HomeMy WebLinkAboutCO, ALL DOCS - 16-00049 - 450 S Physical Plant Way - BYUI Upper Field RestroomsCertificate of Occupancy
City of Rexburg
Department of Community Development
35 N. 1st E. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Building Permit No:
Applicable Addition of Code:
Site Address:
Use and Occupancy:
Design Occupant Load:
Sprinkler System Required:
Name and Address of Owner:
IBC/IRC 2009
16-00049
450 S Physical Plant Way
BYU-Idaho Upper Field Restrooms
N/A
BYU IDAHO
525 S Center St
REXBURG, ID 83460
Contractor: Zwick Construction
Special Conditions:
Occupancy: Utility, miscellaneous = 2,400.00 sq. ft.
This Certificate, issued persuant to the requirements of Section 109 of the International Building
Code, certifies that, at the time of issuance, this building or that portion of the building that was
inspected on the date listed was found to be in compliance with the requirements of the code for the
group and division of occupancy and the use for which the proposed occupancy was classified.
Date C.O. Issued: _____ / _______ / ______
C.O. Issued by: __________________________ Building Inspector: __________________________
There shall be no further change in the existing occupancy classification of the building nor shall any structural changes,
modifications or additions be made to the building or any portion thereof until the building Official has reviewed and
approved said future changes.
Mechanical Inspector: Fire Alarm:
Plumbing Inspector: Fire Dept./Sprinkler:
Electrical Inspector: P&Z/Public Works:
8 26 16
N/A
N/A N/A
N/AN/A
N/A
COMcheck Software Version 4.0.2.8
Envelope Compliance Certificate
Project Title:
2012 IECC
Project Type:New Construction
Vertical Glazing / Wall Area:1%
Location:Rexburg, Idaho
Climate Zone:6b
Construction Site:
BYU-I South Playing Fields
Rexburg, ID 83460
Owner/Agent:
BYU-Idaho
Rexburg, ID
Designer/Contractor:
Joe Millilo
CRSA
649 South Temple
Salt Lake City, UT 84101
8013555915
joe@crsa-us.com
Project Information
Energy Code:
Upper Playing Fields Support Facility
Building Area Floor Area
1-School/university : Nonresidential 1831
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof 1: Insulation Entirely Above Deck, [Bldg. Use 1 - School/university]1753 ---30.0 0.032 0.032
Roof 2: Insulation Entirely Above Deck, [Bldg. Use 1 - School/university]458 ---20.0 0.048 0.032
Exterior Wall 1: Concrete Block:8", Partially Grouted, Cells Empty, Light
Density, Furring: Metal, [Bldg. Use 1 - School/university]
2263 0.0 15.0 0.054 0.078
Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Energy
code default, Double Pane with Low-E, Clear , SHGC 0.70, [Bldg. Use 1
- School/university]
21 ------0.650 0.360
Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370
Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370
Door 3: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370
Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370
Door 5: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]25 ------0.650 0.370
Door 6: Insulated Metal, Non-Swinging, [Bldg. Use 1 - School/university]59 ------0.125 0.125
Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 -
School/university] (b)
187 ---10.0 0.550 0.550
Additional Efficiency Package
High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist
report.
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Project Title:
Data filename:
Upper Playing Fields Support Facility
P:\B15-079 BYU-I 4-Plex Support Facility\06- DESIGN\06- Code\15-079 COMcheck.cck
04/01/16Report date:
91 ofPage
COMcheck Software Version 4.0.2.2
Mechanical Compliance Certificate
Project Title:
90.1 (2010) Standard
Project Type:New Construction
Location:Rexburg, Idaho
Climate Zone:6b
Construction Site:
Rexburg, ID
Owner/Agent:
Brigham Young University Idaho
Rexburg, ID
Designer/Contractor:
CRSA Architecture
649 E South Temple
Salt Lake City, UT 84102
801.355.5915
Project Information
Energy Code:
BYU-I Playing Fields Support Facility South Playing Fields
Mechanical Systems List
Quantity System Type & Description
Split System Heat Pump
Heating Mode: Capacity = 13 kBtu/h,
Proposed Efficiency = 9.50 HSPF, Required Efficiency = 7.70 HSPF
Cooling Mode: Capacity = 18 kBtu/h,
Proposed Efficiency = 15.30 SEER, Required Efficiency = 13.00 SEER
Fan System: FAN SYSTEM 1 | SAC-1 -- Compliance (Motor nameplate HP method) : Fails: Fan system has no supply fan
Fans:
FAN 1 Terminal Unit, Constant Volume, 425 CFM, 0.3 motor nameplate hp
1 HVAC System 1 - SAC-1 (Single Zone):
Heating: 4 each - Unit Heater, Electric, Capacity = 10 kBtu/h
No minimum efficiency requirement applies
Fan System: None
4 HVAC System 2 - EWH-1 to 4 (Unknown):
Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h
No minimum efficiency requirement applies
Fan System: None
1 HVAC System 3 - EWH-5 (Unknown):
Heating: 1 each - Unit Heater, Electric, Capacity = 17 kBtu/h
No minimum efficiency requirement applies
Fan System: None
1 HVAC System 4 - EWH-6 (Unknown):
Heating: 1 each - Unit Heater, Electric, Capacity = 17 kBtu/h
No minimum efficiency requirement applies
Fan System: FAN SYSTEM 2 | EUH-1 -- Compliance (Motor nameplate HP method) : Fails: Fan system has no supply fan
Fans:
FAN 2 Terminal Unit, Constant Volume, 350 CFM, 0.3 motor nameplate hp
1 HVAC System 5 - EUH-1 (Unknown):
Electric Storage Water Heater, Capacity: 10 gallons
No minimum efficiency requirement applies
1 Water Heater 1:
Project Title:
Data filename:
BYU-I Playing Fields Support Facility South Playing Fields
J:\Project Files\2015 Jobs\15119 - CRSA BYUI Upper Playing Field Support
Building\ENG\Comcheck\BYUI Playing Fields.cck
03/29/16Report date:
121 ofPage
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title:
Data filename:
BYU-I Playing Fields Support Facility South Playing Fields
J:\Project Files\2015 Jobs\15119 - CRSA BYUI Upper Playing Field Support
Building\ENG\Comcheck\BYUI Playing Fields.cck
03/29/16Report date:
122 ofPage
3/29/16LARRY D. VEIGEL, P.E.
COMcheck Software Version 4.0.2.2
BYU-I CAMPUS
REXBURG, ID
BYU-IDAHO
ID
Payne Engineering
1823 E. Center Street
Pocatello, ID 83201
208-232-4439
Project Title:
Data filename: UPPER PLAYING FIELDS SUPPORT FACILITY
\\PESERVER\Payne Engineering Data\2015\BYUI Play Fields Support Facility -
1582\05_Calculations\Comcheck\BYUI_Playfields Support Facility.cck
03/29/16 Report date:
2 1 of Page
Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications,
and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC
requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the Inspection Checklist.
Mike Payne, Designer Mike Payne 03/29/2016
Name - Title Signature Date
Project Title:
Data filename: UPPER PLAYING FIELDS SUPPORT FACILITY
\\PESERVER\Payne Engineering Data\2015\BYUI Play Fields Support Facility -
1582\05_Calculations\Comcheck\BYUI_Playfields Support Facility.cck
03/29/16 Report date:
2 2 of Page