HomeMy WebLinkAboutSTAFF REVIEWS - 06-00585 - Super 8 Motel - AdditionCITY OF REXBURG-'.-.- -c\, A ne r i c d',s Fd nli b' Co fr ttt wt i ry 19 E ltr'lain St. Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super I Motel Addition Commercial Addition Actions Reouired for Aooroval Approved Permit Tech Notes Mechanical contractor information, signature, & estimate needed. Parcel#'s RPRRXB10410031 ctTY of REXBURG c\v -..-..- .. Aft rc licai f a mi Iv Cotim toti ly 19 E Main St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem Actions Required for Approval Approvedg ,:il , Water and Sewer Service Plumbing Sewer Drain Review Plumbing Storm Drain Review Plumbing Potable Water Review Complies with approved Site Plan Review Building Type Compliance Accessibility Review Exiting Review All plumbing services are required to be tested and inspected before covering. New srevices are required if existing services are large enough to support fixtures in the new addition. Alldrain lines are required to be installed according to the Uniform Plumbing Code 2003 edition. All drains are required to be tested and inspected before covering. All roof drains are required to be tested and inspected before covering. Allwater lines are required to be installed according to the uniform plumbing code. All water lines are required to be sized according to the current codes. Water lines must be large enough to support existing and new addition. lf the water lines are not large enough new water service may be required. A site plan has been reviewed. Building is type VB. Are accessible units meeting the requirements of IBC Section 1107.6 provided? Occupany amount (under 50) must be posted in swimming area as per IBC Section 1004.3. The upstairs occupancy is 12 as drawn (two double beds in 3 rooms equates to 12). Maximum occupancy from the second floor is 10 unless two exit accesses are provided. Either change one room to a single bed unit or provide two means of egress from the hall asper f BC Sections 1014.1,1014.2 and 1016.3. Provide exit signs and emergency lighting. ldentify on plans. Space under stairs must be one hour rated construction. Provide water resistive barrier on exterior walls 12t22t2006 12t22t2006 12t22t2006 12t22t2006 01t02t2007 01t02t2007 02t15t2007 02t15t2007 _ Miscellaneous 03t13t2007 CITY Ot- REXBURG-- cs/ -- -'- Anetics'-r flmil\, (:onnw nily 19 E lVlain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem Actions Required for Approval Approved Height and Area Review Mechanical Review Structural Review Building Code Fire Compliance Review Energy Conservation Compliance Review Electrical Service Review as per f BC Section 1403.2. Double underlayment and ice membrane required as per IBC Section 1507. ldentify all of the above on the plans. Meets height and area requirements. Provide venting in laundry and bathrooms as per the 2003 lnternational Mechanical Code. Provide HVAC sizing and drawings. ldentify court (patio and "closed" area) drainage as per IBC Section 1206.3.3. The live loads identified for the upper floor on the structural calcs are for 40 1b/sq.ft.. The corridor is required to be calculated at 100 1b/sq.ft. as per IBC Table 1607.1. Special inspections are required for the foundation. Please provide a letter from the Special Inspection Firm that identifies frequency and type of inspection to be performed. Provide truss details prior to frame inspections. The building must be fire sprinklered as per IBC Section 903.2.7. The north wall must be one hour rated as per IBC Table 602. In order to establish the allowed amount of openings in the north wall, an imaginary property line must be established. The amount of windows in the existing building will determine how where the line can be drawn. The results from both sides of the line must meet the requirements of IBC Table 704.8. Roof construction must meet the requirements of IBC Section 704.11. Provide electrical energy review. Need to delete the Receptacles in the Pool and Spa areas due to clearances that are to close to the inside walls of the Pool/Spa (NEC 2005 section 680-22a). No lighting schedule was submitted, need lights above the Pool/Spa to be 03t13t2007 o3l'1312007 03t13t2007 03t13t2007 03t13t2007 03t1512007 CITY OI' REXBURG cls, .-'*-- Attetic o\ | e nrit' Cot Dti uil i ly 19 E lvlain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem Parcel#'s RPRRXBl04l003l Actions Reouired for Approval totally enclosed, (NEC 2005 section 680-22b2). Also need to see where the power is that will supply this addition. Approved CITY OIJ REXBURG- -- ---- cls, America\ Ltmi lt, Comnu ni Iv 19 E Main St. Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super I Motel Addition Commercial Addition Actions Required for Approval Approved Fn$effiffi$ffiffi$f '"'" Required Fire Flow Other Comments Alarm Systems Commercial Cooking Standpipes Automatic Fire Extinguishing Systems Fire Extinguishers Water Supply Fire Access Roads Parcel#'s RPRRXBt041003l See stie plan review Lock box is required for this occupancy. Forms are available at the Rexburg Fire Department. Fire alarm system is required for this occupancy. Please submit letter of intent for certified fire alarm contractor. Alarm system is required to be approved before installation. N/A N/A Fire sprinkler system is required for this occupancy. Please submit letter of intent for certified fire alarm contractor. Fire extinguishers are required for this occupancy. Minimum of 2A1OBC extinguishers are required. Extinguishers are required to be installed before final fire inspection. See stie plan review See site plan review 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 CITY OF REXB,*\8G ,Ameticai Fefttill Coflntnlily 19 E Main St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super 8 Motel Addition Commercial Addition 16(ffi''''':"irg,* Development Standards Review Development Standards Review Development Standards Review Development Standards Review Development Standards Review Actions Required for Approval Approved Facade colors shall be low reflectance, subtle, 0311512007 neutral, or earth tone colors. Sidewalks along building facade must be 0311512007 located at least six (6) feet from the facade to provide planting beds for foundation landscaping, except where features such as arcades or entryways are part of the facade. Landscape strip averages 6-feet in width along perimeter of facade. Parking in the front must be screened with 0410512007 improved to current landscape strip. This can include tree and shrub plantings and/or 3-4 foot high earthen berm. Recommendation: 1 tree per 20lineal feet and 1 shrub per 5 lineal feet. Clustering is encouraged. This requirement is not shown on revised site/lanscape plan. Waived in lieu of increased shrub planting along sidewalk. 5 shrubs per 20 lineal feet (8 shrubs total) recommended. Shrubs shall be planted in 5 gallon containers. Please indicate the location of screened 0410512007 garbage containers This requirement is not shown on revised site plan. Please address this on revised site plan. Future location of garbage container cannot be within 20 feet of any public thoroughfare of street, sidewalk, or intenal pedestrian walkway. Site shoufd include a centralfeature and 0410512007 community space- See Page 167 of the Ordinance 926. Examples: patio/seating area, pedestrian plaza with benches, outdoor play area, water feature, etc. Depicted picnic tables are located in an interior area and therefore should not be counted towards satisfying this requirement. lt is CITY OIT REXBURG c\' --- America\ F'anily Cornmurily 19 E lilain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem Parcel#'s RPRRXBlO4lOO31 Actions Required for Approval recomended that this amenity should be located closer to Main Street. A quality bench could be located and maintained in the lansdcape strip behind the sidewalk on Main Street (recommendation only). Approved CITY OF REXBURG-...- - c\J --* Au erica\ F ani ly Con mwi ly 19 E lvlain st. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super 8 Motel Addition Commercial Addition -xi Actions Required for Approval Approved Mechanical contractor information, signature, & estimate needed. Parcel#'s RPRRXBT04lOO3l Permit Tech Notes CITY OI: REXBURG---'*.c|g, Am eri ca's t omi lv Communi lv 19 E lvlain St. Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super 8 Motel Addition Commercial Addition Actions Reouired for Annroval Water and Sewer Service Plumbing Sewer Drain Review Plumbing Storm Drain Review Plumbing Potable Water Review Complies with approved Site Plan Review Building Type Compliance Accessibility Review Exiting Review All plumbing services are required to be tested and inspected before covering. New srevices are required if existing services are large enough to support fixtures in the new addition. All drain lines are required to be installed according to the Uniform Plumbing Code 2003 edition. Alldrains are required to be tested and inspected before covering. All roof drains are required to be tested and inspected before covering. Allwater lines are required to be installed according to the uniform plumbing code. All water lines are required to be sized according to the current codes. Water lines must be large enough to support existing and new addition. lf the water lines are not large enough new water service may be required. A site plan has been reviewed. Building is type VB. Are accessible units meeting the requirements of f BC Section 1107.6 provided? Occupany amount (under 50) must be posted in swimming area as per IBC Section 1004.3. The upstairs occupancy is 12 as drawn (two double beds in 3 rooms equates to 12). Maximum occupancy from the second floor is 10 unless two exit accesses are provided. Either change one room to a single bed unit or provide two means of egress from the hall as per fBC Sections 1014.1,1014.2 and 1016.3. Provide exit signs and emergency lighting. ldentify on plans. Space under stairs must be one hour rated construction. Provide water resistive barrier on exterior walls Approved 12t22t2006 12t22t2006 12t22t2006 12t22t2006 01t02t2007 01t02t2007 02115t2007 02115t2007 Miscellaneous 03t13t2007 CITY OT REXBURG.,---- ... - C\, *---- Ameriu',; Familv Communilv 19 E lvtain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem Actions Reouired for Aonroval Approved Height and Area Review Mechanical Review Structural Review Building Code Fire Compliance Review Energy Conservation Compliance Review Electrical Service Review as per IBC Section 1403.2. Double underlayment and ice membrane required as per IBC Section 1507. ldentify all of the above on the plans. Meets height and area requirements. Provide venting in laundry and bathrooms as per the 2003 International Mechanical Code. Provide HVAC sizing and drawings. ldentify court (patio and "closed" area) drainage as per IBC Section 1206.3.3. The live loads identified for the upper floor on the structural calcs are for 40 1blsq.ft.. The corridor is required to be calculated at 100 1blsq.ft. as per IBC Table 1607.1. Special inspections are required for the foundation. Please provide a letter from the Special Inspection Firm that identifies frequency and type of inspection to be performed. Provide truss details prior to frame inspections. The building must be fire sprinklered as per IBC Section 903.2.7. The north wall must be one hour rated as per IBC Table 602. In order to establish the allowed amount of openings in the north wall, an imaginary property line must be established. The amount of windows in the existing building will determine how where the line can be drawn. The results from both sides of the line must meet the requirements of IBC Table 704.8. Roof construction must meet the requirements of IBC Section 704.11. Provide electrical energy review. Need to delete the Receptacles in the Pool and Spa areas due to clearances that are to close to the inside walls of the Pool/Spa (NEC 2005 section 680-22a). No lighting schedule was submitted, need lights above the Pool/Spa to be 03t13t2007 03t13t2007 03t13t2007 03t13t2007 03t13t2007 03t15t2007 CiTY OF MXBURG-*----- ---- (\J Ane i c a's tdmil)' Com nutli rl 19 E lvlain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: Project Name: Project Type: Review ltem 06 00585 Super 8 Motel Addition Commercial Addition Actions Required for Aoproval totalfy enclosed, (NEC 2005 section 680-22b2). Also need to see where the power is that will supply this addition. Approved Parcel#'s RPRRXB10410031 CITY O}- REXBURG csJ ---.- America'-s Family Communily 19 E fr4ain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Commercial Addition Review ltem &d Other Comments Alarm Systems Commercial Cooking Standpipes Automatic Fire Extinguishing Systems Fire Extinguishers Water Supply Fire Access Roads Parcel#'s RPRRXBIO4IOO3I Actions Required for Approval Approved See stie plan review Lock box is required for this occupancy. Forms are available at the Rexburg Fire Department. Fire alarm system is required for this occupancy. Please submit letter of intent for certified fire alarm contractor. Alarm system is required to be approved before installation. N/A N/A Fire sprinkler system is required for this occupancy. Please submit letter of intent for certified fire alarm contractor. Fire extinguishers are required for this occupancy. Minimum of 2A1OBC extinguishers are required. Extinguishers are required to be installed before final fire inspection. See stie plan review See site plan review 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 12t22t2006 Required Fire Flow CITY OF URG(\'----. -- - Am eric a's l;dnil U Co n mu ility 19 E lMain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super 8 Motel Addition Project Type: Review ltem Commercial Addition w',,i'.&t,{&,x Development Standards Review Development Standards Review Development Standards Review Development Standards Review Development Standards Review Actions Required for Approval Approved Facade colors shall be low reflectance, subfle, 03115t2007 neutral, or earth tone colors. Sidewalks along building facade must be }gliSt2}OT located at least six (6) feet from the facade toprovide planting beds for foundation landscaping, except where features such as arcades or entryways are part of the facade. Landscape strip averages 6-feet in width along perimeter of facade. Parking in the front must be screened with 04t05t2007 improved to current landscape strip. This caninclude tree and shrub plantings and/or 3-4 foot high earthen berm. Recommendation: 1 treeper 2O lineal feet and 1 shrub per 5 lineal feet. Clustering is encouraged. This requirement is not shown on revised site/lanscape plan. Waived in lieu of increased shrub planting along sidewalk. 5 shrubs per 20lineal feet (8 shrubs total) recommended. Shrubs shall be planted in 5 gallon containers. Please indicate the location of screened 04tOSl2OO7 garbage containers. This requirement is not shown on revised siteplan. Please address this on revised site plan. Future location of garbage container cannot be within 20 feet of any public thoroughfare of street, sidewalk, or intenal pedestrian walkway. Site should include a centralfeature and 04t0Sl2OO7 community space- See Page 167 of the Ordinance 926. Examples: patio/seating area, pedestrian plaza with benches, outdoor play area, water feature, etc. Depicted picnic tables are located in an interior area and therefore should not be counted towards satisfying this requirement. lt is 8.EXB*,I4G Ame ri cai lemily Cornil! nily 19 E Main St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action October 8,2007 Permit Number: 06 00585 Project Name: Super g Motel Addition Project Type: Commercial Addition Aoproved recomended that this amenity should belocated closer to Main Street. A quality benchcould be located and maintained in thelansdcape strip behind the sidewalk on MainStreet (recommendation only). Parcel#'s RPRRXBl0410031