) approval and CE conformity apply to these temperature ratings only. a. This configuration is applicable only up to 286°F (141°C). b. To meet the deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm) for the standard coverage horizontal sidewall, the centerline of the sprinkler waterway must be 4-5/16 to 12-5/16 inches below the ceiling. c. To meet the deflector-to-ceiling distance of 4 to 12 inches (100 to 300 mm) for the extended coverage horizontal sidewall, the centerline of the sprinkler waterway must be 4-7/16 to 12-7/16 inches below the ceiling. * LPCB approval and CE conformity apply to only these configurations for TY3250 with only these indicated temperatures. ** Light and Ordinary Hazard Occupancies only *** Light Hazard Occupancies only N/A – Not Applicable TABLE B SERIES DS-1 STAINLESS STEEL DRY-TYPE HORIZONTAL SIDEWALL EXTENDED COVERAGE SPRINKLERS UL AND C-UL INSTALLATION CRITERIA TABLE A SERIES DS-1 STAINLESS STEEL DRY-TYPE PENDENT AND HORIZONTAL SIDEWALL STANDARD AND EXTENDED COVERAGE SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP560 Page 3 of 10 Operation When TYCO Series DS-1 Stain- less Steel Dry-Type Sprinklers, 5.6K Pendent, Horizontal Sidewall (HSW), and Extended Coverage HSW, Stan- dard (5 mm bulb) and Quick (3 mm bulb) Response are in service, water is prevented from entering the assem- bly by the Plug with Sealing Assem- bly in the Inlet of the sprinkler. Refer to Figures 1 through 3. The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb then release the Bulb Seat. The compressed Spring is then able to expand and push the Water Tube as well as the Guide Tube outward. This outward action simultaneously pulls inward on the Yoke, withdrawing the Plug with Sealing Assembly from the Inlet and allowing the sprinkler to acti- vate and flow water effectively. Design Criteria TYCO Series DS-1 Stainless Steel Dry- Type Sprinklers, 5.6K Pendent, Hori- zontal Sidewall (HSW), and Extended Coverage HSW, Standard (5 mm bulb) and Quick (3 mm bulb) Response are intended for use in fire sprinkler systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on NFPA 13 requirements). For more information on LPCB Approval, contact Tyco Fire Protection Products at the following office: Kopersteden 1 7547 TJ Enschede The Netherlands Tel: +31-(0)53-428-4444 Fax: +31-(0)53-428-3377 The Series DS-1 Stainless Steel Extended Coverage Sprinklers are intended for use in fire sprinkler systems designed in accordance with extended coverage installation guide- lines provided by NFPA 13 and the installation criteria provided by Table B. Sprinkler Identification Numbers (SINs) Standard Coverage Pendent • TY3230 – 3 mm Bulb • TY3250 – 5 mm Bulb Standard Coverage Horizontal Sidewall • TY3337 – 3 mm Bulb • TY3357 – 5 mm Bulb Extended Coverage Horizontal Sidewall • TY3339 – 3 mm Bulb Technical Data Approvals UL and C-UL Listed LPCB Approved: Ref. No. 094a/12 CE Certified: EN 12259-1 (Refer to Tables A and B for details) Maximum Working Pressure 175 psi (12,1 bar) Inlet Thread Connections 1-Inch NPT or ISO 7-R 1 Discharge Coefficient K=5.6 gpm/psi1/2 (80,6 lpm/bar1/2) Temperature Ratings Refer to Tables A and B Finishes Sprinkler: Stainless Steel Escutcheon: Stainless Steel Physical Characteristics With the exceptions of the bulb, the Insert, the Deflector, and the Sealing Assem-bly, all components of the Series DS-1 Stainless Steel Dry-Type Sprinkler are constructed with Type 316 Stainless Steel.