Loading...
HomeMy WebLinkAboutAPPLICATIONS, CO, MULT DOCS - 07-00033 - 512 S Millhollow Rd - AdditionO�gEXBUgG, 10 CITY o 1: Certificate of Occupancy REX13UG City of Rexburg ` America's Fam y Community Department of Community Development Fam 19 E. Main St. / Rexburg, ID. 83440 Phone (2081 359 -3020 / Fax (2081359 -3024 Building Permit No: 0700033 Applicable Edition of Code: International Residential Code 2003 Site Address: 512 S Millhollow Rd Use and Occupancy: Residential Addition Type of Construction: Type V, non -rated Design Occupant Load: Single Family Residence Sprinkler System Required: No Name and Address of Owner: Smith Rob & Sally 512 S Millhollow Rd Rexburg, ID 83440 Contractor: Md Builders Special Conditions: Sidewalks must be in place by Sept 30, 2009 Occupancy: Residential - less than 2 units, permanent in nature This Certificate, issued pursuant to the requirements of Section 909 of the International Building Code, certifies that, at the time time of issuance, this building or that portion of the building that saes inspected on the date listed vies found to be in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancy ms classified. Date C.O. Issued: January 228 (03:22PM) C.O Issued by: rsuuamg L mciai There shall be no further change in the,e)asting occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. Plumbing Inspecto - jj '3" ___" � A' Electrical Inspector: Fire Inspector: 11 10. P&Z Administrator: V& J.a O RE?CBURG City of Rexburg Receipt Number: 19 E Main St. / Rexburg, ID. 83440 Phone (208) 359 -3020 / Fax (208) 359 -3024 0700033 RPRCANVEO' Mechanical Residential Fixtures $135.00 Total: $15.00 $0.00 07 -0080 02/15 /2007 Building Permit Fee 07 -0536 09112/2007 Hookup Fee /Sewer 07 -0536 09/12/2007 Hookup Fee/Water 07 -0536 09112/2007 Mechanical Residential Fixtures 07 -0634 10/1912007 Mechanical Residential Fixtures 07 -0080 02/15/2007 Permit - Electrical 07 -0080 02/15/2007 Residential Plumbing Permit Fee 07 -0536 09/12/2007 Water Meter & Parts ', M- w . "r SOP CHECK 11772 $ 15.00 Total $15.00 genpmtrreceipts $15.00 $713.75 0700033 $1,000.00 0700033 $1,550.00 0700033 $85.00 0700033 $35.00 0700033 $100.00 0700033 $78.00 0700033 $317.00 0700033 VEB 0 6 2008 s CITY OF FiE�G Page 1 of 1 Z v � D) � � 3 3• Q Z 0 W N p o -i m O � yD _ CTt p) (D ,., r* S W; o y Z m -i 3 m —1 -� c -, -0 M _ m m 1T1 r aim' to v CD r y `-; m ' y z CO) cQ m z (1) Q a'*c : E (D �, ■� - v�ya 0 — I M D � :3 �I° '> D C -J �� y -�i c n 0 vvm3 y �0 (Da O CD - 0 v CL m m O 1 64 0 CD H W p �. y '� oo0 O n z�m w_ �z Z CD Cl) 7 - y m M C . T 0 c ° O y S W d c 3 v O 7 (D •a C. (D (J1 � 0 n /� 0 N vi 'n C ;P -0 0 m y 'fl W O (Q ( W (n CD m a m v _� 0 m z D o -0 -4 n N m Q Z R oo y N O O 0 0 v C cn .. y S a (D (D 0 ca m Z i m o .0 r E. .. (D cr D' O '� 0 m m a z�g CL 0 y W � a 3 o Q Q• A <D y O W Q ; Q W< m m 3 y D (C W y Q L O 171 y �"'� W n CD 3 ° n O CD CD z D O s O 3 D C D ( p ( n O as X a = a ow 64 N CO) 3�Z (D m 0 n m O Q c r * °—' m _. c�i (n N CD y a co Z (o � -( C f1 n (C _ N Cl) 0 0 n Q n yo m 0 > r O 0 (D Q..O+� *amng m ° =r o m000.� O �Cy Q N j `< n 0 /� V/ Q Q . CD 0 0§ 0 w C q •� O O S (D 0 g m 3 y (D 00 n a r 0 � . T m N V/ C v O �I m }za CjZyO o v � x OK� A ~ `C o O w Y 'n v � D) � � 3 3• Q Z •� W N . CO W V � CTt T 0 cn ;a MO o N 'n - n r N to v CD m v a m cQ m N : E 0 — I _ v C m 7 :3 (D C to O y O Z oo0 O n z�m w_ �z n' m CD M C W n -4 0 O O A W 7 3 O O C r vi 'n C ;P -0 0 7 W v o m z D o -0 -4 n N m Q Z C) Z v Z i m o .0 r E. .. (D D' O '� 0 m m a z�g (D o Q X N (D 0 z N O O Q O O Q v � D) � � 3 3• Q Q 7 7 C C s OM LFELECTRIC FAX NO. : 3575283 0 �~ Building Saf ety Deportment I 0ty of RexbUrg 19 t MOIn lonelp�®rexburg.org Phone: 208,359,3020 026 Rexburu ID 6344D w Fes: ZW.359.3024 pRIASE z.ox _ BLOC OWNER'S NAME C 01_*C PROPERTY ADDRESS SUBM Feb. 07 2007 05:29PM P1 Lea GITy o 1' RG C'w �,,, . r1mCAlms.F�h11y ('arnmun�a. Permit #07 00033 512 S Millhollow Rd RequiredW ELECTRICAL Fiecmcal Contrac>OS's Name 1(] I�lo�''� � sine9s Nsme Addrtw Ce11 Phone Business Phone a Mccuical Estimate (cost of wwng & labor) C T'I�S ®- p. � ( �' ea+ Xa�dratl�l .includcsar>rryrbtr�cauru(ned �tk� �i4 rc�ridrn�a1 sazietute gfua�ro,ar rb� 9ame dMe) c — _ (:p to 200 amp Sozvice* Se AA-9- ° 201 co 400 emp Service* I Over 400 amp Service's _ Tetngoxa 7 Construction Service, 200 auk or less, one location (fox a pe i od riot co U..ceed 1)'car) E369dng Residential (4 of Branch Circuits) Spa, Hot Tub, Swiu z & pool E.lectdc Central Syeteuts Keating and /or Cooling (when not pert of a naw Dt.6 dkct..j cos =d zo Addi stsuc ve is , dnnal wee Z) biodulu, Manufactured or Mobile ,Home Othe<'=Mllations: Wining not Tecifical[y