Loading...
HomeMy WebLinkAboutAPPLICATIONS, MULT DOCS - 13-00293 & 13-00294 - 526 First American Cir - Edward Jones OfficePermit Inspection Summary Permit Status of (Expired) as of Report Date: 01/17/2017 8:47 am Permit Details Permit Number: 13-00294 Edward Jones Office 526 FIRST AMERICAN CIR Building - Commercial Permit Issued Date: 09/20/2013 Permit Inspection Statistics 21Total Inspections Completed: 15Total Inspections Passed: Inspection Pass Rate 71.43% Permit Inspection History *Refer to Individual Inspection Report for more Details 09/06/2013PassQuinton OwensFooting Inspection 09/11/2013PassQuinton OwensFoundation Inspection #4 vert bar at 24"oc. & 2 #4 horiz in top & bottom and 1 #4 in middle. 2 vent openings on north and south side (each). Flood vents required. Inspector Comments: 10/31/2013PassBret StoddardElectrical Service Inspection Approved to be energized for permanent power-after much discussion the electrical service is over sized for the future space(320A), the electrical contractor insisted upon this size for a possible x-ray machine in the future space. The electrical distributors in town claim that there is no such thing as a 200A on one side and a 320 on the other to provide one main service instead of two. We are now mandating an electrical service plan for all commercial projects as the result of this. Inspector Comments: 11/08/2013FailQuinton OwensSheeting 11/8: finish nailing tie down straps and joint blocking to be nailed. Small sections not nailed by back door of north side and window on north wall. Inspector Comments: 01/06/2014PassQuinton OwensSheeting Reinspected with framing inspection.Inspector Comments: 01/06/2014FailQuinton OwensFraming/Structure Inspection 1/6/14 Truss A07 (North side) missing some bracing (labeled different on truss details). Some studs have almost no bearing on bottom plate due to notching. Some nuts are barely onto anchor bolt. Foundation vent not cut open in insulation NW corner and sides. No hour separation in crawl space (not req'd by code - get approval of designer). Submit information on Foundation vents. Backing needed for vertical grab bars (ADA). Inspector Comments: 01/13/2014N/ASAUREY AMANDAPlumbing Underground Inspection 01/13/2014PassQuinton OwensInsulation Inspection insulation good, window v factor = .29 blown fiberglass at ext. walls 2" foam board (cont) in crawl space. windows/doors sealed around perimeter. *2 front large windows not sealed. No 1hr rating behind shower. (not required by code) check with architect for design. Inspector Comments: 01/13/2014PassDon AllenPlumbing Sewer 01/13/2014N/ADon AllenRadon-Ground Inspection Page 1 of 3 (Continued) Permit Details Permit Number: 13-00294 Edward Jones Office 526 FIRST AMERICAN CIR Building - Commercial Permit Status of (Expired) as of Report Date: 01/17/2017 8:47 am Permit Inspection Summary 01/13/2014PassDon AllenPlumbing Water 01/13/2014PassDon AllenPlumbing Rough-in All good to cover the rough inInspector Comments: 01/13/2014PassDon AllenHVAC Rough-in All good to cover the rough in gas presser held at 20 lb on both lines Inspector Comments: 01/16/2014PassQuinton OwensSheetrock/Drywall Inspection drywall ok to tape (all 5/8" type x) *front wall with large window (larger cavities above arch covered - perimeter not sealed). Inspector Comments: 01/18/2014PassQuinton OwensFraming/Structure Inspection Framing reinspect, anchor bolt - main level items completed. crawl space still requires re-inspection. (added as condition for final) see misccondition 2. Inspector Comments: 03/18/2014PassDon AllenPlumbing Final Inspection all good for c/oInspector Comments: 03/18/2014PassDon AllenHVAC Final Inspection all good for the c/oInspector Comments: 04/11/2014FailQuinton OwensBuilding Final Anchor bolts missing on interior bearing walls in crawl space. North half of crawl space missing vapor barrier, which now has a mold problem. Gas line pressure regulator, not vented outside, is not mounted horizontal and upright as required. Landscaping must be done to comply with flood plain requirements (see diagram attached to email). Flood Elevation certificate to be done on existing construction. Building still locked (except mech room), could not inspect inside tenant space. Inspector Comments: 06/12/2015FailQuinton OwensCommercial Building Final Anchor bolts still missing on interior bearing walls in crawl space.Inspector Comments: Electrical Inspection Type 12/31/2013PassBret StoddardElectrical Rough-in Approved for cover in south portion of building only.Inspector Comments: 04/09/2014PassBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection Approved for a final and C.O.-Edward Jones portion, no A/C units installed, need to strap conduits for main service, will inspect on final of next portion. Inspector Comments: Mechanical Inspection Type 01/13/2014PassDon AllenGas Pressure Test pressure test good on both sides for 20 psi - see Don A. rough in inspection notesInspector Comments: 02/20/2014PassDon AllenGas Pressure Test gas presser held at 60 lb on the east side of the meter barInspector Comments: Page 2 of 3 (Continued) Permit Details Permit Number: 13-00294 Edward Jones Office 526 FIRST AMERICAN CIR Building - Commercial Permit Status of (Expired) as of Report Date: 01/17/2017 8:47 am Permit Inspection Summary Inspections Required Public Works Final Inspection Planning and Zoning Final Inspection Sidewalk Inspection Commercial Building Final Page 3 of 3