Loading...
HomeMy WebLinkAboutMISC DOCS - 13-00337 - 125 E 2nd S - Windsor Manor, LLC - Site PlanPermit Review Summary Permit Status of (EXPIRED) as of Report Date: 01/11/2017 10:16 am Application Details Permit Application Number: 13-00337 Windsor Manor, LLC - Site Plan 125 East 2nd South Site Plan Review History *Refer to Individual Review Reports for more Details Application Review 10/04/2013Application Review - Site Plan SAUREY AMANDA APPROVED Fire Dept. Review 10/17/2013Fire Department Review - Site Plan Dale Pickering APPROVED Planning & Zoning Review 10/08/2013Planning and Zoning Review - Site Plan Natalie Powell REVISIONS 01/16/2014Planning and Zoning Review - Site Plan Natalie Powell APPROVED Public Works Review 11/06/2013Public Works Review - Site Plan Joel Gray REVISIONS 12/31/2013Public Works Review - Site Plan Joel Gray APPW/COND Review Report Current Public Works Review - Site Plan Status: APPW/COND Application Number: 13-00337Permit Details Application Received Date: 08/22/2013 Site Plan Application Approved Date: Application Approved Status: APPROVED 10/04/2013 125 East 2nd South Windsor Manor, LLC - Site Plan Status of Plan Reviews Completed 10/08/2013REVISIONSPlanning and Zoning Review - Site Plan 10/17/2013APPROVEDFire Department Review - Site Plan 11/06/2013REVISIONSPublic Works Review - Site Plan 12/31/2013APPW/CONDPublic Works Review - Site Plan 01/16/2014APPROVEDPlanning and Zoning Review - Site Plan Permit Review Status Plan Reviews Still in Progress DESCRIPTION COMMENTS STA TUS *Please respond to "REVISIONS" status items, with appropriate comment/documentation as needed! Water : Valve placement N/ANo valves shown on plans. Water : Services to lot(s)N/AWhere does 6" line connect to building? Water : Bury depth N/APlans state 4' and 5' minimum bury depth. Must be 5'. Water : Pipe Type N/AConcerned about elbows prior to vault. Does 4" from above tie into vault? Sewer: Services to lot(s)N/AWhy retain stairs at retaining wall to be removed? Storm : Catch basin type N/A Storm : Infiltrators N/A Site Lighting : Dark sky compliant N/A Site Lighting : Pole height N/A Parking Lot : Drainage N/A Parking Lot: Accessibility/layout On grade parking appears larger than opening in structure. COMPLETED Site Lighting : Photometric layout No site lighting submitted.COMPLETED Reviewed By: Joel Gray Review Date: 12/31/2013 Plan Review Details joel.gray@rexburg.org Public Works Review - Site Plan Status: APPW/COND Page 1 of 2 Public Works Review - Site Plan (Continued) D ESCRIPTIO N CO MMEN TS STATUS Water : DI class 50 in right of way Snow storage? (ramps and by building #3)COMPLETED Water : Connection to main line COMPLETED Storm : Drainage calcs COMPLETED Storm : On-site retention Retention is less than required amount.COMPLETED Storm : Connection to main line COMPLETED Storm : Manhole spacing COMPLETED Street : Sidewalk setback/continuos Sidewalk to be continuous across approaches. 6" Granular borrow under walk and 12" under curbing. COMPLETED Street : Street wdith/cross slove/running slope Civil plan does not match other sections. Asphalt road section to be: match existing asphalt depth (21/2" min.), 3 1/2" of 3/4" crushed, 12" of pit run. COMPLETED Street : Curb type 2nd South curb to be replaced only where it is low back or new approach is required. COMPLETED Street : Entrance placement Concrete approach required.COMPLETED Street : Lithium in all concrete Concrete in right of way requires lithium.COMPLETED Sewer: Line size/slope/type materials Sanitary sewer line is unmaintainable. Inverts above finished grade. Is line under building #3? COMPLETED Sewer: Manhole placement COMPLETED Sewer: Connection to mainline COMPLETED Page 2 of 2