Loading...
HomeMy WebLinkAboutSTRUCTURAL ENGINEERING - 16-00689 - Central Storage - New UnitsPR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S1.0 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 GE N E R A L S T R U C T U R A L N O T E S .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . . 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E GENERAL STRUCTURAL NOTES (APPLY UNLESS NOTED OTHERWISE ON PLANS/DETAILS) GENERAL REQUIREMENTS: 1.THE STRUCTURAL SYSTEMS AND MEMBERS DEPICTED HEREIN HAVE BEEN DESIGNED PRIMARILY TO SAFEGUARD AGAINST MAJOR STRUCTURAL DAMAGE AND LOSS OF LIFE, NOT TO LIMIT DAMAGE OR MAINTAIN FUNCTION (IBC SECTION 101.3). 2.THESE DRAWINGS, AND THEIR ASSOCIATED STRUCTURAL CALCULATIONS, HAVE BEEN PERFORMED USING STANDARDS OF PROFESSIONAL CARE AND COMPLETENESS NORMALLY EXERCISED UNDER SIMILAR CIRCUMSTANCES BY REPUTABLE STRUCTURAL ENGINEER'S IN THIS OR SIMILAR LOCALITIES. THEY NECESSARILY ASSUME THAT THE WORK DEPICTED WILL BE PERFORMED BY AN EXPERIENCED CONTRACTOR AND/OR WORKMEN WHO HAVE A WORKING KNOWLEDGE OF THE INTERNATIONAL BUILDING CODE CONVENTIONAL FRAMING REQUIREMENTS AND OF INDUSTRY ACCEPTED STANDARD GOOD PRACTICE. AS NOT EVERY CONDITION OR FRAMING ELEMENT IS (OR CAN BE) EXPLICITLY SHOWN ON THESE DRAWINGS, IT IS UNDERSTOOD THAT THE CONTRACTOR WILL USE INDUSTRY ACCEPTED STANDARD GOOD PRACTICE FOR ALL MISCELLANEOUS WORK NOT EXPLICITLY SHOWN. 3.THESE DRAWINGS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED CONSTRUCTION SUCH THAT DESIGN LIVE LOAD PER SQUARE FOOT AS STATED HEREIN IS NOT EXCEEDED. OPTIONS ARE FOR CONTRACTOR'S CONVENIENCE. IF AN OPTION IS USED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL NECESSARY CHANGES, AND SHALL COORDINATE ALL DETAILS. 4.WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND SPECIFICATIONS, THE GREATER REQUIREMENTS SHALL GOVERN. TYPICAL DETAILS AND NOTES ARE NOT NECESSARILY INDICATED ON THE PLANS, BUT SHALL APPLY NONE-THE-LESS. WHERE NO DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE PROJECT. DETAILS MAY SHOW ONLY ONE SIDE OF CONNECTION OR MAY OMIT INFORMATION FOR CLARITY. 5.ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, PLUMBING AND ELECTRICAL WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS PRIOR TO START OF CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT AND STRUCTURAL ENGINEER. 6.ANY INSPECTIONS, SPECIAL (IBC CHAPTER 17) OR OTHERWISE THAT ARE REQUIRED BY THE BUILDING CODES, LOCAL BUILDING DEPARTMENTS, OR BY THESE PLANS SHALL BE DONE BY AN INDEPENDENT INSPECTION COMPANY OR THE BUILDING DEPARTMENT, SITE VISITS BY THE STRUCTURAL ENGINEER DO NOT CONSTITUTE AN OFFICIAL INSPECTION, UNLESS SPECIFICALLY CONTRACTED FOR. 7.SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS IN ADDITION TO ITEMS REQUIRED BY ARCHITECTURAL SPECIFICATIONS, THE CONTRACTOR SHALL REVIEW ALL SHOP DRAWINGS PRIOR TO SUBMITTAL. ITEMS NOT IN ACCORDANCE WITH CONTRACT DRAWINGS SHALL BE FLAGGED UPON HIS REVIEW. VERIFY ALL DIMENSIONS WITH ARCHITECT. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM ORIGINAL CONTRACT DRAWINGS SHALL BE CLOUDED. ANY OF THE AFOREMENTIONED WHICH ARE NOT CLOUDED OR FLAGGED BY SUBMITTING PARTIES, SHALL NOT BE CONSIDERED APPROVED AFTER THE STRUCTURAL ENGINEER'S REVIEW, UNLESS NOTED ACCORDINGLY. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW, SHALL BEAR THE SEAL OF A STRUCTURAL ENGINEER REGISTERED IN THE APPROPRIATE STATE. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. ITEMS OMITTED OR SHOWN INCORRECTLY AND ARE NOT FLAGGED BY THE STRUCTURAL ENGINEER ARE NOT TO BE CONSIDERED CHANGES TO ORIGINAL DRAWINGS. THE ADEQUACY OF ENGINEERING DESIGNS AND LAYOUT PERFORMED BY THE OTHERS RESTS WITH THE DESIGNING OR SUBMITTING AUTHORITY. REVIEWING IS INTENDED ONLY AS AN AID TO THE CONTRACTOR IN OBTAINING CORRECT SHOP DRAWINGS. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ALLOW (5) WORKING DAYS FOR THE STRUCTURAL ENGINEER'S REVIEW. ONE COPY OF EACH SUBMITTAL WILL BE RETAINED FOR THE STRUCTURAL ENGINEER'S RECORDS. BASIS FOR DESIGN: 1.BUILDING CODE: 2012 EDITION OF THE IBC WITH CITY/COUNTY AMENDMENTS. RISK CATEGORY = II 4. SEISMIC DESIGN PARAMETERS: ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE IMPORTANCE FACTOR Ie = 1.00 SITE CLASS D SEISMIC DESIGN CATEGORY D MAPPED SPECTRAL RESPONSE ACCELERATIONS S1 = 0.155, SS = 0.439 DESIGN SPECTRAL RESPONSE ACCELERATIONS SD1 = 0.225, SDS = 0.424 VERTICAL SHEAR TRANSFER ELEMENTS: PLYWOOD SHEARWALL(S)R = 6.5, CS = 0.065 5. WIND DESIGN PARAMETERS (STRENGTH): ULTIMATE WIND SPEED 115 MPH (3 SECOND GUST) WIND EXPOSURE C IMPORTANCE FACTOR Iw = 1.00 INTERNAL PRESSURE COEFFICIENT -0.18 COMPONENT AND CLADDING PRESSURE 36.4 PSF NET UPLIFT ON ROOF 19.7 PSF 2. VERTICAL LOADS: LOCATION LIVE / SNOW LOAD DEAD LOAD ROOF 35 PSF 14 PSF 3. DEFLECTION LIMITS: ELEMENTS LIVE LOAD TOTAL LOAD ROOF TRUSSES/JOISTS L/360 L/240 BEAMS L/360 L/240 FOUNDATION NOTES: 1.IN LIEU OF A GEOTECHNICAL REPORT: THE FOUNDATION HAS BEEN DESIGNED ACCORDING TO THE RECOMMENDATIONS OF CHAPTER 18 OF THE IBC. 2.THE SOIL DESIGN VALUES LISTED BELOW HAVE BEEN APPROVED BY THE CITY/COUNTY BUILDING DEPARTMENT, CONTINGENT THAT THE SOIL ON THE SITE PREDOMINATELY CONSISTS OF SAND AND/OR GRAVEL. SPECIFIC SOIL CLASSIFICATIONS SHOULD BE ONE OF THE FOLLOWING: SANDY GRAVEL OR GRAVEL(GW OR GP), SAND(SW AND SP), SILTY SAND(SM), CLAYEY SAND(SC), SILTY GRAVEL(GM), OR CLAYEY GRAVEL(GC). THESE SOIL CLASSIFICATIONS CAN BE FOUND IN TABLE 1806.2 OF CHAPTER 18 OF THE IBC. VERIFICATION OF SOIL CLASSIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR. 3.A ONE-THIRD INCREASE IN BEARING PRESSURES IS ALLOWED WITH SEISMIC OR WIND LOAD COMBINATIONS. LATERAL BEARING AND LATERAL SLIDING RESISTANCE MAY BE COMBINED. 4.ALL FOUNDATIONS SHALL BEAR ON COMPACTED ENGINEERED FILL. GRADE IS DEFINED AS LOWEST ADJACENT GRADE WITHIN 5 FEET OF THE BUILDING FOR PERIMETER FOOTINGS. WHERE EXTERIOR PAVING OR CONCRETE IS DIRECTLY ADJACENT TO BUILDING, GRADE IS DEFINED AS TOP OF EXTERIOR PAVING AT LEAST 5 FEET FROM BUILDING. CONCRETE FOOTING EXCAVATIONS SHALL BE CLEAN AND FREE OF LOOSE DEBRIS OR UN-COMPACTED MATERIAL AT TIME OF CONCRETE PLACEMENT. 5.CONCRETE SLABS ON GRADE SHALL BE SUPPORTED ON A 4 INCH LAYER OF SELECT FILL MATERIAL OR ACCORDING TO THE SPECIFICATIONS OF THE SOIL REPORT. FILL MATERIAL SHOULD BE MOISTENED, BUT NOT SATURATED JUST PRIOR TO PLACING CONCRETE. 6.BACKFILL AGAINST RESTRAINED WALLS SHALL NOT BE PLACED UNTIL AFTER THE WALLS ARE SUPPORTED BY THE COMPLETION OF INTERIOR FLOOR SYSTEMS AND CONCRETE OR GROUT STRENGTH HAS REACHED THE 28 DAY STRENGTH LISTED BELOW. THE SOIL DESIGN VALUES FOR THE FOUNDATION ARE: ALLOWABLE BEARING PRESSURE 1500 PSF ALLOWABLE LATERAL BEARING PRESSURE 150 PSF/FT ALLOWABLE LATERAL SLIDING COEFFICIENT 0.25 LATERAL BACKFILL PRESSURE (UNRESTRAINED)30 PSF/FT LATERAL BACKFILL PRESSURE (RESTRAINED)50 PSF/FT FOUNDATION BEARING DEPTH 36" BELOW FINISHED GRADE CONCRETE: 2.ALL NORMAL WEIGHT CONCRETE SHALL BE REGULAR WEIGHT OF 150 POUNDS PER CUBIC FOOT USING HARD-ROCK AGGREGATES. AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33. 3.LAP SPLICES FOR BEAMS AND FLOOR SLABS SLABS SHALL BE ACCORDING TO CHAPTER 12 OF ACI 318 OR LAP SCHEDULE ON THESE DRAWINGS. STAGGER SPLICES A MINIMUM OF ONE LAP LENGTH. NO TACK WELDING OF REINFORCING BARS ALLOWED WITHOUT PRIOR REVIEW OF PROCEDURE WITH THE STRUCTURAL ENGINEER. LATEST ACI CODE AND DETAILING MANUAL APPLY. PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT ALL CORNERS AND INTERSECTIONS PER TYPICAL DETAILS. VERTICAL WALL BARS SHALL BE SPLICED AT OR NEAR FLOOR LINES. 4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING STEEL NOT NOTED AS "CLEAR" OR "CLR" ARE TO CENTER OF STEEL. MINIMUM COVER FOR NON-PRESTRESSED CONCRETE REINFORCING SHALL BE AS FOLLOWS: 5.MAXIMUM SLUMP FOR ALL CONCRETE SHALL BE 4". SLUMP FOR EXTERIOR SLABS SHALL BE 6". PORTLAND CEMENT SHALL CONFORM TO ASTM C150. TYPE V CEMENT SHALL BE USED FOR CONCRETE IN CONTACT WITH ALKALINE SOIL, AND TYPE II ELSEWHERE. 6.NO MORE THAN 90 MINUTES SHALL ELAPSE BETWEEN CONCRETE BATCHING AND CONCRETE PLACEMENT UNLESS APPROVED BY THE TESTING AGENCY. 7.CONCRETE PLACEMENT AND QUALITY SHALL BE PER RECOMMENDATIONS IN ACI 614, ACI 301 AND ACI 318. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED ONLY AROUND AND UNDER FLOOR DUCTS, ETC. CAST CLOSURE POUR, WHERE SHOWN ON PLANS AROUND COLUMNS AFTER COLUMN DEAD LOAD IS APPLIED. REMOVE ALL DEBRIS FROM FORMS BEFORE PLACING CONCRETE. ALL ITEMS TO BE CAST IN CONCRETE SUCH AS REINFORCING, DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY POSITIONED IN THE FORMS BEFORE PLACING THE CONCRETE. 8.ALL CONCRETE SLABS ON GRADE SHALL BE DIVIDED INTO AREAS BY CONTROL JOINTS (KEYED OR SAW CUT) SUCH THAT ONE SLAB AREA DOES NOT EXCEED 250 SQUARE FEET, OR BE MORE THAN TWO TIMES LONGER THAN THE SLAB AREA WIDTH. THE FOUNDATION PLAN SHOWS A SUGGESTED METHOD OF CONTROL JOINT LAYOUT. IT IS RECOMMENDED THAT SAW CUTS BE MADE WITHIN 16 HOURS OF CONCRETE BATCHING. KEYED CONTROL JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING POURING, ALL OTHER JOINTS MAY BE SAW CUT. 9.HORIZONTAL PIPES AND ELECTRICAL CONDUITS SHALL NOT BE EMBEDDED IN STRUCTURAL CONCRETE AND SLABS ON GRADE EXCEPT WHERE SPECIFICALLY APPROVED OR NOTED BY THE STRUCTURAL ENGINEER. PIPES AND CONDUITS SHALL NOT IMPAIR THE STRENGTH OF THE WORK. 10.FLY ASH MAY BE USED ONLY IF PERMITTED BY ARCHITECTURAL SPECIFICATIONS AND SHALL BE LIMITED TO 18 PERCENT OF CEMENTITIOUS MATERIALS AND SHALL HAVE A REPLACEMENT FACTOR OF 1.2 RELATIVE TO CEMENT REPLACED. NO FLY ASH ADDITIVES SHALL BE USED IN FLATWORK OR ARCHITECTURALLY EXPOSED CONCRETE. 11.COLD/HOT WEATHER CONCRETE CONSTRUCTION: PROTECT CONCRETE FROM DAMAGE OR REDUCED STRENGTH IN COMPLIANCE WITH ACI 305 AND 306. 12.CONCRETE MIXES SHALL BE DESIGNED BY A CERTIFIED LABORATORY AND APPROVED BY THE STRUCTURAL ENGINEER. LOCATION:MINIMUM COVER TOLERANCE CAST AGAINST EARTH (FOOTINGS)3"± 3 8" SLABS ON GRADE 112"± 14" EXPOSED TO EARTH OR WEATHER - #5 AND SMALLER 112"± 3 8" EXPOSED TO EARTH OR WEATHER - #6 AND LARGER 2"± 3 8" NOT EXPOSED TO WEATHER OR IN CONTACT WITH THE GROUND ROOF SLAB 1"18" STRUCTURAL SLABS AND WALLS 3 4"18" BEAMS AND COLUMNS (PRIMARY) REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 112"3 8" 1. MINIMUM 28 DAY CONCRETE STRENGTH SHALL BE AS FOLLOWS: USE:CONCRETE STRENGTH: MAX W/C RATIO AIR ENTRAINMENT FOUNDATIONS 4500 PSI 0.45 5.5% ± 1% CONCRETE SLABS ON GRADE 3500 PSI 0.45 N/A REINFORCING STEEL: 1.ASTM A615 GRADE 60 (FY = 60 KSI) DEFORMED BARS FOR ALL BARS #4 AND LARGER. ASTM A615 GRADE 40 (FY = 40 KSI) DEFORMED BARS FOR ALL BARS #3 AND SMALLER. GRADE 60 DEFORMED BARS SHALL BE USED FOR CONCRETE WALLS, BEAMS, ELEVATED SLABS AND COLUMN REINFORCING. 2.WELDING OF REINFORCING BARS SHALL BE MADE ONLY TO ASTM A706 GRADE 60 BARS AND ONLY USING E90 SERIES RODS. WELDING OF REINFORCING BARS SHALL BE MADE ONLY AT LOCATIONS SHOWN ON PLANS OR DETAILS. 3.REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO FOUNDATION. SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE. WOOD: 1.GENERAL: DO NOT NOTCH OR DRILL JOISTS, BEAMS, OR LOAD BEARING STUDS WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. DOUBLE UP JOISTS AND BLOCKING UNDER PARTITIONS. PROVIDE 2" (NOMINAL) SOLID BLOCKING AT SUPPORTS OF ALL JOISTS. UNLESS NOTED OTHERWISE ON PLANS/DETAILS PROVIDE 2x SOLID BLOCKING AT MID-HEIGHT OF BEARING STUD WALLS. ALL NAILING NOT NOTED SHALL BE ACCORDING TO IBC TABLE 2304.9.1. JOIST HANGERS AND OTHER MISC. FRAMING ANCHORS SHALL BE SIMPSON STRONG-TIE COMPANY, INC. OR OTHER MANUFACTURER WITH CURRENT ICC-ES APPROVAL. 2.SAWN LUMBER: FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (WWPA) OR THE WEST COAST LUMBER INSPECTION BUREAU (WCLIB). ALL SAWN LUMBER SHALL BE STAMPED WITH THE GRADE MARK OF AN APPROVED LUMBER GRADING AGENCY. SAWN LUMBER SHALL HAVE THE FOLLOWING MINIMUM GRADE UNLESS NOTED OTHERWISE IN SCHEDULES: USE:MATERIAL: 2X4 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) 2X6 STUDS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) JOISTS, TOP PLATES AND ALL OTHER SAWN LUMBER DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) BEAMS AND POSTS DOUGLAS-FIR NO. 2, MINIMUM (U.N.O.) LOCATION:NOMINAL THICKNESS: SPAN INDEX RATING: EDGE ATTACHMENT: FIELD ATTACHMENT: WALL 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 7 16" OR 12"24 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 15 32" OR 12"32 16 8d AT 6" O.C.8d AT 12" O.C. ROOF 19 32" OR 5 8"40 20 10d AT 6" O.C.10d AT 12" O.C. ROOF 23 32" OR 3 4"48 24 10d AT 6" O.C.10d AT 12" O.C. ROOF 7 8"60 32 10d AT 6" O.C.10d AT 12" O.C. FLOOR 3 4" T&G 48 24 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 7 8" T&G 60 32 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. FLOOR 118" T&G 60 48 10d AT 6" O.C. OR #8 SCREWS AT 6" O.C. 10d AT 6" O.C. OR #8 SCREWS AT 12" O.C. 3.PLYWOOD: ALL PLYWOOD SHALL BE C-D OR C-C SHEATHING CONFORMING TO STANDARD PS 1-95. LAY UP PLYWOOD WITH FACE GRAIN IN PERPENDICULAR TO SUPPORTS (ON ROOFS WHERE PLYWOOD IS LAID UP WITH FACE GRAIN PARALLEL TO SUPPORTS, USE A MINIMUM OF 5-PLY PLYWOOD, STAGGER JOINTS). ALL NAILING, COMMON NAILS. BLOCKING AT PANEL EDGES WHERE INDICATED ON PLANS. ALL PLYWOOD SHALL BE OF THE FOLLOWING NOMINAL THICKNESS, SPAN/INDEX RATING AND SHALL BE NAILED AS FOLLOWS UNLESS NOTED OTHERWISE ON THE PLANS: SCREWS AT FLOOR SHEATHING SHALL BE #8 SCREWS AND SHALL PENETRATE AT LEAST 112" INTO THE SUPPORTING MEMBER. ALL FLOOR SHEATHING SHALL BE GLUED TO SUPPORTING MEMBERS WITH AN APA AFG-01 QUALIFIED GLUE. PLYWOOD ALTERNATE: AMERICAN PLYWOOD ASSOCIATION PERFORMANCE RATED SHEATHING MAY BE USED AS AN ALTERNATE TO PLYWOOD WITH PRIOR APPROVAL OF OWNER, ARCHITECT AND ROOFER. IT MAY NOT BE USED ON ROOFS WHERE BUILT-UP ROOF SYSTEM IS TO BE GUARANTEED BY ROOFER. RATED SHEATHING SHALL COMPLY WITH CURRENT ICC-ES REPORTS AND SHALL HAVE A SPAN RATING EQUIVALENT TO OR BETTER THAN THE PLYWOOD IT REPLACES. ATTACHMENT AND THICKNESS (WITHIN 132") SHALL BE THE SAME AS THE PLYWOOD IT REPLACES. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 4.NOMINAL 2x AND 3x DECKING. TONGUE AND GROOVE TYPE. MINIMUM Fb = 1,600 PSI, MINIMUM E = 1,300,000 PSI. INSTALL WITH TONGUES UP SLOPE ON PITCHED ROOFS, AND OUTWARD IN THE DIRECTION OF LAYING ON FLAT ROOFS. NAIL EACH PLANK WITH 16d TOENAIL (THRU THE TONGUE) AND 16d FACE NAIL AT EACH SUPPORT. DECK SHALL BE INSTALLED AS SIMPLE SPAN WITH ALL PLANKS BEARING ON TWO SUPPORTS. FOR REFERENCE AND/OR ADDITIONAL INFORMATION SEE AITC 117-2010. 5.GLUED-LAMINATED BEAMS (GL): GLUED-LAMINATED BEAMS SHALL BE DOUGLAS FIR COMBINATION AT 24F-V4 AT SIMPLE SPAN BEAMS AND 24F-V8 AT MULTI-SPAN AND CANTILEVERED BEAMS WITH THE FOLLOWING MINIMUM PROPERTIES: FB = 2,400 PSI, FV = 190 PSI, FC (PERPENDICULAR) = 650 PSI, E =1,800 KSI. ALL BEAMS SHALL BE FABRICATED USING WATERPROOF GLUE. FABRICATION AND HANDLING PER LATEST AITC AND WCLA STANDARDS. BEAMS TO BEAR GRADE STAMP AND AITC STAMP AND CERTIFICATE. CAMBER AS SHOWN ON DRAWINGS. STANDARD CAMBER IS BASED ON A RADIUS OF CURVATURE OF 2000 FEET. 6.LAMINATED VENEER LUMBER (LVL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LVLs SHALL BE: FB = 2,600 PSI, FV = 285 PSI, E = 2,000 KSI. 7.PARALLEL STRAND LUMBER (PSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR PSLs SHALL BE: FB = 2,900 PSI, FV = 290 PSI, E = 2,000 KSI. 8.LAMINATED STRAND LUMBER (LSL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST ICC-ES REPORT. MINIMUM PROPERTIES FOR LSLs SHALL BE: FB = 2,325 PSI, FV = 310 PSI, E = 1,550 KSI. 9.SILL PLATES RESTING ON CONCRETE OR MASONRY SHALL BE OF TREATED FIR. SHEAR WALLS AND EXTERIOR WALL SILLS AT CONCRETE SLAB SHALL HAVE A MINIMUM OF (2) ANCHOR BOLTS PER PIECE. PROVIDE ANCHOR BOLT AT 9" MAXIMUM, 4" MINIMUM FROM THE END OF EACH PIECE AT SPLICE OR END OF WALL. MAXIMUM ANCHOR BOLT SPACING SHALL BE 72" ON CENTER UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. ALL ANCHOR BOLTS (OTHER THAN BOLTS FOR HOLDOWNS) SHALL EMBED 7" INTO CONCRETE. ANCHOR BOLTS FOR HOLDOWNS SHALL NOT BE CONSIDERED AS PART OF REQUIRED ANCHOR BOLTS ON SHEAR WALLS. ALL EXTERIOR WALLS SHALL BE SECURED WITH MINIMUM ANCHOR BOLTS. INTERIOR WALLS MAY BE SECURED TO CONCRETE WITH EITHER ANCHOR BOLTS OR POWER DRIVEN SHOT PINS UNLESS NOTED OTHERWISE ON PLANS. 10.BOLTING: ALL BOLTS IN WOOD CONNECTIONS SHALL CONFORM TO ASTM A307. BOLTS SHALL BE INSTALLED IN HOLES BORED WITH A BIT 116" LARGER THAN THE Ø (DIAMETER) OF THE BOLT. BOLTS AND NUTS SEATING ON WOOD SHALL HAVE CUT STEEL WASHERS UNDER HEADS AND NUTS. NICK THREADS TO PREVENT LOOSENING. 11.PREFABRICATED WOOD TRUSSES: PREFABRICATED WOOD TRUSSES SHALL BE DESIGNED TO SUPPORT SELF WEIGHT PLUS LIVE LOAD AND SUPERIMPOSED DEAD LOADS. WHERE ATTIC SPACE CAN BE USED FOR STORAGE, A 40 PSF LIVE LOAD ON THE BOTTOM CHORD SHALL BE INCLUDED IN THE ANALYSIS. BRIDGING SIZE AND SPACING BY TRUSS MANUFACTURER UNLESS NOTED OTHERWISE. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED ENGINEER FOR REVIEW PRIOR TO MANUFACTURE FOR BOTH ROOF AND FLOOR TRUSSES WHEN USED. SHOP DRAWINGS SHALL SHOW ANY SPECIAL DETAILS REQUIRED AT BEARING POINTS. ALL CONNECTORS SHALL HAVE CURRENT ICC-ES APPROVAL. ADDITIONAL TRUSSES SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. PER IBC SECTION 2303.4 AND TPI-1: EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED THERETO THE IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS, THE DESIGN LOADS, AND THE TRUSS SPACING - WITHIN TWO FEET OF THE CENTER OF THE SPAN ON THE FACE OF THE BOTTOM CHORD. PREFABRICATED WOOD/STEEL WEB JOIST/PURLINS (TJI/TJL SERIES OR EQUAL): DESIGN, FABRICATION AND ERECTION IN ACCORDANCE WITH THE LATEST EDITION ICC-ES REPORT. CONNECTIONS AND BEARING MATERIAL TO BE DESIGNED AND FURNISHED BY JOIST FABRICATOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH DESIGN CALCULATIONS SEALED BY A REGISTERED STRUCTURAL ENGINEER FOR REVIEW PRIOR TO MANUFACTURE. ADDITIONAL JOISTS SHALL BE SUPPLIED AS REQUIRED TO SUPPORT MECHANICAL EQUIPMENT. DEFERRED SUBMITTAL ITEMS: PREFABRICATED WOOD ROOF TRUSSES SHEET INDEX SHEET DESCRIPTION DETAILS S1.0 GENERAL STRUCTURAL NOTES --- S1.1 TYPICAL DETAILS T-SERIES S1.2 TYPICAL DETAILS T-SERIES S2.0 FOUNDATION PLAN --- S2.1 ROOF FRAMING PLAN --- S3.0 FRAMING DETAILS 100 - SERIES CAST IN PLACE CENTERLINE CENTERLINE OF BEAM CENTERLINE OF COLUMN CENTERLINE OF WALL CLEAR CONCRETE CONCRETE CONTROL JOINT CONCRETE SAWCUT JOINT CONCRETE MASONRY UNIT CONNECTION CONTINUOUS DEAD LOAD DOWN DRAWING(S) EQUAL EQUIPMENT EXPANSION JOINT EACH WAY FINISHED FLOOR FACE OF STEEL FACE OF WALL GAUGE GALVANIZED GENERAL STRUCTURAL NOTES CENTERLINE OF FOOTING FACE OF MEMBER EXPANSION BOLT EDGE OF SLAB DIAMETER GALV. GSN DN. DWG(S) EQ. EQUIP. EXP. JT (E.J.) E.W. F.F. F.O.S. F.O.W. GA. F.O.M. EXP. BOLT E.O.S. o OR DIA. C.I.P. C.L. C.L.B. C.L.C. C.L.W. CLR CONC C.C.J. C.S.J. C.M.U. CONN. CONT. D.L. C.L.F. W/WITH W/O WITHOUT T.O.P. U.N.O. W.W.F. TYP. VERT T.O.S. T.O.W. T.O.D. T.O.F. T.O.L. T.O.M. STD T.O.B. T.L. SLH SLV SIM. SQ. PSF PSI REINF. PREFAB OPP. P.C. PLF N.T.S. O.C. O.F.W. TOP OF FOOTING UNLESS NOTED OTHERWISE WELDED WIRE FABRIC TOP OF MASONRY TOP OF PLATE TOP OF STEEL TOP OF WALL TYPICAL VERTICAL STANDARD TOP OF BEAM TOP OF DECK TOP OF LEDGER TOTAL LOAD OUTSIDE FACE OF WALL PRECAST CONCRETE POUNDS PER LINEAR FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH SHORT LEG VERTICAL SHORT LEG HORIZONTAL REINFORCING SIMILAR SQUARE NOT TO SCALE ON CENTER OPPOSITE PREFABRICATED AGGREGATE BASE COURSE AIR CONDITIONER ABOVE FINISHED FLOOR ALTERNATE ANCHOR BOLT AT (MEASUREMENT) BEAM BOTTOM OF BEAM BOTTOM OF DECK BEARING BELOW FINISHED FLOOR BOTTOM OF FOOTING A.B.C. A/C A.F.F. ALT. A.B. @ BM B.O.B. B.O.D. BRG B.F.F B.O.F. ABBREVIATIONS LBS (#) MFR('S) M.C.J. MECH'L. N/A LLV LLH HORIZ. K(KIP) GLB (GLULAM) I.F.W. L.L. LONG LEG VERTICAL MANUFACTURER('S) MASONRY CONTROL JOINT NOT APPLICABLE LONG LEG HORIZONTAL GLUED-LAMINATED BEAM INSIDE FACE OF WALL POUNDS MECHANICAL HORIZONTAL 1000 POUNDS LIVE LOAD EXISTING(E) MIN.MINIMUM MAX.MAXIMUM KEYNOTES: 1.FINISHED GRADE WHERE OCCURS 2.DO NOT EXCAVATE A TRENCH CLOSER THAN A 45 DEGREE ANGLE TO BELOW BOTTOM FOOTING OR FOUNDATION 3.BOTTOM OF CONCRETE FOOTING 4.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPE OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 1 1 2 3 4 FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T1 TRENCH PARALLEL TO CONTINUOUS STRAP FOOTING TD01 NO SCALE KEYNOTES: 1.CONCRETE FOOTING 2.SLEEVE - PROVIDE 12" MINIMUM CLEARANCE AROUND PIPE OR CONDUIT 3.PIPE OR CONDUIT 4.CONCRETE FILL TO BE PLACED BEFORE FOOTING IS POURED - FORM SAME AS FOOTING AND POUR FULL WIDTH OF PIPE TRENCH 5.STEM WALL NOTE: A.NO PIPE SHALL PASS THRU FOOTING OR UNDER COLUMN FOOTINGS. FOR TRENCHES GREATER THAN 3'-6" BELOW BOTTOM OF FOOTING, SEE PIPE PASSING BELOW WALL FOOTING DETAIL. 1 2 3 4 5 5 4 2 1 3 T2 PIPE PASSING UNDER WALL FOOTING IN SHALLOW TRENCH TD02 NO SCALE 6" M I N 8" M I N 3' - 0 " M A X 8" MIN A SECTIONA KEYNOTES: 1.STEM WALL 2.CONCRETE FOOTING 3.1'-6" MAXIMUM - WHERE TRENCH EXCEEDS 1'-6" NOTIFY STRUCTURAL ENGINEER PRIOR TO PLACEMENT OF FOOTINGS 4.BACKFILL AND RECOMPACT TRENCH PER SOILS REPORT AND SPECIFICATIONS 5.BOTTOM OF TRENCH NOTE: A.DO NOT UNDERCUT EXISTING FOOTINGS B.NO PIPES OR OTHER UTILITIES SHALL PASS THRU WALL FOOTINGS OR UNDER COLUMN FOOTINGS 1 5 4 3 2 3' - 1 " O R G R E A T E R FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. T3 PIPE PASSING BELOW FOOTING IN DEEP TRENCH TD03 NO SCALE KEYNOTES: 1.SLOPED FINISH GRADE 2.MINIMUM FOOTING DEPTH PER G.S.N. - 12" MINIMUM 3.DEEPEN FOOTING AS REQUIRED TO ACCOUNT FOR SLOPED GRADE 4.CONCRETE FOOTING NOTE: A.FOR ADDITIONAL INFORMATION, SEE PLANS AND DETAILS 1 4 3 2 5'-0" T4 TYPICAL DETAIL FOR FOUNDATION EMBEDMENT TD04 NO SCALE KEYNOTES: 1.CORNER DOWELS TO MATCH HORIZONTAL REINFORCEMENT 2.CONCRETE WALL WITH REINFORCEMENT 18" MIN LAP SPLICE (TYP) T5 TYPICAL CONCRETE CORNER TD05 NO SCALE 2 1 KEYNOTES: 1.CONCRETE SLAB ON GRADE 2.CONT KEYED JOINT 3.SAWCUT 18" WIDE x 14" SLAB THICKNESS IN DEPTH - CUT SHALL BE MADE SOON ENOUGH TO PREVENT SHRINKAGE CRACKING, BUT NOT SO SOON AS TO CAUSE SPALLING OF THE CONCRETE WHILE SAWING. WORK MUST BE COMPLETE WITHIN 16 HOURS OF CONCRETE PLACEMENT. NOTE: A.KEYED JOINTS NEED ONLY OCCUR AT EXPOSED EDGES DURING PLACEMENT UNLESS SPECIFICALLY NOTED ON THE PLANS. B."TOOL WET JOINT", "ZIP STRIP", ETC SHALL MATCH SAWCUT REQUIREMENTS 1 2 3 1 12"6"6"12" X SAWCUT JOINT X KEYED JOINT T7 CONTROL JOINTS IN CONCRETE SLAB ON GRADE TD07 NO SCALE 6 MIN BAR OFFSET BAR CLEARANCE SPLICE DETAIL BEND & HOOK DETAILS COLUMN TIES BEAM STIRRUPS "d" 45° "d" "d" 1 2 4 5 6 10 9 8 7 3 1 5 5 9 10 8 KEYNOTES: 1.LAP - SEE G.S.N. 2.MAXIMUM 15 LAP BUT NOT MORE THAN 6" 3.WIRE TIES 4.1d (1" MINIMUM) 5.RADIUS = 3d FOR BARS NOT OVER #8; 4d FOR #9, #10, AND #1 BARS; 5d FOR #14 AND #18 BARS, 5d FOR ALL GRADE 40 BARS WITH 180 DEGREE HOOK 6.4D (4" MINIMUM) 7.12d (90 DEGREE HOOK) 8.6d (4" MINIMUM) 9.135 DEGREE BEND 10.BEND AROUND 112" PIN FOR #3 BARS. BEND AROUND 2" PIN FOR #4 BARS. BEND AROUND 212" PIN FOR #5 BARS. T10 TYPICAL REINFORCING DETAILS TD10 NO SCALE KEYNOTES: 1.CONCRETE FOOTING, SEE PLAN 2.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3.#4 DOWEL TO MATCH FOOTING REINFORCEMENT 4.#4 DOWEL TO LAP AND MATCH WALL REINFORCEMENT NOTE: A.FOR ITEMS SHOWN BUT NOT KEYNOTED, SEE FOUNDATION DETAILS B.WHERE NEW FOOTING TIES INTO EXISTING FOOTING, DRILL AND EPOXY 24" LONG DOWELS INTO EXISTING, PROVIDE 4" MIN EMBEDMENT 2 3" CLR. 3" CL R . 24" 24" 1 3 2 1 4 24" 24" T6 CONCRETE FOOTING AT CONCRETE WALL TD12 NO SCALE NOTES: 1.TOP BARS ARE ANY HORIZONTAL BARS PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. 2.UNLESS NOTED OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, SLABS AND WALLS SHALL BE CLASS "B" TENSION LAP SPLICES. BAR SIZE CLASS B TENSION SPLICE LENGTHS f'c = 3,000 PSI f'c = 4,000 PSI f'c = 5,000 PSI HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS HOIRZONTAL BARS W/ >12" OF CONC. BELOW VERTICAL AND BOTTOM HORIZONTAL BARS #3 12"12"12"12"12"12" #4 19"15"17"13"15"12" #5 29"23"26"20"23"18" #6 32"25"28"21"25"19" #7 54"41"47"36"42"32" #8 70"54"61"47"54"42" #9 89"68"77"59"69"53" #10 112"87"97"75"87"67" T8 STEEL REINFORCING LAP SPLICES IN CONCRETE TD14 NO SCALE KEYNOTES: 1.SHEATHING MATERIAL. 2.DOUBLE STUDS AT EACH END OF SHEARWALL. EDGE NAIL ALONG DOUBLE STUDS. 3.FULL HEIGHT WOOD STUDS. 4.BOTTOM PLATE ATTACHMENT. 5.SIMPSON STHD TYPE HOLDOWN. 6.MIDHEIGHT BLOCKING AND EDGE NAILING REQUIRED. 7.SIMPSON PHD TYPE HOLDOWN. 8.FINISHED FLOOR. 1 3 6 8 7 4 5 2 T13 ELEVATION-TYPICAL 1-STORY SHEARWALL TD19 NO SCALE NOTE: A.CONNECT FRAMING AT OVERBUILD AREAS PER TYPICAL DETAILS B.FRAMING NOT BEARING ON SUPPORT SHALL BE HUNG USING SIMPSON LU, U, LUP OR LSSU TYPE HANGERS DESIGNATED FOR THE JOIST SIZE AT SPANS LESS THAN 10'-0" SIMPSON A34 OR (4)-16d NAILS MAY BE USED, AT SPANS LESS THAN 5'-6", (3)-16d NAILS MAY BE USED 2x6 2x8 2x10 SIMPLE ROOF FRAMING OR ROOF OVERBUILD FRAMING 9'-6" 8'-0" 3'-6" 2x8 2x6 2x4 MAXIMUM HORIZONTAL SPAN JOIST FRAMING RIDGE/VALLEY/HIP SIMPLE CEILING FRAMING HORIZONTAL SPAN 7'-0" 10'-0" 6'-0" MAXIMUM 2x6 2x8 2x4 CEILING JOIST T14 TYPICAL JOIST SCHEDULE FOR SIMPLE FRAMING TD20 NO SCALE KEYNOTES: 1.PREFAB WOOD ROOF TRUSS, GIRDER TRUSS, OR HIP TRUSS 2.WOOD ROOF JOISTS OR RAFTER 3.CONNECTION WITH NAILS OR SIMPSON HANGER (SIMPSON LU, U, LUP, OR LSS) TYPE HANGER DESIGNED FOR THE JOIST SIZE. USE SKEWED MODEL AS REQUIRED JOIST CONNECTION 2x4 2x6 2x8 LARGER 2x10 OR SIMPSON A34 SIMPSON HANGER OR 3-16d NAILS OR 4-16d NAILS OR SIMPSON HANGER OR SIMPSON A34 2 - 16d NAILS SIMPSON HANGER OR SIMPSON A35 AND SIMPSON HANGER T15 TYPICAL SIMPLE FRAMING AT WOOD TRUSS TD21 NO SCALE 3 2 1 3 2 1 -TYPICAL BOLT HEAD HOOK OR STANDARD 2" MIN. BOLT SIZE 1/2"Ø 7"4" 5"8"5/8"Ø 6"9"3/4"Ø 7"10"7/8"Ø 8"11"1"Ø ANCHOR BOLT EXPANSION ANCHOR FACE OF WALL, TOP OF WALL, COLUMN, ETC.ANCHOR OR BOLT DIAMETERS SPECIFIED IN DETAILS OR ON PLANS SHALL MEET THESE MINIMUM REQUIREMENTS FOR EMBEDMENT. THICKNESS OF DRYPACK DOES NOT APPLY TOWARDS EMBEDMENT. SIMPSON STRONG BOLT 2 (ESR-3037) HILTI ANCHORS KWIK-BOLT TZ (ESR-1917). POWERS POWER-STUD (ESR-2502) EXPANSION ANCHOR APPROVALS: CAST IN PLACE VERTICAL HORIZONTAL 4" 5" 6" 7" 9" EXPANSION ANCHOR VERTICAL HORIZONTALHORIZONTAL 2" 2.5" 3" 3.5" 4" EMBEDMENT(MINIMUM)EMBEDMENT(MINIMUM) 3/8"Ø 5"4"3"1.5" 1/4"Ø 4"4"2"1.125" KEY NOTES: T9 TYPICAL ANCHOR BOLT, AND EXPANSION BOLT SCHEDULE TD09 NO SCALE EM B E D M E N T EM B E D M E N T KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.PLYWOOD SHEATHING SHALL BE CONT THRU WALL INTERSECTIONS, GYPSUM SHEATHING MAY BE DISCONTINUOUS 3.16d FACENAIL AT 16" O.C. 4.EDGE NAILING 5.FULL HEIGHT STUD 6.(3)-2x BLOCKS 18" LONG 7.(2)-16d FACENAILS EACH SIDE OF EACH BLOCK 8.PLYWOOD OR GYPSUM 9.INTERSECTING WALL 2 33 4 4 INTERSECTING WALLS GYPSUM SHEARWALLS 2 INTERSECTING WALLS PLYWOOD SHEARWALLS 6 5 8 9 9 8 T12 PLAN VIEW - SHEARWALL INTERSECTIONS TD33 NO SCALE CONNECTION TYPE JOIST OR TRUSS BEARING ON SILL OR GIRDER BRIDGING TO JOIST SOLE PLATE TO JOIST OR BLOCKING, FACE NAIL TOP PLATE TO STUD DOUBLE STUDS, FACE NAIL DOUBLE TOP PLATES CONTINUOUS HEADER TO STUD CEILING JOISTS, LAPS OVER PARTITIONS CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL RAFTER OR TRUSS TO PLATE BUILT-UP CORNER STUDS TOENAIL (4)-8d COMMON (2 1/2" x 0.131") NAILING (3)-8d COMMON (2 1/2" x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL EACH END(2)-3"x 0.131" NAILS (Gun Nail) (2)-3"x 14 GAUGE STAPLES 16d (3 1/2"x 0.135") AT 16" O.C. FACE NAIL 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES SOLE PLATE TO STUD END NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES FACE NAIL 16d (3 1/2"x 0.135") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 8" O.C. 3"x 0.131" NAILS (Gun Nail) AT 8" O.C. FACE NAIL 16d (3 1/2"x 0.135") AT 16" O.C. 3"x 14 GAUGE STAPLES AT 12" O.C. 3"x 0.131" NAILS (Gun Nail) AT 12" O.C. DOUBLE TOP PLATES - FACE NAIL (8)-16d COMMON (3 1/2"x 0.162") (12)-3"x 0.131" NAILS (Gun Nail) (12)-3"x 14 GAUGE STAPLES LAP SPLICE RIM JOIST TO TOP PLATE 8d (2 1/2"x 0.131") AT 6" O.C. 3"x 14 GAUGE STAPLES AT 6" O.C. 3"x 0.131" NAILS (Gun Nail) AT 6" O.C. BLOCKING BETWEEN JOISTS OR RAFTERS TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES AND TOP PLATE TOENAIL TOP PLATES, LAPS AND INTERSECTIONS FACE NAIL (2)-16d COMMON (3 1/2"x 0.162") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES CONTINUOUS HEADER, TWO PIECES 16d COMMON (3 1/2"x 0.162") FACE NAIL AT 16" O.C. ALONG EDGES CEILING JOISTS TO PLATE TOENAIL (3)-8d COMMON (2 1/2"x 0.131") (5)-3"x 0.131" NAILS (Gun Nail) (5)-3"x 14 GAUGE STAPLES FACE NAIL (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES (3)-16d COMMON (3 1/2"x 0.162) (4)-3"x 0.131" NAILS (Gun Nail) (4)-3"x 14 GAUGE STAPLES FACE NAIL (3)-8d COMMON (2 1/2"x 0.131") (3)-3"x 0.131" NAILS (Gun Nail) (3)-3"x 14 GAUGE STAPLES TOENAIL TOENAIL 16d COM.