Loading...
HomeMy WebLinkAboutLOAD SHORT FORM - 16-00551 - 1070 Washington Blvd - New SFRLoad Short Form Job: FS2B1 Date: 7122116 Entire House By: Vince Byram Modern Plumbing Heating and Electric 4N...gteainp 3939 E 240 N, Rigby, Id 83442 Phone. 208-745-7021 Fax: 208-745-7329 Email: Vince®modemphe.com For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Htg Clg Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality Semi -tight Design TO (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT COOLING EQUIPMENT Make Amana Area (f2) Htg load (Btuh) Make Amana Htg AVF (cfm) Clg AVF (cfm) Trade Amana 178 1685 Trade Amana 47 32 Model GMH950703BX 179 1640 Cond GSX13024 46 22 AHRI ref 2002182 122 541 Coil CA*F3030 15 0 Room7 744 4715 AHRI ref 4886848 131 65 Efficiency 95 AFUE 1358 Efficiency 11.5 EER, 14 SEER Heating input 69000 Btuh Sensible cooling 17700 Btuh Heating output 52960 Btuh Latent cooling 0 Btuh Temperature rise. 67 OF Total cooling 17700 Btuh Actual air flow 859 cfm Actual airflow 859 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area (f2) Htg load (Btuh) CIg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Room3 178 1685 589 47 32 Room4 179 1640 410 46 22 Rooms 122 541 3 15 0 Room7 744 4715 1182 131 65 Room8 172 1358 581 38 32 Room10 262 3027 1694 84 93 Roomll 50 740 401 21 22 Room12 145 2501 1365 70 75 Room13 163 2313 1360 64 74 Room14 88 1016 574 28 31 Room15 864 9300 6437 258 352 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ea 2016 -Jul -22 15:20:41 WlrlgtltSOft" Right -Suite® U niversal 2017 17.0.03 RSU20477 Pagel M.riA�...ofhvare\Kartchner\Jameslown\F82B1 jameslowo.rup Cola =MJ8 Front Door faces;E Entire House d 3079 30905 15699 859 859 Other equip loads 11683 983 Equip. @ 0.94 RSM 15681 Latent cooling 0 T Al C I 911911 I AOGOO I ncco.l 59 859 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 201&Jul-2215:20:41 -�1-wrightsof#' Right-Suite®UnNersal201717.0.03RSU20477 Paget I CM...oftware\"rtchnerWamestown\FS2e1 jamestown.rup Calc = MJ8 Front Door faces: E Heating Component Building Analysis y Btuh Job: FS2B1 Walls - 13333 31.3 Date: 7/22116 23.9 8615 20.2 Entire House 0.8 By. Vince Syrarn. 0.1 Ceilings Modern Plumbing Heating and Electric 2559 6.0 xra°o°�M 1.5 2312 5.4 Infiltration 3939E 240 N, Rigby, Itl 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modemphe.com 4054 9.5 Ducts 0 0 Project• 0 0 For: Cody Puzey 6348 14.9 Ventilation 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Adjustments 0 Phone: 208-529-2116 Total 42588 100.0 Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Dailyrange (°F) - 34 (H ) Method Simplified Wi;tbulb (°F) - 60 Construction quality Semi -tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 4.5 13333 31.3 Glazing 23.9 8615 20.2 Doors 0.8 32 0.1 Ceilings 1.5 2559 6.0 Floors 1.5 2312 5.4 Infiltration 1.9 4054 9.5 Ducts 0 0 Piping 0 0 Humidification 6348 14.9 Ventilation 5335 12.5 Adjustments 0 Total 42588 100.0 Cooling Component Btuh/fta Btuh % of load Walls 0.3 799 4.8 Glazing 27.1 9766 58.5 Doors 0.2 8 0.0 Ceilings 0.8 1414 8.5 Floors 0 0 0 Infiltration 0.2 393 2.4 Ducts 0 0 Ventilation 983 5.9 Internal gains 3320 19.9 Blower 0 0 Adjustments 0 Total 16682 100.0 Latent Cooling Load = 0 Btuh Overall U -value =0.053 Btuh/fF °F Data entries checked. WY1ghtSO2016-Jul-22 15:20:41 f!' Right -Suite® U niversal 201717.0.03 RSU20477 Page 1 ...ofMare\Kartchner\Jamestown\FS2Bijamestowarup Calc=MJB Front Doorfaces: E Com onent Constructions Job: FS2131 p Dace: 712211611ns Entire House By: vine Byram ° Modern Plumbing Heating and Electric anlln0. it n Irloaing 3939 E 240 N, Rigby,.ld 83442 Phone: 208-745-7021 Fax: 208-7457329 Email: Vince@modemphe.com • •4 Lela For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 -)0sirin Conditic Location: 16 Indoor: Heating Cooling Idaho Falls, ID, US 23.9 indoor temperature (°F) 70 75 Elevation: 4741 ft area Design TD (°F) 76 14 Latitude: 44°N Clg HTM Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib), 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: 24.3 3295 Dailyrange (°F) - 34 (H) Method Simplified 0.300 Wet bulb (°F) - 60 Construction quality Semi -tight 21.0 Wind speed (mph) 15.0 7.5 Fireplaces 0 board int fnsh, 2"x6" wood frm, 16" o.c. stud Partitions (none) Windows 61 Q 61 C; 6.67 It head ht Doors metal: Door, mtl pur core type Ceilings ne 16 0.320 0 24.3 385 23.9 379 Gain Construction descriptions or area U -value Insul R Htg HTM Loss Clg HTM 10 0.320. M BWbIW-"F M'F/Btm BluhN Btuh Btuhffl Btuh Walls 0 24.3 3295 30.4 4118 se 60 0.300 12F-Osw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum ne 346'. 0.065 21.0 4.94 1708 0.47 164 board int fnsh, 2"x6" wood frm, 16" o.c. stud a 19 0.065 21.0 4.94 92 0.47 9 2189 se 426 0.065 21.0. 4.94 2105 0.47 202. 22.4 s 19 0.065 21.0 4.94 92 0.47 9 9766 sw 362 0.065 21.0 4.94 1787 0.47 172 my 470 0.065 21.0 4.94 2320 0.47 223 all 1641 0.065 21.0 4.94 8105 0.47 779 151313-Owc-8: Bg wall, heavy dry or light damp soil, 2"x4" wood int firm, ne 294 0.049 13.0 3.89 1143 0.02 5 concrete wall, r-13 cav ins, 8" thk, 1/2" gypsum board int fnsh se 473 0.049 13.0 3.72 1757 0.00 2. sw 234 0.049 13.0 4.10 958 0.03 6 nw 349 0.049 13.0 3.93 1370 .0.02 7 all 1349 0.049 13.0 3.88 5228 0.02 20 Partitions (none) Windows 61 Q 61 C; 6.67 It head ht Doors metal: Door, mtl pur core type Ceilings ne 16 0.320 0 24.3 385 23.9 379 the 20 0.300 0 22.8 456 22.4 448 e 10 0.320. 0 24.3 233 34.4 330 as 136 0.320 0 24.3 3295 30.4 4118 se 60 0.300 0 22,8 1368 28.5 1710 S 10 0.320 0 24.3 233 18.9 181 nw 90 0.320 0 24.3 2189 23.9 2152 nw 20 0.300 0 22.8 456 22.4 448 all 361 0.300 0 23.9 8615 27.1 9766 nw 42. 0.010 6.7 0.76 32 0.19 8 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 tail ins, 1/2" 1683 0.020 50.0 1.52 2559 0.84 1414 gypsum board int fnsh 2016Jul-2215:20:41 `M�rFWrIght".501ft' Right -Suite® Universal 201717.0.03RSU20477 Pagel s...oftware\KartchnenJamestownlFS2Btjameslown.rup Ca1c=MJ8 Front Uoorfaces: E Floors 21A -32c: Bg floor, heavy dry or light damp soil, 8' depth, carpet fir fnsh 1396 0.020 0 1.52 2121 0 0 125 0.020 0 1.52 190 0 0 all 1521 0.020 0 1.52 2312 0 0 2016 -Jul -2215:20:41 ,Q wrightsoft" Rig ht -Suite® U niversa1201717.0.03 RSU20477 Page /�A...oftware\Kartchner'Jamestown\FS2Bijamestown.rup Calc=MJ8 Front Ooorfaces:E Project Summary Job: FS2BI 7 Date: 7/221111 6 Entire House By: Vince Byrann ger°� a orff9 Modern Plumbing Heating and Electric 3939 E 240 N. Rigby, Id 83442 Phone: 208-7457021 Fax: 2013-745-7329 Email: Vince@modemphe.com Project Information For: Cody Puzey 3758Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Notes: Design Information Weather: Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TO 76 OF Heating Summary Structure 30905 Btuh Ducts 0 Btuh Central vent (76 cfm) 5335 Btuh Humidification 6348 Btuh Piping 0 Btuh Equipment load 42588 Btuh Infiltration 15681 Btuh Idaho Falls, ID, US Method Simplified Construction quality Semi -tight Fireplaces 0 Heating Cooling Area (ftp) 3079 3079 Volume (ftp 18229 18229 Air changes/hour 0.19 0.10 Equiv. AVF (cfm) 58 30 Heating Equipment Summary Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 %d Moisture difference -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 15699 Btuh Ducts 0 Btuh Central vent (76 cfm) 983 Btuh Blower 0 Btuh