covered by any of the above Coat of Wiring & Lab= spa (Domestic Waxz, x=*60a, Sewage) Requested lus c tiom (o 0.ni sting W1t1L1 { - Z'IPoMc9 A.rsivscment/):ridustryl '7�#ntics a mudmum cf3 i ce. AdditicxWina peGZfoaa chaWd at>xqutsnd ilupecioa etc of $40 pe =hoes_ � r lice�sN ansnbca i?ara - . Tb a Rtxh ' avwl tt&-dVk it the san+r ar n mind 6 t)4 sr'dr 011.114& CC AT Y OF REXB URG PERMIT # A BUILDING PERMIT APPLICA Please com lete en ' 19 E MAIN, REXBURG, ID. 83440 If the question does not apply 611 ' or� app 208 - 359 -3020 X326 PARCEL NUMBER mV a Dq:l ,V 1 (We 1 0700033 SUBDIVISION: UNIT 12 S Millhollow Rd -MD Buildcrs (Addressing is based on the information - must be accurate) Smith Addition OWNER NAME: CONTACT PHONE # PROPERTY ADDRESS: PHONE #: Home ( ,4) 3�6co - - 165 Q Work (' ) Cell ( ) OWNER MAILING ADDRESS: - 0 �a In ! < <� IOI� CITY: STATE:_Ta1ZIP: EMAIL FAX APPLICANT (If other than owner) 1 l L� i Ll ewe` (Applicant if other than owner, a statement authorizing applicant to act as agent for ow must accompany this application.) APPLICANT INFORMATION: ADDRESS �G�+ J � I�� � �� CITY: IC STATE; ZIP PHONE #: Home ( ) Work 6W '� � ��� Cell CONTRACTOR MAILING ADDRESS: 3% 5 f o.3f 3w II" TY - RI cA k Lk STATE Mb ZIP Dy � PHONE #: Home ( ) Work (94 - N5 - �OaS Cell (90T 3 1 3 — U U Y EMAI r WXOrfi hj y ► IDAHO REGISTRATION # & EXP. DATE , - LM5 t - q - How many buildings are located on this property? Did you recently purchase this property? O) Yes (If yes give owner's name) Is this a lot split? U YES (Please � PROPOSED USE: —j I (i.e., Single Family Residence, Multi Family, p copy of new legal description of property) Remodel, Garage, Commercial, Addition, Etc.) APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above - mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2003 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. o EE::� I / z _,-( / -0 :3 Signature of Owner /Applicant DATE Do you prefer to be contacted by fax, email or phone? Circle One WARNING — BUILDING PERMIT MUST BE POSTED ON CONSTRUCTION SITE! Plan fees are non - refundable and are paid in full at the time of application beginning „TanyAa L 2005. City of Rexburg's Acceptance of the plan review fee does not constitute plan approval **Building Permit Fees are due at time of application** **Building Permits are void if your check does not clear** 2 Buil Safety Department City of Rexburg 19 E. Main Rexburg, ID 83440 janellh@rexburg.org Phone: 208.359.3020 www.rexburg.org Fax: 208.359.3024 Of REXB URC 1 ,7 o CITY OF REXBURG _ ---- Americas Family Community Affidavit of Legal Interest State of Idaho Cou of Madison I, 0 Y{'L me City Address State Being first duly sworn upon oath, depose and say: (If Applicant is also Owner of Record, skip to B) A. That I am the record owner of the property described on te attached, and I grant m permission to: iM 0 !L" f 7 r e V S 4�— Name Address to submit the accompanying application pertaining to that property. B. I agree to indemnify, defend and hold Rexburg City and its employees harmless from any claim or liability resulting from any dispute as to the statements contained herein or as to the ownership of the property which is the subject of the application. Dated this L day of - r , 20 Signature Subscribed and sworn to before me the day and year first above written. N L'f M.�.Th i *0 ?pl s Notary U 1B G Idaho Residing at: My commission expires: 0/ - U �'- - d - 0 1 y Please complete the eltire Ap p pp NAME b 7 !)()AA <Jm4 1 PROPERTY ADDRESS `� I `� i 0� O lt �,�.1 �f a Permit# SUBDIVISION Dwelling Units: Parcel Acres: SETBACKS FRONT SIDE SIDE BACK Remodeling Your Building /Home (need Estimate) SURFACE SQUARE FOOTAGE: (Shall include the exterior wall measurements of the building) First Floor Area nfinished Basement are Second floor /loft area Finished basement area Third floor /loft area Garage area Shed or Barn Carport /Deck (30" abo e grade)Area Water Meter Quantity: * * * * * * * * * * * ** *Water Meter Size: Requiredffl PLUMBING p Plumbing Contractor's Name: 1 Business Name: Address y r c� Q: k OL40 K0 l Citv c State =b Zip Contact Phone: (app �J D c5�0 Business Phone: 0 JLlS -- 11 Email FIXTURE COUNT Cmcludutg roughed fixtures Clothes Washing Machine Dishwasher Floor Drain Garbage Disposal Hot Tub /Spa Sinks (Lavatories, kitchens, bar, mop) Plumbing Estimate $ Sprinklers Tub /Showers & Toilet /Urinal Water Heater Water Softener (COMMERCIAL /MULTI - FAMILY ONLY) Sign e of License xactox License Number& Expira ' Date Date The City of Aexburg's permit fee schedule is the same as required by the State of Idaho 4 ROM DIAMOND HEATING FAX NO. :1 -208- 522 -7933 Feb. 12 2007 02:08PM P1i1 2 2 P' Y , 1 V J 'v Please complete the � entire APplic,ationt NAME-2d) Q � PROPERTY A.DI RMS ' � �-�G�Y G� pctnlit# SUBDIVISION, Uec6Uik t CollmcuCses Name _, r. _ Nwme Addtvs. !b b0 ! 