HomeMy WebLinkAboutALL DOCS - 16-00691 - 789 Engleman - SolarInspection
Ticket
Residential Electrical Final Inspection on 10/21/2016: PASS
Permit Number: 16-00691Permit Details
Electrical Only Residential
Permit Issued Date: 10/11/2016
Final Inspections Required
789 Engleman
789 Engleman - Solar
Inspection Details
bret.stoddard@rexburg.org
Inspected By: Bret Stoddard
Residential Electrical Final Inspection on 10/21/2016: PASS
D ESCRIPTIO N CO MMEN TS STATUS
Check for correction of any deficiencies noted on
previous inspections.
COMPLETED
Positioning of boxes intended to be flush with
combustible and noncombustible finished
surfaces. 314.20
COMPLETED
Gaps around boxes in walls. 314.21 COMPLETED
Polarity of devices and luminaires. 200.10(B),
200.11, 410.23, 406.9
COMPLETED
Proper use of connectors and fittings and for
protection of cables. 300.15
COMPLETED
Unused openings in boxes and other enclosures
are closed. 110.12, 314.17(A), 312.5(A)
COMPLETED
Bushings or equivalent protection for cables
entering boxes and other enclosures. 300.4(F),
314.17, 314.42
COMPLETED
Installation of listed equipment for compliance
with manufacturer’s instructions. 110.3(B)
COMPLETED
Proper receptacle ratings based on branch-circuit
ratings, including receptacles for electric dryers.
210.21, 210.24, 250.140
COMPLETED
Proper identification of all overcurrent devices
and disconnects. 110.22, 230.70(B), 408.4
COMPLETED
Open spaces in panelboard fronts. 110.12 COMPLETED
Backfed overcurrent devices are secured in
place. 408.36(F)
COMPLETED
Approved for a Final and C.O.For a final for the PV (Solar) installation only.
Inspected to the drawings that were on site in
the disconnect. There were only 18 solar panels
installed in the array. #8 grounding electrode
conductor installed from the array racking to
the ufer in the garage.
COMPLETED
Permit
Inspection
Summary
Permit Status of (Issue) as of Report Date: 01/27/2017 9:04 am
Permit Details Permit Number: 16-00691
789 Engleman - Solar
789 Engleman
Electrical Only Residential
Permit Issued Date: 10/11/2016
Permit Inspection Statistics
1Total Inspections Completed:
1Total Inspections Passed:
Inspection Pass Rate
100.00%
Permit Inspection History *Refer to Individual Inspection Report for more Details
Electrical Inspection Type
10/21/2016PassBret StoddardResidential Electrical Final Inspection
Transaction detail for payment to City of Rexburg. Date: 10/11/2016 - 1:59:47 PM
Billing Information
Big Dog Renewable Energy Big
Dog Renewable Energy
, 83202
terissa@bigdogsatellite.com
City of Rexburg
35 N 1st East | PO Box 280
Rexburg, ID 83440
208-359-3020
ub@rexburg.org
XBP Confirmation Number: 22427509
Transaction Number: 58190837PT
Mastercard — XXXX-XXXX-XXXX-1401
Status: Successful
Account # Item Quantity Item Amount
Electrical Permit 1 $273.00
TOTAL:$273.00
Transaction taken by: coltonm
Xpress Bill Pay - Payment Processing https://secure.xpressbillpay.com/common/payment_process.php
1 of 1 10/11/2016 1:59 PM