(3 1/2"x 0.162") AT 24" O.C. 3"x 14 GAUGE STAPLES AT 16" O.C. 3"x 0.131" NAILS (Gun Nail) AT 16" O.C.FACE NAIL (2)-8d COMMON (2 1/2" x 0.131") USE- SIMPSON A35 AT 48" O.C.-NA- SIMPSON A35 AT EVERY OTHER BLOCK -NA- NOTE: A.MINIMUM NAILING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES B.NAILING NOT NOTED ON THESE PLANS OR DETAILS SHALL BE PER I.B.C. TABLE 2304.9.1 T11 MINIMUM NAILING SCHEDULE - UNLESS NOTED OTHERWISE TD34 NO SCALE PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S1.1 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 TY P I C A L D E T A I L S .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . . 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E KEYNOTES: 1.SOLID BLOCKING TO BE TIGHT AGAINST PLYWOOD 2.PREFAB WOOD TRUSS OR WOOD JOIST 3.TOP OF WOOD PLATE OR BEAM AS OCCURS 4.PLYWOOD SHEATHING 5.EDGE NAILING NOTE: A.FOR CONSTRUCTION BELOW BLOCKING, SEE PLAN AND DETAILS. BLOCKING IS CONTINUOUS B.INDIVIDUAL SHEAR BLOCKS MAY BE OMITTED EVERY 5TH BLOCK DEPTH X 2"6" 2.5"8" 10" 12" 3" 3" X X2X X SOLID 2X BLOCKING WITH FIELD CUT VENTILATION VENTILATION OPENINGS TYPICAL SOLID BLOCKING DE P T H TYPICAL SOLID BLOCKING WITH PREFAB VENTILATION X T16 ELEVATION - TYPICAL SOLID 2x BLOCKING TD22 NO SCALE 4 5 2 31 5 4 2 31 5 5 4 2 31 KEYNOTES: 1.EDGE NAILING 2.PREFAB WOOD TRUSS, TRUSS MANUFACTURER SHALL PROVIDE VERTICAL WEB TO MATCH LOCATION OF SHEAR PANEL 3.716" PLYWOOD SHEAR PANEL WITH 8d AT 6" O.C. AT PANEL EDGES AND 8d AT 12" O.C. AT INTERMEDIATE SUPPORTS 4.PLYWOOD SHEATHING AS OCCURS 5.2x4 AT 4-SIDES 6.TOP OF WOOD PLATE OR BEAM AS OCCURS 7.PREFAB BLOCKING PER TRUSS MANUFACTURER, IN-PLANE SHEAR CAPACITY TO BE 200# NOTE: A.FOR CONSTRUCTION BELOW PANEL, SEE PLAN AND DETAILS. BLOCKING IS CONTINUOUS B.INDIVIDUAL SHEAR PANEL BLOCKS MAY BE PENETRATED OR OMITTED FOR PASSAGE OF HVAC DUCTS PLYWOOD SHEAR PANEL ALTERNATE PREFAB BLOCKING T17 ELEVATION - TYPICAL PLYWOOD SHEAR PANEL BLOCKING TD23 NO SCALE 4 11 33 55 2 4 2 11 7 26 KEYNOTES: 1.NAILS BETWEEN SPLICE LOCATION PER SCHEDULE - STAGGERED 2.DBL 2x TOP PLATE 3.WOOD STUD WALL, SEE PLAN 4.SPLICE OVER STUD 5.SIMPSON ST6224 OR MSTC40 STRAP AT LOCATIONS WHERE PLATES CAN NOT BE SPLICED NOTE: A.DO NOT SPLICE TOP PLATES WITHIN 6'-0" OF ENDS OF PLYWOOD SHEARWALLS. THIS DETAIL REQUIRED AT ALL EXTERIOR WALLS AND OVER SHEARWALLS - NOT REQUIRED AT INTERIOR NON-SHEARWALLS. (30) 16d (24) 16dLESS THAN 20' OVER 20' 4'-0" 6'-0" LENGTH OF WALL (BETWEEN CORNERS)SPLICE LENGTH NAILS ALONGSPLICE LENGTH MINIMUM 1 2 4 5 3 23 SPLICE LENGTH PER SCHEDULE T18 ELEVATION - TYPICAL TOP PLATE SPLICE TD24 NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.WOOD HEADER 3.KING STUD(S) PER PLAN 4.(2) 16d NAILS AT 2" O.C. 5.16d NAILS AT 12" O.C. 6.TRIMMER STUD(S) PER PLAN 2 6 3 1 5 4 5 T19 TYPICAL HEADER CONNECTION TD25 NO SCALE KEYNOTES: 1.BOUNDARY NAILING 8d NAILS AT 4" O.C. 2.2x8 (MIN) CONT BEARING PLATE ATTACH PER ATTACHMENT SCHEDULE 3.TOE NAIL OVER-BUILD FRAMING TO BEARING PLATE W/ (3) 16d NAILS MIN 4.ROOF SHEATHING 5.2x OVERBUILD FRAMING, SEE PLAN 6.TOP CHORD OF TRUSS OR ROOF FRAMING MEMBER, SEE PLAN 7.2x STUD PONY WALL AS OCCURS ON PLAN (5'-0" O.C. MAX AND WALL SHALL BE CENTERED BETWEEN MAX SPAN) 8.ROOF SHEATHING (SHEATH LOWER ROOF PRIOR TO CONSTRUCTION OF OVER-BUILD) 9.PREFABRICATED OVERBUILD ROOF TRUSS W/ SIMPSON VTCR CLIP AT 24" O.C. OPTION 2 OPTION 1 6 8 9 4 1 2 542 1 6 3 8 7 4:12 TO 7:12 10:12 TO 12:12 7:12 TO 10:12 < 4:12 (3) 16d NAILS ROOF SLOPE PLATE ATTACHMENT (5) 16d NAILS (3)#10x31 2" LONG SCREWS (4)#10x31 2" LONG SCREWS ATTACHMENT SCHEDULE T20 TYPICAL OVER-BUILD TD27 NO SCALE NOTE: A.MINIMUM STAPLING SPECIFIED HEREIN SHALL BE PROVIDED UNLESS NOTED OTHERWISE ON PLANS, DETAILS OR GENERAL STRUCTURAL NOTES 8d COMMON AT 12" O.C. 16 GA STAPLE AT 12" O.C. ALTERNATE FASTENER SCHEDULE ALTERNATE FASTENERSPECIFIED FASTENER 8d COMMON AT 6" O.C. 8d COMMON AT 4" O.C. 15 GA STAPLE AT 12" O.C. 14 GA STAPLE AT 12" O.C. 13 GA STAPLE AT 12" O.C. 16 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 6" O.C. 13 GA STAPLE AT 5" O.C. 14 GA STAPLE AT 4" O.C. 15 GA STAPLE AT 3" O.C. 16 GA STAPLE AT 2.5" O.C. 15 GA STAPLE AT 2" O.C. 14 GA STAPLE AT 3" O.C. 13 GA STAPLE AT 4" O.C. 8d COMMON AT 3" O.C. MATERIAL: 7/16" SHEARWALL OR ROOF SHEATHING NOTES: 1.STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7 16" INCH OUTSIDE DIMENSION. AND INSTALLED WITH CROWN PARALLEL TO THE LONG DIMENSION OF FRAMING MEMBER. 2.FRAMING SHALL BE 3X OR WIDER WHEN NAIL OR STAPLE SPACING IS LESS THAN 3 INCHES ON CENTER. 3.ALL STAPLES SHALL HAVE 112" LONG LEGS MINIMUM. 4.STAPLE SIZES AND SPACING PER REPORT NO. ICC-ESR-1539 T21 ALTERNATE SHEATHING STAPLE OPTION TD32 NO SCALE PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S1.2 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 TY P I C A L D E T A I L S .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . . 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E 5 5 5 5 5 5 5 55 5 5 5 11"9'-3"1'-2"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"1'-0"9'-3"11" 124'-0" 15 ' - 1 0 " 4' - 3 " 13 ' - 1 " 4' - 3 " 9' - 2 1 2 " 15 ' - 1 0 " 4' - 3 " 13 ' - 1 " 4' - 3 " 9' - 2 1 2 " 41'-8"40'-8"41'-8" 2' - 0 " 2' - 0 " 8' - 4 1 2 " 8' - 4 1 2 " 24'-0" MIN 24'-0" MIN 55 ' - 0 " 4" CONCRETE SLAB ON GRADE OVER COMPACTED FILL. PROVIDE SLAB JOINTS PER TYPICAL DETAIL WITHIN 16 HOURS OF BATCH TIME CONCRETE SLAB ON GRADE WF24/W1 WF24/W1 WF 1 8 / W 1 WF 1 8 / W 1 WF 1 8 / W 1 WF 1 8 / W 1 WF24/W2 WF24/W2 WF24/W2 P2 F36 P2 F36 P2 F30 P2 F36 P2 F30 WF18/W3WF18/W3 WF 1 8 / W 2 WF 1 8 / W 2 4" CONCRETE SLAB ON GRADE W/ #4 AT 36" O.C. EACH WAY CENTERED IN SLAB THICKNESS OVER COMPACTED FILL. CONCRETE SLAB ON GRADE 101 TYP 102101 TYP 102 TYP 102 103 103 103 104 104 101 101 101 TYP 102 TYP 105 TYP 105 103 101 101 4'-111 2"7'-81 4"7'-81 4"7'-81 4"7'-81 4"4'-111 2" PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N CURRENT REV. ST R U C T U R A L E N G I N E E R S S E A L : 2 3 4 5 Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S2.0 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 FO U N D A T I O N P L A N .