63 _ _ City (0 n f") ctatN - r- - N 7i- 9'.i Cell Phrase (as) 5 6 P - LI c , 3 3__. - ., _Buatness Phone ( ) - - - - - -- -- •,.:._....__._._..._ ' (0 _6xQ - '� _ Lm9 i1 Mechanical Estimate $ /Multi Family Only) F'l "17.T�q$ ` �,pta.LrX NG' sS CDCa1V (. VIC Family D**&ww only) Spice Heater Dccasatx+* gas -fated applaaueC ,. Incin+etatot s ystem — Bae Pool Heater - - NO GIG Pipe Outlem incb_uiirsg stubbed in or funwe ouders Inlet Pressure (Meter. Supply) PST l (Cimle 4 that ap Cyan Oil Coal Fireplace Electric H y dr o nic: T- ••�• -•W Heat pump Range Hood Veuts Alt Conditioner Cooly Stove Vcnts Ev'apa -Rave Cooler Rath Fan Vents Uvit Heater - othet similar vents & ducts: Furnace Exhaust or Vent ,Uu m Furn=e /Air Condom Combo Dryer Vents 2 Sigaatuxc c= number d- N T Til3 of Ruxbrx'sp.n%i��Go rcb�dxb rr r„a Rr FEB 14 2007 CITY OF E_XBURO Please complete the en Ap P PP NAME PROPERTY ADDRESS l.0 SUBDIVISION Requlredffl - �_eacblv - j MECHANICAL Mechanical Contractor's Name ) ±f C, 7 M 0 W Business Name Address D �16o� 1 City Cell Phone (A�) 5 � q — Ll ? Business Phone ( ) Fax (aoV 6 aD --'I C� 33 Email Mechanical Estimate $ w . z Commercial /Multi Family Only) FIXTURES & APPLIANCES COUNT (Single Family Dwelling Only) Furnace Furnace /Air Conditioner Combo Heat Pump Air Conditioner Evaporative Cooler Unit Heater Space Heater Decorative gas -fired appliance Incinerator System Boiler Pool Heater Exhaust or Vent Ducts Dryer Vents Range Hood Vents Cook Stove Vents Bath Fan Vents other similar vents & ducts: Fuel Gas Pipe Outlets including stubbed in or future outlets Inlet Pressure (Meter Supply) PSI Heat (Circle all that apply) Gas Oil Coal Fireplace Electric Hydronic Mechanical Sizing Calculations must be submitted with Plans & Application Point of Delivery must be shown on plans. Signature of Licensed Contractor License number The City of Rexburg's permit schedule is the same as Permit# i CLalo nil Nei State zip P,3 E4 Date the State of Idaho 5 Me*ry TX Result Report ( Feb, 12, 2001 2:02PM P. 1 ) 2) Date /Time: Feb,12, 2007 2:01PM File Page No. Mode _ Destination Pg(s) Result Not Sent ---------------------------------------------------------------------------------------------------- 3680 Memory TX 5227933 P. 1 OK ---------------------------------------------------------------------------------------------------- Reason for error E. 1) Hang up or line fail E.2) Busy E. 3) No answe r E. 4) No facs imi l e connect i on E. 5) Ex c e e d e d max. E—mail s i z e Pleasc complete th entire Application NAME J ,� " {�' PROPERTY ADDRESS r cue r�}aY L� petaut# SUBDIVISION J RequitledN MECFIANI 4L , J Mecbani�al Contnumt's Name . '�' r f :. ,p 'Busbtess Nam l amo Yl(l � e_6 Cell phoae (a g) 8l'� - � 9 L I I q3 S s usinen Phone ( ) Fax(SD'o -' I E mail Mecbanieal Estimate Commeocial /Mule Family Only) J iS& A.PPLU2VCE5COUNT (Siffg1eAvAn*DweBjng0n1Y) Fmxuce Fxbu t or Vent Ducts Fumaee /Aix Conditioner Combo Dxm Vems Flan Pump Rmi Hood Vents Ak Conditioner Cook Stove Vcuta Evaporative Cooler Bath Fan Vent. Unit Hcatet other si ra. vent. & At Spare Heater Dccounwe gas-fimd sppbaoce IucM=Aor System Boils Pool Heater Fuel Gas Fipe Outlet including stubbed in a fimxre outlet. Inlet Pressure (Meter Supply) PSI Heat (citck all that apply) (� Oil Coal Fireplace Electric Hydtumc Mechanical Sizing Calculations must be submitted with Plans & Aw leratinn Point oDeive must be shown on nlans- St�nae oElirmxd Caonactaa I.icenremm6er Oahe Pt. ��Bnn gYpvaritJb.sdmdibix6n mw e<agrrsl4yxh Saa grldvdn 5 - P. 1 MenTc ry TX Result Report ( Feb. 6. 20011:21AM ) 2) Date /Time: Feb, 6. 2007 11:20AM File Page No. Mode Destination Pg(s) Result Not Sent ---------------------------------------------------------------------------------------------------- 3634 Memory TX 5227933 P. 2 OK ---------------------------------------------------------------------------------------------------- Reason for error E. 1) Hang up or line fail E.2) Busy E. 3) No answer E.4) No facsimile connection E.5) Exceeded max. E—mail s i z e ssara:.aw�m PbvcNl8J59AA70x316 RBXHCJRG Fax Ta Steve Mora From: JaNeli Hansen Fast 322.7933 Paget 2 Phase: Date: February6.2007 RE cc O usgesse O For Renew D i9 ease Con — e st O PkmP ftM U Pfeaee Rwes�de e Commssntc Pease fig out and sign the attached appgcotion for Rob & 5dgy Smith's Addition, list only the fixka that am being added. Thank You. JoNe9 Homan t I Building Safety Department City of Rexburg 19 E Main lanellh@rexburg.org Phone: 