HomeMy WebLinkAboutALL DOCS - 17-00049 - 480 S 4th E - Replace Main Ele PanelInspection
Ticket
Residential Electrical Service Inspection on 02/06/2017: PASS
Permit Number: 17-00049Permit Details
Electrical Only Residential
Permit Issued Date: 02/06/2017
Final Inspections Required
480 S 4th E
480 S 4th E - Replace Main Ele Panel
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Service Inspection on 02/06/2017: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Service disconnects and overcurrent devices
are located outside or inside nearest the point of
entrance of the service conductors. 230.70(A)
(1), 230.91
COMPLETED
Panelboards are grounded by an appropriate
and properly sized equipment grounding
conductor (or
conductors). 408.40, 215.6, 250.118, 250.122
COMPLETED
Unused openings have been effectively closed
(K.O. seals, etc.) 110.12(A), 408.7
COMPLETED
Securely mounted gear-panels, meter base, etc.
110.13
COMPLETED
Temperature ratings of equipment-lugs,
breakers, splices, etc. 110.14(A), (B), (C)
COMPLETED
Grounding electrode system installed-ufer,
ground rods, metal water piping, etc. 250.52(A)
(4-7)
COMPLETED
Grounding electrode system conductors sized
and protected appropriately. 250.66, 250.64(F),
250.64(A)(B)
COMPLETED
Grounding electrode conductor is either
un-spliced or spliced using approved methods.
250.64(C)(F)
COMPLETED
Grounding electrode connection(s) are accessible
if not irreversible. 250.68(A)
COMPLETED
Temporary 125V & 250V 15A & 20A receptacles
must have GFCI protection. 590.4(D)
COMPLETED
Any associated wiring with service meets article
300 wiring methods.
COMPLETED
Identify wet and damp locations for
panels-NEMA 3R, etc. 408.16, 408.37, 312.12
COMPLETED
Proper wiring bending space in panel &
associated enclosures, gutters, etc. 408.3(G),
312.6, 408.55(A)(B)&(C)
COMPLETED
Panel or switchgear service rated. 408.3(C)COMPLETED
Page 1 of 2
(Continued)
Permit Number: 17-00049
D ESCRIPTIO N CO MMEN TS STATUS
Main bonding jumper sized to 250.28(D), and all
panels bonded together using an equipment
bonding conductor sized in accordance with
250.122 or 250.66 as appropriate.
COMPLETED
Service conductors are adequate size and rating.
230.23, 230.31, 230.42
COMPLETED
Approved to be energized for permanent power
(will send permit to utility).
To be re-energized for permanent power. The
meter base and mast are existing and the main
panel is the only thing that was changed out.
Grounding electrode system is existing entirely.
COMPLETED
Page 2 of 2
Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 03/01/2017 2:32 pm
Permit Details Permit Number: 17-00049
480 S 4th E - Replace Main Ele Panel
480 S 4th E
Electrical Only Residential
Permit Issued Date: 02/06/2017
Permit Inspection Statistics
1Total Inspections Completed:
1Total Inspections Passed:
Inspection Pass Rate
100.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Electrical Inspection Type
02/06/2017PassBret StoddardResidential Electrical Service Inspection
Transaction detail for payment to City of Rexburg. Date: 02/06/2017 - 10:17:17 AM
Billing Information
Leishman Electric Leishman
Electric
, 83440
leishmanelectric@yahoo.com
City of Rexburg
35 N 1st East | PO Box 280
Rexburg, ID 83440
208-359-3020
ub@rexburg.org
XBP Confirmation Number: 26362370
Transaction Number: 63633483PT
Visa — XXXX-XXXX-XXXX-6337
Status: Successful
Account # Item Quantity Item Amount
Electrical Permit 1 $65.00
Notes: Permit # 17-00049
TOTAL:$65.00
Transaction taken by: coltonm
Xpress Bill Pay - Payment Processing https://secure.xpressbillpay.com/common/payment_process.php
1 of 1 2/6/2017 10:17 AM