Loading...
HomeMy WebLinkAboutALL DOCS - 13-00056 - 4201 Woodland Dr - County MechanicalI 35 N. 1$ E., Rexburg, Id 83440 o\x/NER'S NAME lAr{Ci,rrw,,. tltr'l\ls. PROPERTY ADDRESS OVNER'S CONTACT PHONE Building Sofety Deporfmenl City of Rexburg Permit# O\X/NE R'S EMAIL ADDRESS \4a:\C @ \<artc,r'r'c.V\ r:.n^{\ . C.uv-r-,. CITY OT REXBURG AweIu\ family {}ommtnity Requircd!!!Mechanical Mechanical Conffactor's Name ness Name R,. t\Se J< Addres a\tate \chrho zip_&leg Phone (4D) qcr<-c^<:o E-uil b\c\cEha*\g O e, msn.Cocn (COMMERCIAL/INDUSTRIAL) Total cost of mechanical system (ConttactedAmount) $ (ncludu tbe con of rnaterials installed regardless of tbe parg vrppfiing it. Tbe Jeu listed unfur tbis inspeetion jpe shall appl1 to an1 and a// meebanieal installations not spurfm@ mentioned elseabere on thisforw)tr Up to $10,000 (tsEl-eas!-af-SysI€ls x 0.02) + 60 = $I Between $10,001 - $100,000 ( (total cost of s!'stem - 10.000) x 0.0i) + 9260 = g I Over $100,001 ( (total cost of system - 100.000) x 0.005) + 91,160 = g RESIDENTIAL New: Siagle Faaily Dwelliag, iacluding all buildiags vzith witing beiag consructed oa cach ptopetty. (xBased oa liuing space, see defrnition bclow) tr Up to 1,500 sq ft - $130 .F 1,501 to 2,500 sq ft - 9195tr 2,501 to 3,500 sq ft - fi260 I 3,501 to 4,500 sq ft - 9325! Over 4,500 sq ft $325 plus $65 fot each additional 1,000 sq ft. ot pottion thereof ($325 + ($65 x # of additional 1.000 sq. ft. or porrion thereo0). New: Multi-Faaily Dwclliag (Conu:actots Oaly) I Duplex Apartment $260I Three or more multi-family units: $130 pet building plus $65 per unit: ($130 x # of buildings) + ($65 x # of units)n Existing Residence, Modulat, Manufactured ot Mobile Homes and Detached Shop: 965 fee plus $i0 per**HVAC equipment being installed up to the maximum of the coresponding sq. ft. of the building ($65 + ($10 x # of fixtures)) MISCELI-ANEOUS a Plan Check $65 per hour I Technical Service: 965 per hour I Gas Line: $65 El Water Heater Replacement $65 I Requested Inspection: $65 I Fireplace/Solid Fuel Buming Appliance: 965 per inspection xl-iving Space - space within a dwelling unit intended fot human habitation which may reasonably be utilized for sleeping, eating, cooking, bathing, washing, recreation, and sanitation purposes. An unfinished basement is considered part of the living space.**Examples of HVAC Equiprnent-furnace replacement, solar, water heater, etc. filc^ /g* iqvl ziz*lr z/zZ /zctrg DateSi celPr,on9w}703 - a ntfactor License number & Exp. date ,d;il,r, a*kr6 ReqBy Ttson w,'^ YnYJn*i"l'-W -to94, Pay /Time ReQ'O Comm'f Res lnsPector's RePort ff rJN'A DWGS *rrt*o*'t lcfloN NDISAPPROVED"o*t APPLI.ABLE NRNAL EotoNortNsFEcr .rfftnoveo/"fyli-ton REQUIRED: Signed Unitc ' Olficc CoPY F'rlF'c0o3 Ric.t e,crno'rtedged -nr*'JoDcogt Receipt Number: ,:..1 ,.' ,. .i. ... -'.:' Orlglnal Fee 4Pount .:.:: Nmou$ . .,. ::',r''.,Pald . . . lential Fixtures $195.00 Total: $195.00 $195.00 40 59-3022 PayerlPayee Name: KARTGHNER HOMES OF IDAHO $ 195.00 FEB 2 2 ZU13 \ Z lL [1] F (f) z+oz-urF{fi]u(f)rflM*' f l l I ,l>i KI BI 3tr K I I Ila)ttz:lu -TFtuI (f) []l I I i dV(lr I rI)rt N(') 3t.^ it o NqS- EE=s {S d:E f $sra xl F I Irl I I I i:e=S,^ 583 $rn{R T!sal* .-ln"lEjl? \E\E'- ri L-f t r J- j A /l z_ H18ON.-]=r-FfE-- ?i:SJS' TmTMNC-*"f#sffi$r'Nrz rf:';*''X;ii,;:g''@ nocsaloaaanntuwlll \ l"l\l IrI I' sr l E F; I *d*"* |,L€'fd lB r+ra?r€ >,a &rl 16 NM|mEzB'r,i@w |tl6r iLX *: =llll EIt- -l / =,, /_,il1,1n :l[ t / /,ilffifiilnffiIffiil| | ill];lti lfllru|]lilIilllt I' \\[ti] 1, tillt1tffi|tlil|]l1t / Itlflr{tllllllil]lllllillllllllllllllllll I lll,l ,iljffi lllrll,,l,r llil\lll,,,wfi ,W-R N-Z li - \L'r--:::Hir NL--f + *l -[} li I -lL ll - )Z:* l),/ ,", tJ | :Iru t;z t8 |:: tit|::: lelliEE l9 l!i; Er]!:l ll: f;tI UtlzV 8q d$ lrSl l4sl 165 $E Lmsl tHil tE3 zl PIae/,ub Ud rl$6lvq6E q36 ii9E3; *q 9 tl fft; *g B$uL I 6 ?!>;uLarl'u1qLta (D m m{4@)hW*"fffiff" NZ n;:ii;"i;:i;wl::t,rl0||||lLlBil-srnaH utN\)raw *j/' rol ssxaaagnucluwlln \ l$ll\ il' * E;,.. @drznc)@ L€ 'Idarfr3 )&d s Irc.MtazBtHr Norw rJlrtN6 il$ |: li; ffi 9 I owdr'trl@ av!€ >4 rytlNO€ffi !ZBt! r NAVT lslil*l tull 5 qfi-.. -l F, ol: tr5€$ (Dllil-l p al, $:iv <ldurl,L (m l Fuo 0Z o P /l/t/ ^(trt rEO,ae I'p _i I I L t I **p*x* p> | ttf il,i:iitill;,, tfrl$gl | * I rw uxoaaenuuuw ut ) | __ " lslllql I I'*$$."1 ffidr4l1c4E'M| 9ayrgi >-d gta @ffi32@4tWw d)T]Nl6 (q iix ldll!g t8il;:I t- ll.l li, ll*il^ l:E I lJ t:i l9 liE tluiitE4D9 f -i9lul lr;lr n,,,fis9-!l @-M@bw JNrdilr'JrL!*.t"#ffiffi" N.K rf ni";,;il j,',i*,**p -lril\ i" k 84... da Dltffi L€ 'IOi €rtf€ t-a gLd lNo€ffiazBrHrrclw i .lniTINi6 N (D t 0tb ozio=oi n- ll-<tt, n,IfroE:6(;F:MaBs + \l 5l;r*sg Hl;ol84, (6 )\"/ // $f;* EoqxcfipY ql :rE fl*+ 6$ HlN'qE6 5t:s 0-oiX <( <)V I\< uv<{ / I : I ri S B E 3 u\9{ o u OZ{g Ez E 2 n 0 a a t IlUA>lu:' ^;Flfi 8It t: ooz 6 E il U HI E { ii(i I I I I E!,!$:E:l iiililiil:iiiis iliiiEiil;;:::iri T#ffi' 5nEfiilr'JNs-*#ffi,s?'Nrz 9ttz-6e9 (802)tqt|a 01 s77v! aBv1Jut gN'Jsaa1laf, 8948 SANOE A1NHJJAW @vrg: )'@ ga NO€@g azBtH r rc!fi 9ttz 629 (gaz)t0tt8 0l s71vJ 04vgltu4 AN1JStAlIgf, 8918sxu0H aaNHcJaw i(Dl ar{y ts[1.. B'0t l I+&iot) Ie"i4 49 ""_3 =9 i1* = 4; }ai?i E" a,-Ze E Z=t Ylrg+F F s ,5ts ' J J JJ O ;)l a r:,ag h6!6d!6 .il! Pl a b:irl{r,i-=I 9 I F dorhs.d.ad6ooiri,,i,dlid! i j, 3l F 81<H sl; 6 2; 93.Esaz;{=EEdE aEEz:F:s-lZ€?!?E=:=I e41 Zt +k **ffis:* W ln t#["tiui;"i*,*.1]p #r ts Irli, I s Nli,"l 4rd 9rnca €lvfd )fr s rNOffiarzetEr Noaw lllTNo iN @s@)bfu JNtdJdNtJNd*#ffigT". \z 9ttz 629 (aoz) ta?e8 at s1lvd a4vqltua g$qtst,I7af, a92tSANOH AANHCJAW W @v1€! )-! g INOffiaMt! r Notw-t rrnr::"i#,!"i!f :"j,ru l*lil '\1 ii, ll iie$li1"1. Fuo u rou0 v (D I c: r Et !F*d RY x ;i R5{r r :g &oi6r sE 12 $E -fis t e l I >> 6lr:t FI 5t S| ;p lJ6! Il!j/ Sii l9l *rt I{E: .E/ FBI I 3;&ifi m{4(@)stu*"f;il8!$HgT'NZ mjiit(i:!i',i:f,,W aoc stnouuannuxwttt 'l carv r=a l;llll,1,$h.l"l^l oryo r!n*l i @rr€ *oa &^ aI N@Un€ 3rre>*! r NOBrt I |o it rf l6 dl iix 5,1oiN2aor39U>io=:3N3P- JTIIm<6z>if.$'vl c tJI eIuilq6 I A IIEE tY t:5I liE lel|;Etz t.Flc\ lsclo lctl= lT;---5qlt2 IrFf zo of,{vod>z'<ZrU(ol Ft < l zun ai sE qbl'rL____ _ __l ..1 U 10irv ;,u Riti x<'*i* Il Hill gr iliJI REScheck Software Verston 4,4.2.3 Energy Code: Location: Construction Type: Building Orientation: Conditioned Floor Area: Glazing Area Percentage: Heating Degree Days: Climate Zone: Construction Site: Gom pl iance Gertificate 2009lEcc Rexburg, ldaho Single Family Bldg. faces 135 deg. from North 1981 tt2 15% 8693 6 Owner/Agent:Designer/Contractor: Compliance: 1.1% Better Than Gode Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Orientation: Front Window 1: Vinyl Frame:Double Pane with Low-E SHGC:0.35 Orientation: Front Door 1: Solid Orientation: Front Wall 2: Wood Frame, 16" o.c. Orientation: Left Side Wall 3: Wood Frame, 16" o.c. Orientation: Back Window 2: Vinyl Frame:Double Pane with Low-E SHGC: 0.35 Orientation: Back Door 2: Glass SHGC: 0.35 Orientation: Back Wall 4: Wood Frame, 16" o.c. Orientation: Right Side Basement Wall 1: Solid Concrete or Masonry Orientation: Front Wall height: 8.0' Depth below grade: 6.5' Insulation depth: 8.0' Window 3: Vinyl Frame:Double Pane with Low-E SHGC:0.35 Orientation: Front Basement Wall 2: Solid Goncrete or Masonry Orientation: Left Side Wall height: 8.0' Depth below grade: 6.5' Insulation depth: 8.0' Basement Wall 3: Solid Concrete or Masonry Orientation: Back Wall height:8.0' Depth below grade: 6.5' lnsulation deoth: 8.0' Window 4: Vinyl Frame:Double Pane with Low-E 2033 498 90 42 387 499 64 42 387 461 44.0 21 .0 21.0 21.0 21.0 19.0 10.0 0.0 45 21 31 12 22 22 220.350 18 22 21 0.0 0.0 0.0 0.0 0.350 o.280 0.420 0.350 0.350 16 279 19.0 566 0.0 24 64 19.0 0.0 Project Title: Data fi lename: C:\Users\Owner\Documents\REScheck\S1243 CONCORD.Tck Report date: 02110113 Page 1 of 5 315 19.0 0.0 15 SHGC: 0.35 Orientation: Back Basement Wall 4: Solid Concrete or Masonry Orientation: Right Side Wall height:8.0' Depth below grade: 6.5 Insulation depth: 8.0' Furnace 'l: Forced Hot Air 95 AFUE Air Conditioner 1: Electric Central Air .13 SEER compliance statement: The proposed building design described here