208.359.3020 x326 Rexburg, ID 83440 www.rexburg.org Fax: 208.359.3024 Permit# C I T Y O F REXBURG Americas Family Community OWNER'S NAME PROPERTY ADDRESS SUBDIVISION PHASE LOT BLOCK HOME OWNER NER - S ELECTRICAL PERMIT Home Owner's Name Address City. Cell Phone ( ) Fax ( ) Home Phone ( ) OF RrXB tj � o to Zip TYPES OFINSTALLATION (New Residential includes everything contained within the residential structure and attached garage at the same time) Up to 200 amp Service* 201 to 400 amp Service* Over 400 amp Service* Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 year) Existing Residential (# of Branch Circuits) Spa, Hot Tub, Swimming Pool Electric Central Systems Heating and / or Cooling (when not part of a new residential construction permit and no additional wiring) Modular, Manufactured or Mobile Home Other Installations: Wiring not specifically covered by any of the above Cost of Wiring & Labor: $ Pumps (Domestic Water, Irrigation, Sewage) Requested Inspections (of existing wiring) Temporary Amusement /Industry *Includes a maximum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour. Signature of Home Owner The schedule is the same as Date the State of Idaho T Building Safety Department EXEURC City of Rexburg r� o 19 E Main ionellh @rexburg.org Phone: 208.359.3020 x326 Rexburg, ID 83440 www.rexburg.org Fax: 208.359.3024 C I T Y O F REXBURG Americas Family Community OWNER'S NAME O d A J� PROPERTY ADDRESS bo i �l { �� Permit# SUBDIVISION PHASE LOT BLOCK RequiredLY ELECTRICAL Electrical Contractor's Name (I VJ Lt K e L s r ? I -C C-� C �,� _ Business Name i Address P t Ci Q,t lA �(a �S State .A: Cell Phone GjQ 1- Q 1 S I Business Phone (Jug) ���� - 3 (o Fax ( q�) 3 -- 5 a � 3 Email Electrical Estimate (cost of wiring & tabor) $ (COMMERCIAL /MULTI - FAMILY ONLY) TYPES OF INSTALLATION (New Residential includes everything contained within the residential structure and attached garage at the same time) Up to 200 amp Service* 201 to 400 amp Service* Over 400 amp Service* Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 year) Existing Residential (# of Branch Circuits) Spa, Hot Tub, Swimming Pool Electric Central Systems Heating and /or Cooling ( when not part of a new residential construction permit and no additional wiring) Modular, Manufactured or Mobile Home Other Installations: Wiring not specifically covered by any of the above Cost of Wiring & Labor: $ Pumps (Domestic Water, Irrigation, Sewage) Requested Inspections (of existing wiring) Temporary Amusement /Industry *Includes a maximum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour. Signature of Licensed Contractor The License number schedule is the same as Date the State of Idaho Mevy TX Result Report ( Feb, 6. 200�1:38AM) � � � P. 1 2) Date /Time: Feb, 6, 2007 11:36AM File Page No, Mode Destination Pg(s) Result Not Sent ---------------------------------------------------------------------------------------------------- 3636 Memory TX 3575283 P. 2 OK ---------------------------------------------------------------------------------------------------- Reason for error E. 1) Hang up or line fail E.2) Busy E. 3) No answer E.4) No facsimile connection E.5) Exceeded max. E —mail size f9E RefakgID Afoar.V/8.ff9APdOxl26 RMIUMi F ax P-2ZA -0 .��. Ta Richard likes Pram: I JaW Hansen Fax 357 -M Ptges 2 Maw DO W f 6, 2007 Re: CC ❑ WgeM 17 Fef ftW 0 Please C ❑ Please 6hepbf ❑ Muse lseraitle e Commeflic aerie fill out and sign the ahached appNcallon far Rob & Sally SmNh's Addtion. Are you adding a new service or just addng eseuAs8 Please nose if an the applicallan and fez bock. Thank YpU. JaNell Hansen t * ........... m SUBCONTRACTOR LIST Excavation & Earthwork: r" U b I b i e,� - s Concrete: Masonry: , Roofing: I r► �� 1 1 d r S � Insulation: C' ` x A � a A� Dn Floor Coverings: Hea L � e IN N Special Construction (Manufacturer or Supplier) Roof Trusses: Floor /Ceiling Joists: �Om(� Siding /Exterior Trim: EXEMPTI(*S FROM STATE REATRATION As of January 1, 2006, the City of Rexburg can no longer sell permits without having a copy of your State registration number or your exemption from the State registration. Please send a copy of your state registration or fill out this form showing your exemption and send it with your license renewal or your next permit application. (This list is a summarization of Idaho Code Title 54 Chapter 5205, for full definitions of these exemptions please see the State's website at www.ibol.idaho.gov /cont.htm ❑ Currently State licensed pursuant to Title 54 Idaho Code, Chapters: 3 Architects, 10 Electrical Contractors /Journeyman, 12 Engineers /Surveyors, 19 Public Works Contractors (exempt from fee only registration