If total occupant load will ever be over 49 (including employees) then 2 exits are
required (locations are subject to limitations). Exiting shall not pass through
intervening rooms or areas (including an "emergency exit" from basement)
unless meeting certain conditions.
Inspector Comments:
Public restroom is required when space is intended for public utilization (dine-in).
Separate restrooms for each sex is required when total occupant load is more
than 15.
Inspector Comments:
An accessible route shall be maintained to accessible restroom.Inspector Comments:
Cooking appliances used for commercial purposes require a type 1 or type 2 hood
as designated by the Mechanical Code. A hood may not be required only where a
listed appliance has been approved for commercial use without a hood.
Inspector Comments:
02/24/2017COMPLETEDQuinton OwensBuilding Inspector Consultation
Sprinklers are required in assembly occupancies intended for food and drink
consumption where the occupant load is over 100 or is not on the level of exit
discharge (ground level). No partial sprinkler systems are currently allowed per
city ordinance.