Use manufacturer's data n AHRI ref 2002182 Rate/swing multiplier 0.94 Equipment sensible load 15681 Btuh Latent Cooling Equipment Load Sizing Structure 254 Btuh Ducts 0 Btuh Central vent (76 cfm) -1366 Btuh Equipment latent load 0 Btuh Equipment total load 15681 Btuh Req. total capacity at 1.00 SHR 1.3 ton Cooling Equipment Summary Make Amana Make Amana Trade Amana Trade Amana Model GMH950703BX Cond GSX13024 AHRI ref 2002182 Coil CA*F3030 AHRI ref 4886848 Efficiency 95 AFUE Efficiency 11.5 EER, 14 SEER Heating input 69000 Btuh Sensible cooling 17700 Btuh Heating output 52960 Btuh Latent cooling 0 Btuh Temperature rise 67 OF Total cooling 17700 Btuh Actual air flow 859 cfm Actual air flow 859 cfm Air flow factor 0.028 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0.70 in H2O Static pressure 0.70 in H2O Space thermostat Load sensible heat ratio 1.00 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2016-2215Page ''-- wrightsOft• versa Right -Suite® U nil 201717.0.03 RSU20477 Page 7 ...oflware\KartchnerWameslown\F52B7jameslown.rup Cale =MJB Front Door faces: E Test for Adequate Exposure Diversity Hourly Glazing Load eau / Hou,ly / M..p / ADW Maximum hourly glazing load exceeds average by 23.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2016 -Jul -2215:20:41 ��'+4+-• wrlghtSoft' Right -Suite® Universal 2017 17.0.03 RSU20477 Page .94it.0i 4...oftware\Kartchner\Jamestown\FS2B1 jamestown.mp Calc =MJB Front Door faces: E AED Assessment Job: FS2B1 Date: 7/22/16 Entire House By: Vince Byram ModernPlumbing Heating and Electric tl.uip;,. it nir noing 3939 E 240 N. Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@mcdemphe.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Dailyrange (°F) 34 (H ) VVet bulb (°F) 60 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load eau / Hou,ly / M..p / ADW Maximum hourly glazing load exceeds average by 23.7%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2016 -Jul -2215:20:41 ��'+4+-• wrlghtSoft' Right -Suite® Universal 2017 17.0.03 RSU20477 Page .94it.0i 4...oftware\Kartchner\Jamestown\FS2B1 jamestown.mp Calc =MJB Front Door faces: E Right -J® Worksheet Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax 208-745-7329 Email: Vnce@modemphe.com Job: F521211 Date: 7122116 By: Vince Byram 1 Room name Entire House Room3 2 Exposed wall 355.3 it 28.3 R 3 Room height 9.5 It d 9.0 ft heat/cool 4 Room dimensions 1.0 x 178.4 fl 5 Room area 3079.0 ft2 178.4 fl' T Ty Construction U -value Or HTM I I Area (ft')Load I I Area ft2 I Load number SIX (Bt uh/fl2) or .perimeter (H). (Btuh) or perimeter (H) (Btuh) Heat Cool Gross Heat Cool Gross N/P/S Heat Cool 6 41J : 12F Osw 0.065 ne 4.94 0.47 362 346 1708 164 0 0 0 0. G 61C 0.320 ne 24.32 23.91 16 0 385 379 0 0 0 0. 4jJ 151313-0wc-B 0.093 ne 3.89 0.02 314 294 1143 5 152 152 620 4 `G 61C 0.300 ne 22.80 22.42 20 0 458 448 0 0 0 0 71 IN 12F -Ow 0.065 a 4.94 0.47 28 19 92 9 0 0 0 0 ---G61C x0.320 a ':.24.32 3442 :. 10 0 233 330 '. 0 0 1.0 _0 U+J 12F.Osw 0.065 se 4.94 0.47 562 426 2105 202 0 0 0 0 L -C 61C 0.320 se 24.32 30.39 136 0 3295 4118 0 0 0 0 UPJ 15B130wc-B 0.093 se 3.72 000 533 473 1757 2 104 84 283 0 L --G 61C 0.300 se 22.80 28.49 60 0 1368 1710 1 20 0 .456 570. l/�! 12F-Osw 0.065 s 4.94 0.47 28 19 92 9 0 0 0 0 `C 61C 0.320 s 24.32 1888 10 0 233 181 0 0 0 0 W 12FOsw 0.065 sw 4.94 047 362 362 1787 172 0 0 0 0 W 151313 -Ow" 0.093 sw 4.10 0.03. 234 234 958 6 0 0 0 0 121`-Osw 0.065 nw, 4.94 0.47 602 - 470 2320 223 0 0 0 0 0.320 nw, 24.32 23.91 90 0 2189 2152 0 0 0 0 ���61C ---. metal 0.010 nw, 0.76 0.19 42 42 32 8 0 0 0 0 Y+! 15B73-Owc-8 0.093 nw, 3.93 0.02 369 349 1370 7 0 0 0 0 �G 61C 0.300 nw, 22.80 22,42 20 0 456 448 0 0 0 0 C 166-50ad 0.020 1.52 0.84 1683 1683 ..2559 1414 0 0 '0 ''D F 21A -32c 0.020 1.52 0.00 1396 1396 2121 0 178 178 271 0 IF 21A -32c. . ;0,020 1.52 0.00 ' 125 125 190 0 0 0 0 'D fi c)AED excursion 0 10 Envelope loss/gain 28850 11988 1630 584 12. a) Infiltration 4054 393 55 5 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 4 9200 0 Appliances/other .2400 0 Subtotal (lines 6 to 13) 30905 15699 H 1685 589 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30905 15899 1685 589 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Aotae9u 905691 308591 758591 18471 5321 I I edl(oad cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ft- wricghteOft" 2016 -Jul -2215:20:41 Rig ht -Suite® U niversal 2017 17.0.03 RSU20477 Page 1 ...oftware\KartchnerlJamestown\FS2B1 jamestowo.rup Calc =We Front Door faces: E Right -39) Worksheet Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax 208-745-7329 Email: Vince@modemphe.com Job: FS2B1 Date: 7122116 By: Vince Byram 1 Room name Room4 Room5 2 Exposed wall 27.2 ft 9.2 ft 3 Room height 9.0 ft heat/cool 9.0 it heat/cool 4 Room dimensions 11.2 x 16.0 It 9.2 x 13.3 ft 5 Room area 178.7 ft' 122.2 fP Ty Construction U -value Or HTM Area (f P) Load Area (f P) Load number (Btuh/fFT (Btuh/ft) or .perimeter (ft).. (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS j Heat Cool Gross N/PIS Heat Cool 8 12F-Osw 0.065 ne 4.94 047 0 0 ` 0 0 0 0 - 0 0 . G 61C ....0,320 ne 24.32 23.91 0 0 0 0 0 0 0 /0 W 15B130wC-8 0.093 ne 3.89 0.02 144 124 448 0 0 0 0 : 0 61C 0.300 ne 22.80 22.42 20 0 456 448 0 0 0 0 11" 12P 0sw 0.065 a 4.94 :0.47 0 0 0 0 0 0 0 0 61C 0.320 a '24.32 34.42 0 0 -0 0 0 : 0 0 :0 �12F-Osw 0.065 se 4.94 0.47 0 0 0 0 0 0 0 0 G 61C 0.320 se 24.32 30.39 0 0 0 0 0 0 0 0 y/ 15813-0wo-8 0.093 se 3.72 0.00 0 0 0 0 83 83 338 2 L --G 61C 0.300 as .. 22.80 28.49 '.'0 0 '0 0 0 0 0 . '0 lqJ 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 �G 61C 0.320 a 24.32 18.88 0 0 0 0 0. 0 0 0 W 12F-Osw 0.065 sw 4.94 047 .` 0 0 -0 0. 0 - 0 10. 0 W 15813-Owc-8 0.093 sw 4.10 0.03 0 0 '0 0 0 0 0 0 W 12F -Om 0.065 nw 4.94 047 0 0 0 0 0 0 0 0 L1I�G 61C 0.320 nw 2432 23.91 0 0 0 0 0 0 0 0 �-D metal 0.010 nw 0,76 019 0 0 0 0 0 0 0 0 W 151313-0wa8 0.093 nw 3.93 0.02 101 .101 412 3 0 0 0 0 61C 0.300 nw 22.80 22,42 0 0 0 0 0 0 0 0 C 166-50ad 0,020 '1.52 084 0 0 _0 s0 0 0 0 0. F 21A -32c 0.020 - 1.52 0.00 179 179 272 0 122 122 186 0 F 21A -32c 0.020 1.52 0.00 0 0 '.0 '0 : 0 0 0 0 6 c)AED excursion -46. 0 Envelope loss/gain 1588 405 524 2 12. a) Infiltration 52 5 18 2 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1640 410 541 3 Less external load 0 00 0 Less transfer 0 0 0 0 Retlistribution 0 0 0 0 14 Subtotal 1640 410 541 3 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Aroom load otae9uired 1E48I 10 4221 41 5151 31 (c m) I I I 1 I _ O Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wrightshaft` Right -Suited Universa1201717.0.03 RSU20477 2016 -Jul -2215:20:41 ...oftwareWartchnerWamestownTS2131)amestown.rup Calc=MJ8 Front Door faces: E Paget Right -JO Worksheet o Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modemphe.com Job: FS2B1 Date: 7122116 By: Vince Byram 1 Room name Room7 Room8 2 Exposed all 76.2 it 20.2 it 3 Room height 9.0 it heat/cool 9.0 it heat/cool 4 Room dimensions 1.0 x 744.4 fl 1.0 x 171.9 H 5 Room area 744.4 ft2 171.9 ft2 Ty Construction U -value Or HTM I Area (ft2) I Load. Area (ft2) I Load number (Btuh/ftk'F� (Btuh/f6) or perimeter (it) (Binh) or perimeter (fl) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6l�12F-Osw G .0.065 ne '4.94 r 1 047 0 0 ` 0 0 0 0 0 0 61C 0.320 ne ..24.32 23.91 0 0 0 0 