Loading...
HomeMy WebLinkAboutRESCHECK - 16-00551 - 1070 Washington Blvd - New SFR1ZREScheck Software Version 4.6.2 Compliance Certificate Project FS2B1 - Jamestown Energy Code: 2012 IECC Location: Rexburg, Idaho Construction Type: Single-family Project Type: New Construction Orientation: Bldg. faces 90 deg. from North Conditioned Floor Area: 3,530 ft2 Glazing Area 20% Climate Zone: 6 (8693 HDD) Permit Date: Permit Number: 0 Construction Site: Owner/Agent: Rexburg, ID 83440 0.057 Designer/Contractor: Kartchner Homes 84321 435-755-7080 John@kartchnerhomes.com Compliance: Passes using LIA trade-off Compliance: 1.4% Better Than Code Maximum UA: 292 Your UA: 288 The % Better or Worse Than Cade Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum -code home. Envelope Assemblies Ceiling 1: Flat Ceiling or Scissor Truss Main Wall Front: Wood Frame, 16" o.c. Orientation: front Window 4: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front Door 1: Solid Orientation: Front Main Wall Right: Wood Frame, 16" o.c. Orientation: Right side Main Wall Rear:. Wood Frame, 16" o.c. Orientation: Back Window 5: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Back Main Wall Left: Wood Frame, 16" o.c. Orientation: Left side Basement Wall Front: Solid Concrete or Masonry Orientation: Front Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 6: Vinyl/Fiberglass Frame:Double Pane with Low -E Orientation: Front 1,765 50.0 0.0 0.026 46 608 21.0 0.0 0.057 27 90 0.320 29 40 0.010 0 175 21.0 0.0 0.057 10 488 21.0 0.0 0.057 21 125 0.320 40 278 21.0 0.0 0.057 16 608 0.0 13.0 0.047 28 20 0.320 6 Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2Bl.rck Page 1 of 9 Basement Wall Right: Solid Concrete or Masonry 174 0.0 13.0 0.047 8 Orientation: Right side Wall height: 8.0' Depth below grade: 8.0'. Insulation depth: 8.0' Basement Wall Rear: Solid Concrete or Masonry 488 0.0 13.0 0.047 20 Orientation: Back Wall height: 8.0' Depth below grade: 8.0' Insulation depth: 8.0' Window 7: Vinyl/Fiberglass Frame:Triple Pane 60 0.320 19 Orientation: Back Basement Wall Left: Solid Concrete or Masonry 278 0.0 13.0 0,047 12 Orientation: Left side Wall height: 8,0' Depth below grade: 8.0' Insulation depth: 8.0' Window 8: Vinyl/Fiberglass Frame:Double Pane with Low -E 20 0.320 6 Orientation: Left side Compliance Statement., The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2012 IECC requirements in REScheck Version 4.6.2 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Name -Title Signature Date Project Notes: Founder Square Subd Block: 1, Lot: 2 Rexburg, ID 83440 Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2Bl.rck Page 2 of 9 fZREScheck Software Version 4.6.2 Inspection Checklist Energy Code: 2012 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Pre-Inspection/Plan Review Plans Verified' Fleld`Verified '.. Value Ualue Complies? Comments/Assumptions 103.1, ;Construction drawings and ❑Complies 103.2 ;documentation demonstrate,., ° '",. "�, u,<<^,_ $ :- ❑Does Not , [PR1]1 :energy code compliance for the a ra ❑Not Observable j 4building envelope. �„ i' X t.'[]Not Applicable 103.1. 103 2, ;Construction drawings and ;documentation demonstrate 1[ - ` °�r� ❑Complies v� ° ' ❑Does Not 403.7 [PR3]1 : energy code compliance for :li htin and mechanicals stems :lighting Y va +" dna " < '° , ❑Not Observable „s 'Systems servingmultiple �❑Not Applicable „ ;dwelling units must demonstrate (compliance with the IECC ;Commercial Provisions. 