HomeMy WebLinkAboutFIRE PLAN REVIEW - 99-00022 - Taco Time - RemodelRE:|BT'RG !{ADTSON COUNIrY FIRE DEPARII$EIIT
P.O. Bo:r 280
26 North Center
Rexburg, Idaho 83{40
(208) 3s9-3010
199{ Unif,orn Fire Code
PLan Review
Building Name: Taco TiJne
Building Address: 274, $ouFh ?nd We,St
Q.l-nri aq. Ono+
Occupancy Classification: A-3
PLan Date: 04123-9.8
Revier Date: 05-07-99
Trrrro nf Cnn qt rrrr-t i nn ' \/-N! v |\Js v! vvrru s! uu L+vrr . J-..-5J
ExistinE Floor Area: 1'369
New Construction Floor Area: 691., Tota] ,Bquare footAge=2r,060
1) .Required Fire Flow (Appendix III-A) : 1,.500 g.p.nt.
2).Water Supply (Article 9, Section 903) Required: Yes
Fire Hydrant Location: C-28 2nd Weet e 3nd Squth' S:83 ?.45 South.
Znd We.st
Fire Hydrant Flows: .8r.-Q08-g-"P,-rnJ
Fire Flow Test Location: Satnp
Fire Flow Supplied By: Fi{e ,Deoa$,t'rFeFt
Water Supply AccePtable: Yes
Fire Hydrant Location Acceptable: Yp,s
3.)Fire Apparatus Access Roads (Article 9 Section 902)
Required: Ng Comments: Aqces,s ffom fnai{r road,s
4 ) . Installatlon Of Portable Fire Extinguisher (Art.icle 10 Section
1002) Required: Yes Location Acceptable: Not shown
Type Provided Acceptable: Mi.nimum 2*A "1-O-BC
5).Automatic Fire Extinguishing Systems: (Artlcle 10 Sectlon 1003
Plan Review
Page 2
Required: No
6).Standpipes (Article 10 Section 1004) Required: Ng
?).Ventilating Hood And Duct Fire Extinguishing System (Article 10
Section 1006.2) Required: Yes Comments: SEa gttached UFC Section.
8).Fire Alarm Systems (Article 10 Section 100?) Required: Ng
Plans As Submitted Are Acceptable: Yes
Plans Checked By: Dee.. Owqns Date: 05:07-98.
Please furnish comments back to the plan reviewer in the following
manner: Providp inforr.[il!.ioe on venLi]alins hoBd and duct fire
extinguishing system.
tjROM: $ection 1006
Article l0
Section 1006 - PROTECTION OF COMMERCIAL COOKING OPERATTONS
1006.1 Ventilating Flood and Duct $ysterns. A ventilating hood and duct-system shall be
prurvided in accorlance with the Mechanical Code for cornmercial-type fbod heat'processing
equipment that produccs grease-laden v$Ftrs-
1 006.2 Fire-extinguishing System.
1006.2.1 Where required. Approved automatic fire-extinguishing systems shall be provided for
the pnotection of commercial-type cooking equipmcnt-
EXCEPTION: The requireinent for protection does not include stearn kettles and steam tables or
equipnent which as used does not create greaseJaden vapors.
1006.2.2 Type of system. The sy$tem used for the protection of cornmercial-type cooking
equipment sirall be either a systbm lislgd for application with such e-quipment or an automatic
fiieixtinguishing $ystem tlnt is spcifically designed for such application.
Sysrems shall be installed in accordance with the Mechanical Code, their listing and the
manufacturer"s instmction. Other systems shall be of an approved design and shall be of one of
the tbllowing types:
1. Automatic sprinkler system.
2. Dry-chemical extinguishing system.
3. Carbon dioxide extingrrishing qysteffi.
4. Wet-ehemical extinguishing system.
1006.2.3 Extent of protection.
1006.2.3.I General. The automatic fire-extinguishing system used t9 protect ventilating hoods
and ducts and cooking appliance shatl be installed to inctude cooking sqrfgpe1, d-eep fat {t-VtR
griddtis, upright broiieri, chartroilers, range_topu q4 grills. Frotection shall also be-provided for
lne enetosed flenum spsce within the hood ahove filters and exhaust ducts serving the hood'
t006.2.3.2 Carbon dioxi{e systems. When carbon dioxide systems arc used there shall be e
nozzle at the top of the ventilating duct. Additional nozzles that are symmetrically ananged tct
give uniform di'stribution shall be installed within vertical ducts exceeding ?0 lbet (6096 mm)
Ind horizontal ducts exceeding J0 feet (15 240 mm). Dampem shatl be installed at either tle top
or the bottom of the duct and ihalt tre arranged to operate automatically upon activation of the
fire-extinguishing system. When the dampi is installed at the top of.the &Yt, the top nozzle
shall be immediately below the damper. Carhon dioxidc automatic fire'extinguishing systems
shnlt be sufticientlfsized to protect all har.ards venting through a common duct simultaneously.
nA6.2.4 Automatic power, fuel andverrtilation shutoff.
1006.2.4.1 General. Automatic fire-extinguishing sy$tems shall be intcrconnected to the fuel or
cuffent supply fur the cooking operfltion and ananged to automatically shut offall equipment
under the hood when the system is actuated.
Shutoffvalves or switches shall be of a typo that require manual operation to resst.
1006.2.4.2 Carbon dioxide systems. Commercial{ype moking equipment protectedby an
automatic carbon dioxide extinguishing sy$tem shall be arranged to shut off the ventilation
system upon activation.
1006.2.5 Speciat provisions for automatic sprinkler systems. Commercial-typ cooking
equipment protected by automatic sprinkler systems shall be supplied from a sepa.rate, readily
accessible indicating-type control valve that is idcntified.
Extinguishing systems shnll be serviced at least every six months or after activation of the
system. lnspcction shall be by qualified individuals, and a Certificate of Inspection shall be
forwarded to the chief upn oompletion.
Fusible links and automatic sprinkler hends shall be replaced at least annually, and other
protection devices shall be serviced or replaced in accordance with the manufacturer's
instructions.
EXCEPTION: Frangible bulbs need not be replaced annually.
1006.2.6 Manual system operation. A rendily accessible manual activation device installed at an
approved location shall be providod for dry shsmical, wet chemical and cnrbon dioxide systems.
The activation device is allowedtobe mechanically or electrically operated. If electrical power
is use{ the system shafi be connected to a standby pow€r system and a visuial means shall be
provided to show that the extinguishing system is energized. Instnrctions for operating the
fire-extinguishing system shall be po$ted a{iaoent to manual activation devices.
1006.2.7 Port*ble tire extinguishers. A sodium bicarbonate or potassium bicarbonate
dry-chemical.type portahle fire extinguisher having a minimurn rating of 40-B shall be installed
within 30 feet (9144 mm) of c,ommercial food heat-processing equipment, a$ measur€d along an
unobstructedpath of travel, in accordance with U.F'.C. Standard l0-1.
1006.2.8 Operations and maintenance. The ventilation system in connection with hotds shall be
operated at the required rate of air movement, and classil-red grease filters shall be in place when
equipment under a kitchen grease hood is used.
lf grease extractors are installed, they shall be operated whsn the commercial+ype cooking
equipment is used.
Haodg, girease-removal devices, fans, ducB and other appurtenances shall be oleaned at intervals
necessary to prevent the accurnulation of grease. Cleanings shall be recorded, and records shall
state the extent, time ard date of cleaning. Such records shall be mainbined on the preinises.
Sprinklers used for the protection of ftyers shall be listed for that application and installed in
accordance with their listing.