HomeMy WebLinkAboutREVIEW ACTION - 08-00554 - Artic Circle RemodelclTY ()1l Rr{*vRc Am@ i<.a s lilrs i it (1tntn, a itt P.O Box 280 19 E tr4ain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action December 18, 2008 Permit Number: 08 00554 Project Name: Arctic Circle Project Type: Commercial Review ltem Electrical Service Review Exiting Review Height and Area Review Accessibility Review Water and Sewer Service Building Code Fire Compliance Review Structural Review Mechanical Review Energy Conservation Compliance Review Complies with approved Site plan Review Plumbing Potable Water Review Approved Remodel Remodel The electrical plans that were submitted were very vague, therefore make sure that anything new is wired to the 2008 NEC and any questions call Bret at 359-3020x332. According to the plans that were submitted, no service change is going to take place-let us know if it is ASAP. Meets code requirements. Meets code requirements. Provide accessible restrooms as per IBC Section 3409.7. ldentify on plans. Male restroom needs grab bars, scald guard on sink and unisex sign for door. All plumbing services are required to be tested and inspected beforei covering. The materials used to make the "rubber floor" must meet the requirements of the 2006 International Building Code (tBC) and ASTM E 119. Have the footings, foundation, shearwalls, connections etc. been designed by an engineer? Provide Stamped drawings. ls mechanical being changed or added to? The COMcheck Envelope Compliance Certificate identifies R-10 inslulation at the slab. The plans do not show this insulation. Also, R- 50 is identified on the certificate and R-38 is shown on the plans. Please make the necessary changes. Allwater lines are required to be installed 11t13t2008 11t13t2008 11t20t2008 11t20t2008 11t25t2008 Electrical Circuits Review clTY {rtr RE{*VRG Amti.r\ llafril, < :ot ntnwlity P.O Box 280 19 E. lMain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action December 18,2008 Permit Number: 0B 00554 Project Name: Arctic Circle Remodel Project Type: Commercial Remodel Review ltem Approved Plumbing Storm Drain Review Plumbing Sewer Drain Review Parcel#'s according to the Uniform plumbing Code 2003edition. All strom drains are required to be tested andinspected before covering. All drains are required to be installed according to the Uniform Plumbing Code 2003 edition. RPRRXBIO174743 CITY OII RSXBT'RG (\!*. A fr t i.ci l:tl n l tt' (:o fi nu d t )' P.O Box 280 19 E. N/ain St. Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action December 18, 2008 Permit Number: 08 00554 Project Name: Arctic Circle Remodel Project Type: Commercial Remodel Review ltem Actions Required for Approval Approved l$.....E;ffi*l#$u LLlffi Required Fire Flow Alarm Systems Commercial Cooking Water Supply Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Fire Access Roads Parcel#'s RPRRXBl0l74743 Established. Occupancy is not required to have a fire alarm system according to plans provided. Commercial cooking hood is required to be meet UL 300. Maintain required testing on commercial cooking hoods. Established. All extinguishers are required to be installed before final fire inspection. Total occupancy must remain below 100 or a fire suppression system will be required. N/A Established. a:lTY ot; RAXBURG C\*....... Ameriu! l:anii (.'.onrnu nib P.O Box 280 19 E. lrlain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action December 18,2008 Permit Number: 08 00554 Project Name: Arctic Circle Remodel Project Type: Commercial Remodel Review ltem Actions Reouired for Approval Approvedif}ffi Development Standards Review Development Standards Review Approved Site Plan No streets are indicated on site plan. please revise. ]ree ( see sheet D!.1) may be in right -of -way. Therefore, City approval may be needed to demolish it. Elevation directions appear to be the opposite from what is indicated No North arrow is shown on site plan. please revise. Building extends west and encroaches into theaisle width; width must be 22- feet. Pedestrian walkway to right-of-way will not berequired at this time because limited asphalt isbeing removed, but should parking lot be redone, walkway should be installed. Please specify exterior building material andpaint colors. Approved Site Plan Development Standards Review Approved Site Plan Approved Site Plan Approved Site Plan Development Standards Review 12t02t2008 12t02t2008 12t02t2008 12t02t2008 12t02t2008 12t02t2008 12t02t2008 Please show on revised elevations if there is 12lo2l2oo}any rooftop mechanical equipment. Equipmentmust be screened. Please show where screened trash dumpster 121171200gwill be located and what materials will be used(materials should be high quality and consistent with main building). 121Q2108 - Please show location of screened trash dumpster 12/16108 - Location is existing. However, forbuilding permit purposes to move forurrard,rather than pursue the issue now, it will begiven to code enforcement to follow-up at alater date. Each principal building on a site shall have 12l17l2OOBclearly defined, highly visible customer entrances featuring no less than 3 of the following: canopies or porticos, overhangs, Approved Site Plan T]ITY T}F Rsxsqss A"1t iiai l:afiiil Cotntnusit) P.O Box 280 19 E. lMain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action December 18, 2008 Permit Number: 08 00554 Project Name: Arctic Circle Remodel Project Type: Commercial Remodel Approved recesses/projections, a rcades, ra ised cornicedparapets over the door, peaked roof forms,arches, outdoor patios, architectual detailssuch as tile work and moldings which areintegrated into the building structure and design,integral planters or wing walls that incorporatelandscape areas and/or places for sitting.Please revise or specify. 12102108 - Doors may not be changing, butentrance appears to be modified. Therefore, this standard needs to be incorporated. 12116108 - Entrance projected has architectural Development Standards Review detail with rock and an overhang. windows shall be recessed and should include 12117l2oogvisually prominent sills, shutters, or other suchforms of framing. please revise. 12102108 - This standard stiil needs to beaddressed, but for the new addition only. Flood Plain designation is AE4g66 - please 12l1gl20ogwork with Building Official for constructionrequirements. 121.02108 - No response from applicant _ pleaseaddress. 12118108 - Threshold for flood plain standardswas not exceeded, per Val Christensen, FloodPlain Administrator. Approved Site Plan Parcel#'s RPRRXB1O174743