HomeMy WebLinkAboutORDINANCE NO. 851 EXISTING BUILDING LIFE SAFETY ORDINANCEORDINANCE NO.
AN ORDINANCE OF THE CITY OF REXBURG, MADISON COUNTY,
IDAHO, KNOWN AS "EXISTING BUILDINGS LIFE SAFETY
ORDINANCE", SETTING FORTH THE SCOPE OF APPLICATION FOR
THIS ORDINANCE; PROVIDING GUIDELINES TO BE FOLLOWED BY
THE BUILDING DEPARTMENT OF THE CITY OF REXBURG IN
EVALUATING EXISTING STRUCTURES INTENDED FOR RENT AS
RESIDENTIAL UNITS; PROVIDING FOR AN APPEAL PROCESS;
PROVIDING FOR FEES; PROVIDING PENALTIES FOR FAILURE TO
COMPLY WITH ANY PROVISIONS OF THIS ORDINANCE AND
SETTING FORTH A VIOLATION OF THIS ORDINANCE
CONSTITUTES A MISDEMEANOR; PROVIDING A SAVINGS CLAUSE;
PROVIDING FOR SEVERABILITY; REPEALING ALL ORDINANCES
AND PARTS OF ORDINANCES IN CONFLICT HEREWITH; AND
PROVIDING AN EFFECTIVE DATE HEREOF.
BE IT ORDAINED BY THE MAYOR AND CITY COUNCIL OF THE CITY
OF REXBURG IDAHO:
SECTION I: Scope of Application
The following is a non-inclusive list of life safety issues for all existing apartment
buildings in the Rexburg City Limits. This list is for existing apartments only. All new
apartments and existing buildings being converted to apartments shall be built in
accordance with the Codes that are in place at the time the structure is built. The purpose
of this Ordinance is to provide a reasonable degree of safety to persons occupying
existing apartment buildings built and/or converted prior to 1985. Apartments built or
converted after 1/1/85 shall comply with the code and Ordinances in place at the time of
construction or conversion.
SECTION II: Life Safety Issues
Every floor above the first story or basement used as apartments serving over 12
persons shall have a minimum of two exits. One of these exits for an upper floor
may be a fire escape built to the standards set forth in Section 3407.4 of the 1997
Uniform Building Code (UBC), which is attached to the back of this document.
An exit ladder device may be used in lieu of a fire escape when approved by the
City of Rexburg Fire Department. For apartment units requiring two exits that
have a floor level of not more than 20 feet above grade and basements apartments
requiring two exits, one exit will be allowed when all bedrooms have egress
windows that meet the requirements of item No. 8 in this list, but also must have a
minimum opening area of 5.7 square feet. All doors or windows providing access
to a fire escape shall be provided with fire escape signs. Exit signs shall be
provided at exits where more than one exit is required and in corridors used for
exiting from multiple units. Exit signs shall be as per the 1997 Uniform Building
Code. Primary entrance to an apartment is not allowed through a garage. A one-
hour firewall may be erected to separate the apartment entrance from the garage.
If a door is needed from the apartment entrance firewall to the interior of the
garage, it must be a door as described in item No. 3 below. ,
All stairs used as part of an exit shall have a maximum riser height of 8", a
minimum run of 9" and a minimum width of 30" (exclusive of handrails). An 8-
1/2" riser will be allowed if the minimum tread is increased to 10". Every
stairway with over 3 risers shall be provided with a handrail. All stairs require
landings with a minimum dimension of 30" run in direction of travel at each point
of access to stairwell. All stairwells will have a minimum 6'6" headroom.
3. Exit corridors serving occupant loads of 30 or more occupants shall have walls
and ceilings of not less than one-hour fire resistive construction. Wood lath and
plaster or 1/2" drywall in good condition are permitted as substitution for one layer
of 5/8" type X drywall in corridor construction. Openings with fixed wired glass
Ordinance No.
-1-
set in steel frames are allowed in corridors. Doors entering in to corridors (with
exception of those opening directly outside) shall be 20 -minute fire rated
assemblies, or solid wood doors not less than 1 '/4" thick. Where the existing
frames will not accommodate a 1 '/4" thick solid wood door, a 1 3/8" thick solid
bonded wood -core door or equivalent insulated steel door shall be permitted.
Doors shall be self-closing or automatic closing by smoke detectors. Transoms
must be covered with ''/2 ' drywall unless approved by the City Building Official.
The City Building Official may nullify the above corridor requirements when an
approved sprinkler system is provided.
4. Interior vertical shafts, including but not limited to stairways, elevator hoistways,
service and utility shafts, shall be enclosed by a minimum of one-hour fire -
resistive construction. All openings into such shafts shall be protected with one-
hour fire assemblies that shall be maintained self-closing or be automatic closing
by smoke detection. All other openings shall be fire protected in an approved
manner. Existing fusible link -type automatic door -closing devices may be
permitted if the fusible link rating does not exceed 135 F (57.2C).
EXCEPTIONS:
a. An enclosure is not required for openings serving one adjacent
floor.
b. Vertical openings need not be protected if the building is protected
by an approved automatic sprinkler system.
An approved sprinkler system shall be installed in basements or stories exceeding
1,500 square feet of habitable area and not having a minimum 30"x 80" door or a
minimum 30"x 42" window in every 50 lineal feet of exterior wall (or fraction
thereof) on at least one side of the building. A sprinkler system shall be installed
in any portion of the basement or upper story that is over 75 feet from opening as
described above.
6. One hour dwelling separation shall be provided between all apartment units.
Wood lath and plaster and 1/2" drywall is acceptable as one hour separation when
in good shape and continuous on both sides of walls and on ceilings, provided the
floors above are of a double layer variety. Buildings with sprinkler systems have
different area separation requirements. Consult the City of Rexburg Building
Official for more information.
Window egress is required. Each bedroom will have a window that meets the
minimum size requirements of 20" wide, 22" high. The windows will not be
required to meet the minimum opening area of 5.7 square feet. A permanent
object (foot locker or seat) will be allowed to be built against a wall below a
window to allow sill heights greater than 44". Window wells are required to have
a clear opening 24" in front of window and to have steps if window well is deeper
than 44". Door hardware must not be able to be locked so that it cannot be
opened from the inside without the use of a key or some special knowledge.
Aisles, corridors and hallways or any part of the exit, exit access or exit discharge
shall not be blocked and shall be a minimum of 30" wide. Stairs shall be secure.
Guardrails shall be installed at any walking surface adjacent to a drop of 30" or
greater. Doors or any part of exit, exit access or exit discharge to be in operable
condition.
8. Exits and access to fire extinguishers shall be unobstructed. Garbage and trash
need to be removed from the premises on a timely basis. Outside trash containers
must be kept at a proper distance from buildings for fire safety.
9. All apartments shall be equipped with an approved wall mounted fire
extinguisher. The minimum size is a 2A-10BC, unless a smaller IA extinguisher
already exists. The existing IA shall be replaced when it is 6 years old with a 2A-
1 OBC, therefore, all apartments 1A fire extinguishers shall be replaced before 6
years from the adoption date of this Life Safety Code. The extinguisher shall be
mounted in a conspicuous location near the kitchen. Extinguishers must also be
accessible in common areas such as computer rooms, lounges, game rooms,
Ordinance No.
-2
laundry rooms, etc. Extinguishers shall have monthly inspections by owners or
manager. Apartment owners or managers shall create and maintain a program for
monthly extinguisher inspections.
10. Smoke detectors shall be provided in each sleeping room and one additional
detector at each floor of each unit. The detectors shall be placed on a wall near
ceiling but not closer than 6"of the ceiling. Smoke detectors may be battery
operated or may receive their primary power from the building wiring when such
wiring is served from a commercial source. Wiring shall be permanent and
without disconnecting switches other than those required for overcurrent
protection. Each apartment owner or manager shall check detectors monthly for
operation and for battery function. Apartment owners or managers must create,
maintain and document a program for monthly detector inspection.