3Q2.1, ;Heating and cooling equipment is; Heating: ; Heating;❑Complies 403.6 ;'sized per ACCA Manual S based 1 Btu/hrBtu/hr ❑Does Not [PR2]2 '.; on loads calculated per ACCA Cooling: I Cooling:❑Not Observable U Manual J or other methods approved by the code official. Btu/hr j Btu/hr❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12;: Medium Impact (Tier 2) 1, 3'1 Low Impact (Tier 3) Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2Bl.rck Page 3 of 9 Section # `Foundation Inspection Plans Verified Field Verified Complies? Comments/Assumptions & Req.ID -:: value Value 402.1.1 !Conditioned basement wall R- R- _ ;❑Complies ;see the Envelope Assemblies [F0411 ;insulation R -value. Where interior; R R -❑Does Not table for values. 119) insulation is used, verification j❑Not Observable i may need to occur during i Insulation Inspection. Not ;❑Not Applicable ;required in warm -humid locations; in Climate Zone 3. 303.2 (Conditioned basement wall ❑Complies [F0511 insulation installed per , ref"`'' '� J❑Does Not manufacturer's instruction❑Not a Observable ,', ❑Not Applicable 402.2.8 Conditioned basement wall ft ft ;❑Complies ;See the Envelope assemblies [F0611 'insulation depth of burial or ;❑Does Not ;table for values. lgJ❑Not distance from top of wall. Observable ❑Not Applicable 303.2.1 JA protective covering is installed `. 3 " �� s° ,„ al# ❑Complies [F011]2 �to protect exposed exterior , ], } �'[ ``r"�. []Does Not ' 1 insulation and extends a ' ❑Not Observable minimum of 6 in. below grade +rf�' }i []Not Applicable 403.8 f Snow- and ice -melting system �` z ❑Complies [F012]2 controls installed.. ] [' a�,�{,r ❑Does Not ❑Not Observable ❑Not Applicable j 1 _* Additional Comments/Assumptions: 11 High Impact (Tier 1) 271 Medium Impact (Tier 2) 1 3 Low Impact (Tier 3) Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS261.rck Page 4 of 9 Section # Framing1.Rough-In Inspection Plans Verified Field Verified Value.` Value Complies? `. Comments/Assumpt[ons & Req.113 - 402.1.1, ;Door U -factor. ; U-_ ; U- I❑Complies ; See the Envelope Assemblies 402.3.4 !❑Does Not ; table for values. [FR1]1 ;❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U-_ U- ;❑Complies ; See the Envelope Assemblies 402.3.1, average). ;❑Does Not table for values. 402.3.3, 402.3.6, ;❑Not Observable 402.5 ;❑Not Applicable [FR2]1 303 1.3 ; U -factors of fenestration products? Y ,„s ❑Complies [FR411 ;are determined in accordance ;with the NFRC test or,� < ;`� i�. ry + ❑Does Not 44 procedure (taken from the default table u�uF1f ❑Not Observable „< ,r❑Not Applicable 402.4.1.1 ;Air barrier and thermal barrier 1.*^ +� ? [FR2311 installed per manufacturers h§❑Complies s.. ' ❑Does Not linstructions. ❑Not Observable ❑Not Applicable 402.4.3 I Fenestration that is not site built i °� '. " ❑Complies [FR2011 is listed and labeled as meeting .< �J ' ` i�'la ❑Does Not AAMA /WDMA/CSA 101/I,S.2/A440 "", ❑Not Observable or has infiltration rates per NFRC�-' ;400 that do not exceed code .. ❑Not Applicable !limits. 