• The bulb is glass. • The Insert is 300 Series Stainless Steel.• The Deflector is Type 316L Stainless Steel. The Sealing Assembly consists of a Disc Spring that is sealed on both its inside and outside faces with a TEFLON gasket. The Disc Spring is 1/2 Hard Beryllium Nickel.Refer to Figures 1 through 3 for compo- nent assemblies. Sprinkler Fittings Install the 1 inch NPT Series DS-1 Stainless Steel Dry-Type Sprinkler in the 1 inch NPT outlet or run of one of the following fittings: • malleable or ductile iron threaded tee fittings that meet the dimen- sional requirements of ANSI B16.3 (Class 150) • cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125) • cast bronze threaded tee fittings that meet the dimensional require- ments of ANSI B16.15 (Class 125) • stainless steel threaded tee fittings that meet the dimensional require- ments of MSS SP-114. Do not install the Series DS-1 Stainless Steel Dry-Type Sprinklers into elbow fittings. The inlet of the sprinkler can contact the interior of the elbow, poten- tially damaging the Inlet seal. The unused outlet of the threaded tee is plugged as shown in Figures 4 and 5. You can also install the Series DS-1 Sprinklers in the 1 Inch NPT outlet of a GRINNELL Figure 730 Mechanical Tee. However, the use of the Figure 730 Tee for this arrangement is limited to wet- pipe systems. The configuration shown in Figure 4 is only applicable for wet-pipe systems where the sprinkler fitting and water- filled pipe above the sprinkler fitting are not subject to freezing and where the length of the Stainless Steel Dry-Type Sprinkler has the minimum exposure length depicted in Figure 6. Refer to the Exposure Length section. For wet-pipe system installations of the 1 Inch NPT Series DS-1 Stainless Steel Dry-Type Sprinklers connected to CPVC piping, use only the following TYCO CPVC fittings: • 1” x 1” NPT Female Adapter (P/N 80145) • 1” x 1” x 1” NPT Sprinkler Head Adapter Tee (P/N 80249) For dry-pipe system installations, use only the side outlet of maximum 2-1/2 inch reducing tee when locating the Series DS-1 Stainless Steel Dry-Type Sprinklers directly below the branch line. Otherwise, use the configuration shown in Figure 5 to assure complete water drainage from above the Series DS-1 Stainless Steel Dry-Type Sprin- klers and the branchline. Failure to do so may result in pipe freezing and water damage. TFP560 Page 4 of 10 3 or 5 mm BULB WATER TUBE VENT HOLE GUIDE TUBE INSERT YOKE SCREW INLET SEALING PLUG WITH CASING DEFLECTOR BULB SPRING COMPRESSION SEAT ASSEMBLY FRAME INLET BAND WATER TUBE GUIDE TUBE HOLEINLET INSERT DEFLECTOR3 or 5 mm SCREW COMPRESSION SEALING PLUG WITH BULB SEAT YOKE 1" NPT CASING SPRING VENT FRAME BULB ASSEMBLY BAND INLET WATER TUBE GUIDE TUBE HOLEINLET INSERT DEFLECTOR3 mm SCREW COMPRESSION SEALING PLUG WITH BULB SEAT YOKE 1" NPT CASING SPRING VENT FRAME BULB ASSEMBLY BAND INLET FIGURE 3 SERIES DS-1 STAINLESS STEEL DRY-TYPE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER TY3339 (3 MM BULB) FIGURE 1 SERIES DS-1 STAINLESS STEEL DRY-TYPE STANDARD COVERAGE PENDENT SPRINKLERS TY3230 (3 MM BULB) AND TY3250 (5 MM BULB) FIGURE 2 SERIES DS-1 STAINLESS STEEL DRY-TYPE STANDARD