Loading...
HomeMy WebLinkAboutREVIEW ACTION - 05-00342 - Artco Business Park - Office Space BuildingCITYOF ,1,t€Rrc/lS Frt lttrY 6.&{.lNlfy REXBURG P.O Box 280 19 E t\tlain St. Rexburg, daho 83440 Fhone (208) 359-3020 Fax (208) 359-3022Review Action November 14,2005 Permit Number: 05 00342 Project Name: Office Space Project Type: Commercial New Review ltem Approved Water and Sewer Service Plumbing Potable Water Review Plumbing Storm Drain Review Plumbing Sewer Drain Review Height and Area Review Building Type Compliance lnterior Environment Miscellaneous Accessibility Review No plumbing services are shown on plans. Requires approval before lines are installed. None shown on plans. Required to be installedaccording to the Uniform plumbing Code. N/A None shown on plans. Required to be testedand inspected before covering. Building height and area meet the requirement ofthe code and ordinances. Building is VB Wall and ceiling materials must mee the requirements of IBC Section 803. Plans must be prepared and stamped by alicensed professional. provide details thatidentify how ventillation will be provided. TheEast wall is required to be fire resistive. Ventillation through the eaves at this area is notan^option. ldentify Natural ventillation as perIBC Section 1209.4. ln certain cases, the IBC allows up to 3000 sq.ft. in a basement to be constructed without anaccessible route. lt is my understanding thatthe exception that would allow the basement tobe constructed without an accessible route alsorequires that a person with a disability would beable to conduct business or work at there. lf abusiness had offices and public spaces on themain accessible floor and offices in thebasement (under 3000 sq. ft.), then business could be conducted without discrimination. When the business space is entirely in thebasement, then a handicapped person in awheel chair could not do business or work atthe company renting the space. Access must 09t14t2005 09t14t20as 09t14t2005 09t14t2005 09t27t2005 09t27t2005 09t27t2005 ctTyoF iireRrcr{S rlt*|[l Gr&tut{ny REXBURG P.O Box 280 19 E tVlain St. Rexburg, ldaho 83440 Fhone (208) 359-3020 Fax (208) 3s9-9022Review Action November 14,2005 Permit Number: 05 00342 Project Name: Office Space Project Type: Commercial New Approved Complies with approved Site plan Review Energy Conservation Compliance Review Mechanical Review Exiting Review Building Code Fire Compliance Review Structural Review Parcel#'s RPRARBPOO2OO3O RPRARBPOO2OO2O be provided. Site plan has been reviewed and requireschanges. Provide lighting review as per the 2003International Energy Conservation Code. Provide mechanical design and calculations. Provide stair details. The North and East walls must be fire rated asper Table 602 of the 2003 International BuildingCode (lBC). The windows in the Eastwailmake up a greater square footage than isallowed by IBC Table 704.8. Th; roof structureand support over the stainvay on the North sideof the buiding must be fire raied. please identify on plans. The building to the North thatis identified on the site plan islhown 10'fromthe stairway structure. The 10' must be fromeave to eave. Any less an the stainvay is notallowed. Roof and ceiling must meet t'herequirements of IBC Section T04.11.providedetails identifying fire resistive construction forwalls, ceiling and roof. Provide cut-through drawing that identifiesbuilding structure, exterior sheething, roofcovering (and rating), stud spacing (and size),exterior wall water resistant barriei, masonryties, weep holes and flashing, etc... provide structural calculations. ciTy oF P.O Box 280 19 E [Aain St. Rexburg, daho 83440 Fhone (208) 359-3020 Fax (208) 359-3022 URC AMERjCAS f^i,u.Y @r.nvuMrY Review Action November 14,2005 Permit Number: A5 00342 Project Name: Oftice Space Project Type: Commerciaf New Review ltem Required Fire Flow Water Supply Fire Access Roads Fire Extinguishers Automatic Fire Extinguishing Systems Standpipes Commercial Cooking Alarm Systerns Other Comments Parcel#'s RPRARBPOO2OO3O RPRARBPOO2OO2O REQUIRED FIRE FLOW TO BE 15OOGPM/TWO HOURS NO VICINITY PLAN PROVIDED. HYDRANTSCAPABLE OF PROVIDED MINIMUM FIREFLOW REQUIRED TO BE WITHIN 5OO FEETOF STRUCTURE. PLEASE PROVIDE VICINITY PLAN. PROVIDED. NOT SHOWN ON PLANS. MINIMUM OF2A1OBC FIRE EXTINGUISHERS REQUIREDWITHIN TRAVEL DISTANCES ON EACHLEVEL OF BUILDING. NOT REQUIRED NOT REQUIRED UNKNOWN AT THIS TIME, PLANS INDICATEFUTURE TENANT NOT REQUIRED. A LOCK BOX IS STRONGLY RECOMMENDED. CONTACT THE FIREDEPARTMENT FOR MORE INFORMATION. Aoproved 09t14t2005 09t14t2005 09t14t2005 09t14t2005 09t14t2005 09t14t2005 09t14t2005 09t14t2005 09t14t2005 CITYOF REXBURC AM€RrcAS FAMLY CgqilIU'\&TY Review Action P.O Box 280 19 E Main St. Rexburg, baho 83440 Fhone (208) 359-3020 Fax (208) 359-3022 November 14,2005 Permit Number: 05 00342 Project Name: Office Space Project Type: Commercial New Review ltem Approved Meet with Kurt Hibbert (359-3020 ext. 314)concerning design standards. Parcel #'s RPRARBP0020030 RPRARBPOO2OO2O Development Standards Review