HomeMy WebLinkAboutRESCHECK - 16-00704 - 255 W 2nd N - 4 Plex 2CGenerated by REScheck-Web Software
�J( Compliance Certificate
Project Hill Tops Apartments
Energy Code:
Location:
Construction Type:
Project Type:
Conditioned Floor Area:
Glazing Area
Climate Zone:
Permit Date:
Permit Number:
Construction Site:
2009 1 ECC
Rexburg, Idaho
Multi -family
New Construction
2,225 ft2
2%
6 (8693 HDD)
Owner/Agent:
Z.✓d Al ll�al NIlI
Designer/Contractor:
VAJ NIL -L ra.c&z.Tlam,,,
Compliance: Passes using UA trade-off
Compliance: 0.3% Better Than Code Maximum UA: 358 Your UA: 357
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home.
Ceiling: Cathedral 1,870 38.0 4.0 0.025 47
Wall: Wood Frame, 16in. o.c. 2,880 28.0 0.0 0.050 141
Window: Vinyl Frame, 2 Pane w/ Low -E 46 0.290 13
Door: Solid 19 0.300 6
Floor: Heated Slab -On -Grade 192 8.0 0.779 150
Insulation depth: 2.0'
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in
REScheck Version 5.5.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
h✓ IlAvS I IAIY/Jt'eX G�
Name - Titl Sigoa Date
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 1 of 7
CREScheck Software Version 5.5.0
�(J Inspection Checklist
Energy Code: 2009 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
section
#
Pre-Inspection/Plan Review
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
& Req.ID
103.2
;Construction drawings and
❑Complies
[PRI]1
(documentation demonstrate
❑Does Not
0
; energy code compliance for the
❑Not Observable
;building envelope.
❑Not Applicable ;
103.2,
;Construction drawings and
❑Complies
403.7
documentation demonstrate
❑Does Not
[PR311
energy code compliance for
Observable I
lighting and mechanical systems.❑Not
Applicable
(Systems serving multiple❑Not
;dwelling units must demonstrate
!compliance with the commercial
code.
i
403.6
Heating and cooling equipment is i
Heating:
i Heating:
❑Complies
[PR2]1
sized per ACOA Manual 5 based
Btu/hr
I Btu/hr_❑Does
Not
dj
on loads per ACCA Manual J or
j
Cooling:
Cooling:
❑Not Observable
other approved methods.
I
Btu/hr
Btu/hr_
❑Not Applicable
Additional Comments/Assumptions:
11 High Impact (Tier 1) Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 2 of 7
section
#
Foundation Inspection
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
& Re .ID
402.1.1
Slab edge insulation R -value.
R-_ R -❑Complies
;Seethe Envelope Assemblies
[FO111
',.
El Unheated ❑Unheated
❑Does Not table for values.
l�
❑ Heated ❑ Heated
;❑Not Observable
❑Not Applicable
I
303.2,
!Slab edge insulation installed per
❑Complies ;
402.2.8
!manufacturer's instructions.
❑Does Not
[FO211
[]Not Observable
❑Not Applicable
402.1.1
'.Slab edge insulation
ft ft❑Complies
;See the Envelope Assemblies
IFO311
depth/length.
❑Does Not ; table for values.
w
;❑Not Observable
-
:❑Not Applicable
303.2.1
A protective covering is Installed
'._
❑Complies ;
[F011]2
to protect exposed exterior
'_
❑Does Not
U
insulation and extends a
❑Not Observable
minimum of 6 in. below grade.
❑Not Applicable
403.8
Snow- and ice -melting system
;i
❑Complies ;
[FO12]'
controls Installed.
[]Does Not
V-
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) in Medium Impact (Tier 2) 3; 1 Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 3 of 7
section
#
Framing / Rough -in Inspection
-Plans Verified Field Verified
Value Value
Complies?
Comments/Assumptions
& Re .ID
402.1.1,
Door U -factor. I
U- U -❑Complies
;See the Envelope Assemblies
402.3.4
:❑Does Not ;table for values.
[FR111�,
;❑Not Observable
❑Not Applicable
402.1.1,
;Glazing U-factor(area-weighted
U-_ U-_
;❑Complies :Seethe Envelope Assemblies
402.3.1,
.average).
:❑Does Not table for values.
402.3.3,
I❑Not Observable
402.5
[FR2]1❑Not
Applicable
;
303.1.3
U -factors of fenestration products
❑Complies
[FR4]1
'pare determined in accordance
❑Does Not
;with the NFRC test procedure or
❑Not Observable
;taken from the default table.
❑Not Applicable
402.4.4
;Fenestration that is not site built
❑Complies ;
[FR20]1
is listed and labeled as meeting
❑Does Not
AAMA/WDMA/CSA 101/I.S.2/A440
❑Not Observable
or has infiltration rates per NFRC
1400 that do not exceed code
❑Not Applicable
limits.
402.4.5
IC -rated recessed lighting fixtures
❑Complies
[FR16]2
sealed at housing/interior finish
❑Does Not
U
and labeled to indicate 52.0 cfm
❑Not Observable
;leakage at 75 Pa.