COVERAGE HORIZONTAL SIDEWALL SPRINKLER TY3337 (3 MM BULB) AND TY3357 (5 MM BULB) TFP560 Page 5 of 10 NOTICE Do not install the Series DS-1 Stainless Steel Dry-Type Sprinklers into any other type fitting without first consulting the Technical Services Department. Failure to use the appropriate fitting can result in one of the following: • failure of the sprinkler to operate properly due to formation of ice over the Inlet Plug or binding of the Inlet Plug • insufficient engagement of the In- let pipe threads with consequent leakage Drainage In accordance with the minimum requirements of the National Fire Protection Association for dry-pipe sprinkler systems, pitch branch, cross, and feed main piping connected to Stainless Steel Dry-Type Sprinklers and subject to freezing temperatures to allow proper drainage. Exposure Length When using Stainless Steel Dry- Type Sprinklers in wet-pipe sprinkler systems protecting areas subject to freezing temperatures, use Table C to determine a sprinkler’s appropriate exposed barrel length to prevent water from freezing in the connecting pipes due to conduction. The exposed barrel length measurement must be taken from the face of the sprinkler fitting to the surface of the structure or insula- tion that is exposed to the heated area. Refer to Figure 6 for an example. Clearance Space Section 8.4.9.2 of 2010 edition of NFPA 13 requires a sealed clearance space around the sprinkler barrel of dry sprin- klers that are connected to wet-pipe sprinkler systems protecting insulated freezer structures. The use of the Model DSB-2 Dry Sprinkler Boot, described in technical data sheet TFP591 and illus- trated in Figures 7 and 8, meets this NFPA 13 requirement. HEATED AREA (SEE DESIGN CRITERIA SECTION) FACE OF SPRINKLER FITTING LENGTH EXPOSURE DSB-2 BOOT AREA SUBJECT TO FREEZING RUN OUTLET PLUGGED TO DRY SYSTEM DSB-2 BOOT FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER (ENDS ON OPPOSING SIDES OF BOOT) STRAP TIES ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE FREEZER STRUCTURE OR EXTERIOR INSULATED CEILING EXPOSED DSB-2 BOOT TO FREEZING SIDE OUTLET PLUGGED TO WET SYSTEM FITTING (SEE DESIGN CRITERIA SECTION) SPRINKLER DSB-2 BOOT HEATED AREA (ENDS ON OPPOSING SIDES OF STRAP TIES BOOT) ADHESIVE SHOWN WITH STANDARD ESCUTCHEON DS-1 1-3/4" DIA. (44,5 mm) CLEARANCE HOLE DSB-2 BOOT FREEZER STRUCTURE OR EXTERIOR INSULATED WALL EXPOSED TO FREEZING WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA SPRINKLER WRENCHING AREA FIGURE 4 SPRINKLER FITTING HEATED AREA FIGURE 5 SPRINKLER FITTING UNHEATED AREA FIGURE 6 EXPOSURE LENGTH FIGURE 8 MODEL DSB-2 SPRINKLER BOOT HORIZONTAL SIDEWALL APPLICATION FIGURE 7 MODEL DSB-2 SPRINKLER BOOT PENDENT APPLICATION FIGURE 9 W-TYPE 7 SPRINKLER WRENCH TFP560 Page 6 of 10 Installation TYCO Series DS-1 Stainless Steel Dry- Type Sprinklers, 5.6K Pendent, Hori- zontal Sidewall (HSW), and Extended Coverage HSW, Standard (5 mm bulb) and Quick (3 mm bulb) Response must be installed in accordance with this section. NOTICE The Series DS-1 must only be installed in fittings that meet the requirements of the Design Criteria section. For other important requirements regard- ing piping design and sealing of the clearance space around the Sprinkler Casing, refer to the Design Criteria section. Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) rating to 1/8 inch (3,2 mm) for the 286°F (141°C) rating. A leak-tight 1 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 20 to 30 ft.-lbs. (26,8 to 40,2 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over-tightening the Sprinkler. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install pendent sprinklers only in the pendent position with the deflector parallel to the ceiling. Install horizontal sidewall sprinklers in the hor- izontal position with their center-line of waterway perpendicular to the back wall and parallel to the ceiling. Ensure the word “TOP” on the Deflector faces the ceiling. Step 2. With a non-hardening pipe thread sealant such as TEFLON applied to the Inlet threads, hand-tighten the sprinkler into the sprinkler fitting. Step 3. Wrench-tighten the sprinkler using a pipe wrench on the Inlet Band or Casing (refer to Figures 1 to 3) or using the W-Type 7 Sprinkler Wrench on the Wrench Flat (refer to Figure 9). Note: If sprinkler removal becomes necessary, remove the sprinkler using the same wrenching method noted above. Sprinkler removal is easier when a non-hardening sealant was used and torque guidelines were followed. After removal, inspect the sprinkler for damage. Step 4. After installing the ceiling or wall and applying a ceiling finish, slide on the outer piece of the Escutcheon until it comes in contact with the ceiling or wall. Do not lift the ceiling panel out of its normal position. When using the Deep Escutcheon, hold the outer piece in contact with the mounting surface (ceiling or wall). Then rotate the inner piece approximately 1/4 turn, with respect to the outer piece, to hold the Deep Escutcheon firmly together. Ambient Temperature Exposed to Discharge End of Sprinkler Temperatures for Heated Area(a) 40°F (4°C) 50°F (10°C) 60°F (16°C) Minimum Exposed Barrel Length (b), Inches (mm) 40°F (4°C)0 0 0 30°F (-1°C)0 0 0 20°F (-7°C) 4 (100)0 0 10°F (-12°C) 8 (200) 1 (25)0 0°F (-18°C) 12 (305) 3 (75)0 -10 °F (-23°C) 14 (355) 4 (100) 1 (25) -20°F (-29°C) 14 (355) 6 (150) 3 (75) -30°F (-34°C) 16 (405) 8 (200) 4 (100) -40°F (-40°C) 18 (455) 8 (200) 4 (100) -50°F (-46°C) 20 (510) 10 (255) 6 (150) -60°F (-51°C) 20 (510) 10 (255) 6 (150) Notes: a. For protected area temperatures that occur between values listed above, use the next cooler temperature. b. These lengths are inclusive of wind velocities up to 30 mph (18,6 kph). TABLE C EXPOSED SPRINKLER BARRELS IN WET-PIPE SYSTEMS MINIMUM RECOMMENDED LENGTHS TFP560 Page 7 of 10 ORDER LENGTHS: (69,9 to 1219,2 mm) 2-3/4" to 48" IN 1/4" (6,4 mm) INCREMENTS FITTING FACE OF SPRINKLER SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) (76,2 mm) 3" DIA. 1-3/4" DIA. (44,5 mm) (55,6 ± 3,2 mm) 2-3/16" ± 1/8" CEILING FACE OF SPRINKLER FACE OF FITTING (127,0 to 1219,2 mm) INCREMENTS IN 1/4" (6,4 mm) ORDER LENGTHS: 5" to 48" DEFLECTOR TO CEILING 1-3/4" (44,5 mm) MINIMUM SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) 2-1/4" DIA. (57,2 mm) 1-3/8" ± 1/8" (34,9 ± 3,2 mm) 2-7/8" DIA. (73,0 mm) IN 1/4" (6,4 mm) 3-3/4" to 48" INCREMENTS (95,3 to 1219,2 mm) ORDER LENGTHS: SPRINKLER FACE OF FITTING CEILING FACE OF CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING ORDER LENGTHS: INCREMENTS 4-1/4" ± 1/8" (108,0 ± 3,2 mm) IN 1/4" (6,4 mm) (12,7 to 