HomeMy WebLinkAboutREVIEW ACTION - 08-00554 - Artic Circle RemodelclTY ()1l
Rr{*vRc
Am@ i<.a s lilrs i it (1tntn, a itt
P.O Box 280
19 E tr4ain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
December 18, 2008
Permit Number: 08 00554
Project Name: Arctic Circle
Project Type: Commercial
Review ltem
Electrical Service Review
Exiting Review
Height and Area Review
Accessibility Review
Water and Sewer Service
Building Code Fire Compliance Review
Structural Review
Mechanical Review
Energy Conservation Compliance Review
Complies with approved Site plan Review
Plumbing Potable Water Review
Approved
Remodel
Remodel
The electrical plans that were submitted were
very vague, therefore make sure that anything
new is wired to the 2008 NEC and any
questions call Bret at 359-3020x332.
According to the plans that were submitted, no
service change is going to take place-let us
know if it is ASAP.
Meets code requirements.
Meets code requirements.
Provide accessible restrooms as per IBC
Section 3409.7. ldentify on plans.
Male restroom needs grab bars, scald guard on
sink and unisex sign for door.
All plumbing services are required to be tested
and inspected beforei covering.
The materials used to make the "rubber floor"
must meet the requirements of the 2006
International Building Code (tBC) and ASTM E
119.
Have the footings, foundation, shearwalls,
connections etc. been designed by an
engineer? Provide Stamped drawings.
ls mechanical being changed or added to?
The COMcheck Envelope Compliance
Certificate identifies R-10 inslulation at the slab.
The plans do not show this insulation. Also, R-
50 is identified on the certificate and R-38 is
shown on the plans. Please make the
necessary changes.
Allwater lines are required to be installed
11t13t2008
11t13t2008
11t20t2008
11t20t2008
11t25t2008
Electrical Circuits Review
clTY {rtr
RE{*VRG
Amti.r\ llafril, < :ot ntnwlity
P.O Box 280
19 E. lMain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
December 18,2008
Permit Number: 0B 00554
Project Name: Arctic Circle Remodel
Project Type: Commercial Remodel
Review ltem Approved
Plumbing Storm Drain Review
Plumbing Sewer Drain Review
Parcel#'s
according to the Uniform plumbing Code 2003edition.
All strom drains are required to be tested andinspected before covering.
All drains are required to be installed according
to the Uniform Plumbing Code 2003 edition.
RPRRXBIO174743
CITY OII
RSXBT'RG
(\!*.
A fr t i.ci l:tl n l tt' (:o fi nu d t )'
P.O Box 280
19 E. N/ain St.
Rexburg, ldaho 83440
Phone (208) 359-3020
Fax (208) 359-3022Review Action
December 18, 2008
Permit Number: 08 00554
Project Name: Arctic Circle Remodel
Project Type: Commercial Remodel
Review ltem Actions Required for Approval Approved
l$.....E;ffi*l#$u LLlffi
Required Fire Flow
Alarm Systems
Commercial Cooking
Water Supply
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Fire Access Roads
Parcel#'s RPRRXBl0l74743
Established.
Occupancy is not required to have a fire alarm
system according to plans provided.
Commercial cooking hood is required to be
meet UL 300. Maintain required testing on
commercial cooking hoods.
Established.
All extinguishers are required to be installed
before final fire inspection.
Total occupancy must remain below 100 or a
fire suppression system will be required.
N/A
Established.
a:lTY ot;
RAXBURG
C\*.......
Ameriu! l:anii (.'.onrnu nib
P.O Box 280
19 E. lrlain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
December 18,2008
Permit Number: 08 00554
Project Name: Arctic Circle Remodel
Project Type: Commercial Remodel
Review ltem Actions Reouired for Approval Approvedif}ffi
Development Standards Review
Development Standards Review
Approved Site Plan
No streets are indicated on site plan. please
revise.
]ree ( see sheet D!.1) may be in right -of -way.
Therefore, City approval may be needed to
demolish it.
Elevation directions appear to be the opposite
from what is indicated
No North arrow is shown on site plan. please
revise.
Building extends west and encroaches into theaisle width; width must be 22- feet.
Pedestrian walkway to right-of-way will not berequired at this time because limited asphalt isbeing removed, but should parking lot be
redone, walkway should be installed.
Please specify exterior building material andpaint colors.
Approved Site Plan
Development Standards Review
Approved Site Plan
Approved Site Plan
Approved Site Plan
Development Standards Review
12t02t2008
12t02t2008
12t02t2008
12t02t2008
12t02t2008
12t02t2008
12t02t2008
Please show on revised elevations if there is 12lo2l2oo}any rooftop mechanical equipment. Equipmentmust be screened.
Please show where screened trash dumpster 121171200gwill be located and what materials will be used(materials should be high quality and consistent
with main building).
121Q2108 - Please show location of screened
trash dumpster
12/16108 - Location is existing. However, forbuilding permit purposes to move forurrard,rather than pursue the issue now, it will begiven to code enforcement to follow-up at alater date.
Each principal building on a site shall have 12l17l2OOBclearly defined, highly visible customer
entrances featuring no less than 3 of the
following: canopies or porticos, overhangs,
Approved Site Plan
T]ITY T}F
Rsxsqss
A"1t iiai l:afiiil Cotntnusit)
P.O Box 280
19 E. lMain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
December 18, 2008
Permit Number: 08 00554
Project Name: Arctic Circle Remodel
Project Type: Commercial Remodel
Approved
recesses/projections, a rcades, ra ised cornicedparapets over the door, peaked roof forms,arches, outdoor patios, architectual detailssuch as tile work and moldings which areintegrated into the building structure and design,integral planters or wing walls that incorporatelandscape areas and/or places for sitting.Please revise or specify.
12102108 - Doors may not be changing, butentrance appears to be modified. Therefore,
this standard needs to be incorporated.
12116108 - Entrance projected has architectural
Development Standards Review
detail with rock and an overhang.
windows shall be recessed and should include 12117l2oogvisually prominent sills, shutters, or other suchforms of framing. please revise.
12102108 - This standard stiil needs to beaddressed, but for the new addition only.
Flood Plain designation is AE4g66 - please 12l1gl20ogwork with Building Official for constructionrequirements.
121.02108 - No response from applicant _ pleaseaddress.
12118108 - Threshold for flood plain standardswas not exceeded, per Val Christensen, FloodPlain Administrator.
Approved Site Plan
Parcel#'s RPRRXB1O174743