HomeMy WebLinkAboutRESCHECK - 16-00704 - 255 W 2nd N - 4 Plex 2CGenerated by REScheck-Web Software �J( Compliance Certificate Project Hill Tops Apartments Energy Code: Location: Construction Type: Project Type: Conditioned Floor Area: Glazing Area Climate Zone: Permit Date: Permit Number: Construction Site: 2009 1 ECC Rexburg, Idaho Multi -family New Construction 2,225 ft2 2% 6 (8693 HDD) Owner/Agent: Z.✓d Al ll�al NIlI Designer/Contractor: VAJ NIL -L ra.c&z.Tlam,,, Compliance: Passes using UA trade-off Compliance: 0.3% Better Than Code Maximum UA: 358 Your UA: 357 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Ceiling: Cathedral 1,870 38.0 4.0 0.025 47 Wall: Wood Frame, 16in. o.c. 2,880 28.0 0.0 0.050 141 Window: Vinyl Frame, 2 Pane w/ Low -E 46 0.290 13 Door: Solid 19 0.300 6 Floor: Heated Slab -On -Grade 192 8.0 0.779 150 Insulation depth: 2.0' Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. h✓ IlAvS I IAIY/Jt'eX G� Name - Titl Sigoa Date Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 1 of 7 CREScheck Software Version 5.5.0 �(J Inspection Checklist Energy Code: 2009 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. section # Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Req.ID 103.2 ;Construction drawings and ❑Complies [PRI]1 (documentation demonstrate ❑Does Not 0 ; energy code compliance for the ❑Not Observable ;building envelope. ❑Not Applicable ; 103.2, ;Construction drawings and ❑Complies 403.7 documentation demonstrate ❑Does Not [PR311 energy code compliance for Observable I lighting and mechanical systems.❑Not Applicable (Systems serving multiple❑Not ;dwelling units must demonstrate !compliance with the commercial code. i 403.6 Heating and cooling equipment is i Heating: i Heating: ❑Complies [PR2]1 sized per ACOA Manual 5 based Btu/hr I Btu/hr_❑Does Not dj on loads per ACCA Manual J or j Cooling: Cooling: ❑Not Observable other approved methods. I Btu/hr Btu/hr_ ❑Not Applicable Additional Comments/Assumptions: 11 High Impact (Tier 1) Medium Impact (Tier 2) 3 1 Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 2 of 7 section # Foundation Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Re .ID 402.1.1 Slab edge insulation R -value. R-_ R -❑Complies ;Seethe Envelope Assemblies [FO111 ',. El Unheated ❑Unheated ❑Does Not table for values. l� ❑ Heated ❑ Heated ;❑Not Observable ❑Not Applicable I 303.2, !Slab edge insulation installed per ❑Complies ; 402.2.8 !manufacturer's instructions. ❑Does Not [FO211 []Not Observable ❑Not Applicable 402.1.1 '.Slab edge insulation ft ft❑Complies ;See the Envelope Assemblies IFO311 depth/length. ❑Does Not ; table for values. w ;❑Not Observable - :❑Not Applicable 303.2.1 A protective covering is Installed '._ ❑Complies ; [F011]2 to protect exposed exterior '_ ❑Does Not U insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.8 Snow- and ice -melting system ;i ❑Complies ; [FO12]' controls Installed. []Does Not V- ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact (Tier 1) in Medium Impact (Tier 2) 3; 1 Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 3 of 7 section # Framing / Rough -in Inspection -Plans Verified Field Verified Value Value Complies? Comments/Assumptions & Re .ID 402.1.1, Door U -factor. I U- U -❑Complies ;See the Envelope Assemblies 402.3.4 :❑Does Not ;table for values. [FR111�, ;❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U-_ U-_ ;❑Complies :Seethe Envelope Assemblies 402.3.1, .average). :❑Does Not table for values. 402.3.3, I❑Not Observable 402.5 [FR2]1❑Not Applicable ; 303.1.3 U -factors of fenestration products ❑Complies [FR4]1 'pare determined in accordance ❑Does Not ;with the NFRC test procedure or ❑Not Observable ;taken from the default table. ❑Not Applicable 402.4.4 ;Fenestration that is not site built ❑Complies ; [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 ❑Not Observable or has infiltration rates per NFRC 1400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC -rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not U and labeled to indicate 52.0 cfm ❑Not Observable ;leakage at 75 Pa. ❑Not Applicable 403.2.1 ;Supply ducts in attics are 1 R- R-_ ;❑Complies (FR12]1 ;insulated to a11-8. All other ducts R R -❑Does Not in unconditioned spaces or [:]Not Observable ;outside the building envelope are ,insulated to a11-6. I ; ;❑Not Applicable 403.2.2 ,All joints and seams of air ducts, ❑Complies (FR1311 :air handlers, filter boxes, and ❑Does Not ;building cavities used as return ducts are sealed. [-]Not Observable , ❑Not Applicable ; 403.2.3 Building cavities are not used for ❑Complies [FR15]3 supply ducts. ❑Does Not ❑Not Observable ❑Not Applicable 403.3 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 4F or chilled fluids ❑Does Not J below 55 4F are insulated to aR- Observable ; 3❑Not ❑Not Applicable 403.4 Circulating service hot water R- R-_ I❑Complies [FR18]' pipes are insulated to R-2.