As requested, MTI performed density testing in accordance with current applicable standards. Required
compaction is95oh. The results obtained are as follows:
.
Comp.
Test
11t
Location & Depth
*All tests taken using Backscatter method
Floor slab of new purchasing room, top of base: l6' south
and 30' west ofnortheast room corner
Wet Percent Dry Mat'I.
Density Moisture Density Type
Pass/
Fail
I
2
J
l0' west and 15' east of southwest room corner 130.0 2.7
12' eastand 2' south of entry way on west side of room 130.3 3.6
Method of testing: BS is Backscatter; Depth in inches is Direct Transmission
Material Type: 1: l27.0pcf @ 8.0Yo Native - native pit run with silt and sand (P2871)
Gauge Information:
MTI #: 44 Make & Model: Troxler 3430 27576 Standard Counts: DS: 2351
27s1 S. Victory view wayleoG;lD-E3763 208-376-4748 Fax:20ffi
t30.2 3.6 12s.6 I
126.6 I
125.8 I
99 Pass
100 Pass
99 Pass
ASTM D-1557
If you have questions concerning this report (rpt3 lOmd.doc), please contact us immediately.
Respectfully submitted,
MATERIALS TESTING & INSPECTION. INC.
4
Reviewed by: JasonTaylor, E.I.T.
StaffEngineer
CC: Mark Harrison, Madison Memorial Hospital; Mike Buehner, Reaveley Engineers; Jon Erdmann, Architectural Nexus, Inc.; Okland Construction;
Val Christensen, City of Rexburg Building Department
Email: mti@mti-id.com Website: www.mti-id.com