0 0 0 0 U+/ 15813-Ow.8 0.093 ne 3.89 0.02 0 0 0 0 18 18 74 0 �G 61C 0.300 ne 22.80 22.42 0 0 0 0 0 0 0 0 11 12F Osw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 61C .0.320 a 24.32 34.42 0 0 '0 0 0 0 0 0 T72F-Osw 0.065 as 4.94 0.47 0 0 0 0 0 0 0 0 G 81C 0.320 as 24.32 30.39 0 0 0 0 0 0 0 0 15813-0wo-8 0.093 as ' 3.72 0.00 347 ` 307 1136 0 0 ` 0 s 0 0 61C 0.300 se 22.80 28.49 40 0 .912 1140 " 0 0 ' 0 0 t_G 72F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 61C. 0.320 s .24.32 18.88 0 0 0 0 0 0 0 0 w 42F-Osw 0.065 sw 4,94 0.47 0 0 :0 0 0 0 - 0 ". 0 w 15613-0wc-8 0.093 sw 4.10 0,03 165 165 676 4 69 69 283 2 12F Osw 0.065 nor4.94 0.47 0 0 :.0 0 0 0 ` 0 0' 61C 0.320 nor 24.32 23:91 0 0 0 0 0 0 0 0 D metal 0.010 my 0)76 0.19 0 0 0 0 0 0 0 '.0 W� 15813-13wo-8 0.093 nw 3.93 0.02 174 174 713 5 95 75 246 0 `C 61C 0.300 my 22.80 22,42 0 0 0 0 20 0 456 448 C 1189-50ad 0.020 1.52 0.84 0 0 0 '0 0:. 0 0 0. F 21A -32c 0.020 - 1.52 0.00 744 744 1132 0 172 172 261 0 F 21A 32c 0.020 1.52 0.00 0 0 0 _ 0 O f 0 0 '0 8 c) AED excursion19 127 Envelope loss/gain 4568 1188 1319 577 12 a) Infiltration 147 14 394 b) Roomventilmlon 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal (lines 6 to 13) 4715 1182 1358 581 Less external load 0 0 00 Less transfer 0 0 0 Redistribution 0 0 0 J581 14 Subtotal 4715 1182 1358 15 Duct loads -0% 0% 0 0 -0% 0% 0 load 41311 715 1358 5321 Arrequrd(cfm) ( I I 651 1 I 381 Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. 4F ek Right-Suite®Universa1201777.0.03 RSU20477 201&Jul-2215:20:41 A...oftware\KartchnerWameslown\F52B1 jameslown.rup Calc =MJ8 Front Door faces: E Page3 Right -J® Worksheet Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 20B-745-7021 Fax: 208-745-7329 Email: Vince@modemphe.com Job: FS2B1 Date: 7122116 By: Vince Byram 1 Room name Rcom10 Roomll 2 Exposed wall 29.5 ft 5.2 ft 3 Room height. 10.0 ft heat/cool 10.0 ft heat/coal 4 Room dimensions 1.0 x 262.1 ft 9.7 x 5.2 ft 5 Room area 262.1 ft2 49.9 fl' T y Construction U -value Or HTM I I Area fl' I Load I Area ft2 I Load number (Btuh/fl2-T (Bl uh/f N) or perimeter (tt). (Bluh) or. perimeter (ft) (Stub) Heal I Cool Gross N/P/S Heat ' Cool Gross N/P/S Heat Cool 6 12F Osw 0.065 re 4.94 091 157 157 974 74 52 38 787 17 G 01C 0.320 ne 24.32 23.92 0 0 0 0 16 0 385 379 t 751373-Owc-13 0.093 re 3.89 .0.02 0 0 0 0 0 0 0 0 -G 61C 0.300 ne22.80 22.42 0 0 0 0 0 0 0 0 17 721` 0,085 a-Osw a 4.94 0.47 0 0 0 0 0 0 - 0 0 �Ca 61C 0.320 a <: 24.32 34.42 ' 0 ` 0 0 : a " 0 0 0 0. Ur! 12F-Osw 0.065 as 4.94 0.47 138 108 535 51 0 0 0 0 --G 61C 0.320 as 24.32 30.39 30 0 730 912 0 0 0 0 Yj! L 151313 0wo-8 0.093 as 3.72 - 0.00 0 0 0 0 0 0 0 0 61C 0,300 se 22.80 28.49 0 -.. 0 0 0 0 0 0 : 0 -G t 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 -G 61C 0.320 s 24.32 18.88 0 0 0 0 0 0 0 0 w 12F-0sw 0.065 sw 4.94 0.47 0 0 '0 0 0 0 -0 0 w 151313-Owo-13 0.093 sw 4.10 0.03 0 0 0 0 0 0 0 0 -Om 0.065 nw 4.94 0.47. 0 0 0 0 0 0 0 0 L12F 81C 0.320 nw 24.32 23.91 0 0 0 0 0 0 '0 0 metal 0.010 nw '.0.76 '0.19 0 0 0 0 0 0 0 0 W, 15813-Owc-8 0.093 nw 3.93 0.02 0 0 0 0 0 0 0 0 L --G 61C 0.300 nw 22.80 22.42 0 0 0 0 0 0 0 0 C 165 50ad 0,020 1.52 0.84 262 262 398 220 50 50 76 42 F 21A -32c 0.020 1.52 0.00 0 0 0 0 0 0 0 0 F 21A 32c 0.020 - 1..52 0.00 14 14 22 0 2 2 3 0 61 c)AED excursion: 79 .46 Envelope loss/gain 2459 1179 841 392 12 a) Infiltration 568 55 100 10 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3027 1694 740 401 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3027 1694 740 401 15 Duct loads -0% OYo 0 0 -0% 0% 0 0 load 30841 94 78931 72101 401 11 Auteequir d (c m) 1 1 1 1 1 � • Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed. sr- 'r' wrightsoTt' 41 Rig ht -Su ite® U my ersal 2017 17.0.03 RSU 20477 2076-Jul-2215Pa:e4 "'6'G'...oftware\KartchnerlJamestown\FS2B1 jameslown.rup Calc =MJ8 Front Door faces: E g Right -J® Worksheet Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modemphe.com Job: FS281 Date: 7122116 By: Vince Byram 1 Room name Room12 Rooml3 2 Exposed wall 24.5 it 21.3 f 3 Room height. 10.0 it heathmol 10.0 it heaVcool 4 Room dimensions 1.0 x 144.6 f 1:0 x 163.1 it 5 Room area 144.6 fix 163.1 ft' Ty Construction U -value Or I HTM Area (ft-) I Load Area (ft-) I Load number (Bluh/ft;T (Bluh/W) or perimeter (f). (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V"12F-Osw 0.065 ne 4.94 0.47 133 133 659 63 20 20 99 9 61C 0.320 ne 24.32 23.91 0 0 0 0 '. 0 0 _' 0 0 IN 15B13 -0.c-8 0.093 ne 3.89 0.02 0 0 0 0 0 0 0 0 L -.G 61C 0.300 ne 22.80 22.42 0 0 0 0 0 0 0 0 11 V"G12F -Om 0.065 a 4,94 .0.47 0 0 ' 0 0 0 0 0 0 61C 0.320 a 24.32 34.42 0 0 : 0 0 0 0 0 0 UPJ 12F-Osw 0.065 as 4.94 0.47 0 0 0 0 0 0 0 0 L --G 61C 0.320 as 24.32 30.39 0 0 0 0 0 0 0 0 l�J 15B130wc-8 0.003 as 3.72 000 0 0 0 0 0 0 0 0 I ---G '61C 0.300 se 22.80 2849 0 0 0 0 0 0 1 0 0 lr�J 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 L --G 61C' 0.320 a 24.32 18.88 0 0 0 0 0 0 a 0 w 12F-Osw 0.065 sw 4.94 0.47 0 0 0 0 - 80 - 80 '.395 - 38 Vv 15813-Owc-8 0.093 sw 4.10 0.03 0 0 0 0 0 0 0 0 l 12F Oaw 0.065. my 4.94 .0.47 112 82 403 39 113 83 412 40 81C 0.320 nw 24.32 23:91 30 0 730 717 30 0 730 717 D metal 0.010 nw 0.76 0.19 0 0 0 0 0 0 0 0 N�/ 15B13-Owc-8 0.093 nw 3.93 0.02 0 0 0 0 0 0 0 0 t -G BIC 0.300 nw 22.80 22.42 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 ':' 1.52 0.84 145 145 220 121 163 163 248 137. F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 F 21A -32c 0.020 - 1.52 0.00 12' ". 12 '.. 18 0 12 12 ,.. 18 -.0 6 c) AED excursion 1 149 Envelope loss/gain 2029 1089 1901 1090 12 a) Infiltration 472 46 411 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) i 2501 1365 2313 1360 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2501 1365 2313 1360 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 250101 13715 23641 13741 A! requiredload (cfm) I 1 51 I I Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed. -Pk Wr1phYS0f6" Right -Suite® Universal 2017 17.0.03 RSU20477 2016-Jul-2215Pag20 e Page 5 ...ofware\KartchnerlJameslown\F52B1 jameslown.rup Calc = MJS Front Door faces: E Right -J® Worksheet o Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, If 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince®modemphe.com Job: FS2B1 Date: 7122116 By: Vince Byram 1 Room name Room14 Room15 2 Exposed wall 8.5 ft 86.3 It 3 Room height 10.0 ft heaticool 10.0 It heat/cool 4 Room dimensions 8.5 x 10.3 ft 1.0 x 863.9 ft 5 Room area 87.8 ft' 863.9 ft2 T Y Construction U -value Or HTM I I Area fP I Load I Area ft' Load number (Btuhfft'-°Fp (Btuh/fl') or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool +II {II f 6VL-12F-Osw 0.065 ne 4:94 0.47 0 0 0 0 '0 0 - 0 0 G 61C 0.320 ne 24.32 23.91 0 0 0 0 0 0 0 ,0 l�! 15B13-0wc-8 0.093 ne 3.89 0.02 0 0 0 0 0 0 0 0 �G 61C 0.300 ne 22.80 22.42 0 0 0 0 0 0 0 0 11 Ur! 12F Osw 0.065 a 4.94 0.47 0 0 0 0 28 19 - 92 9 L --G 61C0.320 a .. " .24.32 34.42 0 0 ,0 0 10 0 233 ....330 VL 12F-0sw 0.065 as 4.94 0.47 85 70 346 33 338 248 1224 118 -G 61C 0.320 as 24.32 30.39 15 0 365 456 91 0 2201 2750 �/! 15813-Owc-8 0.093 se 3.72 0.00 0 0 0 0 0 0 0 0 �-G 61C 0,300 se , 22.80 28.49 0 ,. 0 0 0 0 0 0 0 y! 