HomeMy WebLinkAboutINSPECTION SUMMARY - 17-00073 - 52 College Ave - Restaurant ConsultationPermit Inspection Summary Permit Status of (Open) as of Report Date: 06/16/2017 9:41 am Permit Details Permit Number: 17-00073 52 College Ave - Resturaunt consultation 52 College Ave Consultation case Permit Issued Date: Permit Inspection Statistics Total Inspections Completed: Total Inspections Passed: Inspection Pass Rate Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type If total occupant load will ever be over 49 (including employees) then 2 exits are required (locations are subject to limitations). Exiting shall not pass through intervening rooms or areas (including an "emergency exit" from basement) unless meeting certain conditions. Inspector Comments: Public restroom is required when space is intended for public utilization (dine-in). Separate restrooms for each sex is required when total occupant load is more than 15. Inspector Comments: An accessible route shall be maintained to accessible restroom.Inspector Comments: Cooking appliances used for commercial purposes require a type 1 or type 2 hood as designated by the Mechanical Code. A hood may not be required only where a listed appliance has been approved for commercial use without a hood. Inspector Comments: 02/24/2017COMPLETEDQuinton OwensBuilding Inspector Consultation Sprinklers are required in assembly occupancies intended for food and drink consumption where the occupant load is over 100 or is not on the level of exit discharge (ground level). No partial sprinkler systems are currently allowed per city ordinance. Inspector Comments: