Loading...
HomeMy WebLinkAboutREVIEW ACTION - 07-00405 - Gymnastics Center - Site PlanREXBURG c\, ---^-"- Anrcrica\ Farn ilv Cnmmutri tv P.O Box 280 19 E ltlain St. Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 3s9-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site plan Project Type: Site Plan Review Review ltem Plumbing Review Parking Configuration ldentify handicapped aisle at spaces. Miscellaneous Provide accessibte pedestrian access to thepublic right-of-way without using the driveways. Provide grading plan and drainage details. Parcel #'s RPRAIRCP020060 Approved 11t09t2007 11t09t2007 cllY oIj'REXBURG c\t - ---- Aircr ia\ Farnil)' Commuti ty P.O Box 280 19 E lilain St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site Plan Project Type: Site Plan Review Review ltem Actions Reouired for Aooroval ilffi$iffiiffi il]i]i,tlffi* Additional Comments Parcel#'s RPRAIRCP020060 Approved 11t09t2007 CII-Y OF-REXBURG c\t ----.-'- Anter ica\ Fanily Co mtnuti ly P.O Box 280 19 E Main St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site plan Project Type: Site Plan Review Review ltem Approved Site Plan Approved Site Plan Approved Site Plan Approved Site Plan Approved Site Plan Approved Site Plan Approved Site Plan Approved Site Plan Approved -1 *' One-way driving isle must be clearly marked asone-way. Garbage container location is not shown on thesite plan. This must be fully screened from theright-of-way and may not be located within 20feet of the right-of-way or any pedestrian walkway. Internal pedestrian walkway must connect tothe crosswalk along the right-of-way. One handicap stall must be van accessible. A 6 foot landscape strip is required between thesidewalk and the building facade. The landscape strip shown on the site planrevision dated 101312001averages as at least 6feet wide. Southwest parking stall needs a 6x22 foot backing area. The ordinance does not specifically state theparking requirement for a private gymnastics center. In researching other City's standardsand reading minutes from meetings of othercities, the following requirement was determined: 1 -space per 500 sq. ft. of gross floor area (non_ office area.) 3 spaces per 1000 sq. ft. for areas designatedfor office use. This totals 25 spaces for this project. 2 parking stalls in the Southeast corner of thelot are located in the 10 foot front yard setback. Parking must be visually buffered from the right_of-way with landscaping. Also an 1g foot widelandscaped berm is required along Highway 20.Please submit a detailed lanOscaping plan forreview. 09t14t2007 10t04t2007 't0t04t2007 10t04t2007 10t04t2007 10t04t2007 10t04t2007 10t04t2007 10t05t2007 Approved Site Plan ilExnciic(\' '.-'-*---.. Ameriil\ thni[ (hmmwiry P.O Box 280 19 E tilain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: Project Name: Project Type: Review ltem 07 00405 Gymnastics Center-Site Plan Site Plan Review Actions Reouired for Aooroval A detailed landscaping plan is still needed for review. Landscaping of the 18 foot wide berm along Highway 20 must follow the approved cross section as shown in the Light Industrial design standards. Please submit a lighting plan for review - inluding photometric layout information. Approved Approved Site Plan Parcel #'s RPRAIRCP02OO6O c I'l-Y o f RExgURC c\'t -"'''- An r e r i c a\ f atnily C o mn un i ty P.O Box 280 '19 E lMain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site Plan Project Type: Site Plan Review Access to Hydrants Vicinity Map Provided Fire Lane Signage Existing Hydrants Fire Apparatus Access Required Fire Flow Proposed Hydrants Fire Sprinkler System Required Actions Reouired for Anoroval VIA PUBLIC STREETS VICINITY MAP SHOWS "CEDAR FALLS LOOP", STREET IS ACTUALLY JET STREAM DRIVE. NOT REQUIRED ONE EXISTING HYDRANT SHOWN (APPROXTMATELY 140 FEET TO STRUCTURE), SECOND HYDRANT (NOT sHow) ts APPRoxtMATELY 235 FEET TO STRUCTURE. ACCESS ON EAST SIDE OF BUILDING SHOWS WIDTH TO BE 16 FEET,20 FEET IS THE MINIMUM REQUIREMENT FOR FIRE APPARATUS. CoRRECTED 10t5t07 UNKNOWN FIRE FLOW, UNKOWN TYPE OF CONSTRUCTION, FI RE SUPPRESSION SYSTEM, ETC. UNKNOWN AS OF 10106107 REQUIRED FIRE FLOW FOR 9165 SQUARE FOOT STRUCTURE IS 2OOO SQUARE FEET/TWO HOURS FROM A MINIMUM OF TWO HYDRANTS WITHIN 450 FEET. SQUARE FOOTAGE MAY DICTATE INCREASED FIRE HYDRANTS, PLEASE PROVIDE MORE INFORMATION EXISTING HYDRANTS PROVIDED. PLEASE PROVIDE MORE INFORMATION (SQUARE FOOTAGE, OCCUPANCY LOAD, ETC.) FOR DETERMT NAT|ON. NO ADDITIONAL INFORMATION PROVIDED AS OF 10t06t07 NOT REQUIRED Approved 08t28t2007 08t28t2007 08t28t2007 08t28t2007 10t06t2007 10t09t2007 10t09t2007 't0t09t2007 Review ltem cll'Y 0F a_ _-- -_ REXBURG C\, ----- Am.rtrc's FafiiU Ca mnw i lY P.O Box 280 19 E lvlain St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site Plan Project Type: Site Plan Review Review ltem Approved Site Plan Parcel#'s RPRAIRCPO2OO6O Actions Required for Approval Approved 1. No facilities are show for the management of stormwater. 2. No lighting plans are included. 3. No method is shown for sanitation facilities location. Items addressed. The location for the sanitation dumpster is very difficult to get to. We willwork with them during construction for a better location. cl1'Y or REXB Am er i c s,\ F dil ily Ca m, n u t t i ty P.O Box 280 19 E lrain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00405 Project Name: Gymnastics Center-Site plan Project Type: Site Plan Review Review ltem Actions Required for Aooroval NO HYDRANT FLOWS PROVIDED. NO HYDRANT FLOWS PROVIDED AS OF 10t06t07 Approved Hydrant Flows Provided Parcel #'s RPRAIRCPO2OO6O CITY OF REXBURG c\' '-*-'- *^- An rc r i e\ Filarni ly Cn ilm u t t i ly P.O Box 280 19 E lilain St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00406 Project Name: Gymnastics Center Project Type: Commercial New Review ltem Actions Reouired for Anoroval iffil,ffiiilllliiili Electrical Circuits Review Water and Sewer Service Plumbing Sewer Drain Review Plumbing Storm Drain Review Plumbing Potable Water Review Accessibility Review Building Type Compliance Electrical Energy Lighting Compliance Review Electrical Service Review Exiting Review Height and Area Review Energy Conservation Compliance Review Building Code Fire Compliance Review No electrical plan was submitted, make sure that everything electrical is installed to the 2005 NEC code. N/A All drains are required to be tested and inspected before covering. N/A Allwater lines are required to be tested and inspected before covering. Meets code requirements. Building has been reviewed as Type VB. The occupancy is A-3. No electrical plan was submitted, need to see a power riser diagram. The service is going to be a2O0 ampere service, make sure that this is wired to the 2005 NEG. Maximum occupancy # must be posted. ldentify exit signs and emergency lighting. Panic hardware is required on the doors of A occupancies with an occupant load greater than 100. Provide stairdetails. ldentify gaurdrails at mezzanine. As per IBC Table 503, building requires a sprinkler system in order to be a two story structure. Also as per Table 503, the area of the building is required to be a maximum of 10500 sq. ft. Provide energy review for mechanical, electrical and envelope. Provide fire-blocking detail at mezzanine. Approved 09t05t2007 09t07t2007 09t07t2007 09t07t2007 09t07t2007 ogt14t2007 09t14t2007 10t22t2007 11t08t2007 11t09t2007 11t09t2007 11t09t2007 11t09t2007 CITY OF REXBURG Ameriu\ Farnily Co mmuni tv P.O Box 280 19 E Main St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-s022Review Action November 9,2007 Permit Number: 07 00406 Project Name: Gymnastics Center Project Type: Commercial New Review ltem Mechanical Review Structural Review Waste Water Application Waste Water Grease Trap Form Miscellaneous Parcel #'s RPRAIRCPO2OO6O Provide mechanical details and sizing. Provide structural documents for wood building,foundation of the wood building and themezzanine. The steel building plans do notidentify another structure or a mezzanine beingattached. The steel building plans identity a - 31.5 lb/sq.ft. snow load. The minimum snowload for the City of Rexburg is 35 tb./sq. ft.Special inspections are required for structuralfill, concrete foundation, high strength boltingand any welding. please provide the name ofthe firm that will be performing the specialinspections. Provide truss details for the woodtrusses prior to frame inspection. All footingsmust be 36" below grade for frost. Approved 11t09t2007 11t09t2007 ldentify masonry flashing and waterproof barrieron plans. CITY Of REXBURG c\'' - _- --' Ameriu\ Ihnily Commwi ty P.O Box 280 19 E lilain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00406 Project Name: Gymnastics Project Type: Commercial Center New Review ltem Approved Required Fire Flow See site ptan Review OglOTl2OOT Water Supply See site plan Review OglOTl2OOT Fire Access Roads See site plan Review ogtOTl2OoT Fire Extinguishers Fire extinguishers are to be instalted prior to ogtoTt2oolfinalfire inspection.Automatic Fire Extinguishing systems Not required for this occupancy according to ogloTl2ooTplans provided. standpipes N/A ogrcTnooT commercialcooking N/A ogrcTnoo1 Alarm systems Not required according to plans provided. oglo?t2ooT Parcel #'s RPRAIRCP020060 hEXBuRG c\' *_"'-- --- Anteriu\ Fhmib' Commwi ty P.O Box 280 19 E lilain St. Rexburg, Haho 83440 Fhone (208) 3S9-3020 Fax (208) 359-3022Review Action November 9,2007 Permit Number: 07 00406 Project Name: Gymnastics Center Project Type: Commercial New Development Standards Review Parcel #'s RPRAIRCPO2OO6O As part of the transitional design standards forthe Highway 20 corridor, a minimum 1g footwide landscaped berm is required between therear elevation and the right-of-way for Highway20. Landscaping must follow the cross sectionshown in the Light lndustrialdesign standards. The office area on the front elevation of thebuilding must incorporate one repeating element of color, texture, or material modulechange every 30 feet horizontally. Thisrequirement is met vertically, but nothorizontally. Approved 't0t18t2007 11t01t2007 Review ltem Development Standards Review