HomeMy WebLinkAboutALL DOCS - 16-00501 - 75 S 5th W #49 - Electrical OnlyInspection
Ticket
Residential Electrical Service Inspection on 08/11/2016: PASS
Permit Number: 16-00501Permit Details
Electrical Only Residential
Permit Issued Date: 07/18/2016
Final Inspections Required
75 S 5th W #49
75 S 5th W #49 - Electrical Only
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Service Inspection on 08/11/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
The point of attachment is adequate and will
provide required support and clearances above
roofs
and grade. 230.24, 230.26, 230.54(C)
COMPLETED
Panelboards are grounded by an appropriate
and properly sized equipment grounding
conductor (or
conductors). 408.40, 215.6, 250.118, 250.122
COMPLETED
Unused openings have been effectively closed
(K.O. seals, etc.) 110.12(A), 408.7
COMPLETED
Securely mounted gear-panels, meter base, etc.
110.13
COMPLETED
Temperature ratings of equipment-lugs,
breakers, splices, etc. 110.14(A), (B), (C)
COMPLETED
Proper clearances about electrical equipment
indoors and outdoors. 110.26 (A), (E),(E)(2) and
(F)
COMPLETED
Grounding electrode system installed-ufer,
ground rods, metal water piping, etc. 250.52(A)
(4-7)
COMPLETED
Grounding electrode system conductors sized
and protected appropriately. 250.66, 250.64(F),
250.64(A)(B)
COMPLETED
Grounding electrode conductor is either
un-spliced or spliced using approved methods.
250.64(C)(F)
COMPLETED
Grounding electrode connection(s) are accessible
if not irreversible. 250.68(A)
COMPLETED
Any associated wiring with service meets article
300 wiring methods.
COMPLETED
Identify wet and damp locations for
panels-NEMA 3R, etc. 408.16, 408.37, 312.12
COMPLETED
Panel or switchgear service rated. 408.3(C)COMPLETED
Page 1 of 2
(Continued)
Permit Number: 16-00501
D ESCRIPTIO N CO MMEN TS STATUS
Main bonding jumper sized to 250.28(D), and all
panels bonded together using an equipment
bonding conductor sized in accordance with
250.122 or 250.66 as appropriate.
COMPLETED
Service conductors are adequate size and rating.
230.23, 230.31, 230.42
COMPLETED
Approved to be energized for permanent power
(will send permit to utility).
To be energized for permanent power-new
pedestal and mobile home space. No mobile
home is on the lot.
COMPLETED
Page 2 of 2
Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/30/2017 5:08 pm
Permit Details Permit Number: 16-00501
75 S 5th W #49 - Electrical Only
75 S 5th W #49
Electrical Only Residential
Permit Issued Date: 07/18/2016
Permit Inspection Statistics
1Total Inspections Completed:
1Total Inspections Passed:
Inspection Pass Rate
100.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Electrical Inspection Type
08/11/2016PassBret StoddardResidential Electrical Service Inspection
Transaction detail for payment to City of Rexburg.Date: 07/18/2016 - 11:07:18 AM
Billing Information
LEISHMAN ELECTRIC
LEISHMAN ELECTRIC
, 83440
bcleishman@msn.com
Transaction Details
City of Rexburg
35 N 1st East | PO Box 280
Rexburg, ID 83440
XBP Confirmation Number: 19591022
Transaction Number: 54402494PT
Visa — XXXX-XXXX-XXXX-6337
Status: Successful
Account # Item Quantity Item Amount
Electrical Permit 1 $130.00
Notes: Permit # 16-00501
TOTAL:$130.00
Transaction taken by:cecilj
Email:bcleishman@msn.com
Page 1 of 1Xpress Bill Pay - Transaction Details
7/18/2016https://www.xpressbillpay.com/common/trans_details.php?trans_id=NDU4NTAzMTI%3...