required), 26 Plumbing /Plumbers, 45 Public Works Construction Management Licensing Act (exempt from fee only registration required), or 50 Installation of heating, ventilation and air conditioning systems ❑ Employee or volunteer of a licensed contractor or part of an educational curriculum or nonprofit charitable activity with no wages or salary ❑ Employee of a US Government agency (State, City, County, or other municipality) ❑ Public Utility doing construction, maintenance, or development to its own business ❑ Involved with gas, oil or mineral operations ❑ Supplier doing no installation or fabricating ❑ Contracting a project or projects with a total cost less than $2000 ❑ Operation of a farm or ranch or construction of agriculture buildings exempt from Idaho Building Code ❑ Any type of water district operations ❑ Work in rural districts for fire prevention purposes ❑ Owner who performs work on own property or contracts with a registered contractor to do work as long as the property is not for resale within 12 months ❑ Owner or lessee of commercial property performing maintenance, repair, alteration or construction on that property ❑ Real estate licensee /property manager acting within Idaho Code ❑ Engaging in the logging industry ❑ Renter working on the property where they live with the property owners approval ❑ Construction of a building used for industrial chemical processing per Idaho Code ❑ Construction of a modular building (defined by Idaho Code) to be moved out of state I hereby certify that the above information is true and correct to the best of my knowledge. Signature Print Name Date E Findings of Fact City of Rexburg 12 North Center Phone: 208.359.3020 Rexburg, ID 83440 www.rexburg,.org Fax: 208.359.3022 Canyon View Estates Final Plat clTY OF G . .. ....... . ...................... , 41V ......................... _ .... _... America's Family CorruuuuiCy 1. On September 8, 2006, The Dyer Group presented to the Rexburg Planning & Zoning Secretary a Request and Application for a Final Plat for Canyon View Estates. 2. On September 21, 2006, Winston Dyer presented to the Rexburg Planning & Zoning Commission the Request for approval of the Final Plat for Canyon View Estates. Mary Haley motioned to recommend to City Council to approve the final plat for Canyon View Estates. Joe Laird seconded the motion. None opposed. Motion carried. 3. On October 05, 2006, Winston Dyer presented to the City Council the final plat for Canyon View Estates. Financial Officer Horner asked if recent storms would have been handled by the proposed water basins. Winston said yes, they have designed the storm water management to handle a certain anticipated volume of water runoff. They use a 10 year storm guide in the design of the storm water management system. Council Member Young thanked Winston Dyer for answering all of the questions and preparing the drawings. Council Member Erickson moved to approve the Final Plat for Canyon View Estates; Council Member Stevens seconded the motion; all voted aye, none opposed. The motion carried. X . 1J _ CITY "uF `gtl5W�� A4t[ RIC ;�'a f:vtlE:Y C:��L�1lINf IY 19 E. Main (PO Box 280) Phone: 208 - 359 -3020 x2 Rexburg, Idaho 83440 Fax: 208 - 359 -3024 %1v,1 u.rexburg.org comdev(a7rexburp.orct Final Plat Application Application for Approval of Subdivision Plat The attached Subdivision plan has been prepared in accordance with the Subdivision Regulations of the City of Rexburg, and the following items are shown on the plan or plans, or explanations given with respect thereto. Requirements for Plats All Preliminary Plats shall be 24" x 36" foldable, drawn to scale, North point, dated. -% 0, �� to The following shall be shown on the Preliminary Plat or shall be submitted separately: q/� 1. The name of the proposed subdivision: Canyon View Estates 2. The location 350 South and Mill Hollow Road Acreage 17.4 Number of Lots 36 3. The names, addresses and telephone numbers of the subdivider or engineer or surveyor who prepared the plat: ❑! Subdivider S E P 11 2006 Name: Valeo Manallement Address: 1716 N 900 East c/o Kerry Schneider North Ogden, UT LW Phone Number: 801 - 721 -0165 Cell Number: 801 - 721 -0165 Engineer Name: Dyer Group, LLC Address: 310 N 2 " East #153, Rexburg Phone Number: 656 -8800 Cell Number: 390 -9700 Surveyor Name: same as above Address: Phone Number: Cell Number: 4. The name and address of all property owners within 300 feet of the external boundaries of the subdivision whether or not bisected by a public right -of -way as shown on record in the County Assessor's office. submitted with preliminary plat 5. The legal description f the subdivision. see plat 