HomeMy WebLinkAboutREVIEW BLDG PLAN - 16-00704 - 255 W 2nd N - 4 Plex 2;o�gexauq�,d C IT Y OF Community Development Department
s 7535 g I East
0 l�XB V RG Rexburbur , D 83440
tw Permit Technician (208) 372-2341
=o
Americas Family Community Inspection Hotline (208) 372-2344
Residential Building Review on 11/08/2016:
Permit Details Permit Number: 16-00704
255 W 2nd N - 4 Plex 2 Multi -Family Residential
255 W 2nd N Permit Issued Date:
Final Inspections Required
Inspection Details
Residential Building Review on 11/08/2016:
Inspected By: Ted Dye
tedd@rexburg.org
Page 1 of 3
Plans match quantities & values on a "passing"
RES check compliance report
Provide RES/check
REVISIONS
Truss Calculation Sheets
Truss spec's need to be provided
REVISIONS
Flood Plain
NO
Floor/Foundation Plan
APPROVED
Section showing construction details
APPROVED
All Building Elevations
APPROVED
Design Criteria (identified on plans as Wind -85
mph, Snow-35l1b./s . R.
APPROVED
To Scale
APPROVED
Legible
APPROVED
Plot Plan
By Natalie
APPROVED
Room access 36" min width/Attic access clear
opening 20x30/Under floor r.o 2200 M 306.2;
306.3 & 306.4
APPROVED
Dyer Vent length 35' max w/8' transition (-5 per
90 deg turns) M504.6.41
APPROVED
Appendix F
APPROVED
1/2" Anchor bolts with 3" x 3" x 1/4" square
washers incl. interior bearing walls R403.1.6.1
APPROVED
Foundation Drainage (foundations on sift soil
shall be designed per R405
APPROVED
Grading slope away from house. R401.3
APPROVED
Floor Joist Details
APPROVED
Front set back (32 ft. from curb)
APPROVED
60% minimum of front yard green
APPROVED
Rear set back (LDRI 25 ft. & LDR2 20 ft.)
APPROVED
Page 1 of 3
CITY OF
REXBURG
C
America's Family Community
Permit Number: 16-00704
(Continued)
Sides set backs (6" for every ft. of building
APPROVED
height with LDR - 7.5' min., & LORI - 6' min.
Building -Height (max. 30 ft.)
APPROVED
Proper Size (as per Table 403. 1, use 1500 psf
APPROVED
unless soil type is known, Table 401.4.1 for soil
bearing)
Rebar (244 continuous)
APPROVED
Footing Depth (36" below finished grade and 12"
Shallow footing design
APPROVED
below undisturbed soil; 18" to top of slab -
interior
All rebar is tied in place with proper lap?
APPROVED
Rebar is correct size and spaced as per plans?
APPROVED
Rebar is a minimum or 1" from forms?
APPROVED
Seismic Hold Downs and Braced wall Panels
APPROVED
(11602.10
Floors joists sized as per R502.3, Wood I -joists
APPROVED
sized per manufr.
Joists Under Load Bearing Partitions shall be
APPROVED
doubled. R502.4
Girders sized per R502.5 or per manufr. Tables
APPROVED
for engineered products
Floor Sheathing (3/4" min for joists, 24" oc & 5/8
APPROVED
for joists 16") R503.2.2
Wall(bearing and nonbearing)stud sizes, hght &
APPROVED
spacing er Thl 602.3(5) R6023
Headers in Bearing Wall designed as per Tables
APPROVED
502.51&2 R602.7 "
Roof Trusses (designed according to R802.10.1)
APPROVED
35 # Snow and 90 mph winds Local Conditions)
Rafter and Truss tie -downs R802.10.5
APPROVED
Attic Access 22" x 30" min. opening R807
APPROVED
Roof Ventilation as per R806
APPROVED
Asphalt Shingles(slp>2:12) w/ice protection or
APPROVED
Other type to comply w/R905
Twin homes & townhouses (2 hr sep. & 4'
APPROVED
overburn protection or parapet) R317.2
1 hr walls parallel to and within 3 ft. of prop. line
APPROVED
w/ No openings R302
Penetrations in previous 3 items to comply with
APPROVED
R317.3
House Numbers R321
APPROVED
Interior and exterior stair illumination shall
APPROVED
comply with R303.6
Bathroom Fixture clearances comply with Figure
APPROVED
R307.2
Page 2 of 3
C I TY OF
REXBURG
0
America's Family Community
Permit Number: 16-00704
(Continued)
*Areas w/ sloped veilings less than 5 ft, in height
APPROVED
& furred ceilings less than 7 ft DO NOT comply.
*50% or more of the required area must be at
least 7ft high in rooms w/slo ed ceiling
Glazing at Hazardous Locations R308
APPROVED
Emergency Egress in all sleeping rooms and
APPROVED
basements w/ habitable space R310
One required Exit Door shall comply with 2311.2
APPROVED
Landings at top and bottom of stairways
APPROVED
R311.7.5 and each side of each exterior door. R
311.3
Stairway Headroom (6'8")
APPROVED
Special conditions for circular, spiral and winder
APPROVED
stairways and bulkhead enclosures R311.7.9.1
Stairway protection (enclosed accessible space
APPROVED
under stairs shall be covered with 1/2" drywall)
R311.2.2
Guardrails complying with R312
APPROVED
Half openable 3sf window or Mech. Ventilation in
APPROVED
bathrooms, water closets, and similar rooms.
R303.3
One room at least 120 sf
APPROVED
Smoke Alarms (each bedroom and common area
APPROVED
and 1 on each level) R314
Vapor retarder on warm in winter side of walls,
APPROVED
ceiling and Floors R601.3
*Water Heater heat traps IECC 504.7
APPROVED
Duct sealing and insulation N1103.3&4 or IECC
APPROVED
503.3.3.3, 503.3.3.4.3
Inspector Comments
Heating source and Hot water heater locations have not been shown on plans
Page 3 of 3