HomeMy WebLinkAboutALL DOCS - 16-00617 - 126 W 1st N - Relocate Service Inspections must be called in before 8 AM on the day the inspection is requested. Inspection requests called in after 8 AM will be scheduled for the next business day. Inspection Hotline – (208) 372.2344 www.rexburg.org Permit Technician – (208) 372.2341 Revised March, 2016
Building Safety Department City of Rexburg 35 North 1st East Rexburg, Idaho 83440
BUILDING APPLICATION Electrical For Office Use Permit Number: ____________________ Permit Type: ⧠ New ⧠ Remodel ⧠ Addition ⧠ Basement Finish Fees Paid: ⧠ Yes ⧠ No 1. Property Owner Name: ___________________________________________________________ Address: ___________________________________________________ City: __________________________ State: ____________ Zip Code: _________________ Phone & Type: _______________________ ⧠ Office ⧠ Mobile Email: _____________________________________________________________________ Under Idaho Building Code, a homeowner is allowed to do work on their own home. Are you a homeowner doing work on your own home? ⧠ Yes (Skip to #3 and complete the Homeowner’s Exemption page) ⧠ No: I am a contractor working for the homeowner ⧠ No: This property is a Multi-family Residence or Commercial Property. NOTE: Any contractors/sub-contractors involved will need to submit their own signed applications. 2. Electrical Contractor Name: _____________________________________________________________ Registration #: _________________________ Exp.: _______________________ Address: ___________________________________________________ City: __________________________ State: ____________ Zip Code: _________________ Phone & Type: ___________________________________ ⧠ Office ⧠ Mobile Email: __________________________________________________________ Contact/Rep. Name: ______________________________________ Phone: _________________ Email: ______________________________________________ Electrical Contractor Authorized Signature: ____________________________________________________________________ Date:_________________ 3. Project Description Address: _______________________________________ -OR- Lot #: ____ Block #: ____ Subdivision: _________________________________ Check one: ⧠ Single-family Residence ⧠ Multi-family Residence ⧠ Commercial Check one: ⧠ New Construction* ⧠ Remodel ⧠ Addition ⧠ Basement Finish Description of work: _____________________________________________________________________________________________________________________ New Commercial Work: Contracted amount: $________________________________ Calculated Fee (See Below): $___________________ ⧠ Up to $10,000 = (total cost of system x .02) + $60 ⧠ $10,001-$100,000 = ((total cost of system -10,000) x .01) + $260 ⧠ Over $100,001 = ((total cost of system -100,000) x .005) + $1,160 New Single-Family Residential Work: _________ Sq. Ft. ⧠ Up to 1,500 Sq. Ft. = $130 ⧠ 1,501-2,500 Sq. Ft. = $195 ⧠ 2,501-3,500 Sq. Ft. = $260 ⧠ 3,501-4,500 Sq. Ft. = $325 ⧠ Over 4,500 Sq. Ft. = $325+(65 x # of additional 1,000 Sq. Ft. (or portion thereof)) $_________________ New Multi-Family Residential: ⧠ Duplex = $260 ⧠ Three or more units = $((130 x # of buildings)+(65 x # of units))$_________ New work on any other residence and Detached Shops: = $(65 + (10 x # of branch circuits)) $__________________ Miscellaneous: ⧠ Small Works (work costing less than $200 with no change in service connections)=$10(needs no inspection.) ⧠ Central Heating/Cooling Systems = $65 ⧠ Spas, Hot Tubs, and Swimming Pools = $65 ⧠ Requested Inspection = $65 ⧠ Pumps - Water, Irrigation, Sewage (per motor) = ⧠ $65 up to 25HP ⧠ $95 26- 200HP ⧠ $130 over 200HP ⧠ Irrigation Machine = $65 for center pivot + $10 per tower of drive motor $_____________ ⧠ Technical Service = $65/hour ⧠ Temporary Amusement = $65 + $10 per ride, concession, or generator $__________ ⧠ Plan Check =10% of Contracted Amount ⧠ Temporary Construction Services ONLY = $65 (200 amp or less. One location, for less than 1 year.) APPLICANT’S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2012 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Applicant’s Name (print): ___________________________________ Signature: _____________________________________________ Date: _______________
Inspection
Ticket
Electrical Final Inspection COM-A,R,T on 10/25/2016: PASS
Permit Number: 16-00617Permit Details
Electrical Only Residential
Permit Issued Date: 09/13/2016
Final Inspections Required
126 West 1st North
126 W 1st N - Relocate Service
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Electrical Final Inspection COM-A,R,T on 10/25/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Verify that unused openings have been
effectively closed.110.12(A), 408.7
COMPLETED
Verify adequate working clearances, dedicated
spaces, and headroom around equipment.
110.26(A), (E), and (F)
COMPLETED
Check adequacy of entrance to and exit from
working
space in general and verify that spaces
containing large
equipment have at least two entrances/exits.
110.26(C), 110.26(C)(2)
COMPLETED
Verify that working spaces have adequate
illumination.110.26(D)
COMPLETED
Check for identification of disconnecting means
and circuit directories for panelboards,
switchboards, and similar equipment.110.22,
408.4
COMPLETED
Check wiring methods for spacing from edges of
framing and for protection from nails and
screws. 300.4(A), (B), (D), and (E)
COMPLETED
Check for insulating bushings or grommets
where NM cable is installed through metal studs
or conductors 4 AWG or larger enter enclosures.