11. Romex or other wire for greater than 100 volt use shall be encased in a wall, floor,
ceiling cavity or in any NEC approved conduit or chase. Open wiring is not
allowed. Electrical panels must not be blocked or obstructed in any manner.
Electrical panel doors must be able to be closed and latched. All openings in the
service panels must be plugged. All outlets and switches will have covers. All
electrical connections will be provided with a junction box and cover. No frayed
wires will be allowed. All outlets in bathrooms, kitchens, garages and outdoors to
be replaced with ground fault devices. Improperly sized fuses or breakers must be
replaced with properly sized units. All wire entrances into metal boxes will be
made with NEC approved connectors. Over loaded panels must be replaced with
adequate service. Electrical conduits to be fastened securely to structure.
Overhead wires from out buildings to be at least 10' above any ground surface
(including decks or raised walking surfaces). All stairs between floors to be
provided with lighting. Exterior stairs to be provided with lighting. Heating
system shall not require the use of portable electric heaters to adequately heat
building. All light fixtures are required to have canopies and to be securely
attached to structure. Extension cords are not allowed to replace proper wiring.
Electrical in general to be in safe working manner. State Electrical Inspector to
inspect when any question arises.
12. Require all gas meters, pipes or appurtenances to be protected from vehicles.
Require combustion air to gas appliances located in small, unventilated rooms.
Require gas water heaters greater than 4' tall with flexible connections to be
strapped to structure. Require 2" minimum space for flue vents from any
combustible construction. Require 24" clear space in front of water heaters and
furnaces. This requirement may be met by the opening of a door or an access
panel. Gas water heaters or furnaces located in a bedroom or a bedroom closet
must be totally isolated from the bedroom with a tight fitting door and must
receive combustion air from an other source besides the bedroom. Require proper
clearance for heating equipment (water heaters and furnaces). Require that all high
efficiency gas furnace flue discharge points be located in areas that are not below
doors or windows that can be opened or within 4' from such windows or doors.
Storage or trash shall not be allowed within 24" of gas water heater or furnace.
Gas water heater and furnace flues must be connected with at least 3 screws at all
joints and must be tightly installed. Require that all gravity venting between 450
and 60° be considered as horizontal venting and require that the total run of
horizontal vent be less than 75% of the vertical height of the vent. Portable gas
heaters are not allowed. Corroded pressure relief valves must be replaced.
13. Require back flow prevention for lawn sprinkler systems.
14. All wooden structural components (headers, beams, columns, rafters, trusses,
joists, bearing walls etc.) to be free of stress cracks, fastened securely and free of
rot. Steel and concrete structural components (beams, columns, slabs, girders,
purlins, girders, footings, etc.) to be free from defects, stress cracks, strain or
fatigue that could cause loss of structural integrity. Roof to be without leaks.
15. Address must be posted on building so that it is clearly visible from the street in a
Ordinance No.
-3-
manner that is compliant with Emergency Services. Contact Emergency Services
for more information.
SECTION III: Administration and Appeal
The above list is not intended to address every safety issue that may present itself.
The inspector at his/her discretion may identify additional safety items that need to be
remedied. Situations may arise that can't be feasibly remedied to satisfy this list. If at
any time an owner or manager thinks that the inspection requests are excessive or
unnecessary he/she may submit the matter to the Rexburg U.B.C. Board of Appeals for
review. The Board will then make their recommendations to the City of Rexburg City
Council. The Council will have final say on the matter.
If the owner or manager of an apartment complex has reason to think that
alternative technology may satisfy the requirements of any of the Life Safety Issues,
he/she may submit the idea to the City of Rexburg Building Official for review. If the
Official rejects the alternative, the owner or manager may opt to submit the matter to the
Rexburg U.B.C. Board of Appeals for review. The Board will then make their
recommendations to the City of Rexburg City Council. The Council will have final say
on the matter.