is consistent with the building plans, specifications, and other i*H:il""::|.T;11y'Tj:: k]::ll,|;ii:l ltyf"::loyloinsl!9 0e91 o".iqryo to meet the 2ooe rEcc requiremenrs inREScheck Version 4 '4.2.3 and to compty witn tne manoatory req;;;#ffi;l; ffi'H;t#ffi'j;ffii"jn."fi,:i: Name - Title Signature Date Project Title: Report date: 02110113 Page 2 of 5 Data fi lename: C:\Users\Owner\Documents\REScheck\S1243 CONCORD.Tck REScheck Software Version 4.4.2.3 lnspection Ghecklist Geilings: E Ceiling 1 : Flat Ceiling or Scissor Truss, R44.0 cavity + R-10.0 continuous insulation Comments: Above-Grade Walls: E Walt 1:Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: E Watt 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: E Watt 3: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: E Watt 4: Wood Frame, 16" o.c., R-21 .0 cavity insulatron Comments: Basement Walls: E Basement wall 1: solid concrete or Masonry, 8.0' ht / 6.5' bg / g.0' insul, R-19.0 cavity insulation Comments: E Basement Wall 2: Solid Concrete or Masonry, 8.0'ht / 6.5' bg / 8.0'insul, R-19.0 cavity insulation Comments: E Basement Wall 3: Solid Concrete or Masonry, 8.0'ht / 6.5' bg / 8.0'insul, R-19.0 cavity insulation Comments: E Basement Wall 4: Solid Concrete or Masonry, 8.0'ht / 6.5' bg / 8.0'insul, R-19.0 cavity insulation Comments: Windows: E Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe fearures: #Panes - Frame Type Thermal Break? - Yes _ No Comments: E Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe fearures: #Panes - Frame Type Thermal Break? - Yes _ No Comments: E Window 3: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes - Frame fype Thermal Break? - Yes _ No Comments: D Window 4: Vinyl Frame:Double Pane with Low-E, U-factor: 0.350 For windows without labeled U-factors. describe features: #Panes - Frame Type Thermal Break? - Yes _ No Comments: Doors: E Door 1: Solid, U-factor: 0.280 Project Title: Data fi lename: C:\Users\Owner\Documents\REScheck\S1243 CONCORD.Tck Report date: 02110113 Page 3 of 5 Comments: D Door 2: Glass, U-factor:0.420 Comments: Heating and Cooling Equipment: E Furnace 1: Forced Hot Air: 95 AFUE or higher Make and Model Number: E Air Conditioner 1: Electric Central Air: 1g SEER or higher Make and Model Number: Air Leakage: tr Joints (including rim joist junctions), attic access openings, penetrations, and all other such openings in the building envelope that aresources of air leakage are sealed with caulk, gasketed, weatherstripped or othenadse sealed with an air banier material, suitable film orsolid material. D Air banier and sealing exists on common walls between dwelling units, on exterior walls behind tubs/showers, and in openings betweenwindow/door jambs and framing. D Recessed lights in the building thermal envelope are 1) type lc rated and ASTM E2g3 labeled and 2) sealed with a gasket or caulkbetween the housing and the interior wall or ceiling covering. tr wood-burning fireplaces have gasketed doors and outdoor combustion air. D Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Air Sealing and Insulation: tr Building envelope air tightness and insulation installation complies by either 1) a post rough-in blower ooor test resurt of less than 7ACH at 50 pascals OR 2) the following items have been satisfied: (a) Air bariers and thermal barrier: Installed on outside of air-permeable insulation and breaks or joints in the air banier are filled orrepaired. (b) ceilins/attic: Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are seated.(c) Above-grade walls: Insulation is installed in substantial contact and continuous alignment with the building envelope air banier.(d) Floors: Air barrier is instailed at any exposed ecrge of insuration. (e) Plumbing and wiring: Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, orsprayed/blown insulation extends behind piping and wiring. (f) corners, headers, nanow framing cavities, and rim joists are insurated (g) shower/tub on exterior wall: Insulation exists between showers/tubs and exterior wall. Materials ldentification and Installation: tr Materials and equipment are installed in accordance with the manufacturer's installation instructions.tr Materials and equipment are identified so that compliance can be determineo. tr Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided.tr Insulation R-values, glazing U-factors, and heating equipment efficiency are clearly marked on the building plans or specifications. Duct Insulation: tr All ducts not compretery inside the buirding enverope are insurated to at reast R_6. Duct Gonstruction and Testing: tr tr Building framing cavities are not used as supply ducts. Alljoints and seams of air ducts, air handlers, filter boxes, and building cavities used as retum ducts are substantially airtight by meansof tapes, mastics, liquid sealants, gasketing or other approved closure systems. Tapes, mastics, and fasteners are rated uL 1g.lA oruL 181 B and are labeled according to the duct construction. Metal duct connections with equipment and/or fittings are mechanicallyfastened' crimp joints for round metal ducts have a contact lap of at least 1 'll2inches and are fastened with a minimum of threeequally spaced sheehmetal screws. Joint and seams covered with spray polyurethane foam. where a partially inaccessible duct connection exists, mechanical fasteners can be equally spaced on the exposed portion of thejoint so as to prevent a hinge effect. continuously welded and locking-type longitudinaljoints and seams on ducts operating at less than 2 in. w.g. (500 pa).tr All ducts and air handlers are located within conditioned space. Temperature Project Title: Data fi lename: c:\Users\owner\Documents\REScheck\s1243 coNCoRD.rck Report date: 02110113 Page 4 of 5 tr At least one programmable thermostat is installed to control the primary heating system and has set-points initialized at 70 degree F for the heating cycle and 78 degree F for the cooling cycle. tr Heat pumps having supplementary electric-resistance heat have controls that prevent supplemental heat operation when the compressor can meet the heating load. Heating and Gooling Equipment Sizing: tr Additional requirements for equipment sizing are included by an inspection for compliance with the International Residential Code. tr For systems serving multiple dwelling units documentation has been submitted demonstrating compliance with 2009 IECC Commercial Building Mechanical and/or Service Water Heating (Sections 503 and 504). Circulating Service Hot Water Systems: tr Circulating service hot water pipes are insulated to R-2. tr Circulating service hot water systems include an automatic or accessible manual switch to turn off the circulating pump when the system is not in use. Heating and Cooling Piping Insulation: tr HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to R-3. Swimming Pools: tr Heated swimming pools have an on/off heater switch. tr Pool heaters operating on natural gas or LPG have an electronic pilot light. tr Timer switches on pool heaters and pumps are present. Exceptions: Where public health standards require continuous pump operation. Where pumps operate within solar- and/or waste-heat-recovery systems. tr Heated swimming pools have a cover on or at the water surface. For pools heated over 90 degrees F (32 degrees C) the cover has a minimum insulation value of R-12. Exceptions: Covers are not required when 60% of the heating energy is from site-recovered energy or solar energy source. Other Requirements: tr Snow- and ice-melting systems with energy supplied from the service to a building shall include automatic controls capable of shutting off the system when a) the pavement temperature is above 50 degrees F, b) no precipitation is falling, and c) the outdoor temperature is above 40 degrees F (a manual shutoff control is also permitted to satisfy requirement'c'). Gertificate: tr A permanent certificate is provided on or in the electrical distribution panel listing the predominant insulation R-values; window U-factors; type and efficiency of space-conditioning and water heating equipment. The certificate does not cover or obstruct the visibility of the circuit directory label, service disconnect label or other required labels. NOTES TO FIELD: (Building Department Use Only) Project Title: Data fi lename: C:\Users\Owner\Documents\REScheck\S1243 CONCORD'rck Report date: O2l1Ol'13 Page 5 of 5 Window Door 0.35 0.3s0.28 0.35 d 2009 IECC Energy LJ.J Efficiency Certificate Floor / Foundation Ductwork (unconditioned spaces) : 54.00 21.00 19.00 Electric Central Air Conditioner Water Heater: Date:Name: -Comments: Load Short Form Entire House KARTCHNER HOMES lD 834442 Phone: 745-8468 Job: S1245 Date: FEBT 2013By: ROBERHALL 197 STOCKMAN BLVD , RIGBY, 5245, KARTCHNER HOMES REXBURGID Htg Glg-6 8970 7576 14-H5503 -31 Infiltration Outside db CF) Inside db ('F) Design TD CF) Daily range Inside humidity (%) Moistu re difference (gr/lb) Method Construction quality Fireplaces Simplified Average 0 HEATING EQUIPMENT Make Int'l Comfort ProductsTrade TempstarModel N9MP2075812.* GAMA ID 70305 Efficiency 90 AFUE Heating input 75000 Heating output 68000 Temperature rise 72 Actual air flow 1020 Air flow factor 0.025 Static pressure 0.70 Space thermostat MAIN BATH Make Trade Cond Coil ARI ref no Efficiency Sensible cooling Latent cooling Totalcooling Actual air flow Air flow factor Static pressure Load sensible heat ratio COOLING EQUIPMENT Infl Comfort Products NAC SERIES NAC224A(G)KC. EP*36P***+*gMP\075 447465 Btuh Btuh OF cfm cfm/Btuh in H2O 13 EER 16800 Btuh 7200 Btuh 24000 Btuh 1020 ctm 0.074 cfm/Btuh 0.70 in H2O 1.00 8145350 Botd llblic values have been manually overridden Printout certified by ACCA to meet all requirements of Manualgth Ed. ROOM NAME Area (fF) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) BED 1 BED2 BASE BATH BED3 UTILITYI\4ECH GREAT ROM TOY ROOM LAUNDRY MUD ROOM POWDER LIVING FAMILY MASTER BED MASTER BATH KICTHENDINING 168 256 80 170 313 928 66 60 48 42 99 502 276 187 420 2015 1618 678 2182 1 558 61 10 1 036 1282 563 587 2286 3543 2750 2810 5288 646 634 12 965 23 857 21 175 90 90 1542 1 358 1 586 849 1171 51 41 17 55 39 155 26 32 14 15 58 90 70 71 134 48 47 1 71 2 63 2 13 7 7 114 100 117 63 86 4* *rripf*tssft- Right -Suite@ U niv ers al 7. 1.03 RSU 06972 C:\Documents and Settings \ROBERT HALL \My Documents \Vwightsoft HVAC \CONCORD CR 383.rup Catc = MJB 2013-Feb-10 20:19:18 Page 1 BED4 183 14005 1020 102046000 BED5 166 2500 2989 1850 1 890 63 76 136 139 Entire House d Other equip loads Equip. @ 0.94 RSM Latent cooling 4014 40249 5751 1 3839 1 059 14005 0 1020 1020 TOTALS I +OI+ Bold /italic vatues have been manuaily overridden Printout certified by ACCA to meet ail requirements of Manualgth Ed. +$- unright*s,ft- Right -suite@ U niv ers al 7. 1.03 RSU 06972 2013-Feb-10 20:19:18 Page 2 c:\Documents and settings \RoBERT HALL \My Documents \wrightsoft HVAC \coNcoRD cR 3B3.rup carc = MJ8 197 STOCKMAN BLVD , RIGBY, Building Analysis Entire House KARTCHNER HOMES D 8U442 Phone: 745-8468 Job: Date: By: st245 FEBT 2013 ROBER HALL SI245. KARTCHNER HOMES REXBURGID Location: ldaho Falls,lD, USElevation 4741 ftLatitude: 44'N Outdoor: Dry bulb("F) Daily range ('F) Wet bulb('F) Wind speed (mph) Heating -6 Gooling 8934 (H )60 7.5 Indoor: Indoor temperature ("F) Design TD fF)Relative humidity(%) Moi sture difference(gr/l b) lnfiltration: Method Construction quality Fireplaces xeati;9 76 5 2.6 Simplified Average 0 Gooling 75 14 50 -31.5 15.0 Component Btuffi Btuh % of load Walls Glazing Doors Ceilings Floors Infiltration Ducts Piping Humidification Ventilation Adjustments Total 5.2 26.6 13.3 1.7 1.8 3.0 17473 6889 1117 3399 3750 7620 0 0 0 5751 0 46000 38.0 15.0 2.4 7.4 8.2 16.6 0 0 0 12.5 100.0 Comoonent Btuh/ff Btuh % of load Walls Glazing Doors Ceilings Floors lnfiltration Ducts Ventilation Internalgains Blower Adjustments Total 0.4 30.4 3.2 0.9 0.0 0.3 1222 7884 272 1878 81 752 0 1 059 1750 0 0 14899 8.2 52.9 1.8 12.6 0.5 5.0 0 7.1 11.7 0 100.0 Overall Uvalue = 0.055 BtuhlfF-'F Data entries checked. aF{*F ur3,lgrr?rBs,fr* Right -suite@ u nivers al 7. 1.03 RSU 06972 C:\Documents and Settings \ROBERT HALL \My Documents \Wrightsoft HVAC \CONCORD CR 383.rup Calc = MJ8 2013-Feb-10 20:19:18 Page 1 Gomponent Gonstructions Entire House KARTCHNER HOMES Job: Date: By: st245 FEBT 2013 ROBER HALL 197 STOCKMAN BLVD , RIGBY , lD 834442 Phone: 745-8468 For: S1245, KARTCHNER HOMES REXBURGID Location: ldaho Falls,lD, USElevation 4741 ftLatitude: 44'N Outdoor: Dry bulb("F) Daily range ("F) Wet bulb('F) Wind speed (mph) Cooling 8934 (H )60 7.5 Indoor: I ndoor temperature ('F) Design TD fF)Relative humidity(%) Moistu re difference (gr/b) Infiltration: Method Construction quality Fireplaces Heating I 15.0 Heating 70 76 5 2.6 Simplified Average 0 Cooling 75 14 50 -31.5 Gonstruction descri ptions Walls 12E-0sw : Frm wall, vnl ext,3/8"wood shth , r-19 cav ins, 1/2" gypsum board int fnsh , 2"x6" wood frm 15815-0wc -6: Bg wall , light dry soil, 2"x4" wood int frm , concrete wall, r-15 cav ins, 10" thk, 1/2" gypsum board int fnsh Partitions (none) Windovra 61C: VINYL .35 U - VALUE; NFRC rated (SHGG0.35) Doorc 71A: GLASS .35 - U VALUE 11D0:11D0 Geilings 16B-44ad: Attic ceiling, asphalt shingles roof mat , r-44 cnilins,1l2" gypsum board int fnsh Floors 19A-0bswp : Partfloor, hrd wd flrfnsh , frm flr, 12" thkns, 1/2" gypsum board int fnsh 214-28c: Bg floor , light dry soil, carpet flr fnsh Htg HTM Loss Clg HTM GainBtuhlP Btuh Btulvff Btuh Or Area ff ne 499se 387sw 498nw 387all 1771ne 566se 315sw 461nw 279all 1621 llvalue lnsul RBtubfrrF ffrFBtuh 0.068 19.00.068 19.00.068 19.00.068 19.00.068 19.00.061 15.00.061 15.00.061 15.00.061 15.00.061 15.0 5.17 5.17 5.17 5.17 5.17 5.04 5.2'l 5.15 5.21 5.13 2579 0.64 3192000 0.64 2472574 0.64 3182000 0.64 2479'153 0.64 11322852 0.04 251640 0.06 202376 0.06 271452 0.06 188320 0.06 90 ne 89ne 64sw 90sw 16all 259 2033 52 1 981 0.350 0.350 0.350 0.350 0.350 0.022 0.295 0.022 44.0 0 0 26.6 zo.o 26.6 26.6 26.6 26.6 0 1.67 8.42 1.67 0 0 0 0 0 2367 26.2 23281702 26.2 16742394 33.2 2992426 33.2 5326889 29j 7525 1117 6.47 272000 3399 0.92 1878 438 1.55 3312 0 ne 42 0.350 0sw4200 81 4d* rrrrrlghti*r:'ft* Right -suite@ u niversal 7. 1.03 RSU 06972 C:\Documents and Settings \ROBERT HALL \My Documents \Wrightsoft HVAC \CONCORD CR 3B3.rup Catc = MJ8 2013-Feb-10 20:19:19 Page 1 *l$ts vrrrtght*{rft" Right -Suite@ U niv ers al 7. 1.03 RSU 06972 C:\Documents and Setlings \ROBERT HALL \My Documents \Wrightsoft HVAC \CONCORD CR 3B3.rup Calc = MJB 2013-Feb-10 20:19:19 page 2 197 STOCKMAN BLVD , RIGBY Project Summary Entire House KARTGHNER HOMES lD 834442 Phone: 745-8468 Job: Date: By: st245 FEAT 2013 ROBER HALL Notes: SI245, KARTCHNER HOMES REXBURqtD HOME FACES SOUTH WEST Weather Winter Design Conditions Heating Summary ldaho Falls,lD, US Summer Design Conditions Outside db Inside db Design TD Structure Ducts Centralvent(82 cfm) Humidification Piping Equipment load Infiltration Method Construction quality Frreptaces Outside db Inside db Design TD Daily range Relative humiditv Moisture differedce -6 'F70 0F 76 0F 89 0F 75 'F14 0F H50 o/o -31 gr/lb 13839 Btuh0 Btuh1059 Btuh0 Btuh Sensible Gooling Equipment Load Sizing Area(fF) Volume (ff) Air changes/hour Equiv. AVF(cfm) Heatino 401tr 23250 0.28 108 40249 0 5751 0 0 46000 Btuh Btuh Btuh Btuh Btuh Btuh Simplified Average 0 Gooling 4014 23250 0.15 58 Structure Ducts Centralvent(82 cfm) Blower Use manufacture/s data Rate/swinq multiplier Equipmenl sensible load Structure Ducts Centralvent(82 cfm) Equipment latent load Equipment total load Req. total capacity at0.70 SHR Make Int'l Comfort ProductsTrade NAC SERTESQond NAC224A{G)KC.coil EP*36F**i*i.gMP\075 ARI ref no 447465 Efficiencv Sensible'cooling Latent coolinqTotalcooling- Actual air flow Air flow factor Static pressure Load sensible heat ratio Latent Cooling Equipment Load Sizing n 0.9414005 Btuh 495 Btuh0 Btuh -1472 Btuh0 Btuh 14005 Btuh1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Int'l Comfort ProductsTrade TempstarModel N9MP2075B12** GAMA ID 70305 Efficiency Heating input Heating output remperature nse Actual air flow Air flow factor Static pressure Space thermostat 90 AFUE75000 Btuh 68000 Btuh72 0F 1020 cfm0.025 cfm/Btuh0.70 in H2O 13 EER 16800 Btuh7200 Btuh 24000 Btuh 1020 cfm 0.074 cfm/Btuh0.70 in H2O 1.00 Bold litatic values have been manually overridden Printout certified by ACCA to meet all requirements of Manualsth Ed. 4J- rarrf*frtr.ift* Right -Suite@ U niv ers al 7.1.03 RSU 06972 c:\Documents and settings \RoBERT HALL \My Documents \wrightsoft HVAC \coNcoRD cR 383.rup catc = MJ8 2013-Feb-10 20:19:19 Page 1 Right-.J@ Worksheet Entire House KARTCHNER HOMES Job: S1245 Date: FEBT 2013By: ROBERHALL 197 STOCKMAN BLVD , RTGBY , tD 994442 phone: 245-8468 ,| e 4 Room name Exposed wall Ceiling height Room dimensions Room area Entire House 415.0 ft9.0 4014.O ft o ll2 BED 1 26.0 ft9.0 ft heat/cool'12.O x 14.0 ft168.0 ft, Ty Construction number U-value(Btuh/ft'rF Or HTM (Btuh /ft 'z) Area (ft,)or perimeter (ft ) Load (Btuh)Area (ft1or perimeter (ft ) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 11 Wl-Gl-D WrG W W F--Gr--D W '-----GW c T 12EOsw 61C 71A 15815owc-6 6'1C 12EOsw 158'15{wc-6 12E{sw 61C 11D0 15815owc-6 6'1C 12E{sw 15815{wc-6 168:44ad 194-0bswp 21Aaac 0.068 r0.350 0.3s0 0.088 0.068 0.088 0.068 0,350 0.000 0.088 0.068 0.088 0.022 0.295 0.022 ne ne ne ne se se sw sw sw sw sw nw nw s. 17 | 0.64 26.60 | 26.1!26.601 6.4i s.ol I o.o4 26.60 | 26.18s.rzl o.ots.21|. 0.0€ s. rz | 0.64 ze.oo | 3s.240.001 0.00s.1sl 0.06 26.60 | 33.24s.rt | 0.64 5 21 | 0,06 1.67 | 0.928.421 1.55 1.67 | 0.00 630eo 42 630 64 387al< 630 90.42 477 16 387 279 2033 52 198'l 499 42 coo 0 J6' 315 498 n 42 461 0 J5/ 2033 cz 1981 2575 236i 111i 2852 't702 200c 1 64C 2574 2394 237e, 426 2000 1452 3399 438 3312 319 2328 272 25 1674 247 20 318 ZJJZ 27 532 247 18 1878 81 0 108 16 126 0 0 0 0 0 0 0 0 168 .0 u 0 YZ 0 o tzo 0 0 0 0 0 0 0 0 0 168 .0 o 455 426 0 oco 0 0 0 0 0 0 0 0 0 281 U n 0 418 0 R 0 0 0 0 0 0 0 0 0 0 o c) AED excursion 360 Envelope loss /gain 32629 11337 1818 ?74 l2 a) Infiltrationb) Room ventilation 7620 n 752 198 0 20 0 1?Intemal gains : Occupants @ 2SO Appliances @ 1800 1750 U 1 250 0 Subtotal (lines 6 to 13)40249 13839 2015 646 14 IR Less external load Less lransfer Redistribution Sublotal Ducl loads o%Oo/o 40249 0 0I eeeo 0 Oo/r Oo/l 0 0 0 2015 0 0 0 0 646 0 Total room load Ahrequired (cfm ) 40249 1020 1 3839 1020 2015EI 646 48 2013-Feb -,l0 20:19:19ffi c:\Documents and settings \RoBERT HALL \My Documents \Vwightsoft HVAC \coNcoRD cR 383.rup catc = MJ8 page 1 Right-J@ Worksheet Entire House KARTCHNER HOMES Printout certified bv ACCA to meet all reouirements of ManualSth Ed. Job: 51245 Date: FEBT 2013 By: ROBERHALL 197 STOCKMAN BLVD . RIGBY , lD 834442 Phone: 745-8468 1 2 3 4 Room name Exposed wall Ceiling height Room dimensions Room area 6CU Z 16.0 n 9.0 ft heat/cool16.0 x 16.0 ft 256.0 ft' BASE BATH 10.0 ft 9.0 ft heat/cool8.0 x '10.0 ft 80.0 fi, Ty Construclion number U-value (Btuh /ft'zrF) Or HTM (Btuh /ft'z) Area (ft1or perimeter (ft ) Load (Btuh) Area (ft')or perimeter (ft ) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NiP/S Heat Cool 1'l W l----€rD WlG W Wl-GlD WlG W Wc T F. 12Eosw 61C 71A 15815OwG6 61C 12E{sw 15815{wc-6 12E{sw 61C'11D0 15815Owc-6 61C 12E{sw 15815{wc-6 158-44ad 19A-0bswp 21A-28i 0.068 0,350 0.350 0.088n a6n 0.068 0.088 0.068 0.350 0.000 0.088 0.350 0.068 0.088 o.o22 0.295 0.a22 se se sw sw sw sw sw nw nw 5.17 26.60 26.60 5.04 26.60 s.i7 5.21 s.17 26.60 0.00 5.15 26.60qla 5.21 1.67 8.42 1.67 0.64 26.15 6.47 0.04 26.15 i0.64 0.06 :0.64 33.24 0.0c 0.0€ 33.24 0.64 0.0€ 0.92 1.55 0,0c 0 '144 1A 0n 0 o U n n 0 n 0 0 256 r0 0 0 128 0 o 0 o o 0 0 0 0 0 0 0 zco 643 426 428 418 9C 8( 0 0 0 0 0 U 469 0 0 0 0 0 0 0 0 0 134 0 0 0 0 0 0 6 0 0 0 0 0 0I 0 0 0 c) AED excursion -52 Envelope loss /gain 1496 372 ouz D 12 a) Infiltrationb) Roomventilation 122 L t aa 0 d 0 1a lntemal gains : Occupants @ 250 Appliances @ 1800 1 250 U 0 0 Subtotal (lines 6 to 13)1618 634 678 12 14 4R Less extemal load Less lransfer Redistribution Subtolal Duci loads Oo/'Oo/. 