Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 05-00001 - Just Sports - AdditionCITY OF ,REXBURC ANlLRK:A'-S t Ai,ltLY COrU\,1UNl IY Review Action P.O Box 280 19 E lr4ain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022 January 18,2005 Permit Number: 05 00001 Project Name: Just Sports Addition Project Type: Commercial Addition Feyte.ullem Aq-tlons BequireLfqrApprqvalBuifding Department Review Complies with approved Site plan Review Site plan has been redlined. Exiting Review Meets the requirements of the ordinance. Building code Fire compliance Review rhe east wall of the new addition is at 10,fromproperty line. Any projection (eaves) thatextends past this 10, line will have to be Accessibility Review Structural Review Height and Area Review Building Type Comptiance Mechanical Review Miscellaneous Parcel #'s RPRRXBPOO2OO2O constructed as t hr. rated. Meets requirements of the lBC. Openings in bearing walls over 4,wide require aminimum of double trimmers. plans have beenredlined to identify descrepancies. provide truss details prior to frame inspection. Meets requirements of lBC. Building is Type VB. As per developer, the warehouse space will notbe conditioned. lt will require no mechanicalorenergy review. Double trimmers are required under each sideof any header for an opening over 4, wlOe 1asper building code). plans have been redlined. Appllored 01/06/2005 01/06/2005 01/06/2005 01/06/200s 01/06/2005 01/06/2005 01/06/2005 01/06/2005 01/18/2005 CITY O[ Review Action P.O Box 280 19 E. lrlain St. Rexburg, Haho 83440 Fhone (208) 3S9-3020 Fax (208) 359-3022 January 1B,20Os Permit Number: 0S 00001 Project Name: Just Sports Addition Project Type: Commercial Addition Review ltem Fire llepartment Review Fire Access Roads Fire Extinguishers Standpipes Commercial Cooking Other Comments Alarm Systems Water Supply Automatic Fire Extinguishing Systems Required Fire Flow Parcel#'s RPRRXBPOO2OO2O -_ Aotlanq Aequireltorapproraf ESTABLISHED. PLANS DO NOT SHOW FIREEXTINGUISHERS.... PRIOR TO OCCUPANCYPERMIT MINIMUM SIZE OF 2A1OBC FIREEXTINGUISHERS MUST BE MOUNTEDWITHIN TRAVEL DISTANCES. NOT REQUIRED. NONE SHOWN. ALTHOUGH NOT REQUIRED A LOCK BOX 1SSTRONGLY RECOMMENDED. NOT REQUIRED. FIRE FLOW REQUIREMENTS OF 2250GPM/TWO HOURS REQUIRED rNOU rWOHYDRANTS WITHIN 450 FEET OF 72OOSQUARE FOOT STRUCTURE...APPROVED. NOT REQUIRED UNLESS STORAGECOMMODITY EXCEEDS CITY Or NEXEUNEADOPTED IFC 2003. CONTACTED DESIGNINTELLIGENCE FOR CLARIFICAiIOT,WAITING FOR RESPONSE. -APprqvc.d 01/06/2005 01/06t2005 01/06/2005 01/06/2005 01t06/2005 01/06/2005 10/06/2005