HomeMy WebLinkAboutREVIEW & CALCS - 02-00066 - Legacy Townhomes - Two 4-PlexesGo, ,y ffi"*A*ny STATE OF IDAHO www.ci.rexburg.id.us PO. Box 280 12 North Center Street Rexburg, ldaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 e-mail rexburg @ ci.rexburg.id.us 8/12/2002 William York William York Engineering 2329 West Spring Hollow Rd. Morgan, UT 84050 Dear Mr. York, I have reviewed the plans for the Rees Apartments (Legacy Townhomes) and have identified the foliowing discrepancies, additions or questions: 1. 2. 3. 4. Provide storm pond calculations. Get with the City of Rexburg Public Works Director and work out a Development Agreement. Identiff right-of-way lines. Identify handicap parking spaces along with signs identifiing them and the accessible routes into the buildings. Identify trash facilitie s. Please identify minimum design requirements for Rexburg, Idaho. Snow Load - 35 lblsq. ft-, Wind - 80 mph, Wind E4posure - C, Seismic Znne - 3 and Frost Depth -36? Provide minimum foundation reinforcement as per Section 1914.3.5 of the t997 UnformBuilding Code (UBC). Please remove all mention ofthe IRC in the plans. we are still using the 1997 UBC until 01/01i03. Identify foundation being constructed a minimum of 36" below grade for frost protection.. Please provide truss details as soon as you can get them from the supplier, but before framing inspection. Please provide detail of 2-hr. fue separation construction, Fire separation must be maintained from foundation to roof sheathing. Identi$ the separation between all units. Please subr,nit a copy ofthese apartment plans to the State of Idaho Electrical Bureau. 5. 6. 7. 8. 9. 10. 11. 12. 13. I have attached a copy of the Rexburg Madison county Fire Department review to the back of this document. Please resolve any issues identified by them. Please provide me with 2 new copies of any corrected plans. If you have any questions, please give me a call at 359-3020 ert. 324. Val Christensen Building OfFrcial c.c. John Millar Chris Huskinson Sincerely, REXBURG MADISON COI'NTY FIRE P.O. Box 280 26 North Center Rorburg, Idaho 83440 (208) 3s9-3010 1997 Uniform Fire Code Plan Review Building Name: THE IJEGACY TOWNHOMES Building Address: 1500 WEST, REXBURG DEPARTMENT Plan Date: unknown Review Date: 8-10'02 Stories: T$IO Type of Construction: V-N Occupancy Classification: R-1 OR R-3 Existing Floor Area: N/A New Construction Floor Area: APPROXIMiATELY 4256 SQUARE FEET/BUTLDTNG l-) .Required Fire Fl-ow (Appendix III-A): 1750 GPM/TWO HOURS Cornrnents: NONE 2).Water Supply (Article 9, Section 903) Required: YES Fire Hydrant, Location: ONE NEW HYDRAI{T SHOYIIN Fire Hydrant Flows: IINKIiIO$IN Fire Flow Test Location: N/A Fire Flow Supplied By: N/A Other Approved Water Source: NONE Water Supply Acceptable: SEE COMMENTS Fire Hydrant, l-,ocation Acceptable: SEE COMIIENTS Water Supply Comments: DRAWINGS NOT TO SCALE, IMPOSSIBLE TO DETERMINE IF HY:DRAI{T IS WITHIN PROPER DISTA}ICE OF PROPOSED BUTLDTNGS. I4ORE THAr{ ONE IftDRjAMr r[AY BE REQUTRED. prrEASE PROVIDE AIT ENGINEERI S ESTIIfATE OF THE FIRE FIJOW AVAILASLE FROM THE NEW HERA}TT. 3. ) Fire Apparatus Access Required: YES Acceptable: Width: X Complete Road Acceptable: Roads (Article 9 Sect.i-on 902) Length: X YES Surface: PAVED Comments: NONE 4).Access Roads and Water Supply, fncluding Fire Hydrants Are Requj-red To Be Installed And Made Serviceable Prior To And Durinq Time Of Construction (Artic1e 9 Section 901_.3): yES Cornrnents: IF NOT INSTAIJIJED PRIOR TO CONSTRUCTION, A STOP WORK ORDER WILL BE ISSUED. 5).Installation Of Port,able Fire Ext.inguisher (Articl-e 10 Section 1-002) Required: YES LocaLj-on Acceptable: NOT SHO$IN Type Provided Acceptable: NOT SIIOWN ComMeNTs: EACH UNIT TO IIA\IE A MINII4TIM oF oNE 2AIOBC FIRE EXTTNGUISIIER INSTALLED. 6).Automat,ic Fire Extinguishing Systems: (Article l-0 Section 1003 Required: NO Type Of System Being Installed: Sprinkler System Monitoring Required (Art,j-cle 1-O Section 1003.3) Required: NO Comments: 7).Standpipes (Articl-e 1-0 Section IOO4) Requi-red: NO rTrzna Paarri rarl ..J.YV Comments: B).VenLilating Hood And Duct Fire Extinguishing Syst.em (Article 10 Section A006.2) Reguired: NO Type Being Provid.ed: Automatic Fuel Shutoff Shown (Art,icle l_0 Section 1006.2.4): Portabre Fire Extinguisher shown (Article i-0 section i-006 .2.2) , Comments: 9) .Fire Alarm Syst.ems (Article l-0 Sect.j_on 1007)Requj_red: yES Type Of Syst,em Required: Manual: Automatic: X Both: Type Of System Being Provided: Manual: Automat.ic: X BoLh: component,s of syst,em shown: smoke Detectors: x Heat. Detectors: Manual Pull Station: Sounding Devices: Visual Dewices: Door Holders:Duct Detectors: Flow A1arm: Sprinkler valve Monitoring: Fire Alarm system Acceptable: sEEcot{Ir{ENTS comments: ARE THERE ANg HANDTCAenED uNrrs rN THrs pRoJEcr? rF so,TIIE IIANDTCAPPED IINTTS NEED TO HAVE NONW/STNOBES INSTAIJI'ED. 10).other corrections That Are Required By special occupancy or Condit.ions: Pl-ans As Submitted Are Acceptable: NO, PLEASE ADDRESS ABOVE NOTEDITEUS. Plans Checked P]ease furnish manner: By: CHRIS HUSKTNSON comments back to the plan Written Comments: X New Date:8-10-02 reviewer in the following Plans: X For: Plan #: Location: From: Structural Calculrtions Legacy Townhomes 4-Plex Legacy Townlrouses (one building) William York Company, L.C. 24 July2002 2329 W. Spring Hollow Road Morgan" Utah 84050 (801) 876-3501 Design Criteria 97 UBC: RoofLoad; Live Load (PSF) Dead Load (PSF) Floor Load; Live Load (PSF) Dead Load (PSF) Seismic Zone:2 Wind Speed: 80 nph E4posure: C Material Properties & Assumptiqns Concrete PSI (fc'): 2500 (found.), 3000 (slabs), 4000 (susp. slabs) Concrete Reinforcement: ASTM ,,4.615 Grade 60 & 40 Site Conditions: Dry & Stable granular based, 1500 PSF Bearing Capacity, Granular Based Backfill (KH:35 pcf), Slope not to exceed 204/o,Sethek from slopes is minimum of 25' Dimensional Lumber: Hem or Doug Ftr #2 & BTR Steel: ASTM ,{36 Use Simpson straps and tie downs, and meet nailing, reinforcement and other structural requirements as noted on the drawing and within the pages of this document. These structural calculations are based on conditions and assumptions listed above. If the conditions listed herein are not mst or are different it shall be brought to the attention of the engineer. Roof Truss and beam system to be engineered by the supplier. This engineering assumes that the building site is dry and stable, a high water table or adverse soils such as plastic clays, fills etc. could cause futwe flooding, settlement, site instability, or other adverse conditions. Verification of and liability for the soil bearing pressure, site stability, and all other site