Loading...
HomeMy WebLinkAboutALL DOCS - 13-00422 - Ying Yang - RemodelPermit Inspection Summary Permit Status of (Issue) as of Report Date: 01/10/2017 11:51 am Permit Details Permit Number: 13-00422 Ying Yang - Remodel 248 South 2nd West Commercial Remodel Permit Issued Date: 03/12/2014 Permit Inspection Statistics 15Total Inspections Completed: 8Total Inspections Passed: Inspection Pass Rate 53.33% Permit Inspection History *Refer to Individual Inspection Report for more Details Building Inspection Type 05/02/2014FailTed DyeFooting Inspection - Dig footings 2' square at bottom of footing as per plans. -Tie rebar and support off of ground. -One footing had no rebar in it. Inspector Comments: 05/06/2014PassTed DyeFooting Inspection 10/29/2015FailQuinton OwensCommercial Building Final DID NOT CALL FOR ANY FRAMING INSPECTION. Entry threshold too high for accessible entry (landing with ramp needed at door). Door handles for accessibility shall not require tight grasping, pinching, or twisting of the wrist to operate. Counter height issue: Owner said customers with disabilities will be provided service as needed by employees (they will be waited on similar to other dine in restaurants). Inspector Comments: 04/14/2016PassQuinton OwensCommercial Building Final Fire Dept. final inspection to be completed for Certificate of Occupancy.Inspector Comments: Electrical Inspection Type 10/29/2015FailBret StoddardCOM, COM-A, COM-R, and COM-T Electrical Final Inspection 04/14/2016PassBret StoddardElectrical Final Inspection COM-A,R,T Fire Inspection Type 10/29/2015FailDale PickeringFire Sprinkler Final Inspection 05/02/2016FailDale PickeringFire Department Final Inspection 06/07/2016PassDale PickeringFire Department Final Inspection Page 1 of 2 (Continued) Permit Details Permit Number: 13-00422 Ying Yang - Remodel 248 South 2nd West Commercial Remodel Permit Status of (Issue) as of Report Date: 01/10/2017 11:51 am Permit Inspection Summary Mechanical Inspection Type 03/19/2015FailDon AllenHVAC Rough-in The fire wrap on the exhaust duct going out needs to be wraped 2 times the needs 2 s.s. bands on the out layer duct and fire wrap need to exstend 18 inched above the highest part of thr roof Need to provide that the exhaust fan will pull at least 4688 cfm. Need to check the welds on the hood exhaust when finished. Call for the reinspect Inspector Comments: 03/20/2015PassDon AllenHVAC Rough-in 07/29/2015PassQuinton OwensGas Pressure Test 10/29/2015PassQuinton OwensHVAC Final Inspection Don did initial inspection and asked me to check if sheet metal continued behind hood above ceiling grid (it did extend above hood). Inspector Comments: Plumbing Inspection Type 03/12/2014PassDon AllenPlumbing Rough-in all goodInspector Comments: 10/29/2015FailDon AllenPlumbing Final Inspection need to install a backflow on the icemaker. need to change the grade on the drain for the icemaker. need to add a t&p on the water heater. Inspector Comments: 04/19/2016PassDon AllenPlumbing Final Inspection GOOD FOR THE C/OInspector Comments: Page 2 of 2