HomeMy WebLinkAboutALL DOCS - 13-00108 - Rigby 4-PlexPermit Inspection Summary Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am Permit Details Permit Number: 13-00108 Rigby 4-Plex 507, 509, 511, 513 N PLEASANT COUNTRY DR Multi-Family Residential Rigby Permit Issued Date: 04/12/2013 Permit Inspection Statistics 22Total Inspections Completed: 17Total Inspections Passed: Inspection Pass Rate: 77.27% Permit Inspection History *Refer to Individual Inspection Report for more Details 04/05/2013PassQuinton OwensFooting Inspection Footings for 4-plexInspector Comments: 04/08/2013PassQuinton OwensFoundation Inspection 2 corners missing min. clearance - Fix before pour. #4's at 2' oc and 3 #4 horizontal. Inspector Comments: 04/16/2013PassTed DyeFooting Inspection footings and rebar look good however property lines are not marked. not able to verify distance to property line If building is less than 5'-0" the wall will have to be rated. Called and left message twice. Third time was able to talk to Mr Shippen and he said they plan on rating the wall. Inspector Comments: 04/22/2013PassQuinton OwensFoundation Inspection Garage foundation approved per codeInspector Comments: 05/15/2013PassBret StoddardElectrical Service Inspection Fire retardant plywood on exterior walls (less than 10' fire sep). OK to cover.Inspector Comments: 05/21/2013PassQuinton OwensSheeting some studs not nailed with sheathing. marked with red crayon inside. Reinspect with framing. Inspector Comments: 05/31/2013PassBret StoddardElectrical Rough-in 06/04/2013FailQuinton OwensHVAC Rough-in 6/4,QO: All gas lines held 25 psi for 28 min. Exhaust fans need damper, shaft, or solid metal (no plastic connections exposed). Flex ductwork in attic with no fire partition yet - need fire partition or rated ceiling with dampers at all penetrations. Inspector Comments: 06/13/2013PassDon AllenPlumbing Underground Inspection there is no undergroundInspector Comments: 07/08/2013PassQuinton OwensHVAC Rough-in Comb. air penetration to have rated protection for final. Upstairs dampers to be in at final. Inspector Comments: Page 1 of 3 (Continued) Permit Details Permit Number: 13-00108 Rigby 4-Plex 507, 509, 511, 513 N PLEASANT COUNTRY DR Multi-Family Residential Rigby Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am Permit Inspection Summary 07/08/2013FailQuinton OwensFraming/Structure Inspection Firecaulking (non-rated walls) and fireblocking (rated walls) not done at plate penetrations. Inspector Comments: 07/12/2013PassQuinton OwensFraming/Structure Inspection Firecaulking and fireblocking done.Inspector Comments: 07/12/2013PassQuinton OwensInsulation Inspection 1" clearance required between b-vent and insulation in floor/ceiling assembly. (verify by final). Thermal envelope- blown cellulose, windows U=.34, doors & windows sealed, vent baffles in. Inspector Comments: 07/16/2013Pass Sheetrock/Drywall Inspection 7-16-13 btm level ok to tape call when upper level is comlete except for chase, leave open for inspection 7-22-13 all units compete outside entry needs type x firecode and fire taped 7-24-13 exterior corridor fire taped. Inspector Comments: 6/19: garage sheathing OK to cover. Fire retrd. treated wood only on North & West side complete for property line separation. Inspector Comments: 5/21: Sheathing Nail hold down straps. Ext.not nailed to studs at marked locations. staples 2-3" at edge. 5-6" in field. Inspector Comments: 5/29: Garage sheathing- north gable end not fire resistant plywood. Seismic straps covered - could not inspect. South end- not rated. Inspector Comments: 07/24/2013PassQuinton OwensFraming/Structure Inspection 7/24, QO: This framing approval is for sheathing only.Inspector Comments: 08/28/2013FailQuinton OwensHVAC Final Inspection Supply conditioned air to crawl space. Fix detached duct support (South side of North unit crawl space). Strap Water heater (Plmb). Seal Furnace connection to duct. Firecaulk pipes penetrating ceiling by W.H. Fan won't turn on for Furnaces on both South units. Seal around damper on comb. air (top floor north apt). Inspector Comments: 08/30/2013PassBret StoddardElectrical Final Inspection Approved for a final and C.O. entire building-garages and units.Inspector Comments: 08/30/2013FailQuinton OwensBuilding Final Finish Drywall (5/8 type x) under stairs -incl. walls (fireclk penetrarions). Back landing 3x3 area excess slope. Rear Handrail extensions missing on handrails & guard should be 42" above stair tread nosing. No occupancy on garages (not drywalled inside near property line. Fire inspection needs approval. Handrail only on one side at front stairs. Inspector Comments: 09/03/2013PassDon AllenPlumbing Rough-in Page 2 of 3 (Continued) Permit Details Permit Number: 13-00108 Rigby 4-Plex 507, 509, 511, 513 N PLEASANT COUNTRY DR Multi-Family Residential Rigby Permit Status of (Open) as of Report Date: 01/19/2017 10:40 am Permit Inspection Summary 09/24/2013PassDon AllenPlumbing Final Inspection 06/21/2016FailQuinton OwensBuilding Final Only partial items requested. Call inspection when all corrections can be inspected at once. Call if there are questions about the corrections needed. Inspector Comments: Mechanical Inspection Type 08/30/2013PassQuinton OwensHVAC Final Inspection HVAC corrections completed.Inspector Comments: Inspections Required Sidewalk Inspection Commercial Building Final Page 3 of 3