HomeMy WebLinkAboutALL DOCS - 16-00546 - 1333 Fairview Ave - Ele OnlyInspection Ticket Residential Electrical Final Inspection on 11/29/2016: PASS Permit Number: 16-00546Permit Details Electrical Only Residential Permit Issued Date: 09/23/2016 Final Inspections Required 1333 Fairview Ave 1333 Fairview Ave - Ele Only Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Final Inspection on 11/29/2016: PASS D ESCRIPTIO N CO MMEN TS STATUS Proper use of connectors and fittings and for protection of cables. 300.15 COMPLETED Unused openings in boxes and other enclosures are closed. 110.12, 314.17(A), 312.5(A) COMPLETED Bushings or equivalent protection for cables entering boxes and other enclosures. 300.4(F), 314.17, 314.42 COMPLETED Proper identification of all overcurrent devices and disconnects. 110.22, 230.70(B), 408.4 COMPLETED Open spaces in panelboard fronts. 110.12 COMPLETED Approved for a Final and C.O.For a final-generator install only. Load shed device is installed on the hot tub circuit. COMPLETED Inspection Ticket Residential Electrical Service Inspection on 08/09/2016: PASS Permit Number: 16-00546Permit Details Electrical Only Residential Permit Issued Date: 09/23/2016 Final Inspections Required 1333 Fairview Ave 1333 Fairview Ave - Ele Only Inspection Details bret.stoddard@rexburg.org Inspected By: Bret Stoddard Residential Electrical Service Inspection on 08/09/2016: PASS D ESCRIPTIO N CO MMEN TS STATUS Panelboards are grounded by an appropriate and properly sized equipment grounding conductor (or conductors). 408.40, 215.6, 250.118, 250.122 COMPLETED Unused openings have been effectively closed (K.O. seals, etc.) 110.12(A), 408.7 COMPLETED Securely mounted gear-panels, meter base, etc. 110.13 COMPLETED Temperature ratings of equipment-lugs, breakers, splices, etc. 110.14(A), (B), (C) COMPLETED Proper clearances about electrical equipment indoors and outdoors. 110.26 (A), (E),(E)(2) and (F) COMPLETED Any associated wiring with service meets article 300 wiring methods. COMPLETED Proper wiring bending space in panel & associated enclosures, gutters, etc. 408.3(G), 312.6, 408.55(A)(B)&(C) COMPLETED Panel or switchgear service rated. 408.3(C)Transfer switch is service rated.COMPLETED Main bonding jumper sized to 250.28(D), and all panels bonded together using an equipment bonding conductor sized in accordance with 250.122 or 250.66 as appropriate. COMPLETED Service conductors are adequate size and rating. 230.23, 230.31, 230.42 COMPLETED Approved to be energized for permanent power (will send permit to utility). To be re-energized for permanent power-added a transfer switch to the electrical service. All wiring in the main panel is existing. Must call for a re-inspect when the generator is actually installed and load shed devices are installed. COMPLETED Permit Inspection Summary Permit Status of (Open) as of Report Date: 01/30/2017 4:10 pm Permit Details Permit Number: 16-00546 1333 Fairview Ave - Ele Only 1333 Fairview Ave Electrical Only Residential Permit Issued Date: 09/23/2016 Permit Inspection Statistics 2Total Inspections Completed: 2Total Inspections Passed: Inspection Pass Rate 100.00% Permit Inspection History *Refer to Individual Inspection Report for more Details Electrical Inspection Type 08/09/2016PassBret StoddardResidential Electrical Service Inspection 11/29/2016PassBret StoddardResidential Electrical Final Inspection