1168,4 mm) 1/2" to 46" FACE OF CEILING (88,9 mm) 3-1/2" DIA. 2-1/2" DIA. (63,5 mm) FITTING FACE OF SPRINKLER CRITERIA SECTION) (REFER TO DESIGN SPRINKLER FITTING FIGURE 13 PENDENT WITHOUT ESCUTCHEON TY3230 (3 MM BULB) AND TY3250 (5 MM BULB) FIGURE 12 PENDENT WITH DEEP ESCUTCHEON TY3230 (3 MM BULB) AND TY3250 (5 MM BULB) FIGURE 10 PENDENT WITH STANDARD ESCUTCHEON TY3230 (3 MM BULB) AND TY3250 (5 MM BULB) FIGURE 11 PENDENT WITH RECESSED ESCUTCHEON TY3230 (3 MM BULB) AND TY3250 (5 MM BULB) TFP560 Page 8 of 10 Care must be exercised to avoid damage to the sprinklers - before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. A Vent Hole is provided in the Bulb Seat to indicate if the Dry Sprinkler is remain- ing dry. (Refer to Figures 1 through 3.) Evidence of leakage from the Vent Hole indicates potential leakage past the Inlet seal and the need to remove the sprinkler to determine the cause of leakage; for example, an improper installation or an ice plug. Close the fire protection system control valve and drain the system before removing the sprinkler. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care and Maintenance TYCO Series DS-1 Stainless Steel Dry-Type Sprinklers, 5.6K Pendent, Horizontal Sidewall (HSW), and Extended Coverage HSW, Standard (5 mm bulb) and Quick (3 mm bulb) Response must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY 1-3/4" DIA. (44,5 mm) FACE OF MOUNTING SURFACE ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3" DIA. (76,2 mm) 5/16" (7,9 mm) 2-3/8" ± 1/8" (60,3 ± 3,2 mm) 3.5° FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY FACE OF MOUNTING SURFACE ORDER LENGTHS: 1/2" to 45-3/4" (12,7 to 1162,1 mm) IN 1/4" (6,4 mm) INCREMENTS 5/16" (7,9 mm) 3.5° 2-1/2" DIA. (63,5 mm) 4-1/4" ± 1/8" (108,0 ± 3,2 mm) 3-1/2" DIA. (88,9 mm) FIGURE 14 STANDARD COVERAGE HORIZONTAL SIDEWALL WITH STANDARD ESCUTCHEON TY3337 (3 MM BULB) AND TY3357 (5 MM BULB) FIGURE 15 STANDARD COVERAGE HORIZONTAL SIDEWALL WITH DEEP ESCUTCHEON TY3337 (3 MM BULB) AND TY3357 (5 MM BULB) TFP560 Page 9 of 10 Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product description and Part Number (P/N). Refer to the price list for a complete listing of part numbers. Part numbers are for 1 inch NPT stand ard order sprinklers. Orders for all other sprinkler assemblies must be accompanied by a complete description. Stainless Steel Dry-Type Sprinkler When ordering Series DS-1 Stain- less Steel Dry-Type Sprinklers, 5.6K Pendent, Horizontal Sidewall (HSW), and Extended Coverage HSW, Stan- dard (5 mm bulb) and Quick (3 mm bulb) Response, specify the following information: • SIN Standard Coverage Pendent TY3230 – Quick Response TY3250 – Standard Response Standard Coverage Horizontal Sidewall TY3337 – Quick Response TY3357 – Standard Response Extended Coverage Horizontal SidewallTY3339 – Quick Response • Order Length: Dry-Type Sprinklers are furnished based upon Order Length as mea- sured per Figures 10 through 17, as applicable. Measure the required length and then round the mea- surement to the nearest 1/4 inch increment. • Inlet Connections: 1 Inch NPT (Standard) ISO 7-R 1 (For information on ISO Inlet Thread Connections, contact your Tyco Sales Representative.) • Temperature Rating(Temperature rating 360°F (182°C) applies to non-recessed sprinkler assemblies.) • Escutcheon Type, as applicable • Part Number from Table D Sprinkler Wrench Specify W-Type 7 Sprinkler Wrench P/N 56-850-4-001 Sprinkler Boot Specify Model DSB-2 Dry Sprinkler Boot, P/N 63-000-0-002 This P/N includes one (1) Boot, two (2) Strap Ties, and 1/3 oz. of Adhesive (a sufficient quantity for installing one boot). 