HomeMy WebLinkAboutALL DOCS & CO - 08-00199 - The Meadows - Phase 3 - Bldg 6, 4 Units0 0
C j V Q F Certificate of Occupancy
` City of Rexburg
""
Ari2ericcA Family Comm till it>> Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone 208 359 -3020 / Fax 208 359 -3024
Building Permit No: 0800199
Applicable Edition of Code: International Building Code 2006
Site Address: 505 Countryside Ave
Use and Occupancy: The Meadows Townhomes
Type of Construction: Type V, non -rated
Design Occupant Load: N/A
Sprinkler System Required: No
Name and Address of Owner: Meadows Phase 4
1375 S Blackhawk Blvd
Mt Pleasant, UT 84647
Contractor: Timberhawk Inc
Special Conditions:
Occupancy: Residential - 2 units or less, permanent in nature
This Certificate, issued pursuant to the requirements of Section 909 of the International Building
Code, certifies that, at the time time of issuance, this building or that portion of the building that
was inspected on the date listed was found to be in compliance with the requirements of the
code for the group and division of occupancy and the use for which the proposed occupancy
was classified.
Date C.O. Issued: July 29 2010 (01:11
C.O Issued by:
Building Official
There shall be no further change in the existing occupancy classification of the building nor shall any structural changes,
modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and
approved said future changes.
Plumbing Inspector: ; Fire Inspector: —
Electrical Inspector: P &Z Administrator
xl3t" Ci1'Y OF Certificate of Occupancy
i�
v, a REXBU G City of Rexburg
Department of Community Development
Arile? ial" Eolnily conirxu it3
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359 -3020 / Fax (208) 359 -3024
Building Permit No:
Applicable Edition of Code:
Site Address:
Use and Occupancy:
Type of Construction:
Design Occupant Load:
Sprinkler System Required:
International Building Code 2006
507 Countryside Ave
The Meadows Townhomes
Type V, non -rated
N/A
No
Name and Address of Owner: Meadows Phase 4
1375 S Blackhawk Blvd
Mt Pleasant, UT 84647
Contractor: Timberhawk Inc
Special Conditions:
Occupancy: Residential - 2 units or less, permanent in nature
This Certificate, issued pursuant to the requirements of Section 109 of the International Building
Code, certifies that, at the time time of issuance, this building or that portion of the building that
was inspected on the date listed was found to be in compliance with the requirements of the
code for the group and division of occupancy and the use for which the proposed occupancy
was classified.
Date C.O. Issued: July 29 20 (01:1
C.O Issued by:
Building Official
There shall be no further change in the existing occupancy classification of the building nor shall any structural changes,
modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and
approved said future changes.
1 � Plumbing Inspector: Fire Inspector:
Electrical Inspector: P&Z Administrator
Certificate of Occupancy
kk XB
CIT }' O p
po i c
URG City of Rexburg
r,; Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359 -3020 / Fax (2081359 -3024
Building Permit No: 0800199
Applicable Edition of Code: International Building Code 2006
Site Address: 501 Countryside Ave
Use and Occupancy: The Meadows Townhomes
Type of Construction: Type V, non -rated
Design Occupant Load: N/A
Sprinkler System Required: No
Name and Address of Owner: Meadows Phase 4
1375 S Blackhawk Blvd
Mt Pleasant, UT 84647
Contractor: Timberhawk Inc
Special Conditions:
Occupancy: Residential - 2 units or less, permanent in nature
This Certificate, issued pursuant to the requirements of Section 109 of the International Building
Code, certifies that, at the time time of issuance, this building or that portion of the building that
was inspected on the date listed was found to be in compliance with the requirements of the
code for the group and division of occupancy and the use for which the proposed occupancy
was classified.
Date C.O. Issued:
C.O Issued by.
April 01, 201 0:-
MEW
Building Official
There shall be no further change in the existing occupancy classification of the building nor shall any structural changes,
modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and
approved said future changes.
Plumbing Inspector- '�) eR��_� r� «- .° . _ Fire Inspector:
F
Electrical Inspector: P&Z Administrator - -- I
P.O Box 280
OF gEXBUpC
CITY OF 19 E. Main St.
REXBURG City of Rexb u rg Rexburg, Idaho 83440
---- "V — .._..__.--- Phone (208) 359 -3020
Amerkak Family Community
STATE OF IDAHO Fax (208) 359 -3022
e-Mail
April 23, 2008
REQUEST FOR A CONDITIONAL BUILDING PERMIT
FOR PARTIAL BUILDING CONSTRUCTION
TO: Building Official for the City of Rexburg
Pursuant to the provisions of the International Building Code 2000, the undersigned requests that
a building permit be issued for:
Footings and Foundations only at:
501 -507 Countryside Ave 616 �
Rexburg,
Acknowledgment is made that the plans for the complex are not complete and that final approval
of the building will not be given until the final plans have been approved. We recognize that
proceeding with partial construction at this time is entirely at the risk of the Architect/Owner
with there being no assurance that the final Certificate of Occupancy for the entire building or
structure will be granted.
