Loading...
HomeMy WebLinkAboutRESCHECK - 16-00578 - 1032 Larch - SFRREScheck Software Version 4.6.2 AV L ir Compliance Certificate Project Redline Pinebrook Est. Energy Code: 2012 IECC 21.0 Location: Pocatello, Idaho 20 Construction Type: Single-family Project Type: New Construction 13 Conditioned Floor Area: 4,063 11:2 21.0 Glazing Area 16% 18 Climate Zone: 6 (7180 HDD) 21.0 Permit Date: 0.057 1 Permit Number: 10 Construction Site: Owner/Agent: Designer/Contractor: Wall 4: Wood Frame, 16" o.c. Greenworks Const. COMFORT AIR DESIGN DBA WIEMER 0.0 0.057 HEATING Window 1: Other:Single Pane 15 COMFORT AIR DESIGN DBA WIEMER 0.280 HEATING Wall 5: Wood Frame, 16" D.C. 489 IDAHO FALLS, ID 0.0 • 208-523-3848 .Y• Compliance: 2.1% Better Than Code Maximum UA: 421 Your UA: 412 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Wall 1: Wood Frame, 16" D.C. 400 21.0 0.0 0.057 20 Window 1: Other:Single Pane 46 0.280 13 Wall 2: Wood Frame, 16" D.C. 324 21.0 0.0 0.057 18 Wall 3: Wood Frame, 16" D.C. 24 21.0 0.0 0.057 1 Window 1: Other:Single Pane 10 0.280 3 Wall 4: Wood Frame, 16" o.c. 40 21.0 0.0 0.057 1 Window 1: Other:Single Pane 15 0.280 4 Wall 5: Wood Frame, 16" D.C. 489 21.0 0.0 0.057 20 Window 1: Other:Single Pane 136 0.280 38 Wall 6: Wood Frame, 16" D.C. 166 21.0 0.0 0.057 7 Window 1: Other:Single Pane 45 0.280 13 Wall 7: Wood Frame, 16" D.C. 27 21.0 0.0 0.057 1 Window 1: Other:Single Pane 10 0.300 3 Wall 8: Wood Frame, 16" D.C. 42 21.0 0.0 0.057 2 Window 1: Other:Single Pane 15 0.280 4 Project Title: Redline Pinebrook Est. Report date: 08/17/16 Data filename: C:\Users\User\AppData\Local\Check\REScheck\ Green Works Const. Redline Pinebrook Page 1 of 2 Est.rck Wall 9: Wood Frame, 16" o.c. 400 21.0 0.0 0.057 22 Window 1: Other:Single Pane 14 0.280 4 Wall 10: Wood Frame, 16" o.c. 324 21.0 0.0 0.057 18 Wall 11: Wood Frame, 16" o.c. 522 21.0 0.0 0.057 23 Door 1: Solid 40 0.140 6 Window 1: Other:Single Pane 78 0.280 22 Wall 12: Wood Frame, 16" o.c. 241 21.0 0.0 0.057 12 Window 1: Other:Single Pane 26 0.280 7 Basement Wall 1: Solid Concrete or Masonry 382 19.0 0.0 0.047 18 Wall height: 9.0' Depth below grade: 7.0' Insulation depth: 9.0' Basement Wall 2: Solid Concrete or Masonry 522 19.0 0.0 0.047 21 Wall height: 9.0' Depth below grade: 7.0' Insulation depth: 9.0' Window 1: Other:Single Pane 68 0.280 19 Basement Wall 3: Solid Concrete or Masonry 385 19.0 0.0 0.047 18 Wall height: 9.0' Depth below grade: 7.0' Insulation depth: 9.0' Basement Wall 4: Solid Concrete or Masonry 522 19.0 0.0 0.047 24 Wall height: 9.0' Depth below grade: 7.0' - Insulation depth: 9.0' Window 1: Other:Single Pane 20 0.280 6 Ceiling 1: Flat Ceiling or Scissor Truss 1,679 50.0 0.0 0.026 44 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name - Title Signature Project Notes: job Number: Redline Pinebrook Est. INFORMATION CONTAINED WITHIN THE REPORT IS PER THE RESCHECK COMPLIANCE CERTIFICATE. IF ANY OF THESE VALUES SHOULD CHANGE, THIS REPORT WILL BE NULL AND VOID. Project Title: Redline Pinebrook Est. Report date: 08/17/16 Data filename: C:\Users\User\AppData\Local\Check\REScheck\ Green Works Const. Redline Pinebrook Page 2 of 2 Est.rck 2012 IECC Energy Efficiency Certificate s ' Above -Grade Wall 21,00 Below -Grade Wall 19.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): ao Window 0.28 Door 0.14 Heating System: Cooling System: Water Heater: Name: Comments Date: