HomeMy WebLinkAboutREVIEW BLDG PLAN - 16-00703 - 255 W 2nd N - 4 Plex 1CITY OF
REXBURG
OW
Americo Family Community
Residential Building Review on 11/08/2016:
Permit Details
255 W 2nd N - 4 Plex 1
255 W 2nd N
Final Inspections Required
Inspection Details
Residential Building Review on 11/08/2016:
Inspected By: Ted Dye
tedd@rexburg.org
Community Development Department
35 North P1 East
Rexburg,ID 83440
Permit Technician (208) 372-2341
Inspection Hotline (208) 372-2344
Permit Number: 16-00703
Multi -Family Residential
Permit Issued Date:
Single Family Residential
YES
Plans match quantities & values on a "passing"
RES check compliance report
Provide RES/check
REVISIONS
Truss Calculation Sheets
Truss spec's need to be provided.
REVISIONS
Flood Plain
NO
Floor Joist Details
APPROVED
Gas appliances not in bedrooms, bath., toilet
rooms or storage closets G2406.2
APPROVED
Room access 36" min width/Attic access clear
opening 20x30/Under floor r.o 22x30 M 306.2;
306.3 & 306.4
APPROVED
Dyer Vent length 35' max w/8' transition (-5 per
90 deg turns) M504.6.41
APPROVED
Appendix F
APPROVED
1/2" Anchor bolts with 3" x 3" x 1/4" square
washers incl. interior bearin walls R403.1.6.1
APPROVED
Foundation Drainage (foundations on sift soil
shall be designed per R405
APPROVED
Grading slope away from house. R401.3
APPROVED
Floor/Foundation Plan
APPROVED
Section showing construction details
APPROVED
All Building Elevations
APPROVED
Design Criteria (identified on plans as Wind -85
mph, Snow -35 lb./sq. R.
APPROVED
To Scale
APPROVED
Legible
APPROVED
Plot Plan
By Natalie
APPROVED
Front set back (32 R, from curb)
APPROVED
60% minimum of front yard green
APPROVED
Page 1 of 3
CITY OF
REXBURG
Americai Family Community
Permit Number: 16-00703
(Continued)
Rear set back (LDR1 25 ft. & LDR2 20 ft.) APPROVED
Sides set backs (6" for every ft. of building
APPROVED
height with LDR - 7.5' min. & LDRI - 6' min.
Building -Height (max. 30 ft.)
APPROVED
Proper Size (as per Table 403.1, use 1500 psf
APPROVED
unless soil type is known, Table 401.4.1 for soil
bearing)
Rebar (244 continuous)
APPROVED
Footing Depth (36" below finished grade and 12"
APPROVED
below undisturbed soil; 18" to top of slab -
interior
All rebar is tied in place with proper lap?
APPROVED
Rebar is correct size and spaced as per plans?
APPROVED
Rebar is a minimum or 1" from forms?
APPROVED
Seismic Hold Downs and Braced wall Panels
APPROVED
R602.10
Floors joists sized as per R502.3, Wood I -joists
APPROVED
sized per manufr.
Joists Under Load Bearing Partitions shall be
APPROVED
doubled. R502.4
Girders sized per R502.5 or per manufr. Tables
APPROVED
for engineered products
Cantilevers (comply with R502.3.3 or manufr
APPROVED
instruction)
Floor Sheathing (3/4" min for joists, 24" oc & 5/8
APPROVED
for joists 16") R503.2.2
Wall(bearing and nonbearing)stud sizes, hght &
APPROVED
spacing er Thl 602.3(5) R602.3
Headers in Bearing Wall designed as per Tables
APPROVED
502.5(1&2) R602.7
Roof Trusses (designed according to R802.10.1)
APPROVED
35 # Snow and 90 mph winds Local Conditions
Rafter and Truss tie -downs R802.10.5
APPROVED
Attic Access 22" x 30" min. opening R807
APPROVED
703.9.2.1
APPROVED
Roof Ventilation as per R806
APPROVED
Asphalt Shingles(slp>2:12) w/ice protection or
APPROVED
Other type to comply w/R905
Garage/House drywall separation (protect ext.
APPROVED
walls & beams supporting habitable space)
R302.6
Door from Garage to House (13/8" solid wood
APPROVED
or steel door, or 20 min. fire -rated door) R309.1
Twin homes & townhouses (2 hr sep. & 4'
APPROVED
overturn protection or parapet) R317.2
1 hr walls parallel to and within 3 ft. of prop. line APPROVED
w/ No openings R302
Page 2 of 3
C I TY OF
REXBURG
Ow
America's Family Community
Permit Number: 16-00703
(Continued)
Penetrations in previous 3 items to comply with
APPROVED
R317.3
House Numbers R321
APPROVED
Interior and exterior stair illumination shall
APPROVED
comply with R303.6
Bathroom Fixture clearances comply with Figure
APPROVED
R307.2
*Areas w/ sloped veilings less than 5 ft. in height
APPROVED
& furred ceilings less than 7 ft DO NOT comply.
*50% or more of the required area must be at
least 7ft high in rooms w/slo ed ceiling
Egress clearance from window wells under
APPROVED
cantilevered Floors. R310.5
Glazing at Hazardous Locations R308
APPROVED
Emergency Egress in all sleeping rooms and
APPROVED
basements w/ habitable space R310
One required Exit Door shall comply with 2311.2
APPROVED
Landings at top and bottom of stairways
APPROVED
R311.7.5 and each side of each exterior door. R
311.3
Stair width (36' min)
APPROVED
Stairway Headroom (68")
APPROVED
Handrails (34' to 38' above stair nosing)R311.7
APPROVED
Special conditions for circular, spiral and winder
APPROVED
stairways and bulkhead enclosures R311.7.9.1
Stairway protection (enclosed accessible space
APPROVED
under stairs shall be covered with 1/2" drywall)
R311.2.2
Guardrails complying with R312
APPROVED
Half openable 3sf window or Mech. Ventilation in
APPROVED
bathrooms, water closets, and similar rooms.
R303.3
One room at least 120 sf
APPROVED
Smoke Alarms (each bedroom and common area
APPROVED
and 1 on each level) R314
Vapor retarder on warm in winter side of walls,
APPROVED
ceiling and floors R601.3
*Water Heater heat traps IECC 504.7
APPROVED
Duct sealing and insulation N1103.3&4 or IECC
APPROVED
503.3.3.3, 503.3.3.4.3
Heating source and Hot water heater locations have not been shown on plans.
Page 3 of 3