Residential Electrical Final Inspection on 11/29/2016: PASS
Permit Number: 16-00546Permit Details
Electrical Only Residential
Permit Issued Date: 09/23/2016
Final Inspections Required
1333 Fairview Ave
1333 Fairview Ave - Ele Only
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Final Inspection on 11/29/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Proper use of connectors and fittings and for
protection of cables. 300.15
COMPLETED
Unused openings in boxes and other enclosures
are closed. 110.12, 314.17(A), 312.5(A)
COMPLETED
Bushings or equivalent protection for cables
entering boxes and other enclosures. 300.4(F),
314.17, 314.42
COMPLETED
Proper identification of all overcurrent devices
and disconnects. 110.22, 230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Approved for a Final and C.O.For a final-generator install only. Load shed
device is installed on the hot tub circuit.
COMPLETED
Inspection
Ticket
Residential Electrical Service Inspection on 08/09/2016: PASS
Permit Number: 16-00546Permit Details
Electrical Only Residential
Permit Issued Date: 09/23/2016
Final Inspections Required
1333 Fairview Ave
1333 Fairview Ave - Ele Only
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Service Inspection on 08/09/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Panelboards are grounded by an appropriate
and properly sized equipment grounding
conductor (or
conductors). 408.40, 215.6, 250.118, 250.122
COMPLETED
Unused openings have been effectively closed
(K.O. seals, etc.) 110.12(A), 408.7
COMPLETED
Securely mounted gear-panels, meter base, etc.
110.13
COMPLETED
Temperature ratings of equipment-lugs,
breakers, splices, etc. 110.14(A), (B), (C)
COMPLETED
Proper clearances about electrical equipment
indoors and outdoors. 110.26 (A), (E),(E)(2) and
(F)
COMPLETED
Any associated wiring with service meets article
300 wiring methods.
COMPLETED
Proper wiring bending space in panel &
associated enclosures, gutters, etc. 408.3(G),
312.6, 408.55(A)(B)&(C)
COMPLETED
Panel or switchgear service rated. 408.3(C)Transfer switch is service rated.COMPLETED
Main bonding jumper sized to 250.28(D), and all
panels bonded together using an equipment
bonding conductor sized in accordance with
250.122 or 250.66 as appropriate.
COMPLETED
Service conductors are adequate size and rating.
230.23, 230.31, 230.42
COMPLETED
Approved to be energized for permanent power
(will send permit to utility).
To be re-energized for permanent power-added
a transfer switch to the electrical service. All
wiring in the main panel is existing. Must call for
a re-inspect when the generator is actually
installed and load shed devices are installed.
COMPLETED
Permit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/30/2017 4:10 pm
Permit Details Permit Number: 16-00546
1333 Fairview Ave - Ele Only
1333 Fairview Ave
Electrical Only Residential
Permit Issued Date: 09/23/2016
Permit Inspection Statistics
2Total Inspections Completed:
2Total Inspections Passed:
Inspection Pass Rate
100.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Electrical Inspection Type
08/09/2016PassBret StoddardResidential Electrical Service Inspection
11/29/2016PassBret StoddardResidential Electrical Final Inspection