Fax (208) 359-3022Review Action
November 14,2005
Permit Number: 05 00342
Project Name: Office Space
Project Type: Commercial New
Review ltem Approved
Water and Sewer Service
Plumbing Potable Water Review
Plumbing Storm Drain Review
Plumbing Sewer Drain Review
Height and Area Review
Building Type Compliance
lnterior Environment
Miscellaneous
Accessibility Review
No plumbing services are shown on plans.
Requires approval before lines are installed.
None shown on plans. Required to be installedaccording to the Uniform plumbing Code.
N/A
None shown on plans. Required to be testedand inspected before covering.
Building height and area meet the requirement
ofthe code and ordinances.
Building is VB
Wall and ceiling materials must mee the
requirements of IBC Section 803.
Plans must be prepared and stamped by alicensed professional. provide details thatidentify how ventillation will be provided. TheEast wall is required to be fire resistive.
Ventillation through the eaves at this area is notan^option. ldentify Natural ventillation as perIBC Section 1209.4.
ln certain cases, the IBC allows up to 3000 sq.ft. in a basement to be constructed without anaccessible route. lt is my understanding thatthe exception that would allow the basement tobe constructed without an accessible route alsorequires that a person with a disability would beable to conduct business or work at there. lf abusiness had offices and public spaces on themain accessible floor and offices in thebasement (under 3000 sq. ft.), then business
could be conducted without discrimination.
When the business space is entirely in thebasement, then a handicapped person in awheel chair could not do business or work atthe company renting the space. Access must
09t14t2005
09t14t20as
09t14t2005
09t14t2005
09t27t2005
09t27t2005
09t27t2005
ctTyoF
iireRrcr{S rlt*|[l Gr&tut{ny
REXBURG P.O Box 280
19 E tVlain St.
Rexburg, ldaho 83440
Fhone (208) 359-3020
Fax (208) 3s9-9022Review Action
November 14,2005
Permit Number: 05 00342
Project Name: Office Space
Project Type: Commercial New
Approved
Complies with approved Site plan Review
Energy Conservation Compliance Review
Mechanical Review
Exiting Review
Building Code Fire Compliance Review
Structural Review
Parcel#'s RPRARBPOO2OO3O
RPRARBPOO2OO2O
be provided.
Site plan has been reviewed and requireschanges.
Provide lighting review as per the 2003International Energy Conservation Code.
Provide mechanical design and calculations.
Provide stair details.
The North and East walls must be fire rated asper Table 602 of the 2003 International BuildingCode (lBC). The windows in the Eastwailmake up a greater square footage than isallowed by IBC Table 704.8. Th; roof structureand support over the stainvay on the North sideof the buiding must be fire raied. please
identify on plans. The building to the North thatis identified on the site plan islhown 10'fromthe stairway structure. The 10' must be fromeave to eave. Any less an the stainvay is notallowed. Roof and ceiling must meet t'herequirements of IBC Section T04.11.providedetails identifying fire resistive construction forwalls, ceiling and roof.
Provide cut-through drawing that identifiesbuilding structure, exterior sheething, roofcovering (and rating), stud spacing (and size),exterior wall water resistant barriei, masonryties, weep holes and flashing, etc... provide
structural calculations.
ciTy oF P.O Box 280
19 E [Aain St.
Rexburg, daho 83440
Fhone (208) 359-3020
Fax (208) 359-3022
URC
AMERjCAS f^i,u.Y @r.nvuMrY
Review Action
November 14,2005
Permit Number: A5 00342
Project Name: Oftice Space
Project Type: Commerciaf New
Review ltem
Required Fire Flow
Water Supply
Fire Access Roads
Fire Extinguishers
Automatic Fire Extinguishing Systems
Standpipes
Commercial Cooking
Alarm Systerns
Other Comments
Parcel#'s RPRARBPOO2OO3O
RPRARBPOO2OO2O
REQUIRED FIRE FLOW TO BE 15OOGPM/TWO HOURS
NO VICINITY PLAN PROVIDED. HYDRANTSCAPABLE OF PROVIDED MINIMUM FIREFLOW REQUIRED TO BE WITHIN 5OO FEETOF STRUCTURE. PLEASE PROVIDE
VICINITY PLAN.
PROVIDED.
NOT SHOWN ON PLANS. MINIMUM OF2A1OBC FIRE EXTINGUISHERS REQUIREDWITHIN TRAVEL DISTANCES ON EACHLEVEL OF BUILDING.
NOT REQUIRED
NOT REQUIRED
UNKNOWN AT THIS TIME, PLANS INDICATEFUTURE TENANT
NOT REQUIRED.
A LOCK BOX IS STRONGLY
RECOMMENDED. CONTACT THE FIREDEPARTMENT FOR MORE INFORMATION.
Aoproved
09t14t2005
09t14t2005
09t14t2005
09t14t2005
09t14t2005
09t14t2005
09t14t2005
09t14t2005
09t14t2005
CITYOF
REXBURC
AM€RrcAS FAMLY CgqilIU'\&TY
Review Action
P.O Box 280
19 E Main St.
Rexburg, baho 83440
Fhone (208) 359-3020
Fax (208) 359-3022
November 14,2005
Permit Number: 05 00342
Project Name: Office Space
Project Type: Commercial New
Review ltem Approved
Meet with Kurt Hibbert (359-3020 ext. 314)concerning design standards.
Parcel #'s RPRARBP0020030
RPRARBPOO2OO2O
Development Standards Review