6. A statement of the intended use of the proposed subdivision such as: Residential — (single family, two - family and multiple housing); Commercial, Industrial, Recreational or Agricultural. Show sites proposed for parks, playgrounds, schools, churches or other public areas. single family residential 7. A map of the entire area scheduled for development if the proposed subdivision is a portion of a larger holding intended for subsequent development. proposed plat covers entire property 8. A vicinity map showing the relationship of the proposed plat to the surrounding area (1/2 mile of minimum radius, scale optional). submitted with preliminary plat 9. Streets, street names, rights -of -way, and roadway widths, including adjoining streets or roadways, curbs and sidewalks. see plat. Street R/W = 68', street= 44' wide with curb and gutter, 7' boulevard, and 5' sidewalk 10. Lot lines and blocks showing the dimensions and numbers of each. see plat 11. Contour lines, shown at five (5) feet intervals where land slope is greater than ten percent (10 %) and at two (2) feet intervals where land slope is ten percent (10 %) or less, referenced to an established bench mark, including location and elevation. see preliminary plat 12. Any proposed or existing utilities including, but not limited to, storm and sanitary sewers, irrigation laterals, ditches, drains, bridges, culverts, water mains, fire hydrants, power, gas, street lights and their respective profiles and easements. see preliminary plat 13. A copy of any proposed restrictive covenants and /or deed restrictions. (To be attached or submitted with final plat). attached 14. Any dedications to the public and /or easements, together with a statement of location, dimensions, and purpose of such. see plat (streets) Please complete the following: (If not applicable, please fill in with N /A) 1. What is the land use and existing zoning of the proposed subdivision and the adjacent land? presently agricultural use, zoned LDRI 2. Does subdivision conform to present zoning? Yes 3. Requested zoning: already LDRI 4. Variance Requested: Yes No X (If yes, attach written request) 5. Requesting annexation to City? In City 2 I l fEMS FOR CONSIDERATION 1. Probable impact of the proposed project on the environment effect on: a. Public safety and convenience streets to City standards, minimum of 2 approaches to all lots b. Fire, police, and ambulance services as above c. Recreation covered by impact fees d. Schools 70 pupil increase in enrollment distributed among all grades e. Displacement or relocation of people none f. Land values improves to residential values g. Local and long- distance travel, i.e., highway and local road impact 5th South extended through to Mill Hollow, Shosone will eventually extend to 7 th South h. Behavior of wildlife species already disturbed area i. Water quality and effect on underground water supply municipal water supply j. Noise pollution minimal in residential area k. Air pollution minimal in residential area 1. Method proposed to dispose of storm drainage waters catch basins and infiltrators m. Extent of increased city road maintenance, including snow removal roads in subdivision n. Floodplain— methods proposed to alleviate effect of 100 -yr flood; effect on adjacent properties. N/A o. provisions for housing for persons of low and moderate income N/A p. Harmony with the character of surrounding developments continuation of existing development 2. Probably adverse environmental effects which cannot be avoided a. Traffic Use minimal (37 cars per hour peak) b. Rights -of -way required dedicated to City, including west side of Mill Hollow c. Pollution effect on existing environment _none as City standards are followed 3. Relationship between local short-term uses of man's economic environment and the long -term productivity. a. Existing vs. proposed tax base increases tax base b. Costs to City if proposal approved (annual) maintenance of streets 4. Measures taken to minimize harmful effects on environment a. Effects of construction activities dust and noise during construction, minimal traffic disruption b. Erosion control BMP's followed c. Stream pollution prevention N/A d. Borrow -pit rehabilitation backfill behind curbs e. Fencing east perimeter of subdivision otherwise private lot fencing f. Buffer zones consistent with adjacent uses g. replacement of parklands or farmlands impact fees cover recreation, loss of some farmland 5. Is this plat plan harmonious with and in accordance with the general objectives or with any specific objective of the City's Comprehensive Plan? consistent with Comprehensive Plan, established zoning, and