Loading...
HomeMy WebLinkAboutREVIEW BLDG PLAN - 16-00703 - 255 W 2nd N - 4 Plex 1CITY OF REXBURG OW Americo Family Community Residential Building Review on 11/08/2016: Permit Details 255 W 2nd N - 4 Plex 1 255 W 2nd N Final Inspections Required Inspection Details Residential Building Review on 11/08/2016: Inspected By: Ted Dye tedd@rexburg.org Community Development Department 35 North P1 East Rexburg,ID 83440 Permit Technician (208) 372-2341 Inspection Hotline (208) 372-2344 Permit Number: 16-00703 Multi -Family Residential Permit Issued Date: Single Family Residential YES Plans match quantities & values on a "passing" RES check compliance report Provide RES/check REVISIONS Truss Calculation Sheets Truss spec's need to be provided. REVISIONS Flood Plain NO Floor Joist Details APPROVED Gas appliances not in bedrooms, bath., toilet rooms or storage closets G2406.2 APPROVED Room access 36" min width/Attic access clear opening 20x30/Under floor r.o 22x30 M 306.2; 306.3 & 306.4 APPROVED Dyer Vent length 35' max w/8' transition (-5 per 90 deg turns) M504.6.41 APPROVED Appendix F APPROVED 1/2" Anchor bolts with 3" x 3" x 1/4" square washers incl. interior bearin walls R403.1.6.1 APPROVED Foundation Drainage (foundations on sift soil shall be designed per R405 APPROVED Grading slope away from house. R401.3 APPROVED Floor/Foundation Plan APPROVED Section showing construction details APPROVED All Building Elevations APPROVED Design Criteria (identified on plans as Wind -85 mph, Snow -35 lb./sq. R. APPROVED To Scale APPROVED Legible APPROVED Plot Plan By Natalie APPROVED Front set back (32 R, from curb) APPROVED 60% minimum of front yard green APPROVED Page 1 of 3 CITY OF REXBURG Americai Family Community Permit Number: 16-00703 (Continued) Rear set back (LDR1 25 ft. & LDR2 20 ft.) APPROVED Sides set backs (6" for every ft. of building APPROVED height with LDR - 7.5' min. & LDRI - 6' min. Building -Height (max. 30 ft.) APPROVED Proper Size (as per Table 403.1, use 1500 psf APPROVED unless soil type is known, Table 401.4.1 for soil bearing) Rebar (244 continuous) APPROVED Footing Depth (36" below finished grade and 12" APPROVED below undisturbed soil; 18" to top of slab - interior All rebar is tied in place with proper lap? APPROVED Rebar is correct size and spaced as per plans? APPROVED Rebar is a minimum or 1" from forms? APPROVED Seismic Hold Downs and Braced wall Panels APPROVED R602.10 Floors joists sized as per R502.3, Wood I -joists APPROVED sized per manufr. Joists Under Load Bearing Partitions shall be APPROVED doubled. R502.4 Girders sized per R502.5 or per manufr. Tables APPROVED for engineered products Cantilevers (comply with R502.3.3 or manufr APPROVED instruction) Floor Sheathing (3/4" min for joists, 24" oc & 5/8 APPROVED for joists 16") R503.2.2 Wall(bearing and nonbearing)stud sizes, hght & APPROVED spacing er Thl 602.3(5) R602.3 Headers in Bearing Wall designed as per Tables APPROVED 502.5(1&2) R602.7 Roof Trusses (designed according to R802.10.1) APPROVED 35 # Snow and 90 mph winds Local Conditions Rafter and Truss tie -downs R802.10.5 APPROVED Attic Access 22" x 30" min. opening R807 APPROVED 703.9.2.1 APPROVED Roof Ventilation as per R806 APPROVED Asphalt Shingles(slp>2:12) w/ice protection or APPROVED Other type to comply w/R905 Garage/House drywall separation (protect ext. APPROVED walls & beams supporting habitable space) R302.6 Door from Garage to House (13/8" solid wood APPROVED or steel door, or 20 min. fire -rated door) R309.1 Twin homes & townhouses (2 hr sep. & 4' APPROVED overturn protection or parapet) R317.2 1 hr walls parallel to and within 3 ft. of prop. line APPROVED w/ No openings R302 Page 2 of 3 C I TY OF REXBURG Ow America's Family Community Permit Number: 16-00703 (Continued) Penetrations in previous 3 items to comply with APPROVED R317.3 House Numbers R321 APPROVED Interior and exterior stair illumination shall APPROVED comply with R303.6 Bathroom Fixture clearances comply with Figure APPROVED R307.2 *Areas w/ sloped veilings less than 5 ft. in height APPROVED & furred ceilings less than 7 ft DO NOT comply. *50% or more of the required area must be at least 7ft high in rooms w/slo ed ceiling Egress clearance from window wells under APPROVED cantilevered Floors. R310.5 Glazing at Hazardous Locations R308 APPROVED Emergency Egress in all sleeping rooms and APPROVED basements w/ habitable space R310 One required Exit Door shall comply with 2311.2 APPROVED Landings at top and bottom of stairways APPROVED R311.7.5 and each side of each exterior door. R 311.3 Stair width (36' min) APPROVED Stairway Headroom (68") APPROVED Handrails (34' to 38' above stair nosing)R311.7 APPROVED Special conditions for circular, spiral and winder APPROVED stairways and bulkhead enclosures R311.7.9.1 Stairway protection (enclosed accessible space APPROVED under stairs shall be covered with 1/2" drywall) R311.2.2 Guardrails complying with R312 APPROVED Half openable 3sf window or Mech. Ventilation in APPROVED bathrooms, water closets, and similar rooms. R303.3 One room at least 120 sf APPROVED Smoke Alarms (each bedroom and common area APPROVED and 1 on each level) R314 Vapor retarder on warm in winter side of walls, APPROVED ceiling and floors R601.3 *Water Heater heat traps IECC 504.7 APPROVED Duct sealing and insulation N1103.3&4 or IECC APPROVED 503.3.3.3, 503.3.3.4.3 Heating source and Hot water heater locations have not been shown on plans. Page 3 of 3