❑Does Not J ;❑Not Observable ❑Not Applicable 403.5 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air -;❑Does Not J intakes and exhausts. ❑Not Observable {❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) RE Medium Impact (Tier 2) 1 3,.I Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 4 of 7 Section # Insulation Inspection I Plans Verified Value Field Verified Value Complies? Comments/Assumptions & Re .ID 303.1 All installed insulation is labeled ;❑Complies [IN13]2 or the installed R-values ':;❑Does Not provided. 1❑Not Observable - '.3❑Not Applicable j 402.1.1, Wall insulation R-value. If this is a; R- R- ;❑Complies ; See the Envelope Assemblies 402.2.4, mass wall with at least 1/2 of the E] Wood E] Wood I❑Does Not ;table for values. 402.2.5 wall insulation on the wall ; El Mass Mass ;Not Observable (IN311 exterior, the exterior insulation requirement applies. I Q Steel E] Steel :❑Not Applicable 303.2 Wall insulation is installed per ` " ❑Complies [IN4]1 manufacturer's instructions. - ❑Does Not j ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3. 1 Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 5 of 7 Section # Plans Verified Final Inspection Provisions Value Field Verified Value Complies? Comments/Assumptions & Re .ID 402.1.1, :Ceiling insulation R -value. Where; R- ; R-_ ❑Complies see the envelope Assemblies 402.2.1, :> R-30 is required, R-30 can beWood j ❑ Wood❑Does Not table for values. 402.2.2 :used if insulation is not ❑Steel E] Steel ;❑Not Observable [Fill' ;compressed at eaves. R-30 may !be Applicable used for 500 ft' or 20%❑Not ;(whichever is less) where sufficient space is not available. 303.1.1.1, !Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI211 Blown insulation marked every ❑Not Observable 300 ft2. ❑Not Applicable 402.2.3 Attic access hatch and door R-_ R -_❑Complies [FI311 insulation zR-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.2, ;Building envelope tightness ;ACH 50 =_ ;ACH 50 =_❑Complies 402.4.2.1 verified by blower door test result:❑Does Not [FI17]1 :of <7 ACH at 50 Pa. This :❑Not Observable requirement may instead be met :via visual inspection, in which❑Not Applicable case verification may need to ! occur during Insulation :Inspection. ' 403.2.2 : Post construction duct tightness: cfm ; cfm ;❑Complies [FI411 _ :test result of s8 cfm to outdoors, _ 1❑Does Not :or s12 cfm across systems. Or, ; I ;❑Not rough -in test result of s6 cfm Observable across systems or s4 cfm I ! ;❑Not Applicable j without air handler. Rough -in test; verification may need to occur ; during Framing Inspection. 403.1.1 Programmable thermostats ❑Complies [Fig] installed on forced air furnaces. ❑Does Not J []Not Observable ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI 10]2 on heat pumps. ❑Does Not J ❑Not Observable : ❑Not Applicable 403.4 Circulating service hot water- ❑Complies [Flll]2 systems have automatic or ❑Does Not J accessible manual controls. - --"�'.❑Not Observable ;❑Not Applicable 404.1 50% of lamps in permanent ❑Complies [FI611 fixtures are high efficacy lamps. ❑Does Not []Not Observable ❑Not Applicable 401.3 Compliance certificate posted. [Complies [F17]' ❑Does Not J []Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not Q equipment have been provided. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) IM Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 6 of 7 I I High Impact (Tier 1) Medium Impact (Tier 2) +. Low Impact (Tier 3) Project Title: Hill Tops Apartments Report date: 11/28/16 Data filename: Page 7 of 7 Illj(2009 IECC Energy Efficiency Certificate Above -Grade Wall 28.00 Below -Grade Wall 0.00 Floor 8.00 Ceiling / Roof 42.00 Ductwork (unconditioned spaces): Window 0.29 Door 0.30 Heating System: Cooling System: Water Heater: Name: Date: Comments