We further absolve the City of Rexburg and officers and employees thereof, of all resposibility
for the issuance of a partial permit and further agree that any work performed under this permit
will be removed or otherwise corrected to be in accord with the requirements of the fi
approved plans when a permit for the entire building of structure is finallyAred. c;.
Dated: Wednesday April 23 2008 By
Approved: Wednesday April 232008
C Dra Mit F REXBURG
Y
ell Hansen
Coordinator /Tech
Please com pl ete th e Apphc atian ! If the question d ; t apply fill in NA for non
applicable "
NAME , ::S 1 'Y_
PROPERTY ADDRESS
SUBDIVISION
0800199
"1110 \le;adows Please 3
501, 503, 505, 507
RegiriredN ELECTRICAL
Electrical Contractor's Name NC-Ni 1 �€�,`� Business Name
vZ7 n Opp
Address t ��[-' 2 City fz2,X � �_y' � State -�-' j Zip 8 3 LI P
Cell Phone 11 a '&P) 3 Business (2, 6$)
Fax (zPj) 3 5 � - S9 b (4 Email
Electrical Estimate ( cost of wiring & labor) $ - 1 U00 (Commercial /Multi Family Only)
TYPES OFINSTALLATION- RESIDENTL4L
(New Residentralincludes everything contained within the residential structure and attachedgarage at the same time)
— Up to 200 amp Service* - - -
201 to 400 amp Service*
Over 400 amp Service*
Existing Residential (# of Branch Circuits)
l Q4t � Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 year)
Spa, Hot Tub, S wimmin g Pool
Electric Central Systems Heating and /or Cooling ( when not part of a new residential construction permit
and no additional wiring)
Modular, Manufactured or Mobile Home
Other Installations: Wiring not specifically covered by any of the above
Cost of Wiring & Labor:
Pumps (Domestic Water, Irrigation, Sewage)
Requested Inspections (of existing wiring)
Temporary Amusement /Industry
*Includes a maximum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour.
Signature of Li sed Contractor License number Date
The City of Bexburg'spermit fee schedule is the same ar required by the State of Idaho
6
r C17Y OF REYBUAG 0800199
ows Ph 3
1e I��loadase -
BUILDING PERMIT APPLICATION Please t 1l ie ad 505, a
19 E MAIN, REXBURG, ID. 83440 If the ques
208 - 359 - 3020 X326
PARCEL NUMBER: W M Q s �?�� M Nt 1J (We will provide this for you) ,
SUBDIVISION: -we l w v UNIT # --QJ LOCK# LOT
is based on the lntormation - must be
PROPERTY ADDRESS:
CONTACT PHONE # 2- - 3 9lr
PHONE #: Home (qJ5) 7 b ' E I 1 Y Work (q 3�) Jq P ' b 2 q Cell ( )
OWNER MAILING ADDRESS: 1 5 &4 .95; N. CITY: a STATE: TA ZIP: d 344 2-
EMAIL F
APPLICANT (If other than owner)
(Applicant if other than owner, a statement authorizing applicant to act as agent for owner must accompany this application.)
APPLICANT INFORMATION: ADDRESS 'P• D+ '6 b6S CITY: e-r
STATE; l -- ZIP EMAIL C rid(?- t ,' '7O .- (g44
PHONE #: Home (q3S) Work (m) 796 - Cell (q33) `7
CONTRACTOR 20 4 &,O
MAILING ADDRESS: CITY STATE ZIP
PHONE: Home# Work# Cell# Fax#
EMAIL IDAHO REGISTRATION # & EXPIRATION DATE
How litany buildings are located on this property? Gv r,r2 `7 fwevA - -
Did you recently purchase this property? No es 011F yes give owner's name)
Is this a lot split? 0 YES (Please bring of new legal description of property)
PROPOSED USE: Gk kA
(i.e., Single Family Residence, Multi Family, Apartments, R4nodel, Garage, Commercial, Addition, Etc.)
APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: under penalt of perjur I hereb certify that I
have read this application and state that the information herein is correct and I swear that aarJy information which may hereafter be given by me in hearings before the
Planning and Zoning Commission or the 9ty Council for the City of Rexburg shall be truthful and correct I agree to comply with' all City regulations and State laws relating
to the subject matter of this application hereby authorized representatives of the Cio enter upon the above - mentioned property for inspections purposes. NOTE:
The building official may revoke a penni on approval issued under p ovisions of th 2003 International Code in cases of any false statement or misrepresentation of fact
in the appli tion or on the plans on whi the permit or approval ed. Permit v id if not startelwithin 180 days. Permit void if work stops for 180 days.
Signature of Owner / Applican D (E
Do you prefer to be con' cted by fax, email or phone? Circle One Lis
WARNING — BUILDING PERMIT MUST BE POSTED ON CONS ION SITE!
Plan fees are non - refundable and are paid in full at the time of application b �� WQ!
City of Rexburg's Acceptance of the plan review fee does not consti to pla approval
*Building Permit Fees are due at time of application'* '*Building Permits are v d if y check does not clear**
CITY OF REXBC
RC 2
Please complete the• tire A p p lication!