approved preliminary plat IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT THE REXBURG PLANNING AND BUILDING DEPARTMENT DEVELOPMENT AGREEMENT CANYON VIEW ESTATES SUBDIVISION: OF THE CITY OF REXBURG 4 AGREEMENT, made this day of November, 2006, by and between the CITY OF REXBURG, a municipal corporation, hereinafter called "CITY," 12 North Center, P. O. Box 2H, Rexburg, Idaho 83440, Edge Holdings and Kerry Schneider, LL(-, hereinafter called the "DEVELOPER," whose mailing address is: 1716 N 900 East North Ogden, UT 84414 WITNESETH: WHEREAS, Developer is the sole owner, in law or equity, of a certain tract of land in the County of Madison, State of Idaho, which land (hereafter referred to as the Development) is more particularly described in EXHIBIT "A" Canyon View Estates attached hereto and by this reference made a part hereof; and WHEREAS, Developer has requested the Development be approved by the City and has or will submit Improvement Plans for the Development described in the caption of the Agreement; and WHEREAS, City water, sanitary sewer and storm drain facilities are adjacent and accessible to Developer's land; and WHEREAS, Developer is responsible for the street and utility improvements within the Development; NOW, THEREFORE, in consideration of the terms and conditions set forth herein, the parties agree as follows: I. DEVELOPMENT OF Canyon View Estates The City agrees to provide water and sewer service to the Development, subject to Developer's acceptance and performance of the terms and conditions of this Agreement and the terms and conditions contained in the Special Conditions attached hereto and made part hereof; DEVELOPMENT AGREEMENT - 1 2. IMPROVEMENT PLANS Developer has filed, or will file, ,tad the City Engineer has/ or will approve a complete set of Improvement Plans (hereafter referred to as the "Street and Utility Improvement Plans ") showing all streets, sewer lines, water lines, fire hyd n its, storm drains, street signs, street lights, traffic control devices barricades and other public impro Tements contemplated within the Development. The Improvement Plans also show the proposed lo, ation of other public utilities (telephone, gas and electricity) and irrigation facilities affected by the Development. Such Improvement Plans are incorporated herein by reference as though set out in "ull. Improvement plans for any water, wastewater or storm drainage facilities are also to be submitted to the Idaho Division of Environmental Quality for their review and approval. It is the responsibility of the developer to obtain DEQ approval prior to starting any construction on water, wastewater, or storm drainage facilities. 3. CONSTRUCTION OF PUBLIC IMPROVEMENTS. Unless otherwise agreed in the Special Conditions, Developer will, at its expense, design and construct all public improvements shown in the Street and Utility Improvement Plans. Unless otherwise agreed in writing by the City Engineer, Developer will construct all public improvements within the Development in strict accordance with the Improvement Plans and the City Standard Engineering Drawings and Specifications (hereafter referred to as the "Standard Specifications ") in effect at the time the construction is accomplished. The Standard Specifications are incorporated herein by reference as though set out in full. 4. PERMITS Developer shall obtain all right -of -way, excavation or other permits required by local ordinance or any State agencies and comply with all requirements therein with respect to the timely performance of the work governed by such permits. The Developer is required to apply for permit coverage from EPA after developing a site - specific Storm Water Pollution Prevention Plan. 5. COMPLETION OF PUBLIC IMPROVEMENTS Developer agrees that if, a portion or portions or the entirety of such public improvements need to be completed in the interest of the public health, welfare or safety, Developer will forthwith construct such public improvements. If Developer does not commence construction of such public improvements within a reasonable time DEVELOPMENT AGREEMENT - 2 after such finding is made or if Developer does not complete such c.; !Taction within a reasonable time thereafter, the City may move on the developers bond and construct or have constructed such facilities at Developer's expense. The City Council shall not make such finding unless Developer has been given at least ten (10) days advance written notice of the date and place of the meeting and Developer has been given an opportunity to be heard at such meeting At or before the meeting, the City Engineer shall furnish Developer a cost estimate for complet ng the required portion or Portions of such public improvements. 