3.5°5/16" (7,9 mm) CENTERLINE OF WATERWAY FITTING SPRINKLER FACE OF 2-1/4" (57,2 mm) DEFLECTOR TO 5-1/2" to 48" (139,7 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS ORDER LENGTHS: MINIMUM MOUNTING SURFACE SPRINKLER FITTING CRITERIA SECTION) (REFER TO DESIGN FACE OF SPRINKLER FITTING SPRINKLER FITTING (REFER TO DESIGN CRITERIA SECTION) CENTERLINE OF WATERWAY 1-3/4" DIA. (44,5 mm) FACE OF MOUNTING SURFACE ORDER LENGTHS: 2-3/4" to 48" (69,9 to 1219,2 mm) IN 1/4" (6,4 mm) INCREMENTS 3" DIA. (76,2 mm) 2-3/8" ± 1/8" (60,3 ± 3,2 mm) 7/16" (11,1 mm) FIGURE 16 STANDARD COVERAGE HORIZONTAL SIDEWALL WITHOUT ESCUTCHEON TY3337 (3 MM BULB) AND TY3357 (5 MM BULB) FIGURE 17 EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER WITH STANDARD ESCUTCHEON TY3339 (3 MM BULB) GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700 TFP560 Page 10 of 10 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of the DuPont Corporation Notes: 1. Dry-Type Sprinklers are furnished based upon “Order Length” as measured per Figures 10 through 17 and for each individual sprin- kler where it is to be installed. After taking the measurement, round it to the nearest 1/4 inch increment. 2. Temperature rating 360°F (182°C) applies to non-recessed sprinkler assemblies. * Use Prefix “I” for ISO 7-R 1 Connection (e.g., I-60-110-6-055). P/N* 60 – XXX – X– XXX SIN 11 SS Pendent Quick Response with Standard Escutcheon (1” NPT)TY3230 (Figure 10) 12 SS Pendent Quick Response with Recessed Escutcheon (1” NPT) TY3230 (Figure 11) 13 SS Pendent Quick Response with Deep Escutcheon (1” NPT)TY3230 (Figure 12) 14 SS Pendent Quick Response without Escutcheon (1” NPT) TY3230 (Figure 13) 21 SS Pendent Standard Response with Standard Escutcheon (1” NPT) TY3250 (Figure 10) 22 SS Pendent Standard Response with Recessed Escutcheon (1” NPT)TY3250 (Figure 11) 23 SS Pendent Standard Response with Deep Escutcheon (1” NPT) TY3250 (Figure 12) 24 SS Pendent Standard Response without Escutcheon (1” NPT)TY3250 (Figure 13) 15 SS HSW Quick Response Standard Coverage with Standard Escutcheon (1” NPT) TY3337 (Figure 14) 16 SS HSW Quick Response Standard Coverage with Deep Escutcheon (1” NPT) TY3337 (Figure 15) 17 SS HSW Quick Response Standard Coverage without Escutcheon (1” NPT) TY3337 (Figure 16) 25 SS HSW Standard Response Standard Coverage with Standard Escutcheon (1” NPT) TY3357 (Figure 14) 26 SS HSW Standard Response Standard Coverage with Deep Escutcheon (1” NPT) TY3357 (Figure 15) 27 SS HSW Standard Response Standard Coverage without Escutcheon (1” NPT) TY3357 (Figure 16) 18 SS HSW Quick Response Extended Coverage with Standard Escutcheon (1” NPT) TY3339 (Figure 17) ORDER LENGTH EXAMPLES(1) 055 5.50” 082 8.25” 180 18.00” 187 18.75” 372 37.25” 480 48.00” FINISH 6 Stainless Steel for Sprinkler and Escutcheon TEMPERATURE RATING (2) 0 135°F (57°C) 1 155°F (68°C) 2 175°F (79°C) 3 200°F (93°C) 4 286°F (141°C) 5 360°F (182°C) TABLE D SERIES DS-1 STAINLESS STEEL DRY-TYPE SPRINKLERS PART NUMBER SELECTION