•
p pP
If the question does not apply fill in NA for non applicable
NAME
PROPERTY ADDRESS Permit#
SUBDIVISION [ yj,. . Pm- C-Pcpow S
Dwelling Units: Parcel Acres: e a ) (a
SETBACKS SF- e S Sc < 6AC e-S
FRONT SIDE SIDE BACK
Remodeling Your Buildrig /Home (need Estimate $
SURFACE SQUARE FOOTAGE: (Shall include the exterior wall measurements of the building)
First Floor Area Unfinished Basement area No "e
Second floor /lo area Finished basement area
Third floor /loft area Garage area
Shed or Barn Carport /Deck (30" above grade)Area -
Water Meter Quantity: —
* * * * * * * * * * * ** *Water Meter Size:
Required.!!
PLUMBING n
Plumbing Contractor's Name: X`L'6 H ! Lt. Business Name: c S r(. y,gIoz, g, H I f
Address 7 3 y D L w PEA City fns c. State 4 o Zip 06 � �
Contact Phone: (2p r) 99 j - X 1 71 - 5 Business Phone: (tad 3 3 ($
Email Fax
FIXT COUNT (includingroughed fixtures,
Clothes Washing Machine Sprinklers
Dishwasher y Tub /Showers
L Floor Drain Toilet /Urinal
7
Garbage -Disposal Water Heater
Hot Tub /Spa `T Water Softener
Sinks (Lavatories, kitchens, bar, mop)
Plumbing Estimate $,
(Commercial Only)
S attire of sed Contractor License Number& Expiration Date Date
The City of Kexburg's permit fee schedule is the same as required by the State of Idaho
4
Please complete the entire Application! If the question does not apply fill in NA for non
applicable
NAME
PROPERTY ADDRESS
SUBDIVISION
Permit#
Required f MECHANICAL
Mechanical Contractor's Name: Y H Business Name: tit LA'S 91LV F(fd (.
Address 3 6 _ City .1 ata�x�� s State -� Zip
Contact Phone: (2 oe) 5;Z1 - 73 /S Business Phone: (Z> I - ' 15-
Mechanical Estimate $ (Commercial /Multi Family Only)
FIXTURES & APPLIANCES COUNT (Single Family Dwelling Only)
Furnace Exhaust or Vent Ducts
Y Furnace /Air Conditioner Combo - Dryer Vents
Heat Pump
Air Conditioner
Evaporative Cooler
Unit Heater
Space Heater
Decorative gas -fired appliance
Incinerator System
Boiler
Pool Heater
Range Hood Vents
Cook Stove Vents
Bath Fin Vents
other similar vents & ducts:
Fuel Gas Pipe Outlets including stubbed in or future outlets
I nlet Pressure (Meter Supply) PSI
Heat (Circle all that apply) as it Coal Fireplace Electric Hydronic
Mechanical Sizing Calculations must be submitted with Plans & Application
Point of Delivery must be shown on plans.
A
Signa e of Licen ' d Contractor License number Date
The City of Rexburz's permit fee schedule is the .came as required by the State
5
Certificate of Occupancy
C i f Y O F
s
_ REX13 City of Rexburg
America's Fnn2il Cwnnn.mit
` y Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone 208 359 -3020 / Fax 208 359 -3024
Building Permit No: 0800199
Applicable Edition of Code: International Building Code 2006
Site Address: 503 Countryside Ave
Use and Occupancy: The Meadows Townhomes
Type of Construction: Type V, non -rated
Design Occupant Load: N/A
Sprinkler System Required: No
Name and Address of Owner: Meadows Phase 4
1375 S Blackhawk Blvd
Mt Pleasant, UT 84647
Contractor: Timberhawk Inc
Special Conditions:
Occupancy: Residential - 2 units or less, permanent in nature
This Certificate, issued pursuant to the requirements of Section 109 of the International Building
Code, certifies that, at the time time of issuance, this building or that portion of the building that
was inspected on the date listed was found to be in compliance with the requirements of the
code for the group and division of occupancy and the use for which the proposed occupancy
was classified.
Date C.O. Issued: July 29, 2010 01:13PM
C.O Issued by:
Building Official
There shall be no further change in the existing occupancy classification of the building nor shall any structural changes,
modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and
approved said future changes.
Plumbing Inspecto�* Va-�' Fire Inspector:
Electrical Inspector: P8Z Administrator
Project Title: The Meadows Townhomes
Report Date: 03 /28/07
Data filename: C: \Documents and Settings \Chris Jaussi \My Documents \PROJECTS \REXBURG MEADOWS \New Townhome Res
Check. rck
The Meadows Townhomes
Page 1 of 4
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R -5. Ducts outside the building must be insulated to R -8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus- embedded - fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each dwelling unit (non - dwelling areas must have one thermostat for each system or zone). A
manual or automatic means to partially restrict or shut off the heating and /or cooling input to each room shall be provided.
Electric Systems:
❑ Separate electric meters are required for each dwelling unit.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on /off heater switch and require a cover unless over 20% of the heating energy is from
non - depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
The Meadows Townhomes
a :P
Page 3 of 4