6. INSPECTION Developer will retain a professional engineer (he "ter referred to as the "Project Engineer ") licensed within the State of Idaho to supervise, insp(° -t and test the construction of all public improvements within the Development in order to ensure such improvements are constructed in accordance with this Agreement, the Improvement Plans --I the Standard Specifications. Developer will not materially deviate from the Improvement Plans or Standard Specifications without the express written approval of the City Engineer. The following minim testing is required as a stipulation of this Agreement; (All inspections to be done as per the current ISPWC) SEWER LINES (To be inspected 30 days after installation and completion of backfill, but before geotextile fabric for the road is installed.) 0 CCTV inspection (CCTV inspection will be completed by the City's Sewer Department) • Pressure testing • Deflection testing WATERLINES (CLASS 50 D.I. ) • Pressure testing 0 Bacteriological testing General inspection of fire hydrants, valves, and other water facilities (To be completed by the City's Water Department) DEVELOPMENT AGREEMENT - 3 ROAD CONSTRUCTION • Density Tests on Sub base, Granular borrow, Road base, and Asphalt (One p( every 1000 ft of roadway as per ISWPC ) • Field sampling (Gradations 2 per material) • Asphalt mix design • Concrete strength — one slump and 3 strength cylinders per 50 C.Y. of concrete MISCELLANEOUS • Additional testing may be required if so stipulated in the special conditions 7. CORRECTED IMPROVEMENT PLANS. Prior to acceptance of the Development, Developer will file "Record Drawings" Improvement Plans (hereafter referred to as the "Corrected Improvement Plans ") with the City Engineer. Such Corrected Improvement Plans shall be prepared by the Project Engineer and shall show the actual "as constructed" location of all public improvements within the Development including the horizontal and vertical location of all water, sewer and storm drain lines, individual building service lines, curb and gutter alignment and street grades. Such Corrected Improvement Plans shall also specifically show all changes between the original Improvement Plans and the public improvements as actually constructed. The Project Engineer shall also certify upon the Corrected Improvement Plans that such Plans correctly show all public improvements as actually constructed and that such public improvements have been constructed in accordance with the Standard Specifications in effect at the time such construction was accomplished. The original linens or mylars of these "Corrected Improvement Plans ", and an electronic copy in AutoCAD format of such drawings shall become the property of the City of Rexburg. The Project Engineer shall also deliver to the City Engineer all compaction reports, daily construction logs, reports, written tests, pressure test results on all water lines, bacteria tests on all water lines, pressure tests on all wastewater lines, analysis and other data as may be necessary to verify or support the certification of the Project Engineer. DEVELOPMENT AGREEMENT - 4 8. ACCEPTANCE OF DEVELOPMENT Upon satisfactory completio , of such public improvements and facilities and Developer's delivery of Corrected Improvement P ins, the City will accept the Development. Such acceptance shall not be valid unless expressly n cknowled; ed in writing by the City Engineer. Except as otherwise expressly provided in the Special Conddtions, upon acceptance of the Development, the City shall assume ownership and cont of of all public facilities within any dedicated street or public utility right -of -way within the Development. Acceptance of the Development shall not be deemed as a waiver of Developer's fa_ ure to fully and completely perform the terms and conditions hereof or as a waiver or release of the warranty set forth below. Prior to acceptance the owner must submit to the City Engineer t c following documents: • Water line test results • Sewer line test results • Road construction test results • Corrected improvement plans (Auto Cad format) • Engineers certification of compliance with approved engineering plans Once all information is submitted to the engineering department the City engineer will file a letter accepting the development for city control and maintenance. 9. WARRANTY Developer warrants that the materials and workmanship employed in the construction of all public improvements within the Development shall be good and sound and shall conform to generally accepted standards within the construction industry. