HomeMy WebLinkAboutALL DOCS - 17-00056 - 412 Violet - New Pedestal ServiceInspection Ticket Residential Electrical Service Inspection on 02/14/2017: PASS Permit Number: 17-00056Permit Details Electrical Only Residential Permit Issued Date: 02/13/2017 Final Inspections Required 412 Violet 412 Violet - New Pedestal Service Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Service Inspection on 02/14/2017: PASS D ESCRIPTIO N CO MMEN TS STATUS Underground fed services have proper strapping and expansion fittings. 352.30(A)(B), 352.44 COMPLETED Service disconnects and overcurrent devices are located outside or inside nearest the point of entrance of the service conductors. 230.70(A) (1), 230.91 COMPLETED The point of attachment is adequate and will provide required support and clearances above roofs and grade. 230.24, 230.26, 230.54(C) COMPLETED Panelboards are grounded by an appropriate and properly sized equipment grounding conductor (or conductors). 408.40, 215.6, 250.118, 250.122 COMPLETED Unused openings have been effectively closed (K.O. seals, etc.) 110.12(A), 408.7 COMPLETED Securely mounted gear-panels, meter base, etc. 110.13 COMPLETED Temperature ratings of equipment-lugs, breakers, splices, etc. 110.14(A), (B), (C) COMPLETED Proper clearances about electrical equipment indoors and outdoors. 110.26 (A), (E),(E)(2) and (F) COMPLETED Grounding electrode system installed-ufer, ground rods, metal water piping, etc. 250.52(A) (4-7) Two ground rods installed.COMPLETED Grounding electrode system conductors sized and protected appropriately. 250.66, 250.64(F), 250.64(A)(B) COMPLETED Grounding electrode conductor is either un-spliced or spliced using approved methods. 250.64(C)(F) COMPLETED Grounding electrode connection(s) are accessible if not irreversible. 250.68(A) COMPLETED Page 1 of 2 (Continued) Permit Number: 17-00056 D ESCRIPTIO N CO MMEN TS STATUS Any associated wiring with service meets article 300 wiring methods. 50A receptacle installed for mobile home cord to plug into. COMPLETED Identify wet and damp locations for panels-NEMA 3R, etc. 408.16, 408.37, 312.12 COMPLETED Panel or switchgear service rated. 408.3(C)COMPLETED Main bonding jumper sized to 250.28(D), and all panels bonded together using an equipment bonding conductor sized in accordance with 250.122 or 250.66 as appropriate. COMPLETED Service conductors are adequate size and rating. 230.23, 230.31, 230.42 COMPLETED Approved to be energized for permanent power (will send permit to utility). To remain energized for permanent power. Service was energized over the weekend due to a failure in the meter base. COMPLETED Page 2 of 2 Permit Inspection Summary Permit Status of (Open) as of Report Date: 03/01/2017 2:18 pm Permit Details Permit Number: 17-00056 412 Violet - New Pedestal Service 412 Violet Electrical Only Residential Permit Issued Date: 02/13/2017 Permit Inspection Statistics 1Total Inspections Completed: 1Total Inspections Passed: Inspection Pass Rate 100.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Electrical Inspection Type 02/14/2017PassBret StoddardResidential Electrical Service Inspection