Loading...
HomeMy WebLinkAboutFIRE PLAN - 01-00049 - Dr Brad Egbert Office - New CommercialREXBI'RG MADTSON COT'NTY FIRE DEPARTMENT P.O. Box 280 25 North Cenler Re:<burg, Idaho 83440 (208) 359-3010 I Building Name: Dr. Brad Egbert Medical Office Building Address: Bond Street Stories: one Type of Construction: V-l[ Occupancy Classification: B Existing Floor Area: Nr/e New Construction Floor Area: Approximately 24OO sq. feet 1).Required Fire Flow (Append.ix III-A): 1'500 GPM for thro hours Comments: Iilater suppJ-y may be reduced by 50% if 'rr approved automatic sprinkler syste'n is instalLed. 2).Water Supply (Art,icle g, Sect,ion 903) Reguired: YES Fire Hydrant, Location: Bond Street: B-54, 8-56, B-58 Fire Hydrant Flows: OK Fire Flow Test l-.,ocaEion: Sa'ne Fire Fl-ow Supplied By: FD Other Approved Wat.er Source: None Wat.er Supply Acceptable: YES Fire llydrant lrocation Acceptable: YES' Wat,er Supply Cofiments: NONE 3. ) Fire Apparatus Access Roads (Artiele 9 Section 902) 1997 Uniforrr Fire Code Plaa Review Required: YIES Accept,able: width: YIES Turning Radius: N/A Clearance: OK Complet.e Road AccepLable: Length: tlES Surface: Paved Plau DaLe: 9/25lAL Review Date: LL/5/OL Vehicle Vertical: OKGrade: OK Turn Arounds: OK YES 4) .Access Roads and water supply, Includ,ing Fire Hydrants Are Reguired To 'ee inst.aLled And Made Serviceable Prior To And' During Time Of Constrrrct,ion (Article 9 Sect'ion 901'3) : YES Comments: 5).InstaLlation Of portable Fire Extinguisher (Article 10 Section 1OO2) Required.: YEs Location AcCeptable: Not shovrrr Type Provided Acceptable: Not Sbowa Corments: Need, to provid.e at least two fire extingrishers, ninimrm size of 2A-108C 6).Automatic Fire Extinguishing Systems: (Article L0 Section 1003 Required: NO Type Of System Being Installed: sprinkler system Monitoring Required (Article 10 Section 1003-3) Reqr:ired:Comment,s: 8).Fire Alarm Systems (Article 10 Section 1007)Reqqired: NO Type Of System Required: Manual: Automat'ic:Both: Tlpe Of, System Being Provided.: Manual: AuLomatic: Both: Components Of System Shown: Smoke DeLectors:Heat Detectors: Manual Pu1l St.ation: Door Holders: Sounding Dewices: Visual Devices: Duct DeLectors:Flow Alarm: Sprinkler Valve Monitoring: Fire A1arm SysLem Accept'able: 10).Other Corrections That, Are Requined By Special Occupancy Or Conditions: None Plans As Submit,ted Are Accepuable: IIES Plans Checked By: Chris Euskinson Please furnish comrnent.s back to the plan nanner: Written Cornments: New DaLe:11-5-01 reviewer in the following Plans: