HomeMy WebLinkAboutREVIEW ACTIONS - 04-00419 - Subway - New BuildingI P.O Box 280 19 E. Main St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022ffi Review Action Decernber 17,2AO4 Permit Number: Project Name: ProiectTYPe: 04 00419 SubwaY North Commercial New Water and Sewer Service Plumbing Potable Water Review Plumbing Storm Drain Review Plumbing Sewer Drain Review lnterior Environment Energy Conservation Compliance Review Exiting Review Building Code Fire Compliance Review Height and Area Review Building TYPe ComPliance AccessibilitY Review Structural Review Mechanical Review Complies with approved Site Plan Review Actions Required for Approval Approved The site plan has been approved by the Building o"p"itl"t. Nine parking spaces are required and fourteen are Provided' Required to be installed, tested and inspected before covenng. Water lines are required to be installed' tested anJ insPected before covering' Must be installed according to plans provided' Required to be installed according to the uniform Plumbing code' Ceilinq and wallfinish must meet requirements of Sedtion 803 of the IBC' Meets the requirements of the 2000- iniernational Energy conservation Gode' Exiting complies with the International Building Code (lBC). ComPlies with the IBC' Height and area comPlY with IBC' Building is a TYPe VB' Provide pedestrian access to public way without using drivewaY' The structural calculations were made using ;;;;D;Jign category c a1o ^si!9 class c' lot t"" SitJClass d arrived at? lf a soil investigation was not performed'tl?.l tl" default Site Class snoitO be D and the Seismic Oesign Categorywould then be D' Please Ir-Jiil " soiis ieport or changes from the structural engineer' Prior to installation, provide seismic connection information for mechanical components or otn"i"o*ponent as per IBC Section 1621' 1210112004 1210212004 1210212004 1210212004 12l0a2004 1210212004 1210312004 1210312004 1210312004 12la3l2004 121c3t2a04 1211512004 1211512004 1211512044 clrv oF P.O Box 280 19 E. MainSt. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 3594A22 REXBURC A,\4ERICA5 FAVIY COi4]r.tUNfrY Review Action December 17,20A4 Permit Number: 04 00419 Project Name: Subway North Project Type: Commercial New Review ltem Miscellaneous Parcel #'s RPRlAMDLOOO05O Mechanical units closer than 10'from a roof edge require guardrails. Either move equipment or identify gaurdrails. Provide flood zone certificate. Approved 12t17t2004 CITYOF P.O Box 280 19 E. Main St. Rexburg, Haho 83440 Phone (208) 359-3020 Fax (208) 359-3022Review Action AUERrcAS F,\}IILY COIVIVUNTY December 17,2004 Permit Number: 04 00419 Project Name: Subway North ProjectType: Commercial New Review ltem Approved Required Fire Flow Water Supply Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Commercial Cooking Alarm Systems Other Comments Parcel #'s RPRlAMDLOOO05O 15OO GPM/TWO HOURS PREVIOUSLY ESTABLISHED. THIRry FOOT ACCESS PROVIDED. FIRE EXTINGUISHERS REQUIRED WITHIN TRAVEL DISTANCES, MINIMUM SIZE OF 2A10Be. NOT REQUIRED. NOT REQUIRED NOT REQUIRED NOT REQUIRED. A LOCK BOX IS STRONGLY RECOMMEDNED. PLEASE CONTACT THEFIRE DEPARTMENT FOR AN AUTHORIZATION FORM. 12t01t2004 12tA1t20A4 12t01t2004 12t01t2004 12t01t2004 12t01t2004 12t01t20A4 12t01t2004 121012A04 L2/13/04 MON 14:30 FAX 208 Jlg ZZ7L DEC-08-2004 l0:3lAM FR0M-ENGINEERED SYSTEMS JRW & ASSOC.@oo4 T-665 P.00t/001 F-030208-233-0528 Eunggimeeredl Systeuurs Assoeiates, J[**" MECHANICAL - ELECTRICAL - ENGINEERING 3I5 W. CENTER, POCATELLO, IDAHO 83204 TELEPHONE - 208-233-0s0 | FAX - 208.233-0529 D. SUDWEEKS, PE. R. RICE. P.E. December 8, ?004 Mr. Gary Richardson JRW & Associates 1I52 Bond Avenue Rexburg, Idaho 83440 Re: Subwuy - Rexburg Dear Gary, In response to rhe City of Rexburg Mechanicai Review Conmeats on rhe subjecr job, I offer the following response: l. Sizemic Resmainrs shown on warer heaterrank, All ductwork is exempt as it is smaller than 6ft2 cross sectional area, as per 1621.3.9. AU piping is exempr as size and weighr is less than 400lbs per' 1621,t.t. 2- Rooftop Unit RT-l will move 2' to the norrh to mairrrain a minimum of l0'from the edge of rhe roof. Fepl free to call if you have any quesrions- Siucerely, ENGINEERED SYSTEMS ASSOCIATES. INC. PLAN REVIEW RESPONSE SUBWAY December 6,2004 water and sewer service shall be installed, tested and inspected prior to covering. Plumbing potable water shall be installed , rested and inspected prior to coveri'g. Plurnbing srorm shalr be insta'ed accorcring to plans. Plumbing sewer sharl be instated according to the upc. ffitlff:iJ's| finishes shall meet flame spread requiremen* as set forrh in section See aftached drawing for pedestrian access to public way. |i; lJTilf J]" 31,H"#i::il1'*: :: ? tions A n A d di ti o n a r r.i re ex ri n gui s h er owner sha' be advised in regards to a fire department lock box. The building pad engineered fill at the new subway, was imported from the same pitas the engineered fill for the newDeseret Industrils. rnat is how the site crass ..c,,was determined. TIre flood zone certificare shail be providecr by silver Tree Builders. t2/7J/04 u0N rc:28 FAx I II 208 359 :Egn=RrY LINE @ oos -0 TozmtrHq! i r JRW & ASSOC. T- snp I \Jon Pfu6,E -.i o'>o, z !-- WATER _- SAN D,I_:9PERrY Lr'tE -.t ,tYlvq_------: EXlgTtNe slDE t",lALK fi#6 -q*"$ o .d .B -s$# ff NORTH 2ND EAgT