HomeMy WebLinkAboutALL DOCS - 13-00108 - Rigby 4-PlexPermit
Inspection
Summary
Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am
Permit Details Permit Number: 13-00108
Rigby 4-Plex
507, 509, 511, 513 N PLEASANT COUNTRY DR
Multi-Family Residential Rigby
Permit Issued Date: 04/12/2013
Permit Inspection Statistics
22Total Inspections Completed:
17Total Inspections Passed:
Inspection Pass Rate: 77.27%
Permit Inspection History *Refer to Individual Inspection Report for more Details
04/05/2013PassQuinton OwensFooting Inspection
Footings for 4-plexInspector Comments:
04/08/2013PassQuinton OwensFoundation Inspection
2 corners missing min. clearance - Fix before pour. #4's at 2' oc and 3 #4
horizontal.
Inspector Comments:
04/16/2013PassTed DyeFooting Inspection
footings and rebar look good however property lines are not marked. not able
to verify distance to property line If building is less than 5'-0" the wall will
have to be rated.
Called and left message twice. Third time was able to talk to Mr Shippen and he
said they plan on rating the wall.
Inspector Comments:
04/22/2013PassQuinton OwensFoundation Inspection
Garage foundation approved per codeInspector Comments:
05/15/2013PassBret StoddardElectrical Service Inspection
Fire retardant plywood on exterior walls (less than 10' fire sep). OK to cover.Inspector Comments:
05/21/2013PassQuinton OwensSheeting
some studs not nailed with sheathing. marked with red crayon inside. Reinspect
with framing.
Inspector Comments:
05/31/2013PassBret StoddardElectrical Rough-in
06/04/2013FailQuinton OwensHVAC Rough-in
6/4,QO: All gas lines held 25 psi for 28 min.
Exhaust fans need damper, shaft, or solid metal (no plastic connections
exposed). Flex ductwork in attic with no fire partition yet - need fire partition or
rated ceiling with dampers at all penetrations.
Inspector Comments:
06/13/2013PassDon AllenPlumbing Underground Inspection
there is no undergroundInspector Comments:
07/08/2013PassQuinton OwensHVAC Rough-in
Comb. air penetration to have rated protection for final.
Upstairs dampers to be in at final.
Inspector Comments:
Page 1 of 3
(Continued)
Permit Details Permit Number: 13-00108
Rigby 4-Plex
507, 509, 511, 513 N PLEASANT COUNTRY DR
Multi-Family Residential Rigby
Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am
Permit
Inspection
Summary
07/08/2013FailQuinton OwensFraming/Structure Inspection
Firecaulking (non-rated walls) and fireblocking (rated walls) not done at plate
penetrations.
Inspector Comments:
07/12/2013PassQuinton OwensFraming/Structure Inspection
Firecaulking and fireblocking done.Inspector Comments:
07/12/2013PassQuinton OwensInsulation Inspection
1" clearance required between b-vent and insulation in floor/ceiling assembly.
(verify by final).
Thermal envelope- blown cellulose, windows U=.34, doors & windows sealed,
vent baffles in.
Inspector Comments:
07/16/2013Pass Sheetrock/Drywall Inspection
7-16-13
btm level ok to tape
call when upper level is comlete except for chase, leave open for inspection
7-22-13
all units compete
outside entry needs type x firecode and fire taped
7-24-13
exterior corridor fire taped.
Inspector Comments:
6/19: garage sheathing OK to cover. Fire retrd. treated wood only on North &
West side complete for property line separation.
Inspector Comments:
5/21: Sheathing Nail hold down straps. Ext.not nailed to studs at marked
locations. staples 2-3" at edge. 5-6" in field.
Inspector Comments:
5/29: Garage sheathing- north gable end not fire resistant plywood. Seismic
straps covered - could not inspect. South end- not rated.
Inspector Comments:
07/24/2013PassQuinton OwensFraming/Structure Inspection
7/24, QO: This framing approval is for sheathing only.Inspector Comments:
08/28/2013FailQuinton OwensHVAC Final Inspection
Supply conditioned air to crawl space. Fix detached duct support (South side of
North unit crawl space). Strap Water heater (Plmb). Seal Furnace connection to
duct. Firecaulk pipes penetrating ceiling by W.H. Fan won't turn on for Furnaces
on both South units. Seal around damper on comb. air (top floor north apt).
Inspector Comments:
08/30/2013PassBret StoddardElectrical Final Inspection
Approved for a final and C.O. entire building-garages and units.Inspector Comments:
08/30/2013FailQuinton OwensBuilding Final
Finish Drywall (5/8 type x) under stairs -incl. walls (fireclk penetrarions). Back
landing 3x3 area excess slope. Rear Handrail extensions missing on handrails &
guard should be 42" above stair tread nosing. No occupancy on garages (not
drywalled inside near property line. Fire inspection needs approval. Handrail only
on one side at front stairs.
Inspector Comments:
09/03/2013PassDon AllenPlumbing Rough-in
Page 2 of 3
(Continued)
Permit Details Permit Number: 13-00108
Rigby 4-Plex
507, 509, 511, 513 N PLEASANT COUNTRY DR
Multi-Family Residential Rigby
Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am
Permit
Inspection
Summary
09/24/2013PassDon AllenPlumbing Final Inspection
06/21/2016FailQuinton OwensBuilding Final
Only partial items requested. Call inspection when all corrections can be
inspected at once. Call if there are questions about the corrections needed.
Inspector Comments:
Mechanical Inspection Type
08/30/2013PassQuinton OwensHVAC Final Inspection
HVAC corrections completed.Inspector Comments:
Inspections Required
Sidewalk Inspection
Commercial Building Final