Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site Plan
Project Type: Site Plan Review
Review ltem Approved
ef$ding Departmeiit:Review
Fire Separation
Parcel#'s RPR000K0012930
Actions Required for Approval
The buildings on the lot line will need to be
constructed for fire seperations as per the 2003
International Building Code (lBC).
X ltghh{rkJ
6vbrnrjJd
;Ju{,s 610 rqWd ft brtU
6t,&rw.lfuC gyrT fr igs&nb of flv;
0entficder'c? ^wvw*
CITY OF
REXBURG
c\' ---- ..
Arneica! lhilti bt Co mmun i ty
P.O Box 280
19 E il4ain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number:
Project Name:
Project Type:
Review ltem
07 00502
Ryan Orme Storage Units-Site Plan
Site Plan Review
Actions Required for Approval Approved
fire rRs^ri$,)
Fire Apparatus Access
Vicinity Map Provided
Access to Hydrants
Fire Sprinkler System Required
Fire Lane Signage
Existing Hydrants
Proposed Hydrants
Required Fire Flow
Hydrant Flows Provided
Parcel#'s RPR000K0012930
PROVIDED
PROVIDED
ACCESS VIA PUBLIC ROAD
NOT REQUIRED
NOT REQUIRED
EXISTING HYDRANTS NOT SHOWN
EXISTING HYDRANTS SHOWN ON 10/30/07
PLAN
NO PROPOSED HYDRANTS SHOWN
1OI3OIO7 PLAN SHOWS TWO NEW
HYDRANTS LOCATED ON PROPERTY
REQUIRED FIRE FLOW NOT PROVIDED.
ESTIMATED FIRE FLOW REQUIREMENTS
BASED ON 48OO SQUARE FEET, TYPE V-B
CONSTRUCTION, S OCCUPANCY IS 1750
GPM/TWO HOURS FROM A MINIMUM OF
TWO HYDRANTS WITHIN 5OO FEET.
ffi Hffi k#{r.fiolry#IwsRow@f tr
fr*ffiw'PRCI\rfi)g FrsrrvsfotsgxrsTrNG-AND PROPUSED HYTTRANTSI
10t06t2007
10t06t2007
10t06t2007
't0t0612007
10t06t2007
10t30t2007
't0t30t2007
10t30t2007
cllY oF
ITEXBURG
c\' --
/\n eri ce! Fami ly Co nmrfr ity
P.O Box 280
19 E t\rbin St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site Plan
Project Type: Site Plan Review
Review ltem Actions Re+uired for Approval Approved
Fire,,gg0,eftmiit Review,, .
Additional Comments
Parcel#'s RPR000K0012930
( t'rY oh/.-a---v.-\'/--rs;ilrs=\t\
$m? IdEXB.*URG
\",'<tJ7/) t\ar I
\ / A,nerica\ l-anib' CannunitY
P.O Box 280
19 E [4ain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site plan
Project Type: Site Plan Review
Review ltem Actions Required for Approval Approved
ptaiiiil&$Fff Reiiloirlv, "r"'
Approved Site Plan
Approved Site Plan
Approved Site Plan 10131t2007
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
Site plan is not to scale. Please revise.
A condition of the conditional use permit as
approved by the P&Z Commission is that there
be at least 50 feet from the back of the sidewalk
to the entrance gate to allow for safe parking of
vehicles with trailers. Required fence is not
shown. Please revise.
One parking space per every 200 units, plus
one parking space per employee is required.
No parking spaces are shown. Parking must
be fully screened from the right of way with
landscaping.
Since there are less than 200 units proposed,
no parking is required.
Any one-way driving isle must be clearly
marked as one-way.
One handicap parking space must be van
accessible.
Parking spaces are not required.
Please show sidewalks along right-of-way with
ADA accessible ramps.
A decorative masonry wall, at least 6 feet in
height, is required along all property lines which
lie adjacent to a residential zone. Please
revise.
Please indicate the number of proposed
storage units on the plans.
The property should only be provided with one
entrance from 4th South. Please revise.
Please submit elevations for design standards
review.
All areas for snow storage, and all areas not 1112112007
designated for parking or manuevering, must be
landscaped. Please submit a detailed
10t31t2007
1013112007
10t31t2007
10t31t2007
10t31t2007
10t31t2007
10t31t2007
10t31t2007
10t31t2007
CIT'Y OF
REXBURG
c\t
Aft e ricd! I1aft i Il Co mn un ity
P.O Box 280
19 E lUain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27 ,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site plan
Project Type: Site Plan Review
Review ltem Actions Required for Approval Approved
landscaping plan for review.
A landscaping plan with details (tree, shrub andground cover types, planting sizes) is still
required for review. Please note the
landscaping requirement for the front yard
setback as a condition of the conditional usepermit.
Grass is recommended instead of tulips for
maintenance purposes.
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
The fence required as part of the conditional
use permit is not shown. please revise.
Required fence is not allowed within the 20 foot
front yard setback from the property line.
Please revise.
Trash receptacle must be fully screened from
11t21t2007
11t21t2007
the right-of-way and cannot be located within 20
feet of the right-of-way. Please revise.
Please provide screening detail for the garbage
container.
The 20 foot front yard setback from the propety 1jl2jl2o|7
line must be appropriately landscaped. please
submit a landscaping plan for the entire
property for review.
Landscaping plan must provide details of plant
type and size.
To provide adaquate screening of the proposed 11t2112007
buildings and use, decorative opaque fencing
shall be included along the front of the proposed
buildings and parking area, but not within the
front yard setback. ln addition, landscaping
shall be established within the front yard
setback shall include the follwoing as a
-Fully automated sprinkler system - details tobe approved by they city engineer.-Evergreen trees - one tree per 20 feet of lot
frontage, 7-feettall at planting. Drought tolerant
CITY OF
REXBURG
c\,
An e i ca'.s l:-ami Iy C o n m uni ty
P.O Box 280
19 E tuain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site plan
Project Type: Site Plan Review
Review ltem Approved
and native trees should be considered.-Shrubs - one shrub per 5 feet of lont frontage,
five-gallon containers at planting. Drought
tolerant and native shrubs should be
considered.
-Ground cover shall include a majority of grass.
Drought loterant species such as buffalo grass
or similar should be considered.
Fence cannot be within the 20 foot front yard
setback. The landscaping requirement is notmet (number of trees and shrubs). please
provide this landcaping in the front yard
setback.
All conditions placed on the conditional usepermit for the site shall be adhered to.
A site plan with a diagram depicting
maneuvering for vehicles the size of the City's
large emergancy vehicles is required. These
vehicles should be depicted at the corner ofproposed buildings.
City fire trucks are about 35 feet long. Vehicle
shown on the maneuvering diagram is the sizeof a personal pickup truck. please revise.
Chris approved the diagram submitted
11t21t2007
Manuevering area at the site entrance does not
look feasible. Please provide a maneuvering
diagram with complete turning radii at each
corner of the development for a large vehicle
with a towing trailer. Vehicles with trailers willlikely be accessing the site regularly.
f&*****U Ftust conform..to the eornnrercial
W?firlgs*andards..pffifggUbmit a, detailltf
fiftfrttg plan; including.pffimetric fayout'dlta,
ftlt revlew.
BtgASe provide fence detaits for revierr. .
Approved Site Plan
Approved Site Plan
Approved Site Plan
Approved Site Plan
1',v21t2007
11t26t2007
11t26t2007
'\ la.r lol
Approved Site Plan t'lar I or
RE_xBJKg
Aft eri ca\ I'arhib, Co n fr u n i ty
P.O Box 280
19 E fvhin St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site plan
Project Type: Site Plan Review
Review ltem Approved
Parcel#'s RPR000K0012930
.,Aa/.-(Ig-'l*"1|'f4M1F' I\"rD4Rtt- /\""zrtt\vt
\,;,2
clTY ot-
REXB^lgq
A tne rica:s lrdt h ily Co m ntufr i ty
P.O Box 280
19 E [4ain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00502
Project Name: Ryan Orme Storage Units-Site plan
Project Type: Site Plan Review
Review ltem Actions Reouired for Aoproval
Publfeulbrls:ftview 3 ,,,;l' lr, ;, . f
Approved Site Plan
Approved
1. The project appears to cover the entire site.
No area is shown for landscaping, snow
storage, etc.
2. The enterance cannot be constructed as
shown. The curbing along 4th south must
remain at the existing location and a curb cutprovided.
3. No sidewalk is shown along 4th south
4. No lighting plan is provided.
5. Only one driveway will be allowed onto 4th
south.
6. The sanitation dumpster cannon be located
on city right-of-way.
7. There is a call out for a new water line andfire hydrant but are shown to be in the driveway.
Items addressed except for the driveway into
the site. The use of curb returns will not beallowed. A curb cut and approach is required.
I need to visit with Chris H. on the location of firehydrants.
Parcel #'s RPR000K0012930
Review Action
P.O Box 280
19 E lVtain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022
November 27, 20OT
Permit Number: 07 00503
Project Name: Ryan Orme Storage Units
Proiect Type: Commercial New
Parcel#'s RPR000K0012930
cItY Ot:
REXBURG...N.-""___
A rrrc rica! lani ly Co mm un ity
P.O Box 280
19 E lilain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-9022Review Action
November 27,2007
Permit Number: 07 00503
Project Name: Ryan Orme
Project Type: Commercial
Storage Units
New
ApprovedEu|idingr:Dopeiinio'rl Review ,: , ,, ., .
Electricalservice Review No plan was submitted. Need at least a power 'lotogl2oo1
riser diagram for the service. Approved toproceed.
Electrical Energy Lighting Compliance Review
Height and Area Review
Building Type Compliance
Plumbing Storm Drain Review
Structural Review
Accessibility Review
Building Code Fire Gompliance Review
Waste Water Application
Waste Water Grease Trap Form
Parcel #'s RPR000K0012930
No lighting plan was submitted for energy iorogr2ooTcompliance, one is not needed for this type otbuilding.
Meets code requirements.
Buildings have been reviewed as Type VB witha S-1 occupancy.
10t10t2007
Provide structural calculations. lOlgll2OOT
Provide accessible storage units as per rBC llrogr2oo1Section 1108.3
Provide 2hour fire rated wails as per Tabre 602 11rogt2oo7of the 2003 Internationat Buitding 'Code (tBC).P{rovide details.
10t10t2007
10t10t2007
CITY OI]
URG- --- -clv
A hrri c d\ l:afl i ly Co fi m un ity
P.O Box 280
19 E lilain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00503
Project Name: Ryan Orme Storage Units
Project Type: Commercial New
Review ltem
fird,Scn{ftircntR6vl6vlil, -, -,,1
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systems
Parcel#'s RPR000K0012930
See site plan review.
See site plan review.
See site plan review.
Fire extinguishers are required for this
occupancy. Install according to the International
Fire Code 2003 edition.
Not required according to plans provided.
N/A
N/A
Not required according to plans provided.
Approved
't0t10t2007
10t10t2007
10t10t2007
10t10t2007
10t10t2007
10t10t2007
10t10t2007
10t10t2007
CITY OF
URG
clv
A trc i cai l1afri Il (:o mm utl ity
P.O Box 280
19 E lilain St.
Rexburg, Haho 83440
Fhone (208) 359-3020
Fax (208) 359-3022Review Action
November 27,2007
Permit Number: 07 00503
Project Name: Ryan Orme Storage Units
Project Type: Commercial New
Plannlng Staff Revlsw
Development Standards Review
Development Standards Review
Development Standards Review
Parcel #'s RPR000K0012930
Elevation drawing of the South building facadesis approved as submitted 1Ot11t2OOT.
Architectural panels are required along thebuilding facade on the east property liie. Thismust extend at least past the car dealershipproperty, and must not change to other materialin the middle of a neighbor's property line.
Required fence and landscape along 4th Southmust be incorporated in the plans. please
submit this for review. See detailed
requirments in the CUp conditions.
Approved
10t17t2007
't1t21t2007
11t21t2007
6: 4SPM
NANGIA
R-1 ITIINDSHIELD, INC.( 208 ) 356 -7846
2n1-A5}1g84 p.z
P.1
Chandcr P. Nangia pc74ti I Iollow Ridgc Dr ptrizs: ) Esg- t42lI {or.rstorr, 1. X ZZ0t5 t;rx:-(2 t i1 tSl- t e*cErn:ril: naqri aeng@s bcgloba l.ncr
Dcccnlbcr I E. ?007 07 00503
Ryan Orme Storage Units
322 W 4th s
Rcxburg Srorugc I.I.C
Rcxburg. lD
,lob #: Xl.lvl-O7l I / tr39.Ss
'l'o Whorn lt May Conccrn:
Wc havc rcvic\acd thc {irunrLariorr p!elrs lbr tht irbover rcl.crencrd projr*t. Bgsecl orr (}nrrsvisw, the fbllou,inq clranges rt al: bc made:
I ) 'l'hc (-irad,r" bcorns on tbis job rnay be rcviscd to 2 - fl.I bors (c.onl) t'or rhchorieontll ruintbrcing per tlrc uttachcd dctail. Adclitiorroily. ,tro., -ir,. ti.n*tdcplh does not nccd to bc tncl for this lypc ol srructurc lls yornc movcnrcnt inrhe slab rvill rrot :rflfoct tlrc s11q6111yat iniilgrity ot thc huilding^s,
It'yt'ru hitve ilnv ftlrther clucstipn5, gon)menlN. or con!:crns orr lirc obovc rc-fr,'rg.nccd projcctplcnsc llr:l l'rcc lo corlr{rct nrc.
DEC 1 I 20|,7
EEXBUnG
Dec
)ec '18 -07
19 2(JrJ'7
ffi34p
6: 4SPM
NANqA
R-1 IJINDSHIELD, INC.(208) 356-7846
2$-e5*1Aa/
REFEF rO 3UILDINC
FTANS FOR NOTCH
s/zE ANO LoCAT|oNS,
t+ o tB" o.c, c.w. oR13 o 15'O,c E.w.
cRAN'.ILAR FILL
2 - ,+ coNT.
PERIMTTER GRADEEEAM
SECTION 1 - 1
CHAN DtR P, NANGIA PT
742i HOLLCW RtDGt DR.IfOUSTON, rX 7709s
p.2
p3
TXCEL MTIAL BUILDINS SYSTTIvIS
3J3O EDC*:.f/OOD - BAXIER SPRINGS, .<S 667iJ
DESCRIP]ION FOUNDAIION PTAN & DETAILS
sffi5.-rsnFjp!J!_ i._J
... _ RExE_uRosToR4GE,rLc
loDA;roN REXBURGJD
Deslgn
_ Ifrtelligence, LLC
Structural E ngineering
1037 Erikson Drive
R*barg, Idaho 83440
Date: March 13,2006
To: Val Christensen
Cify of Rexburg Building Department
Subject: Pinnacle Security Comments
Dear Sir:
Call: (208) 359-1461
FAX: (208) 3s9-0740
llEcEruEfr
ll MAR I 3 2006 ll/
1. Total Occupant number for upstairs is greater
than99 therefore stairs must be 44,, wide ...
The square footage of the business/remodeled
spaced is 5843 sf. All other areas are auxiliaryto
the business and in fact will be used little if at all.
The occupant load based on this is 59. Using this
occupant load the factor for stairs from Table
1005.1 of 0.3 the minimum width of the stairs is
17.7 inches or the minimum of 36', which is
available. The stairs are not an.,accessible,'means
2. Provide details that identifyhow the
requirements of IBC Section 704.11(parapet
construction) will be met.
Parapets are not required as the entire building is
more than 10 feet from anyproperty line or traveled
way. The North side of the building is protected by
alegal easement from the adjacent owner that is
3. Two hour fire doors on plans must be self
4. Dead end h4lways cannot exceed 20 feet See revised drawings of Main and Second Floors5. Are footings required for new bearine walls?
6. How is HVAC being handled?No changes to existing HVAC are plarured. Each
office will be heated with electric baseboard type
heaters.
7. Fire Extinguishers See revised floor plans for location of ZAIOBC fire
8. Please provide details on Kitchen Area The "Kitchen Area" on the drawings is a break area
and is now labeled as such. The only cooking
appliances provided will be a microwave.
9. Manual Fire alarm system required .Independent Alarm design companyhas been
contracted to oreoare reouired docrrme.nts10. Swimming Pool details Data on the pool operations and chemicals will be
provided by the owner.
Please call if you have any further questions.
Scott A Spaulding,
Design Intelligenc
44SS
%'oo'o$
' besign ihteiligence, LLC
135 East Main, Suite A
ldaho 83440
PINNACLE SECUIRI
REXBURG, I 3t13t2006