402.4.4 ,,SIC -rated recessed lighting fixtures �`a+ �''x�M 'i*"if ['rf`1` ❑Complies [FR16]1 ;sealed at housing/interior finish r�',>,` �„, I� ❑Does Not V and labeled to indicate <2 0 cfm 7, t :. ❑Not Observable ; leakage at 75 Pa. ° , w,' a phi ❑Not Applicable 403.2.1 Supply ducts in attics are ; R-_ R- ;❑Complies [FR1211 insulated to aR-8. All other ducts ; R_ R- ;❑Does Not in unconditioned spaces or '1 outside the building envelope are ; ;❑Not Observable .insulated to aR-6. ;❑Not Applicable 403.2.2 ;All joints and seams of air ducts t1 `v' +s `'r"" ` " '. ❑Complies [FR13]1 lairhandlers, and filter boxes ;sealed. ❑Does Not ❑Not Observable x �' , l,' - ❑Not Applicable 403 2 3 ;Building cavities are not used as-�� 'ducts ; r �rS��x�,u"r 'r ❑Complies [FR15]3 or plenums. � -' f � a� re ❑Does Not ❑Not Observable ; ❑Not Applicable 403.3 j HVAC piping conveying fluids 1 R- ; R- ;❑Complies 1,FR17]' I above 105 OF or chilled fluids UDoes Not Ibelow 55 °F are insulated to >_R- ;❑Not Observable -;3. ;❑Not Applicable 403.3.1 [FR2411 ',Protection of insulation on HVAC )piping. '� r ❑Complies ❑ Does Not I ` ❑Not Observable , ❑Not Applicable 403.4,.2 Hot water pipes are insulated to ; R- R-_ ;❑Complies ; [FRl8)2 'i aR-3. ❑Does Not ;❑Not Observable I❑Not Applicable 1 I High Impact (Tier 1) 12, 1 Medium Impact (Tier 2) 13!1 Low Impact (Tier 3) Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users�hoellein\Documents\REScheck\FS2Bl.rck Page 5 of 9 Section # Framing / Rough -in Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 4015 i,; Automatic or gravity dampers are �1 ga,�; V'Uffl,� "U'lElcomplies [Fft�9]2 1 installed on all outdoor air E]Does Not intakes and exhausts. E]Not Observable AWdiOpnaUCmnmmmemts/&ssmmmptioms: 111 High Impact (Tier 1) 1,2 1 Medium Impact (Tier 2) 13 1 Low impact (Tier 3) Project Title: [3ZDl'Jamestown Report date: 07/28/l0 Data filename: [:\Usecs�hoeUein\Docunoeot$K[5check\FSZOl.rrk Page 6of 9 +SectionPlans #. Insulation Inspection Verified Field Verified Value Value Complies? Comments/Assumptions'. .& Req.ID 303.1 !All installed insulation is labeledi•.` ❑Complies [IN13]2 j or the installed R -values '` ° ❑Does Not :I provided. ;r s '` [-]Not Observable ❑Not Applicable 402.1.1, :Wall insulation R -value. If this is a; R- Ry-_ I❑Complies ;See the Envelope Assemblies 402.2.5, :mass wall with at least 1h of the ❑ Wood ; E]Wood❑Does Not ;table for values. 402.2.6 wall insulation on the wall E] Mass El Mass❑Not Observable [IN3]1 , exterior, the exterior insulation :requirement applies (FR10). ❑ Steel I❑ Steel❑Not Applicable 303.2 :Wall insulation is installed per ❑Complies [IN4]1 :manufacturer's instructions ❑Does Not , a� NI'M ❑Not Observable � ik ",yf *,�.t- - a� t:. ❑Not Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 2 1 Medium Impact (Tier 2) ' 3 +1 Low Impact (Tier 3) Project Title: FS2Bl - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2B1.rck Page 7 of 9 Section # I Final Inspection Provisions Plans Verified Field Verified a Value .Value Complies? Comments/Assumptions '.. Re .[D. 402.1.1, ;Ceiling insulation R -value. R- R-_ ;❑Complies See the envelope Assemblies 402.2.1, Wood ; ❑ Wood :❑Does Not table for values. 402.2.2, Steel ❑ Steel ;❑Not Observable 402.2.6 [Fill' ❑ Not Applicable iV 303.1.1.1, ;Ceiling insulation installed per Fq '°'�" I ` '' ,,tti` d;�.MElNot ❑Complies 303.2 ; manufacturer's instructions r ,�' a� ❑Does Not [F1211 :Blown insulation marked every 3, r y ";300ft'.