HomeMy WebLinkAboutRESCHECK - 17-00264 - 1220 Franklin Dr - SFRfZGenerated by REScheck-Web Software Compliance Certificate Project Brooklyn Plan Energy Code: 2012 IECC 0.0 Location: Rexburg, Idaho 1,833 Construction Type: Single-family 0.050 Project Type: New Construction Conditioned Floor Area: 4,238 ft2 16 Glazing Area 19% Climate Zone: 6 (8693 HDD) 278 Permit Date: 0.270 Permit Number: 2,141 19.0 Construction Site: Owner/Agent: Designer/Contractor: 1,120 19.0 Justin Stevens 0.036 39 Stevens Homes PO Box 2759 16 713 Idaho Falls, Idaho 83403 3.0 0.037 208-206-1919 justin@stevenshomes.com Compliance: Passes using UA trade-off Compliance: 4.3% Better Than Code Maximum UA: 422 Your UA: 404 The %Better or worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling: Flat or Scissor Truss Wall: Wood Frame, 16in. o.c. Door: Solid Glass Door: Glass Window: Vinyl Frame, 2 Pane w/ Low -E Floor: All -Wood joist/Truss Over Uncond. Space Basement: Solid Concrete or Masonry Wall height: 9.0' Depth below grade: 8.9' Insulation depth: 9.0' Door: Solid Basement: Wood Frame Wall height: 9.0' Depth below grade: 8.9' - Insulation depth: 9.0' Project Title: Brooklyn Plan Data filename: 2,141 50.0 0.0 0.026 56 1,833 19.0 3.0 0.050 73 42 0.390 16 63 0.270 17 278 0.270 75 2,141 19.0 4.0 0.040 86 1,120 19.0 3.0 0.036 39 40 0.390 16 713 19.0 3.0 0.037 26 Report date: 05/15/17 Page 1 of 9 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory require "ste&,nhe R 5 nspection Checist. kshll GKJ �4 a- Bull),r� Name - Title h Sinnur 7 n�ro Project Notes: Brooklyn Plan Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 2 of 9 1ZREScheck Software Version 5.5.0 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Vered Value Field Verified Value Complies? Comments/Assumptions & Re .ID 103.1, ! Construction drawings and _ ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1)1 energy code compliance for the -building ❑Not Observable envelope. ❑Not Applicable 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate❑Does Not 403.7 [PR3)1 !lighting energy code compliance for and mechanical systems. -❑Not observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.6 'sized per ACOA Manual S based Btu/hr Btu/hr ❑Does Not [PR211on loads calculated per ACCA Cooling: Cooling: ❑Not Observable U. Manual J or other methods approved by the code official. Btu/hr Btu/hr Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 2 1 Medium Impact (Tier 2) -3 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 3 of 9 Section # Foundation Inspection plans Verified Value Field Verified Value Complies? Comments/Assumptions & Re .ID 402.1.1 'Conditioned basement wall ! R. IR- ❑Complies !See the Envelope Assemblies [FO4]' insulation R -value. Where interior R- R- !❑Does Not !table for values. V, insulation is used, verification Observable may need to occur during❑Not Insulation Inspection. Not,❑Not Applicable required in warm -humid locations -. in Climate Zone 3. 303.2 !Conditioned basement wall -!❑Complies [FOS]' insulation installed per -❑Does Not manufacturer's instructions. ❑Not Observable j ❑Not Applicable 402.2.8 Conditioned basement wall it ft ❑Complies :See the Envelope Assemblies [FO6]' insulation depth of burial or ❑Does Not :table for values. distance from top of wall. ❑Not Observable ❑Not Applicable j 303.2.1 A protective covering is installed ❑Complies (FO11)2 to protect exposed exterior❑Does Not insulation and extends a ❑Not Observable ' minimum of 6 in. below grade. Applicable 403.8 Snow- and ice -melting systemIyy,,- _❑Not ❑Complies [FO12]' controls installed. P"." ❑Does Not U' ❑Not Observable ❑Not Applicable, Additional Comments/Assumptions; 1 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 4 of 9 Section # Framing /Rough-In Inspection Pians Verified Value Field Verified Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U-factor. U- U- :❑Complies ;See the Envelope Assemblies 402.3.4 :❑Does Not :table for values. [FR1]3-❑Not 0 Observable .❑Not Applicable 402.1.1, Glazing U-factor (area-weighted U- U- :❑Complies ;See the Envelope Assemblies 402.3.1, average).❑Does Not 'table for values. 402.3.3, 402.3.6,❑Not Observable 402.5 ❑Not Applicable [FR21' 303.1.3 U-factors of fenestration products'. [FR4]1 are determined in accordance-❑Does '"]Complies Not with the NFRC test procedure or 1.❑Not Observable taken from the default table. I❑Not Applicable 402.4.1.1 Air barrier and thermal barrier❑Complies [FR23]1 installed per manufacturer's --.IDDoes Not instructions. '.❑No[Observable ❑Not Applicable 402.4.3 ;Fenestration that is not site built []Complies (FR2011 is listed and labeled as meeting f❑Does Not ,10 AAMA /WDMA/CSA 101/LS.2/A440❑Not Observable or has infiltration rates per NFRC []Not 400 that do not exceed code Applicable limits. 402.4.4 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/i nterior finish ❑Does Not and labeled to indicate 52.0 cfm ❑Not Observable leakage at 75 Pa. ❑Not Applicable; 403.2.1 Supply ducts in attics are R- R- ❑Complies [FR1211 insulated to 2:R-8. All other ducts R- R- ❑Does Not in unconditioned spaces or []Not Observable outside the building envelope are ❑Not Applicable insulated to 2:R-6. 403.2.2 All joints and seams of air ducts, ❑Complies [FR1311 air handlers, and filter boxes are ❑Does Not sealed. ❑Not Observable Applicable j 403.2.3 Building cavities are not used as _❑Not ❑Complies [FR15]3 ducts or plenums, ❑Does Not 4 '..❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R. ❑Complies [FR171' above 105 °F or chilled fluids ❑Does Not below 55 "F are insulated to aR- ❑Not Observable I y3 ❑Not Applicable j 403.3.1 :Protection of insulation on HVAC ❑Complies [FR24)1 'piping. {;.., ❑Does Not '.❑Not Observable 1.',..,-..❑Not Applicable j 403.4.2 Hot water pipes are insulated to R- R- [Complies [FR1612 2:R-3. ❑Does Not •J []Not Observable []Not Applicable 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13'1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 5 of 9 section Plans Verified Field Verified ^# Framing/ Rough -in inspection Value Value Compiles? Comments/Assumptions 403.5 ;Automatic or gravity dampers are ILJComphes [FR19]2 installed on all outdoor air ❑Does Not ,� intakes and exhausts. Ir ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) fffimedium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 6 of 9 Section # Insulation Inspection pians Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 3031. !All installed insulation is labeled ❑Complies [IN1312 or the installed R -values ❑Does Not ;e provided. ❑Not Observable ; ❑Not Applicable 402.1.1, Floor Insulation R -value. R- R- ❑Complies ;See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [INlp ❑ Steel, ❑ Steel ❑Not Observable ❑Not Applicable 303.2, ;Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions, and ❑Does Not [IN211 '', in substantial contact with the ❑Not Observable underside of the subfloor. ❑Not Applicable 402.1.1, (Wall insulation R -value. If this is a'. R- R- ❑Complies ;See the Envelope Assemblies 402.2.5, i mass wall with at least 1/l of the ❑ Wood j ❑ Wood ❑Does Not ;table for values. 402.2.6 '.wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN311 ',exterior, the exterior insulation ❑ Steel ❑ Steel❑Not Applicable . requirement applies (FR10). 303.2 iWall insulation is installed per ❑Complies [IN411 'manufacturer's instructions.❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1 3 1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 7 of 9 Section # Final Inspection Provisions Plans Vered Value Field Verified Value Complies? Comments/Assumptions. & Re .ID _ 402.1.1, 'Ceiling insulation R -value. R- R -❑Complies ;See the Envelope Assemblies 402.2.1, Wood : ❑ Wood❑Does Not ;table for values. 402'2'2' 402.2.6 ❑ Steel E] Steel j❑Not Observable [Fill' []Not Applicable 303.1.1.1, Ceiling insulation installed per❑Complies 303.2 manufacturer's Instructions. !'_ ❑Does Not [FI2)1 Blown insulation marked every U. 300 ft'. ❑Not Observable - Applicable j 402.2.3 Vented attics with air permeable __ _❑Not mplies [FI22)2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ❑Not Observable extends over insulation. ❑Not Applicable 402.2.4 .Attic access hatch and door R- R- ❑Complies [FI311 insulation aR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 .Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies , [F[17]1 :ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable j ❑Not Applicable 403.2.2 '.. Duct tightness test result of <=4 ; cfm/100 cfm/100❑Complies [F1411 'cfm/100 ft2 across the system or ; ff' ft� 1❑Does Not <=3 cfm/100 ft2 without air❑Not Observable handler @ 25 Pa. For rough -in tests, verification may need to❑Not Applicable occur during Framing Inspection. 403.2.2.1 ;Air handler leakage designated - 3 _; - ❑Complies (FI24]1 : by manufacturer at<=2%of € []Does Not design air flow. [_]Not Observable j ❑Not Applicable 403.1.1 Programmable thermostats - .❑Complies [Fl9]' installed on forced air furnaces.y; f 5 . •- ❑Does Not ❑Not Observable ,f ❑Not Applicable 403.1.2 'Heat pump thermostat installed �,= - .- ❑Complies [F110]2 on heat pumps. ..: - $- ❑Does Not []Not Observable -',,... ;,.. []Not Applicable j 403.4.1 Circulating service hot water - -'- ❑Complies [FI11]2 systems have automatic or ¢�" - ❑Does Not accessible manual controls.a�" _'"' ❑Not Observable --` []Not Applicable 403.5.1 All mechanical ventilation system .. - - - ❑Complies [F1251' fans not part of tested and listed - []Does Not HVAC equipment meet efficacy - ti - r []Not Observable and air flow limits. []Not Applicable 404.1 :75% of lamps in permanent 'r-' 'v:+❑Complies (FI611 Ifixtures or 75% of permanent ".❑Does Not U, Ifixtures have high efficacy lamps.❑Not Observable Does not apply to low -voltage lighting. ❑Not Applicable 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 8 of 9 Section # Final Inspection Provisions Plans Verifled Field Verified Value Value Compiles? Comments/Assumptions & Req.ID 404.1.1 iFuel gas lighting systems have ❑Complies �``F�t��*�RM-61 (F123]3 no continuous pilot light. p�❑Does No[ ❑Not Observable Applicable 401.3 -,Compliance certificate posted. `;.. ❑Complies [FI7]2?❑Does Not ❑Not Observable ❑Not Applicable j 303.3 Manufacturer manuals for❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Brooklyn Plan Report date: 05/15/17 Data filename: Page 9 of 9 fz2012 IECC Energy Efficiency Certificate Above -Grade Wall 22.00 Below -Grade Wall 22.00 Floor 23.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.27 Door 0.27 Heating System: Cooling System: Water Heater: Name: Date: Comments