Loading...
HomeMy WebLinkAboutALL DOCS - 13-00296 - 455 S 2nd E #702 - University Courtyard - Stair RemodelPermit Inspection Summary Permit Status of (Expired) as of Report Date: 01/12/2017 11:27 am Permit Details Permit Number: 13-00296 University Courtyard - Stair Remodel 455 S 2ND E, #702 Commercial Remodel Permit Issued Date: 08/27/2013 Permit Inspection Statistics 3Total Inspections Completed: 0Total Inspections Passed: Inspection Pass Rate 0.00% Permit Inspection History *Refer to Individual Inspection Report for more Details 10/23/2013N/ATed DyeFooting Inspection 10/23/2013FailTed DyeFraming/Structure Inspection -Building #1: Bottom riser 12" Upper flight bottom riser 3" all other risers a 7 ". -Building #2: Bottom riser at 10" all others at 7" -building #3: Bottom step does not the same riser height. bottom tread is 7-1/2"...bottom step of mid riser at mid landing height is 8-3/4 and has a gap of 4" from landing to front edge of step. -Building #4 Bottom riser is 6" with other steps at 7". At mid level the riser at bottom of upper stairs is6" and upper top riser is 7-1/2.all other risers at 7" -building#5 bottom riser 9-1/2"" upper is 7-1/2". Upper set of stairs OK... -Building #6 Bottom riser 8-3/4". Upper flight has a 4" gap from landing to first riser riser height is 12". -Club house.....bottom riser is 14" handrail is top 33-1/2 to 27" bottom. Inspector Comments: 10-23-13 as of this date....Buildings 3,4,5,6 riser height are all OK building 6 has handrail issues Inspector Comments: 11/04/2013FailTed DyeFraming/Structure Inspection Building 1and 2 steps good Stairs to apt 703 good but handrail needs to be higher. hand rails on all stairs need to be a minimum of 34" Inspector Comments: Inspections Required Building Final Framing/Structure Inspection