HomeMy WebLinkAboutALL DOCS & CO - 11-00082 - 596 Chad Dr - AdditionCertificate of Occupancy
City of Rexburg
Department of Community Development
35 N. 1st E. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Building Permit Number
Site Address
11-00082
596 Chad Dr.
Description of Building or
Portion of Building covered by Certificate
596 Chad Dr. - Addition
Steve Eaton
596 Chad, ID 83440
Name and Address of Owner
Contractor
Applicable Edition of Code
Construction Type
IRC 2009
VB
Use and Occupancy (sq. ft.)
Sq Ft 2803
Design Occupant Load N/A
Sprinkler System Required?N/A
Special Conditions (none)
This Certificate, issued pursuant to the requirements of Section 111 of the International Building Code,
certifies that, at the time of issuance, this building or that portion of the building that was inspected on the
date listed was found to be in compliance with the requirements of the code for the group and division of
occupancy and the use for which the proposed occupancy was classified.
Date C.O. Issued
C.O. Issued by Building Inspector
There shall be no further change in the existing occupancy classification of the building nor shall any structural
changes, modifications or additions be made to the building or any portion thereof until the building Official has
reviewed and approved said future changes.
Mechanical Inspector
Plumbing Inspector
Electrical Inspector
Planning & Zoning
Fire Department:
Fire Alarm:
Fire Sprinkler:
Public Works:
April 04, 2017
Owner Built
Not Required
Not Required
Not Required
Not Required
Not Required
Permit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 05/01/2017 2:38 pm
Permit Details Permit Number: 11-00082
596 Chad Dr. - Addition
596 Chad Dr.
Single Family Residential Addition
Permit Issued Date: 02/13/2014
Permit Inspection Statistics
17Total Inspections Completed:
13Total Inspections Passed:
Inspection Pass Rate
76.47%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Building Inspection Type
04/20/2011PassQuinton OwensFoundation Inspection
06/14/2011FailTed DyeFraming/Structure Inspection
see an engineer on NE cornerInspector Comments:
11/11/2013PassTed DyeFooting Inspection
01/16/2014FailTed DyeInsulation Inspection
provide new resvInspector Comments:
04/04/2017PassTed DyeResidential Building Final
Electrical Inspection Type
09/13/2013PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
Approved for cover in the front living room by the entry only. I talked with Steve
the owner on codes for the rest of his home.
Inspector Comments:
12/31/2013PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
Approved for cover in the floor upstairs-in webbing of floor trusses only on
second level not including the garage ceiling area.
Inspector Comments:
01/16/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
Approved for cover-above kitchen recessed cans(8)(IC rated).Inspector Comments:
01/27/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
Approved for cover on the north and west walls great room downstairs.Inspector Comments:
01/30/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
Approved for cover in kitchen-east wall and upstairs west bedrooms for only one
side of sheetrock.
Inspector Comments:
02/14/2014PassBret StoddardSFR-A, SFR-R, SFR-B, MFR, MFR-A, and MFR-R Electrical Rough-in
03/10/2017FailBret StoddardResidential Electrical Final Inspection
03/17/2017FailBret StoddardResidential Electrical Final Inspection
03/28/2017PassBret StoddardResidential Electrical Final Inspection
Page 1 of 2
(Continued)
Permit Details Permit Number: 11-00082
596 Chad Dr. - Addition
596 Chad Dr.
Single Family Residential Addition
Permit Status of (Issue) as of Report Date: 05/01/2017 2:38 pm
Permit
Inspection
Summary
Mechanical Inspection Type
10/31/2012PassTed DyeHVAC Rough-in
***APPROVED BY JON BERRY***
Supply ducting rough looks good. Returns INW
Inspector Comments:
12/24/2013PassDon AllenGas Pressure Test
presser held at 20lbInspector Comments:
03/07/2017PassDon AllenHVAC Final Inspection
Plumbing Inspection Type
03/02/2017PassDon AllenPlumbing Final Inspection
Good for the C/OInspector Comments:
Page 2 of 2