conditions, including site engineering as required, is the responsibfity of others. These calculations and engineering are for the building structure only and do not provide any engineering analysis of or liability/warranty for the non- structural portions of the building, or the site itself. William York does not assume the role of "Engineer of Record" on this project. The purpose ofthese calculations and engineering is to help reduce structural damage and loss of life due to seismic activity and/or high wind conditions. The contractor shall verify all conditions, dimensions and structural details of tlrc drawing. Multiple use ofthese calculations is not permitted. 35 l5 40 l0 ril0rilttlrl{0 All exterior walls shall be sheathed wrth7ll6' APA rated structural wood panel. Block all horizontal edges I %" nominal or wider. Sheathing shall extend continuous from floor to top plate and be nailed at least 4' O.C. along sill plate. Nails shall be placed not less ttlelrtt/2" from edge ofpanel and driven flush but shall not fractwe the surface of the sheathing. Extend sheathing over gable end to wall joints & over rim joist between floors and nail to rim and wall plates 6'O.C. Shear Wall Schedule type Sheathing Typical 7/16" one side SW-l 7/16" one side SW-2 7/16" both sides Nail Edge 8d 6. O.C. 8d 4'O.C. 8d 4" O.C. Field Anchor Bolts 10" o.c. %" 32" o.c. 10" O.C. Yz" 32" A.C. 10" O.C. Y2" 32" O.C. Typical braced wall; glue & nail or screw gypsum wallboard 7' O.C. & install CWB bnacing The following general rcquirements shall be followed during constructionl l. Contractor to verify all dimensions, spans, & conditions and notiS engineer of any errors, omissions, or discrepancies prior to construction 2. Use Simpson A35 ties 16' O.C. between cantilevered joist and sill or top plate. 3. Use Simpson H2.5 ties each end of each truss. 4. Sheetrock to be glued and nailed/screwed @7" O.C. for all SW-4 walls & braced walls. 5. Foundation reinforcement: As per plan 6. Use 2:#4bars contimrous for all footings 2: # 4 bars each side of openings &2 # 4 bars top & bottom extend 36" beyond opening 8. Use /2" xl0" J bolts 32. O.C. all foundation walls 9. If discrepancies are found, the more stringent specification shall be followed. 10. All rrrultiple beams and headers to be nailed using 16d two rows 12' O.C. I l. Contractor shall :Nsure that all materials are used per manufactures recommendations. 12. Site engineering and liability shall be provided by the owner/builder as required. 13. Connect beams & headers over 6 ft., to trimmers with appropriate connectors/hangers. 14. Contractor shall assure that footings are properly drained and that soil is dry and that footings rest on undisturbed native soil 30" below finished gade and that building horizontal clearance from footings to ascending slopes be a minimum of 25 feet. 15. The contractor shall conform with ail building codes and practices as per the 97 UBC. 16. Use balloon framing method when connecting floors in split level designs. 17. Nail all braced walls to floor joist using 2: lff 16' O.C. Add additional floor joist as reqd. 18. Use double floor joist for Cant. Shear wall sections under window or door trimmers. 19. Provide joist and rafter hangers as per manufacturers specifications. 20. Foundation steps shall not exceed 4 feet or Yzthe horizontal distance between steps. Horz. rebar shall & 12" O.C. tlrough step downs and extend 48" either side of step 2l.lf garage return walls are less than 32" wide then extend headers across return walls with 2 king studs on either end extending from the top of the header to the bottom plate. 23. Use a minimum of 2-9 Yz" LYLs for all headers carrying girder loads. 24. Allow foundation 14 days to cure prior to backfill 25. Use I 1/8'wide timberstrand or equiv. for all rim joist 26. Provide solid blocking through structure down to footing for all load paths. Plan: REES.4'4IZ84- Date:23JULY2(t(r2 Location: LEGACY TOWNHOMES, REXBURG TDAHO rynd Loading Calculations FrontExphojected Area tethod Wlnd Design Coefficients Ge FactorP=Ce*Cg*Q*l neigtrt Ep.D Ery.Cf=Dgsign Pressure zero to t g 1.39 1.06Ce=Combined-Height, eposure, gust factor ZO 1.45 1.13Cg=Pressure Coefficient ZS 1.S 1.19g:Wind.Stagnation 30 1.54 I.Zgl=lmportance Factor q fector Wind (mph) q (psD ttt (8{lf = l: 1.0 Expoeurc tilind Speed = Roof Slope * Roof Angle (deg)- cq= P(Prf| s 6e'gq'0"'1 15+ft. 0-15 ft. Horlzontal Force Roof Uplift P(Psf)= Total Uplift (lbs)= UPlift (pry= Roof Diaphragm Shear Total Shear (lbs) Lefi Wall Length Right Wall Length Crldcal Wall Leqgth (ft)= Left Walt Dead Load (ptf)= Left Wall Critical Length (ft)= Right Walt Dead Load (plf)= Right Wall Criticat Length (ft)= Left Right Shear Walt Loads (plf) TotalLeft= TotalRight = c 80 5 t12 22.62 1.3 Section Roof Height WallHeight Sine = 0.3846 Exp.B 0.62 0.67 0.72 0.76 Force (lbs| 10681 24046 34726 8 10 12-1082234 -1353257 -1624281 -1192117 -1490612 -178910S 110 31 Ce 1.13 1.06 70 12.6 16.4 1 widrh 76 76 24.09 22.60 Item Roof Walls 80 90 16.4 20.8 100 25.6 Height (ft} 5.83 14 Wind Load 24.09 22.60 Total Calculate Uplfft, Force Regd to preyent OT (lb)Parnllength (ft) z 7.69 16368 7g 34726 56 56 271102 0 298573 0 -269'r63 -29863/ 3 404675 445881 Helght 5.8 14 4 -544187 -595129 6 -81',1210 -893623 310 310 Pfan: REES.4'4;?84- Date: 23 JULY 2002 Location: LEGACY TOWNHOMES, REXBURG IDAHOWind Loading Calculations Projected Area llethod Wind D,erign Cosfffcienb P=Ce*Cq*q*l P=Design Pressure Ce=Combined Height, eposure, gust fac'tor Cg=Pressure Coefficientqewind Stagnation l=lmportance Factor q factor Wind (mph) q (psO qr (80) = l. 1.0 Exposure Wind 9peed = Roof Slope s Roof Angl€ (degF cq= P(Pr0 - Cercqrqs'l 15+1. 0-15 ft. lforkontal Forcs Slde Exp. Ce Factor Height Ep.D zeroto 15 1.39 2A 1.45 25 1.5 30 l.U Exp.C Exp.B 1.06 0.62 1.13 0.67 1.19 A.72 1.23 0.76 100 1'10 25.6 31 Height (ft) ce 5.83 1.13 14 1.06 28 Roof Uplift P(Psf)= Totral Uplift (lbs)= Uplift (ptf;= Roof Dhphragm thear Total Shear (lbs) Front Wall Length Back WallLength Crltical }Yall Length (fr;= Front Wall Dead Load (ptf)= Front WallCritical Length (fi)= Back WallDead Load (plf)= Back Wall Critical Length (ft)= Panet Length (ft) Front Eack $hear Wall Loads (ptf) TotalFront= TotalBack = 70 80 12.6 16.4 16.4 1 c 80 5 t12 22.62 1.3 24.09 22.60 Item Width Roof 28 Walls 28 7.69 16368 79 12794 39 64 267747 0 346804 0 90 20.8 Section Roof Height WallHeight Truss Span Sine = 0.3846 Height 5.8 14 4-534352 €92851 Wind Load 24.09 22.60 Total 6-802020 -1039577 Force {lbs} 3935 8859 12794 I -1069688 -1386302 Galculate Upllft, Force Reg,d to prevent OT (lbe) 23 -266684 -400018 -346126 -519488 't0 12 -1337357 -1605025 -1733027 -2079753 1U 100