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . ---- 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E WALL (W) SCHEDULE MARK THICKNESS AND TYPE VERTICAL REINFORCING HORIZONTAL REINFORCING REMARKS W1 8" CONCRETE #4 AT 18" O.C.#4 AT 12" O.C.--- W2 10" CONCRETE #4 AT 16" O.C.#4 AT 10" O.C.--- W3 6" CONCRETE #4 AT 18" O.C.#4 AT 18" O.C.--- FOOTING SCHEDULE NOTES: 1. FOR CONSTRUCTION ABOVE FOOTING, SEE DETAILS. 2. FOR MINIMUM CLEARANCE (CLR) OF REINFORCING, SEE GENERAL STRUCTURAL NOTES (GSN). MARK LENGTH WIDTH THICKN ESS FOOTING REINFORCING REMARKS F30 30"30"10"(3) #4 EACH WAY BOTTOM --- F36 36"36"10"(4) #4 EACH WAY BOTTOM --- WF18 CONT 18"10"(2) #4 CONT BOTTOM WF24 CONT 24"10"(2) #4 CONT BOTTOM STRIP FOOTING STRIP FOOTING POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 4x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS 8.FOR SIDEWALK AND LANDING LOCATIONS, SEE ARCHITECTURAL DRAWINGS. 9.WF18, WF24, ETC. - AS SHOWN ON PLAN INDICATES A CONTINUOUS WALL FOOTING. SEE WALL FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. 10.F36, F48, ETC. - AS SHOWN ON PLAN INDICATES A CONCRETE FOOTING. SEE FOOTING SCHEDULE FOR ADDITIONAL INFORMATION. 11.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. 12.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. 13.VERIFY EXACT SIZE AND LOCATION OF DEPRESSED AND/OR RAISED SLABS WITH ARCHITECTURAL DRAWINGS. FOUNDATION PLAN NOTES 5 6.7 1.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. 2.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. 3.THE DEPTH OF FOOTING DIMENSION INDICATED IN THE G.S.N. IS A MINIMUM. FOUNDATION CONTRACTOR SHALL COORDINATE WITH THE SOILS REPORT AND OTHER TRADES TO INSURE THAT THESE MINIMUMS ARE SUFFICIENT FOR THE WORK. SEE TYPICAL DETAILS FOR ADDITIONAL REQUIREMENTS. 4. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. 5. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. 6. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. 7.W1, W2, ETC. - AS SHOWN ON PLAN INDICATES CONCRETE OR MASONRY WALLS. SEE WALL SCHEDULE FOR ADDITIONAL INFORMATION. SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 SCALE: FOUNDATION PLAN 1/4" = 1'-0" GT 5 5 5 5 5 5 5 55 5 5 5 B2 B2 B2 B2B2 B2 B2 B2 B2 B2 B2 B2 B1 B1 B1 B1 8'-0" MIN 8'-0" MIN 24'-0" MIN 24'-0" MIN 20'-0" MIN 20'-0" MIN 7/16" APA RATED ROOF SHEATHING W/ 8d NAILS AT 6" O.C. AT PANEL EDGES AND BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: PREFAB WOOD TRUSSES AT 24" O.C. OVERBUILT FRAMING PER TYPICAL DETAIL. 7/16" APA RATED ROOF SHEATHING W/ 8d NAILS AT 6" O.C. AT PANEL EDGES AND BOUNDARY AND AT 12" O.C. IN THE FIELD. TYPICAL ROOF SHEATHING: PONY WALL, TYP PONY WALL, TYP P2 P2 (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS (2) TS (1) KS P1 P1 P2P2P2 11 201 201 202 202 202 204 204 202202 202 201201 203 203 PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N CURRENT REV. ST R U C T U R A L E N G I N E E R S S E A L : 2 3 4 5 Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S2.1 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 RO O F F R A M I N G P L A N .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . ---- 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E BEAM (B) SCHEDULE MARK SIZE B1 (2) 2x6 OR 4x6 B2 (3) 13 4x912 LVL 1.NON-BEARING WALL FOR SHEAR PURPOSES ONLY. PLAN KEYNOTESX POST (P) SCHEDULE NOTES: 1. FOR CONNECTIONS AT EITHER END OF POST, SEE DETAILS. 2. UNO, SEE GENERAL STRUCTURAL NOTES (GSN) FOR LUMBER SPECIES AND GRADE. MARK SIZE SPECIES AND GRADE CONNECTION P1 (2) 2x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS P2 4x6 DOUG FIR NO. 2 SEE TYPICAL DETAILS SHEARWALL TYPE SCHEDULE NOTES: 1. SHEARWALL TYPES LISTED BELOW ARE NOT JOB SPECIFIC. SOME TYPES MAY NOT BE USED ON THE PLANS. 2. FRAMING MEMBER SUPPORTING MATERIAL SHALL BE SPACED AT 16" ON CENTER (O.C.) MAXIMUM. 3. ANCHOR BOLTS TO FOUNDATION SHALL BE 10" LONG AND SHALL BE EMBED 7" INTO CONCRETE. EXPANSION BOLTS OR SHOT PINS MAY BE USED AT INTERIOR WALLS (AWAY FROM EDGE OF SLAB OR SLAB STEP-DOWN) PER SUPPLEMENTAL INSTRUCTIONS. 4. A MINIMUM OF (2) ANCHOR BOLTS SHALL BE USED ON EACH BASE PLATE PIECE. PROVIDE (1) ANCHOR BOLT MINIMUM WITHIN 9" OF EACH END PIECE. 5. PROVIDE CONTINUOUS DOUBLE 2x TOP PLATE AT ALL SHEARWALLS AND EXTERIOR WALL. UNLESS NOTED OTHERWISE (U.N.O.), LAP SPLICE TOP PLATE A MINIMUM 4'-0" WITH 16d NAILS STAGGERED AT 2" ON CENTER (O.C.) ((24) 16d NAILS TOTAL BETWEEN SPLICE JOINTS.) 6. PROVIDE FULL HEIGHT DOUBLE STUDS AT ENDS OF SHEARWALLS UNLESS NOTED OTHERWISE ON PLANS OR DETAILS. 7. BLOCK ALL PANEL EDGES. EDGE NAIL SHEATHING AT BLOCKED EDGES. MARK SHEATHING MATERIAL EDGE NAILING FIELD NAILING BOTTOM PLATE ATTACHMENT 7 16" APA RATED SHEATHING (BLOCKED) ONE SIDE OF WALL 8d COMMON AT 6" O.C. 8d COMMON AT 12" O.C. CONCRETE: 12"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 36" O.C. CONCRETE: 5 8"Ø A.B. W/ 14"x3"x3" PLATE WASHERS AT 48" O.C. WOOD: 16d STAGGERED AT 6" O.C. 5 ROOF FRAMING PLAN NOTES 1.VERIFY ALL DIMENSIONS WITH ALL ARCHITECTURAL DRAWINGS. 2.ALL SCHEDULED MARK DESIGNATIONS MAY NOT NECESSARILY BE FOUND ON THIS PLAN. SCHEDULES ARE TYPICAL TO THIS PROJECT. 3.IF DOUBLE TOP PLATE IS NOTCHED, STEPPED OR BROKEN, PROVIDE A SIMPSON MSTC40 STRAP AT DISCONTINUITY. 4.TYPICAL BEARING WALL FRAMING SHALL BE 2x6 STUDS AT 16" O.C. UNO. 5.PROVIDE TRIMMER STUDS (TS) AND KING STUDS (KS) AT OPENINGS AS FOLLOWS, U.N.O.: OPENINGS 8'-0" OR LESS, (1) TS & (1) KS, OPENINGS 8'-1" TO 10'-0", (2) TS & (1) KS, 10'-1" TO 12-0", (2) TS & (3) KS. FOR ATTACHMENT, SEE "TYPICAL HEADER CONNECTION" DETAIL. 6. WALLS WITH SOLID LINES DESIGNATED STRUCTURAL (BEARING) WALLS. 7. WALLS WITH DASHED LINES DESIGNATE NON-STRUCTURAL (NON-BEARING) WALLS. 8. , , , -AS SHOWN ON PLAN INDICATES A SHEARWALL; HATCHING IN WALL DESIGNATES SHEARWALL LENGTH. 9.B1, B2, ETC. - AS SHOWN ON PLAN INDICATES A BEAM OR HEADER. SEE BEAM SCHEDULE FOR ADDITIONAL INFORMATION. 5 6.7 10.P1, P2, ETC. AS SHOWN ON PLAN INDICATES A WOOD POST. SEE POST SCHEDULE FOR MORE INFORMATION. 11.TIE EACH ROOF TRUSS AT BEARING LOCATIONS WITH (1) H5 OR (1) H1 CLIP, AND EACH GIRDER TRUSS WITH (2) H5 CLIPS, UNO. 12.PROVIDE BUILT-UP 2X POSTS BELOW EACH GIRDER TRUSS, MATCH GIRDER TRUSS WIDTH, U.N.O. 13.OVERBUILD PONY WALLS (MAX 8'-0" SPACING FOR 2x6 OVERBUILD FRAMING AT 24" O.C. W/ SIMPSON LUS26 HANGER) PER "TYPICAL OVERBUILD" DETAIL. 14.FOR CLARITY, DETAILS MAY SHOW ONLY ONE SIDE OF FRAMING CONDITION. 15.ALL EXTERIOR WALLS SHALL BE CONSTRUCTED WITH TYPE "5" SHEARWALLS, UNO. SCALE: ROOF FRAMING PLAN 1/4" = 1'-0" KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN NOTE: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS 3" CLR. 3" CL R . 8 10 7 9 6 8 1 2 5 4 8" MI N . 3 NO SCALE KEYNOTES: 1.WALL BEYOND, SEE PLAN 2.#4 BENT DOWEL AT 18" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 3" CLR. 3" CL R . 8 7 6 8 5 4 3 1 2 18" 18" NO SCALE KEYNOTES: 1.WOOD POST, SEE PLAN 2.CONT 2x SOLE PLATE W/ 0.145"Ø MIN SHOT PIN AT 32" O.C. 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE FOOTING, SEE PLAN 5.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 3" CLR. 3" CL R . 5 1 2 4 3 NO SCALE KEYNOTES: 1.WOOD TRUSS W/ CLIP, SEE PLAN 2.CONT DBL 2X TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING AS OCCURS, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.ROOF SHEATHING, SEE PLAN 7.FULL HEIGHT 2x BLOCKING W/ A35 CLIP BETWEEN EVERY THIRD TRUSS 8.BOUNDARY NAILING, SEE PLAN 1 2 3 5 NOTE: A.FASCIA PER ARCHITECTURAL DETAILS B.COORDINATE ROOF VENTILATION 4 6 8 7 NO SCALE KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.2x4x8'-0" LONG AT 6'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 3.WOOD TRUSS W/ HGA10 CLIP AT 36" O.C. 4.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 5.WOOD STUD WALL, SEE PLAN 6.WALL SHEATHING AS OCCURS, SEE PLAN 7.(3) 16d NAILS AT 16" O.C. 8.2x6 LADDER FRAMING AT 16" O.C. 9.BOUNDARY NAILING, SEE PLAN 10.ROOF SHEATHING, SEE PLAN 11.2x6 BLOCKING, FIRST TRUSS BAY MINIMUM 9 1 2 3 4 5 6 7 8 10 7 2'-0" MAX. 99 11 NO SCALE NOTE: A.COORDINATE ROOF VENTILATION B.FASCIA PER ARCHITECTURAL DETAILS 45 1 2 8 6 7 3 1 KEYNOTES: 1.BOUNDARY NAILING, SEE PLAN 2.ROOF SHEATHING, SEE PLAN 3.2x4 AT 4'-0" O.C. W/ (2) 16d NAILS AT EACH TRUSS 4.GIRDER TRUSS, SEE PLAN 5.2x BLOCKING BETWEEN EACH TRUSS W/ (3) 16d NAILS AT EACH BLOCK 6.WOOD TRUSS W/ HANGER, SEE PLAN 7.WOOD TRUSS, SEE PLAN 8.OVERBUILD 2x FRAMING W/ HANGER, SEE PLAN NO SCALE KEYNOTES: 1.WOOD TRUSS, SEE PLAN 2.CONT DBL 2x TOP PLATE W/ LAP SPLICE, SEE TYPICAL DETAIL 3.WOOD STUD WALL, SEE PLAN 4.WALL SHEATHING, SEE PLAN 5.EDGE NAILING, SEE SHEARWALL SCHEDULE 6.FULL-HEIGHT TRUSS BLOCKING W/ A35 CLIP BETWEEN EACH TRUSS 7.BOUNDARY NAILING, SEE PLAN 8.ROOF SHEATHING, SEE PLAN 2 3 4 8 7 51 6 NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.WALL SHEATHING AS OCCURS, SEE PLAN 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 3" CLR. 3" CL R . 8 7 9 6 1 2 5 4 3 NO SCALE KEYNOTES: 1.WOOD STUD WALL, SEE PLAN 2.CONT 2x SOLE PLATE W/ ANCHOR BOLTS PER SHEARWALL SCHEDULE 3.CONCRETE SLAB ON GRADE, SEE PLAN 4.CONCRETE WALL, SEE PLAN 5.CONCRETE FOOTING, SEE PLAN 6.COMPACTED SUB-GRADE BELOW FOOTING, SEE PLAN 7.MINIMUM FOOTING DEPTH, SEE GSN 8.SIDEWALK, PAVEMENT, OR FINISH GRADE PER ARCH 9.EDGE NAILING, SEE SHEARWALL SCHEDULE 10.WALL SHEATHING AS OCCURS, SEE PLAN 11.MASONRY VENEER PER ARCH, ATTACH PER TYPICAL DETAIL NOTE: A.WATERPROOF ANY EXTERIOR WOOD FRAMING WITHIN 8" OF GRADE PER ARCH DRAWINGS 3" CLR. 3" CL R . 8 10 7 9 6 8 1 2 5 4 8" MI N . 3 NO SCALE 3 11 PR O J E C T M A N A G E R : CA D O P E R A T O R : DATE: JO B N O . : ST R U C T U R A L E N G I N E E R S S E A L : PR O J E C T : CL I E N T : RE V . DA T E BY DE S C R I P T I O N 2 3 4 5 CURRENT REV. Th i s d r a w i n g i s t h e p r o p e r t y o f F R O S T S t r u c t u r a l E n g i n e e r i n g , In c . L e g a l l y , t h e d r a w i n g c a n N O T b e c o p i e d i n w h o l e o r i n pi e c e s . I t i s o n l y t o b e u s e d f o r t h e p r o j e c t a n d s i t e s p e c i f i c a l l y id e n t i f i e d h e r e o n a n d i s n o t t o b e u s e d o n a n y o t h e r p r o j e c t . Co n t r a c t o r s h a l l c a r e f u l l y r e v i e w a l l d i m e n s i o n s , d e t a i l s , a n d co n d i t i o n s a n d r e p o r t a t o n c e a n y e r r o r , i n c o n s i s t e n c y o r om i s s i o n d i s c o v e r e d b e f o r e c o n s t r u c t i o n . Th e c o n t r a c t o r a s s u m e s f u l l l i a b i l i t y f o r d e v i a t i o n s f r o m t h e in t e n t o f t h e s e p l a n s . 1 fa x : 2 0 8 . 2 2 7 . 8 4 0 5 10 2 0 E . L i n c o l n R o a d Id a h o F a l l s , I D 8 3 4 0 1 St r u c t u r a l E n g i n e e r i n g ph o n e : 2 0 8 . 2 2 7 . 8 4 0 4 S3.0 11/4/16 AL L E N S T O R A G E BR U C E K A R R E N C O N S T R U C T I O N AJ H EA D IF 1 6 - 1 8 3 FO U N D A T I O N D E T A I L S .RE X B U R G ID A H O . . . . . . . . . . . . . . . . . . . . . . 11 / 4 / 1 6 13 5 6 1 P R O F E S S I O N A L E N G I N E E R L I C E N S E D S T A T E O F I D A H O E R I C C K E R D E