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 28 19 82 9 `G 61C 0.320 s 24.32 18.86 0 0 0 0 10 0 233 181 W '- 12F-0sw 0.065 sw 4.94 0.47 0 0 0 0 ] 197 J. 197 972 "93 W 15613-Owc-8 0.093 sw 4.10 0.03 0 0 D 0 0 0 0 0 Osw 0.065 nw 4.94 0.47 0 0 0 0 272 230 1135 109 L12F 61C 0.320 my 24.32 23.91 0 0 0 0 0 0 0 0 metal 0.010 nw 0.76 0.19 0 0 0 0 42 42 32 8 4)J 15873-Owo-8 0.093 nw 3.93 0.02 0 0 0 0 0 0 0 0 �--G 61C 0.300 nw 22.80 22.42 0 0 0 0 0 0 0 0 C 16B-50ad 0.020 - 1.52 0.84 88 88 134 74 864. 864 '..1313 726. F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 0 0 0 0 F 21A 32c ;0.020 1.52 0.00 6 6 9 0 72 72 109 >: 0 61 c) AED excursion -5 457 Envelope loss/gain i 853 558 1 7636 3876 12 a) Infiltration 164 16 i6fi3 181 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants Qa 230 0 0 0 0 Appliances/other 0 2400 Subtotal (lines 6 to 13) 1018 574 9300 6437 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1016 574 9300 6437 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 room load 10 5. 91 61Ao I I I 281 311 I I 258 352Wreqdiim Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -liWrightsof!' 2016 -Jul -22 15:20:41 Right-Suite®Universal 201717.0.03 RSU20477 ' `'...oftware\KarlchneNamestownTS2Bl jamestown.rup Calc =MJ8 Front Door faces: E PageB Right -JO Worksheet Entire House Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 20B-745-7021 Fax: 208-7457329 Email: Mnce@modernphe.com Job: FS2B1 Date: 7/22116 By: Vince Byram 1 Room name Room16 2 Exposed wall 19.0 It 3 Room height 10.0 It heat(coel 4 Room dimensions 10.5 x 10.7 It 5 Room area 112.0 W Ty Construction U -value Or HTM I Area (ft-) I Load I Area Load number (13tuh/UPT (Btuh/fP) or perimeter (ft). (Btuh) or perimeter Heat Cool Gross WP/S Heat Cool Gross WP/S Hee, Cool 6 y! 12F Osw 0.065 ne 4.94 0.47 0 0 -Q 0 �G 61C 0.320 ne 24.32 23.91 0 0 0 0 15B130wc-8 0.093 ne 3.89 0.02 0 0 0 0 T --G 61C 0.300 ne 22.80 22.42 0 0 0 0 11 12FOsw - 0.065 a 4.94 047 ' 0 0 0 0 I-G61C 0.320 a 24.32 3442 0 0 '0 0 V 12F-0sw 0.065 as 4.94 0.47 0 0 0 0 1 ^- 61C 0.320 se 24.32 30.39 0 0 0 0 lqJ 15B130wc-8 0.093 as 3.72 0.00 0 0 0 0 I --G 61C 0.300 as 22.80 28,49 0 0 0 0 lM 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 �--G 61C .0.320 s 24.32 18.88 0 0 0 0 W 12F-0sw 0.065 sw - 4.94 0.47 85 85 :. 420 40 W 151313-0wo-8 0.093 sw 4110 0.03 0 0 '.0 0 12F 0sw 0.065 nw '4.94 0.47 105 75 370 '. 36 61C 0.320 nw 24.32. 23.91 30 0 730 -717 metal 0.010 nw 0.76 '. - 0.19 0 ' 0 '0 0 T151313-Owc-13 0.093 nw 3.93 0.02 0 0 0 0 �G BIC 0.300 nw 22,80 22.42 0 0 0 0 C 166 50ad 0.020 - 1.52 0.84 112 112 :170 94 F 21A -32c 0.020 - 1.52 0.00 0 0 0 0 F 21A 32c 0.020 - 1.52 0,00 8 8 12 '.0 61 c) AED excursion 181 Envelope loss/gain 1702. 1068 12 a) Infiltration 366 35 b) Roomventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal (lines 6 to 13) 2068 1104 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2068 1104 15 .Duct loads -0% 0% 0 0 '1 20581 1 Aalaequir d(cfm) 1 1 1 6041 1 1 1 Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. wri htsaft- 2016 -Jul -22 15:20:41 AA- 4 Right -Suite® Universal 2017 17.0.03 RSU20477 Pagel ...oftware\KahchnerVamestown\FS2Bliameslown.rup Calc=MJ8 Front Doorfaces: E 113 main Job #: FS2B1 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 20M29-2116 Modern Plumbing Heating and 3939 E 240 N Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Vince@modernphe.com Scale: 1 : 100 Page 1 Rig ht-Sui[e® Universal 2017 17.0.03 RSU20477 2016 -Jul -22 15:21:02 13 Basement Job#:FS2B1 Modern Plumbing Heating and Electric Scale: 1 : 100 Performed by Vince Byram for: Page 2 Cody Puzey 3939 E 240 N Right-SuiteU2sa12017 3758 Yellowstones Hwy Rigby, Id 83442 17.0.033 RSU20477 Idaho Falls, Id 83401 Phone: 208-5232116 Phone: 208-745-7021 Fax: 208-745-7329 2016 -Jul -2215:21:03 Vince@modernphe.com ...er\Jamestown\FS2B1 jamestown.mp Duct System Summary Job: 71 2221/71 Date: 716 Entire House By: Vince Byram ° 0.'.6Modern Plumbing Heating and Electric 3939 E 240 N, Rigby, Id 83442 Phone: 208-745-7021 Fax: 208-745-7329 Email: Vince@modemphe.com Project Information For: Cody Puzey 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Name (Btuh) Htg (Cfm) Heating Cooling External static pressure 0.70 in H2O 0.70 in H2O Pressure losses 0.35 in H2O 0.35 in H2O Available static pressure 0.35 in H2O 0.35 in H2O Supply /return available pressure 0.163 / 0.187 in H2O 0.163 / 0.187 in H2O Lowest friction rate 0.079 in/100ft 0.079 in/100ft Actual air flow 859 cm 859 cfm' Total effective length (TEL) 21 443 ft 0.085 SupplyDetail Table ShMt 31.0 Name (Btuh) Htg (Cfm) Clg (cdm) Design FIR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Room10 c 1694 84 93 0.082 6.0 OX0 ShMt 47.8 150.0 st2A Rooml1 c 401 21 22 0.085 6.0 'OX0 ShMt 31.0 160.0 st2A Rcom12 c 1365 70 75 0.083 6.0 Oxo ShMt 45.5 150.0 st213 Rooml3 c 1360 64 74 0.098 6.0 0x0 ShMt 36.0 130.0 st2 Room -14 c 574 28 31 0.088 6.0 OX0 ShMt 35.2 150.0 st2 Room15 c 1287 52 70 0.099 6.0 .0x0 ShMt 25.2 140.0 st1 Rooms&A c 1287 52 70 0.086. 6.0 ..'. Ox ShMt 30.7 1.60.0 st2 Room15-B c 1287 52 70 0.101 6.0 Oxo ShMt 36.4 125.0 st1B Room15-C c 1287 52 70 0.115 6.0 0x0 ShMt 11.8 130.0 st1 Room15-D c 1287 52 70 0.089 6.0 0x0 ShMt 17.7 165.0. st2 Room16 c 1104 57 60 0.087 6.0 OX0 ShMt 11.8 175.0 st2 Room3 h 1685 47 32. 0.087 6.0 0x0 'ShMt 47.6 140.0 st2A Rocm4 h 1640 46 22 0.091 6.0 Oxo_ ShMt 43.7 135.0 st2C Rooms h 541 15 0 0.094 6.0 OX0 ShMt 34.0 140.0 st2 Rocm7 h 2358 66 32 0.083 6.0 OX0 ShMt 22.2 175.0 st2 Room7-A h 2358 66 32 0.093 6.0 0x0 ShMt 35.1 140.0 st1A RoomB h 1358 38 32 0.079 6.0 0x0 ShMt 36.2 170.0 st2A sr. 2010-Ju1-2215:20:42 u. wi'IghtSOW Right-Suiteln Universal 2017 17.0.03 RSU20477 Pagel A ...oftwareWanchneNamestownTS2B1 jameslown.rup Calc =MJB Front Door faces: E Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (dm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1B Peak AVF 52 70 0.101 106 5.1 8 x 12 ShtMetl st1A st1A Peak AVF 117 103 0.093 176 6.3 8 x 12 ShtMetl st1 st1 Peak AVF 221 244 0.093 365 8.2 8 x 12 ShtMetl 74 st2 Peak AVF 638 615 0.079 958 12.2 8 x 12 ShtMetl 0x0 st2A Peak AVF 304 276 0.079 457 9.3 8 x 12 ShtMetl st2 st26 Peak AVF 115 97 0.083 173 6.4 8 x 12 ShtMetl st2A st2C Peak AVF 46 22 0.091 68 4.4 8 x 12 ShtMetl st2B Return Branch Detail Table Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb2 0x0 15 0 94.0 0.199 48 2.5 3.25x14 10x9 SJSp rt1 rb3 0x0 70 75 162.7 0.115 236 5.1 3.25x14 10x9 SJSp rt1A rb4 0x0 64 74 164.2 0.114 235 5.1 3.25x14 10x9 SJSp rt1A' rb5 0x0 161 201 109.5 0.171 637 6.8 3.25x14 10x9 SJSp rt1 rb6 0x0 133 146 126.0 0.148 462 6.2 3.25x14 10x9 SJSp rt1 rb7 0x0 38 32 156.2 0.120 119 3.9 3.25x14 10x9 SJSp rt1A rb8 Oxo 46 22 224.7 0.083 144 4.5 3.25x14 10x9' SJSp rt1C rb9 0x0 47 32 236.3 0.079 148 4.6 3.25x14 10x9 SJSp rt1B rb1' 0x0 286 276 62.0 0.302 906 6.9 3.25x14 10x9 SJSp Return Trunk Detail Table 2016 -Jul -22 15:20:42 wrightsoft' Rig hl-Suite®Unlversal201717.0.03RSU20477 Page ...oflwarelKartchnerllamestown\FS2B11amestown.rup Calc=MJO Front Door faces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk 111 Peak AVF 573 583 0.079 525 13.1 8 x 20 ShtMetl rt1A Peak AVF 264 236 0.079 396 8.8 8 x 12 ShtMetl 01 rt1B Peak AVF 92. 55 0.079. 139 5.9 8 x 12 ShtMetl rt1A rt1C Peak AVF 46 22 0.083 68 4.5 8 x 12 ShtMetl rt1B 2016 -Jul -22 15:20:42 wrightsoft' Rig hl-Suite®Unlversal201717.0.03RSU20477 Page ...oflwarelKartchnerllamestown\FS2B11amestown.rup Calc=MJO Front Door faces: E