The inspector will notify the State of Idaho Electrical Inspector if any electrical
problems exist that are out of the inspector's area of expertise. It is our intent to have
only one inspector represent the City of Rexburg at the time of inspection. The Fire
Department, the Building Department, the Water Department and Wastewater
Department will combine and supply training for one inspector from the Building
Department and one from the Fire Department. The intent is to have two trained
inspectors with one acting as regular and the other as a back-up.
All apartments seeking a new business License from the City of Rexburg shall be
inspected and given 3 months to establish a plan of compliance. The owner shall have
another 3 months to perform work, at which time an inspection by the City of Rexburg
shall be called for. License will not be granted until work is completed satisfactorily
according to the plan of compliance, at which time if owner is not compliant, such
premise shall be vacated. All apartment owners in the City of Rexburg not seeking a new
business license will be sent notices to supply the City of Rexburg Clerk with a proposal
for compliance within 18 months of notice. Initial inspections will be scheduled at this
time. Owners will have 3 years from original notice to complete work and have it
inspected by the City for compliance or such premise shall be vacated until made to
conform.
SECTION IV: Violation; Penalties: Any person who violates or fails to comply with
any of the provisions of this Ordinance or who, having obtained a permit hereunder,
wilfully fails to continue to comply with the conditions set forth in this ordinance is guilty
of a misdemeanor, and upon conviction thereof, may be fined in accordance with State
Statutes.
SECTION V: Repeal All ordinance and parts of ordinance in conflict with this
ordinance are hereby repealed.
SECTION VI: Savings Clause Neither the adoption of this ordinance nor the repeal of
any ordinance shall, in any manner, affect the prosecution for violation of such ordinance
committed prior to the effective date of this ordinance or be construed as a waiver of any
license or penalty due under any such ordinance or in any manner affect the validity of
any action heretofore taken by the City of Rexburg City Council or the validity of any
>uch action to be taken upon matter pending before the City Council on the effective date
Athis ordinance.
SECTION VII: Severability The provisions of this ordinance are severable and if any
provision, clause, sentence, subsection, word or part thereof is held illegal, invalid, or
a nconstitutional or inapplicable to any person or circumstance, such illegality, invalidity
)r unconstitutional or inapplicability shall not affect or impair any of the remaining
provisions, clauses, sentences, subsections, words or parts of this ordinance or their
application to other persons or circumstances. It is hereby declared to be the legislative
Ment that this ordinance would have been adopted if such illegal, invalid or
mconstitutional provision, clause sentence, subsection, word, or part had not been
)rdinance No.
-4-
included therein, and if such person or circumstance to which the ordinance or part
thereof is held inapplicable had been specifically exempt therefrom.
SECTION VII: Effective Date This Ordinance shall become effective upon passage by
the City Council, and proper publication in the newspaper of local jurisdiction.
PASSED BY THE CO UN L AICD APPROVED BY THE MAYOR THIS THE
/DAY OF m � , 2001.
ATTEST:
City Clerk
r.T
ars FfR.7
ss
of Madison )
I, Marilyn Hansen, City Clerk of the City of Rexburg, Idaho, do hereby certify that
above and foregoing is a full, true and correct copy of the Ordinance entitled:
AN ORDINANCE OF THE CITY OF REXBURG, MADISON COUNTY,
IDAHO, KNOWN AS "EXISTING BUILDINGS LIFE SAFETY
ORDINANCE", SETTING FORTH THE SCOPE OF APPLICATION FOR
THIS ORDINANCE; PROVIDING GUIDELINES TO BE FOLLOWED BY
THE BUILDING DEPARTMENT OF THE CITY OF REXBURG IN
EVALUATING EXISTING STRUCTURES INTENDED FOR RENT AS
RESIDENTIAL UNITS; PROVIDING FOR AN APPEAL PROCESS;
PROVIDING FOR FEES; PROVIDING PENALTIES FOR FAILURE TO
COMPLY WITH ANY PROVISIONS OF THIS ORDINANCE AND
SETTING FORTH A VIOLATION OF THIS ORDINANCE
CONSTITUTES A MISDEMEANOR; PROVIDING A SAVINGS CLAUSE;
PROVIDING FOR SEVERABILITY; REPEALING ALL ORDINANCES
AND PARTS OF ORDINANCES IN CONFLICT HEREWITH; AND
PROVIDING AN EFFECTIVE DATE HEREOF.
ssed the City Council and approved by the Mayor this the �a
, 2001.
No.
City
-5-
3407.4 Fire Escapes.
1. Existing fire escapes which, in the opinion of the building official, comply with the intent of
this section may be used as one of the required exits. The location and anchorage of fire escapes
shall be of approved design and construction.
2. Fire escapes shall comply with the following:
Access from a corridor shall not be through an intervening room.
All openings within 10 feet (3048 mm) shall be protected by three -fourths -hour fire assemblies.
When located within a recess or vestibule; adjacent enclosure walls shall be of not less than
one-hour fire -resistive construction.
Egress from the building shall be by a clear openinghaving aminimum dimension of notless than
29 inches (737 mm). Such openings shall be openable from the inside without the use, of a key or
special knowledge or effort. The sill of an opening giving access shall not be more than 30 inches
(762 mm) above the floor of the building or balcony.
Fire escape stairways and balconies shall support the dead load plus a live load of not less t4an
100 pounds per square foot (4.79 kN/m2) and shall be provided with a top and intermediate handrail
on each side. The pitch of the stairway shall not exceed 60 degrees with a minitnum width of 18
inches (457 mm). Treads shall not be less than 4 inches (102 mm) in width- and the rise between
treads shallnot exceed 10 inches (254 mm). All stair and balcony railings shall support a horizontal
force of not less than 50 pounds per lineal foot (729.5 N/m) of railing. -
Balconies shallnot be less than44 inches (1118 mm) inwidth withno floor opening other thanthe
stairway opening greater than 5/8 inch (16 mm) in width. Stairway openings in such balconies shall
not be less than 22 inches by 44 inches (599 mm by 1118 mm). Thebalustrade of each balcony shall
not be less than 36 inches (914 mm) high with not more than 9 inches (229 mm) between balusters.
Fire escapes shall extend to the roof or provide an approved gooseneck ladder between the top
floor landing and the roof when serving buildings four or more stories in height having roofs with
less than 4 units vertical in 12 units horizontal (33.3% slope). Fire escape ladders shall be designed
and connected to the building to withstand a horizontalforceof 1,00 pounds per lineal.foof(1459
N/m); each rung shall support a concentrated load of 500 pounds (2224 N) placed anywhere on the
rung. All ladders shall be at least 15 inches (381 mm) wide; located within 12 inches (305 mm) of
the building and shall be placed flatwise relative to the face of the building. Ladder rungs shall. be. _
3/4 inch(19 mm) in diameter and shall be located 12 inches (305 mm) on center. Openings for roof
access ladders through comites and similar projections shall have minimum dimensions of 30 in-
ches by 33 inches (762 mm by 838 mm).
The lowest balcony shall not be more than 18 feet (5486 mm) from the ground. Fire escapes shall
extend to the ground or be provided with counterbalanced stairs reaching to the ground
1-519
APPENDIX CHAPTER 34
1994 UNIFORM BUILDING CODE
Fire escapes shall not take the place of stairways required by the codes under which the building
was constructed -
Fire escapes shall be kept clear and unobstructed at all times and maintained in good Working
order.
3407.5 Exit and Fire Escape Signs. Exit signs shall be provided as required by this code.
EXCEPTION: The use of existing exit signs may be continued when approved by the building official.
All doors or windows providing access to a fire escape shall be provided with fire escape signs.