HomeMy WebLinkAboutALL DOCS - 16-00501 - 75 S 5th W #49 - Electrical OnlyInspection Ticket Residential Electrical Service Inspection on 08/11/2016: PASS Permit Number: 16-00501Permit Details Electrical Only Residential Permit Issued Date: 07/18/2016 Final Inspections Required 75 S 5th W #49 75 S 5th W #49 - Electrical Only Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Service Inspection on 08/11/2016: PASS D ESCRIPTIO N CO MMEN TS STATUS The point of attachment is adequate and will provide required support and clearances above roofs and grade. 230.24, 230.26, 230.54(C) COMPLETED Panelboards are grounded by an appropriate and properly sized equipment grounding conductor (or conductors). 408.40, 215.6, 250.118, 250.122 COMPLETED Unused openings have been effectively closed (K.O. seals, etc.) 110.12(A), 408.7 COMPLETED Securely mounted gear-panels, meter base, etc. 110.13 COMPLETED Temperature ratings of equipment-lugs, breakers, splices, etc. 110.14(A), (B), (C) COMPLETED Proper clearances about electrical equipment indoors and outdoors. 110.26 (A), (E),(E)(2) and (F) COMPLETED Grounding electrode system installed-ufer, ground rods, metal water piping, etc. 250.52(A) (4-7) COMPLETED Grounding electrode system conductors sized and protected appropriately. 250.66, 250.64(F), 250.64(A)(B) COMPLETED Grounding electrode conductor is either un-spliced or spliced using approved methods. 250.64(C)(F) COMPLETED Grounding electrode connection(s) are accessible if not irreversible. 250.68(A) COMPLETED Any associated wiring with service meets article 300 wiring methods. COMPLETED Identify wet and damp locations for panels-NEMA 3R, etc. 408.16, 408.37, 312.12 COMPLETED Panel or switchgear service rated. 408.3(C)COMPLETED Page 1 of 2 (Continued) Permit Number: 16-00501 D ESCRIPTIO N CO MMEN TS STATUS Main bonding jumper sized to 250.28(D), and all panels bonded together using an equipment bonding conductor sized in accordance with 250.122 or 250.66 as appropriate. COMPLETED Service conductors are adequate size and rating. 230.23, 230.31, 230.42 COMPLETED Approved to be energized for permanent power (will send permit to utility). To be energized for permanent power-new pedestal and mobile home space. No mobile home is on the lot. COMPLETED Page 2 of 2 Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/30/2017 5:08 pm Permit Details Permit Number: 16-00501 75 S 5th W #49 - Electrical Only 75 S 5th W #49 Electrical Only Residential Permit Issued Date: 07/18/2016 Permit Inspection Statistics 1Total Inspections Completed: 1Total Inspections Passed: Inspection Pass Rate 100.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Electrical Inspection Type 08/11/2016PassBret StoddardResidential Electrical Service Inspection Transaction detail for payment to City of Rexburg.Date: 07/18/2016 - 11:07:18 AM Billing Information LEISHMAN ELECTRIC LEISHMAN ELECTRIC , 83440 bcleishman@msn.com Transaction Details City of Rexburg 35 N 1st East | PO Box 280 Rexburg, ID 83440 XBP Confirmation Number: 19591022 Transaction Number: 54402494PT Visa — XXXX-XXXX-XXXX-6337 Status: Successful Account # Item Quantity Item Amount Electrical Permit 1 $130.00 Notes: Permit # 16-00501 TOTAL:$130.00 Transaction taken by:cecilj Email:bcleishman@msn.com Page 1 of 1Xpress Bill Pay - Transaction Details 7/18/2016https://www.xpressbillpay.com/common/trans_details.php?trans_id=NDU4NTAzMTI%3...