HomeMy WebLinkAboutAPPLICATION & INSPECTION TICKET & RECEIPT - 17-00095 - 112 N 1st E - Service UpgradeInspection Ticket Residential Electrical Service Inspection on 03/09/2017: PASS Permit Number: 17-00095Permit Details Electrical Only Residential Permit Issued Date: 03/07/2017 Final Inspections Required 112 N 1st E 112 N 1st E - Service Upgrade Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Service Inspection on 03/09/2017: PASS D ESCRIPTIO N CO MMEN TS STATUS Overhead service conductors have proper clearances. 230.24(A)&(B) Overhead conductors at about 14'.COMPLETED Service disconnects and overcurrent devices are located outside or inside nearest the point of entrance of the service conductors. 230.70(A) (1), 230.91 COMPLETED Service disconnects are grouped together, with no more than six in any one location. 230.71, 230.72, 408.36(B) Exc. COMPLETED The point of attachment is adequate and will provide required support and clearances above roofs and grade. 230.24, 230.26, 230.54(C) COMPLETED Panelboards are grounded by an appropriate and properly sized equipment grounding conductor (or conductors). 408.40, 215.6, 250.118, 250.122 COMPLETED Unused openings have been effectively closed (K.O. seals, etc.) 110.12(A), 408.7 COMPLETED Securely mounted gear-panels, meter base, etc. 110.13 COMPLETED Temperature ratings of equipment-lugs, breakers, splices, etc. 110.14(A), (B), (C) COMPLETED Proper clearances about electrical equipment indoors and outdoors. 110.26 (A), (E),(E)(2) and (F) COMPLETED Grounding electrode system installed-ufer, ground rods, metal water piping, etc. 250.52(A) (4-7) Two ground rods installed.COMPLETED Grounding electrode system conductors sized and protected appropriately. 250.66, 250.64(F), 250.64(A)(B) COMPLETED Grounding electrode conductor is either un-spliced or spliced using approved methods. 250.64(C)(F) COMPLETED Page 1 of 2 (Continued) Permit Number: 17-00095 D ESCRIPTIO N CO MMEN TS STATUS Grounding electrode connection(s) are accessible if not irreversible. 250.68(A) COMPLETED Any associated wiring with service meets article 300 wiring methods. COMPLETED Identify wet and damp locations for panels-NEMA 3R, etc. 408.16, 408.37, 312.12 COMPLETED Proper wiring bending space in panel & associated enclosures, gutters, etc. 408.3(G), 312.6, 408.55(A)(B)&(C) COMPLETED Panel or switchgear service rated. 408.3(C)COMPLETED Approved to be energized for permanent power (will send permit to utility). To be re-energized for permanent power.COMPLETED Page 2 of 2 Transaction detail for payment to City of Rexburg. Date: 03/07/2017 - 11:58:09 AM Billing Information Leishman Electric Leishman Electric , 83440 leishmanelectric@yahoo.com City of Rexburg 35 N 1st East | PO Box 280 Rexburg, ID 83440 208-359-3020 ub@rexburg.org XBP Confirmation Number: 27432590 Transaction Number: 65112314PT Visa — XXXX-XXXX-XXXX-6337 Status: Successful Account # Item Quantity Item Amount Electrical Permit 1 $65.00 Notes: Permit # 17-00095 TOTAL:$65.00 Transaction taken by: coltonm Xpress Bill Pay - Payment Processing https://secure.xpressbillpay.com/common/payment_process.php 1 of 1 3/7/2017 11:58 AM