Loading...
HomeMy WebLinkAboutSTAFF REVIEWS - 05-00019 - Henry's Fork Office Bldg 9CITY OF REXBURC AMf R'CNs FAMILY COMMUN'TY P.O Box 280 '19 E fvlain St. Rexburg, Haho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action February 15,2005 Permit Number: 05 00019 Project Name: Henry's Fork Office 1 Project Type: Commercial New Review ltem ,E-fijAiffiDjpa'tiiff:npi|iir]:*j|,| j Water and Sewer Service Plumbing Potable Water Review Plumbing Storm Drain Review Plumbing Sewer Drain Review Building Type Compliance Height and Area Review Mechanical Review Energy Conservation Compliance Review Interior Environment Complies with approved Site Plan Review Accessibility Review Exiting Review Building Code Fire Compliance Review Structural Review Actions Required for Approval Water and sewer services are not addressed on plans. Required to be tested and inspected before covering. Required to be installed according to the Uniform Plumbing Code. N/A No pipiing shown on plans. Drains are required to be tested and inspected before covering. Building is Type VB construction. Height and area meet IBC requirements. Provide mechanical plans and sizing calculations prior to tenant finish. Energy requirements for envelope have been provided. Lighting and mechanical will be required at time of tenant finish. All ceiling and wallfinishes must meet the requirements of IBC Section 803. Provide snow storage as per zoning requirements. Meets requirements of the 2003 International Building Code (lBC). Provide and identify on plans, panic hardware as per 2003 IBC 1008.1.9. There is not a dimension from the back of the building to the property line. lf any part of the building (including eaves) then their will be firewall and rated roof details required. ldentify draft stop on plans. A geotechnical report is required by the architect. Please supply this report. Structural fill is also identified, please provide special inspections as per Chapter 17 of the 2003 Approved 0?/14/2005 02/14/2005 0?/14/2005 0?/14/2005 02/15/2005 0215/2005 02/15/2005 02/15/2005 02t15/2005 0?/15/2005 o2/15t2005 0215/200s 02/15/2005 02/15/2005 CITY OF REXBI"JRG ^MERrc.As fAVtrY COMil{UNnY P.O Box 280 19 E. lt/ain St. Rexburg, Haho 832140 Fhone (208) 359-3020 Fax (208) 359-3022Review Action February 15,2005 Permit Number: 05 00019 Project Name: Henry's Fork Office 1 Project Type: Commercial New Review ltem Miscellaneous Parcel#'s RP06N39E361201 Actions Reouired for Aporoval Approved International Building Code (lBC). Have set up a meeting with the special inspection firm, the contractor and the City Building Department prior to starting construction. Provide truss details prior to installation and frame inspections. Provide waterproof membrane on exterior wall. O2/15/2OOi ldentify flashing and weepholes at masonry. Make sure that siding meets the requirements of IBC Table 1406.2.1.2. ffi C'TY OF P.O Box 280 19 E lr4ain st. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 359-3022 REXBURG tu\4ERJCAS f^lltr| CollliuNrry Review Action February 1 5, 2005 Permit Number: 05 00019 Project Name: Henry,s Fork Office 1 Project Type: Commercial New Review ltem fff:p AmenttRev.ieui:.,:... ,:,,,t.r Required Fire Flow Standpipes Water Supply Alarm Systems Other Comments Commercial Cooking Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Parcel #'s RP06N39E361201 Actions Required for Approval 1750 GPM/TWO HOURS NOT REQUIRED. UNKNOWN WHERE PROJECT IS. NOT VICINIry MAP OR SITE PLAN SUBMITTED UNKNOWN WHAT OCCUPANCY IS...NOT ENOUGH INFORMATION. PROVIDE MORE INFORMATION FOR COMPLETE REVIEW. UNKNOWN WHAT OCCUPANCY WILL BE...NOT ENOUGH INFORMATION. UNKNOWN WHERE PROJECT IS, NO VICINITY MAP OR SITE PLAN SUBMITTED. NONE SHOWN, MINIMUM OF 2A1OBC FIRE EXTINGUISHERS REQUIRED WITHIN TRAVEL DISTANCES. UNKNOWN WHAT OCCUPANCY IS, NOT ENOUGH INFORMATION. Approved 02/05/2005 02/05/2005