❑NotbbservableYr, ,,� Applicable 402.23 [FI2212 ;Vented attics with air permeable„ 1 insulation include baffle adjacent Y . r �'b� r ❑Complies ❑Does Not soffit and eave vents that i " Ito extends over insulation. _' ❑Not Observable ', ❑Not Applicable 402.2.4 ;Attic access hatch and door ; R-_ ; R -_❑Complies [F1311 >_R -value of the j❑Does Not !adjacent ; adjacent assembly. �. ;❑NotObservable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 =_ ACH 50 =_❑Complies [FI1711 ach in Climate Zones 1-2, and ;❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable 1 ❑Not Applicable 403.2.2 Duct tightness test result of <=4 I cfm/100 cfm/100❑Complies [F1411. cfm/100 ft2 across the system or ; ft' I ft' I❑Does Not U! <=3 cfm/100 ft2 without air❑Not Observable :handler@ 25 Pa. For rough -in !tests, Applicable verification may need to❑Not l occur during Framing Inspection.; f❑Complies 403.2.2.1 :Air handler leakage designated :;`°.„ sF .� /• 4 ': [F[24]1 l by manufacturer at <=2% of ❑Does Not l design air flow. []Not Observable ! ❑Not Applicable 403.1.1. Programmable thermostats ;k'.T °�.�. �,�,., �'° ' ❑Com �. p' lies [FI9]2 hnstalled on forced air furnaces i "`3� ' ❑Does Not ❑Not Observable e;= ❑Not Applicable 403.1;2 Heat pump thermostat installed tL.;_ ❑Complies [Fllbl? ' i on heat pumps. t . ❑Does Not U ( sg❑Not Observable ❑Not Applicable �.❑Complies 403.4:1 :! Circulating service hot water 1 _1'e,`,E [Fill]?systems have automatic or , ` `vt ❑Does Not :;accessible manual controls 't"•. y � - ❑Nat Observable uAlr ❑Not Applicable 403.5.1 All mechanical ventilation system ' " : 1 1n � a • ❑Complies [FI25]2 fans not part of tested and listed #w s 1 ° s ❑Does Not . ; HVAC equipment meet efficacy ;and airflow limits, °r 1, "-❑Not Observable 'i ❑Not Applicable ce,„ 404.1 :75% of lamps in permanent '",' `�,1 �''#u r�"Etd4+�r,❑Complies [F1611 'fixtures or 75% of permanent !fixtures 1' ,JM, ❑Does Not V have high efficacy lamps §,. E : ❑Not Observable Does not apply to low -voltage " ' �, ", ❑Not Applicable !lighting. 1 High Impact (Tier 1) 1 2: Medium Impact (Tier 2) 1 3'1 Low Impact (Tier 3) Project Title: FS2B1 - Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\F52Bl.rck Page 8 of 2 Section # Final Inspection Provisions Plans Verified Field Verified ',. Value - Complies? Comments/Assumptions &:Req.11) ,Value , . , 494.7,.1 !Fuel gas lighting systems have �,w❑Does ";gi,�� '';, ,"NEINot []Complies 1Fi231s !no continuous pilot light. 4 ��.l,i,tjry�, Er Not ',n'Ite,y❑Not Observable� Applicable .�Compliance certificate posted ? ❑Complies [0I)2 ❑Does Not �J 0105 ❑Not Observable 5..:' Sf^7,.r ❑Not Applicable 3033 I Manufacturer manuals for❑Complies [FI1813. +mechanical and water heating �hra ❑Does Not ,g r�'a; `v `systems have been provided ,r;`�¢'`�t , t ?' []Not Observable ❑Nob Applicable Additional Comments/Assumptions: 1 IHigh Impact (Tier 1) 12 1 Medium Impact (Tier 2) 1,3JLow Impact (Tier 3) Project Title: FS2B1-Jamestown Report date: 07/20/16 Data filename: C:\Users\jhoellein\Documents\REScheck\FS2Bl.rck Page 9 of 9 2012 IECC Energy Efficiency Certificate Above -Grade Wall 21.00 Below -Grade Wall 13.00 Floor 0.00 Ceiling / Roof 50.00 Ductwork (unconditioned spaces): Window 0.32 Door 0.01 Heating System: Cooling System: Water Heater: Name: Date: Comments