0 0 0 161 8 0 n n 634 n ool Oo/' 0 0 0 678 0 0 0 0 12 Total room load Air required (cfm ) 1 618 4'l 634 47 b/6 17 ,| ,**" ^}{{- wFtffrltsre.rk. Right-Suite@ Universal7.1.O3 RSU 06972r(CGr C:\Do"rments and Settings \ROBERT HALL \My Documents Wvrightsoft HVAC \CONCORD CR 383.rup Calc = MJB 2013-Feb-10 20:19:19 Page 2 Right-J@ Worksheet Entire House KARTCHNER HOMES Printnr rl nertified hv ACCA tn meei all reorrirements of Manual 8th Ed. Job: Date: By: st245 FEBT 2013 ROBER HALL 197 STOCKMAN BLVD . RIGBY . lO 834442 Phone: 745-8468 1 z J 4 5 Room name Exposed wall Ceiling height Room dimensions Room area BED 3 29.0 fr9.0 ft heat/cool'1.0 x 170.0 ft 170.0 ft, UTILITY /MECH 19.0 ft 9.0 fi heat/cool1.0 x 313.0 ft 313.0 ft, Ty Conslruction number U-value (Btuh /fi1'F)Or HTM (Btuh /ft') Area (ft 1or perimeter (ft ) Load (Btuh) Area (ft 1or perimeter (ft ) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 W -GL-----D Wlc W Wl.--€tiD WlG W Wc r F 12E{sw 61C7iA 1581s{wc-o 61C 12E{sw 15Blm\rvc-o 12E{sw 61C 11DO 'l58150wc-6 61C 12EOsw 158150wc-6 168-44ad 1 gA-obswp 21A-2ac 0.068 0.350 0.350 0.088 0.350 0.068 0.088 0.068 0.350 0.000 0.088 0.350 0.068 0.088 0.022 0.295 0.022 ne ne ne ne se se sw sw sw sw sw nw nw s.i7 26,60 26.60 5.04 zo.ou 5.17 5.21 5,17 26.60 0.00 5.15 26.60 5.17 5.21 1.67 8.42 1.67 0.64 26.1 5 6.:47 0.04 26.15 0.64 0.06 0.44 33.24 o.oo 0.06 33.24 0.64 0.06 U.JZ 1.55 0.00 0n 0 n 0n 144 16 0 18 0 0 170 0 0 0 0 0 o 99 0 o 0 128 0 0 18 0 0 170 0 0 0 0 0 0RIE 0 0 0 643 426 0 94 0 0 284 0 0 0 0 0 0 o o 0 5 532 1 o 0:0 0 0 0 0 0 0 0 0 108 0 0 OJ 0 0 313 ol 0l ol 3l il 0l ^l"ll '31 .,31 I I I I I I I I 0 0 0 0 0 0 0 0 0ii0 562 0 0 328 0 0 czJ 0 0 0 0 0 0 0 0 o 0 0 4 0 0 o c) AED excursion 149 Envelope loss /gain 1962 694 14't4 tz a) Infillralionb) Room ventilation 220 c 144 0 14 0 4?lntemal gains : Occupants @ 25O Appliances @ 1800 0 250 c 0 0 Subtotal (lines 6 to 13)2182 965 1 558 23 14 1E Less extemal load Less transfer Redistribution Subtotal Ducl loads Oo/o Oo/l 2182 0 0 0 voc ool Oo/l 0 0 0 1558 0 0 0 0 ZJ 0 Total room load Air required (cfm ) 2182 D' 965 71 1558 23 ihtr "{*F wrt$lit'Fsr{Fk- Right-Suite@ Universal7.1.03 RSU06972#* C,\Documents and Settings \ROBERT HALL \My Documents \Wrightsofl HVAC \CONCORD CR 383.rup Calc = MJ8 20'13-Feb-10 20:19:19 Page 3 Right-.J@ Worksheet Entire House KARTCHNER HOMES Printout certified bv ACCA to meet all reouiremenis of ManualSth Ed Job: S1245 Date: FEBT 2013By: ROBERHALL 197 STOCKMAN BLVD , RIGBY , lD 834442 Phone: 745-8468 1 2? 4 5 Room name Exposed wall Ceiling height Room dimensions Room area GREAT ROM 72.0 tl9.0 ft heat/cool1.0 x 928.0 ft 928.0 ft, TOY ROOM,17.o tl 9.0 ft heat/cool11.0 x 6.0 fi66.0 fr Ty Construction numDer U-value (Btuh /ft'?-'F) Or HTM (Btuh /ft'?) Area (n 1or perimeter (ft ) Load (Btuh) Area (ft')or perimeter (ft ) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool o Wt^r-D W W Wl----clD WlG W F F 12EOsw6'tc 71A 15815{wc-6 61C 12E{sw 15B15owc-6 12E{sw otu 11D0 15815Owc-6 61C 12E€sw 15815owc-6 168-44ad 1gA-obswp 21A28c 0.068 U.JCU 0.350 0.088 0.350 0.068 0.088 0.068 0.359 0.000 0.088 0.350 0.068 0.088 o.o22 u. zua 0.022 ne se se sw sw 9W sw sw nw nw 5.17 26.60 26.60 5.04 zo.ou E 4a 5.21 5.17 26.60 0.00 5.15 26.60<47 5.21 1.87 8.42 1.67 0.64 26.11 6.47 0.04 26.18 0.64 0.0€ 0.64 33.24 0.0c 0.0€ 33.24 0.64 0.06 1.55 0.00 0 0 0 378 32 0 0 0 0 0 126 0 0 144 o 0 YZa 346 0 0 0 o 0 126 0 0 144 0 0 928 1794qEl n 0 /cu ! 1552 'li 837 0 0 0 0 0 0 0 0 0 0 99 0 0 54 0 0 0 0 0 0 0 0 0 0 o 0 99 0 0 54 0 0 0 0 0 0 0 0 0 0 0 0ta t 0 0 281 0 0 110 0 0 0 0 0 0 0 0 o 0 o 0 0 0 0 0 c) AED excursion -or Envelope loss /gain ccoz AN?907 I 12 a) Infiltrationb) Room ventilalion 547 c 54 0 129 0 13 l?lntemal gains : Occupants @ 250 Appliances @ 1800 0 0 Subtotal (lines 6 to 13)61 10 1 036 2'l 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads Oo/o ool 61 10 0 0 0447 0 Oo/t ool 0 0 0 1036 0 0 0 0 21 0 Total room load Airrequired (cfm ) 61 10IEE aR7 OJ 1036 zo 21 2 &! *ld wFrglrtrefr,- Right-Suite@ Universal7.1.O3 RSU06972fiR C:\DocumentsandSettings \ROBERTHALL \MyDocuments \WrightsoftHVAC \CONCORDCR 3B3.rup Calc =MJ8 2013-Feb-10 20:19:19 Page 4 !'i{'^rr\ C:\Documents and Settings \ROBERT HALL \My Documents \Vwightsoft HVAC \CoNCORD cR 383.rup Catc = MJ8 page o