Loading...
HomeMy WebLinkAboutCO, ALL DOCS - 16-00049 - 450 S Physical Plant Way - BYUI Upper Field RestroomsCertificate of Occupancy City of Rexburg Department of Community Development 35 N. 1st E. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Building Permit No: Applicable Addition of Code: Site Address: Use and Occupancy: Design Occupant Load: Sprinkler System Required: Name and Address of Owner: IBC/IRC 2009 16-00049 450 S Physical Plant Way BYU-Idaho Upper Field Restrooms N/A BYU IDAHO 525 S Center St REXBURG, ID 83460 Contractor: Zwick Construction Special Conditions: Occupancy: Utility, miscellaneous = 2,400.00 sq. ft. This Certificate, issued persuant to the requirements of Section 109 of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on the date listed was found to be in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancy was classified. Date C.O. Issued: _____ / _______ / ______ C.O. Issued by: __________________________ Building Inspector: __________________________ There shall be no further change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the building Official has reviewed and approved said future changes. Mechanical Inspector: Fire Alarm: Plumbing Inspector: Fire Dept./Sprinkler: Electrical Inspector: P&Z/Public Works: 8 26 16 N/A N/A N/A N/AN/A N/A COMcheck Software Version 4.0.2.8 Envelope Compliance Certificate Project Title: 2012 IECC Project Type:New Construction Vertical Glazing / Wall Area:1% Location:Rexburg, Idaho Climate Zone:6b Construction Site: BYU-I South Playing Fields Rexburg, ID 83460 Owner/Agent: BYU-Idaho Rexburg, ID Designer/Contractor: Joe Millilo CRSA 649 South Temple Salt Lake City, UT 84101 8013555915 joe@crsa-us.com Project Information Energy Code: Upper Playing Fields Support Facility Building Area Floor Area 1-School/university : Nonresidential 1831 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1: Insulation Entirely Above Deck, [Bldg. Use 1 - School/university]1753 ---30.0 0.032 0.032 Roof 2: Insulation Entirely Above Deck, [Bldg. Use 1 - School/university]458 ---20.0 0.048 0.032 Exterior Wall 1: Concrete Block:8", Partially Grouted, Cells Empty, Light Density, Furring: Metal, [Bldg. Use 1 - School/university] 2263 0.0 15.0 0.054 0.078 Window 1: Metal Frame with Thermal Break:Fixed, Perf. Type: Energy code default, Double Pane with Low-E, Clear , SHGC 0.70, [Bldg. Use 1 - School/university] 21 ------0.650 0.360 Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370 Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370 Door 3: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370 Door 4: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]21 ------0.650 0.370 Door 5: Insulated Metal, Swinging, [Bldg. Use 1 - School/university]25 ------0.650 0.370 Door 6: Insulated Metal, Non-Swinging, [Bldg. Use 1 - School/university]59 ------0.125 0.125 Floor 1: Slab-On-Grade:Unheated, Vertical 2 ft., [Bldg. Use 1 - School/university] (b) 187 ---10.0 0.550 0.550 Additional Efficiency Package High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Project Title: Data filename: Upper Playing Fields Support Facility P:\B15-079 BYU-I 4-Plex Support Facility\06- DESIGN\06- Code\15-079 COMcheck.cck 04/01/16Report date: 91 ofPage COMcheck Software Version 4.0.2.2 Mechanical Compliance Certificate Project Title: 90.1 (2010) Standard Project Type:New Construction Location:Rexburg, Idaho Climate Zone:6b Construction Site: Rexburg, ID Owner/Agent: Brigham Young University Idaho Rexburg, ID Designer/Contractor: CRSA Architecture 649 E South Temple Salt Lake City, UT 84102 801.355.5915 Project Information Energy Code: BYU-I Playing Fields Support Facility South Playing Fields Mechanical Systems List Quantity System Type & Description Split System Heat Pump Heating Mode: Capacity = 13 kBtu/h, Proposed Efficiency = 9.50 HSPF, Required Efficiency = 7.70 HSPF Cooling Mode: Capacity = 18 kBtu/h, Proposed Efficiency = 15.30 SEER, Required Efficiency = 13.00 SEER Fan System: FAN SYSTEM 1 | SAC-1 -- Compliance (Motor nameplate HP method) : Fails: Fan system has no supply fan Fans: FAN 1 Terminal Unit, Constant Volume, 425 CFM, 0.3 motor nameplate hp 1 HVAC System 1 - SAC-1 (Single Zone): Heating: 4 each - Unit Heater, Electric, Capacity = 10 kBtu/h No minimum efficiency requirement applies Fan System: None 4 HVAC System 2 - EWH-1 to 4 (Unknown): Heating: 1 each - Unit Heater, Electric, Capacity = 7 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 3 - EWH-5 (Unknown): Heating: 1 each - Unit Heater, Electric, Capacity = 17 kBtu/h No minimum efficiency requirement applies Fan System: None 1 HVAC System 4 - EWH-6 (Unknown): Heating: 1 each - Unit Heater, Electric, Capacity = 17 kBtu/h No minimum efficiency requirement applies Fan System: FAN SYSTEM 2 | EUH-1 -- Compliance (Motor nameplate HP method) : Fails: Fan system has no supply fan Fans: FAN 2 Terminal Unit, Constant Volume, 350 CFM, 0.3 motor nameplate hp 1 HVAC System 5 - EUH-1 (Unknown): Electric Storage Water Heater, Capacity: 10 gallons No minimum efficiency requirement applies 1 Water Heater 1: Project Title: Data filename: BYU-I Playing Fields Support Facility South Playing Fields J:\Project Files\2015 Jobs\15119 - CRSA BYUI Upper Playing Field Support Building\ENG\Comcheck\BYUI Playing Fields.cck 03/29/16Report date: 121 ofPage Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 90.1 (2010) Standard requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: BYU-I Playing Fields Support Facility South Playing Fields J:\Project Files\2015 Jobs\15119 - CRSA BYUI Upper Playing Field Support Building\ENG\Comcheck\BYUI Playing Fields.cck 03/29/16Report date: 122 ofPage 3/29/16LARRY D. VEIGEL, P.E. COMcheck Software Version 4.0.2.2       BYU-I CAMPUS REXBURG, ID  BYU-IDAHO ID  Payne Engineering 1823 E. Center Street Pocatello, ID 83201 208-232-4439                                                                                     Project Title: Data filename: UPPER PLAYING FIELDS SUPPORT FACILITY \\PESERVER\Payne Engineering Data\2015\BYUI Play Fields Support Facility - 1582\05_Calculations\Comcheck\BYUI_Playfields Support Facility.cck 03/29/16 Report date: 2 1 of Page  Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2012 IECC requirements in COMcheck Version 4.0.2.2 and to comply with the mandatory requirements listed in the Inspection Checklist. Mike Payne, Designer Mike Payne 03/29/2016 Name - Title Signature Date  Project Title: Data filename: UPPER PLAYING FIELDS SUPPORT FACILITY \\PESERVER\Payne Engineering Data\2015\BYUI Play Fields Support Facility - 1582\05_Calculations\Comcheck\BYUI_Playfields Support Facility.cck 03/29/16 Report date: 2 2 of Page