300.4(B)(1) and (F)
COMPLETED
Check for closure of unused openings.314.17(A)COMPLETED
Check for excessive gaps between edges of
boxes and
plaster, plasterboard, or drywall surfaces.314.21
COMPLETED
Verify that all boxes are accessible. 314.29 COMPLETED
Verify that switches or receptacles in boxes have
their plaster ears seated against the wall surface
or the box.404.10(B), 406.4(A) and (B)
COMPLETED
Approved for a final and C.O.For a final to close the permit. This inspection is
only for the changing out of the main electrical
COMPLETED
Page 1 of 2
(Continued)
Permit Number: 16-00617
D ESCRIPTIO N CO MMEN TS STATUS
panel in the living room that was part of the
electrical service change out a few weeks
earlier.
Page 2 of 2
Inspection
Ticket
Residential Electrical Service Inspection on 09/21/2016: PASS
Permit Number: 16-00617Permit Details
Electrical Only Residential
Permit Issued Date: 09/13/2016
Final Inspections Required
126 West 1st North
126 W 1st N - Relocate Service
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Service Inspection on 09/21/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Overhead service conductors have proper
clearances. 230.24(A)&(B)
Must install a guy wire to the mast and will
inspect on the final inspection when the panel is
changed out inside the dwelling.
COMPLETED
Service disconnects and overcurrent devices
are located outside or inside nearest the point of
entrance of the service conductors. 230.70(A)
(1), 230.91
COMPLETED
The point of attachment is adequate and will
provide required support and clearances above
roofs
and grade. 230.24, 230.26, 230.54(C)
COMPLETED
Panelboards are grounded by an appropriate
and properly sized equipment grounding
conductor (or
conductors). 408.40, 215.6, 250.118, 250.122
COMPLETED
Unused openings have been effectively closed
(K.O. seals, etc.) 110.12(A), 408.7
COMPLETED
Securely mounted gear-panels, meter base, etc.
110.13
COMPLETED
Proper clearances about electrical equipment
indoors and outdoors. 110.26 (A), (E),(E)(2) and
(F)
COMPLETED
Grounding electrode system installed-ufer,
ground rods, metal water piping, etc. 250.52(A)
(4-7)
Installed two ground rods for new service.COMPLETED
Grounding electrode system conductors sized
and protected appropriately. 250.66, 250.64(F),
250.64(A)(B)
COMPLETED
Grounding electrode conductor is either
un-spliced or spliced using approved methods.
250.64(C)(F)
COMPLETED
Grounding electrode connection(s) are accessible
if not irreversible. 250.68(A)
COMPLETED
Any associated wiring with service meets article
300 wiring methods.
COMPLETED
Page 1 of 2
(Continued)
Permit Number: 16-00617
D ESCRIPTIO N CO MMEN TS STATUS
Identify wet and damp locations for
panels-NEMA 3R, etc. 408.16, 408.37, 312.12
COMPLETED
Proper wiring bending space in panel &
associated enclosures, gutters, etc. 408.3(G),
312.6, 408.55(A)(B)&(C)
COMPLETED
Panel or switchgear service rated. 408.3(C)COMPLETED
Main bonding jumper sized to 250.28(D), and all
panels bonded together using an equipment
bonding conductor sized in accordance with
250.122 or 250.66 as appropriate.
COMPLETED
Service conductors are adequate size and rating.
230.23, 230.31, 230.42
COMPLETED
Approved to be energized for permanent power
(will send permit to utility).
To be re-energized for permanent power. Must
call in for a re-inspect when the panel is
re-installed inside the dwelling-for a final
inspection.
COMPLETED
Page 2 of 2
Permit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 01/30/2017 1:05 pm
Permit Details Permit Number: 16-00617
126 W 1st N - Relocate Service
126 West 1st North
Electrical Only Residential
Permit Issued Date: 09/13/2016
Permit Inspection Statistics
2Total Inspections Completed:
2Total Inspections Passed:
Inspection Pass Rate
100.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Electrical Inspection Type
09/21/2016PassBret StoddardResidential Electrical Service Inspection
10/25/2016PassBret StoddardElectrical Final Inspection COM-A,R,T
Transaction detail for payment to City of Rexburg. Date: 09/13/2016 - 8:39:27 AM
Billing Information
Kimberly J Edwards Kimberly J
Edwards
, 83440
gledwardselectric@gmail.com
City of Rexburg
35 N 1st East | PO Box 280
Rexburg, ID 83440
208-359-3020
ub@rexburg.org
XBP Confirmation Number: 21523558
Transaction Number: 56926589PT
Visa — XXXX-XXXX-XXXX-9606
Status: Successful
Account # Item Quantity Item Amount
16-00617 Electrical Permit 1 $65.00
Notes: Permit # 16-00617
TOTAL:$65.00
Transaction taken by: coltonm
Xpress Bill Pay - Payment Processing https://secure.xpressbillpay.com/common/payment_process.php
1 of 1 9/13/2016 8:39 AM