❑Not Applicable
403.2.1
;Supply ducts in attics are 1
R- R-_
;❑Complies
(FR12]1
;insulated to a11-8. All other ducts
R R -❑Does
Not
in unconditioned spaces or
[:]Not Observable
;outside the building envelope are
,insulated to a11-6. I
;
;❑Not Applicable
403.2.2
,All joints and seams of air ducts,
❑Complies
(FR1311
:air handlers, filter boxes, and
❑Does Not
;building cavities used as return
ducts are sealed.
[-]Not Observable
,
❑Not Applicable ;
403.2.3
Building cavities are not used for
❑Complies
[FR15]3
supply ducts.
❑Does Not
❑Not Observable
❑Not Applicable
403.3
HVAC piping conveying fluids
R- R-
❑Complies
[FR17]2
above 105 4F or chilled fluids
❑Does Not
J
below 55 4F are insulated to aR-
Observable ;
3❑Not
❑Not Applicable
403.4
Circulating service hot water
R- R-_
I❑Complies
[FR18]'
pipes are insulated to R-2.❑Does
Not
J
;❑Not Observable
❑Not Applicable
403.5
Automatic or gravity dampers are
❑Complies
[FR19]2
installed on all outdoor air
-;❑Does Not
J
intakes and exhausts.
❑Not Observable
{❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) RE Medium Impact (Tier 2) 1 3,.I Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 4 of 7
Section
#
Insulation Inspection
I
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
& Re .ID
303.1
All installed insulation is labeled
;❑Complies
[IN13]2
or the installed R-values
':;❑Does
Not
provided.
1❑Not Observable
-
'.3❑Not Applicable j
402.1.1,
Wall insulation R-value. If this is a;
R-
R-
;❑Complies ; See the Envelope Assemblies
402.2.4,
mass wall with at least 1/2 of the
E] Wood
E] Wood
I❑Does Not ;table for values.
402.2.5
wall insulation on the wall
; El Mass
Mass
;Not Observable
(IN311
exterior, the exterior insulation
requirement applies.
I Q Steel
E] Steel
:❑Not Applicable
303.2
Wall insulation is installed per
` "
❑Complies
[IN4]1
manufacturer's instructions.
-
❑Does Not j
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) 3. 1 Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 5 of 7
Section
#
Plans Verified
Final Inspection Provisions Value
Field Verified
Value
Complies? Comments/Assumptions
& Re .ID
402.1.1,
:Ceiling insulation R -value. Where; R-
; R-_
❑Complies see the envelope Assemblies
402.2.1,
:> R-30 is required, R-30 can beWood
j ❑ Wood❑Does
Not table for values.
402.2.2
:used if insulation is not ❑Steel
E] Steel
;❑Not Observable
[Fill'
;compressed at eaves. R-30 may
!be
Applicable
used for 500 ft' or 20%❑Not
;(whichever is less) where
sufficient space is not available.
303.1.1.1,
!Ceiling insulation installed per
❑Complies
303.2
manufacturer's instructions.
❑Does Not
[FI211
Blown insulation marked every
❑Not Observable
300 ft2.
❑Not Applicable
402.2.3
Attic access hatch and door R-_
R -_❑Complies
[FI311
insulation zR-value of the
❑Does Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.2,
;Building envelope tightness ;ACH 50 =_
;ACH 50 =_❑Complies
402.4.2.1
verified by blower door test result:❑Does
Not
[FI17]1
:of <7 ACH at 50 Pa. This
:❑Not Observable
requirement may instead be met
:via visual inspection, in which❑Not
Applicable
case verification may need to
! occur during Insulation
:Inspection.
'
403.2.2
: Post construction duct tightness: cfm
; cfm
;❑Complies
[FI411
_
:test result of s8 cfm to outdoors,
_
1❑Does
Not
:or s12 cfm across systems. Or, ;
I
;❑Not
rough -in test result of s6 cfm
Observable
across systems or s4 cfm I
!
;❑Not Applicable j
without air handler. Rough -in test;
verification may need to occur
;
during Framing Inspection.
403.1.1
Programmable thermostats
❑Complies
[Fig]
installed on forced air furnaces.
❑Does Not
J
[]Not Observable
❑Not Applicable
403.1.2
Heat pump thermostat installed
❑Complies
[FI 10]2
on heat pumps.
❑Does Not
J
❑Not Observable :
❑Not Applicable
403.4
Circulating service hot water-
❑Complies
[Flll]2
systems have automatic or
❑Does Not
J
accessible manual controls. -
--"�'.❑Not
Observable
;❑Not Applicable
404.1
50% of lamps in permanent
❑Complies
[FI611
fixtures are high efficacy lamps.
❑Does Not
[]Not Observable
❑Not Applicable
401.3
Compliance certificate posted.
[Complies
[F17]'
❑Does Not
J
[]Not Observable
❑Not Applicable
303.3
Manufacturer manuals for
❑Complies
[FI18]3
mechanical and water heating
❑Does Not
Q
equipment have been provided.
[]Not Observable
❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) IM Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 6 of 7
I I High Impact (Tier 1) Medium Impact (Tier 2) +. Low Impact (Tier 3)
Project Title: Hill Tops Apartments Report date: 11/28/16
Data filename: Page 7 of 7
Illj(2009 IECC Energy
Efficiency Certificate
Above -Grade Wall 28.00
Below -Grade Wall 0.00
Floor 8.00
Ceiling / Roof 42.00
Ductwork (unconditioned spaces):
Window 0.29
Door 0.30
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments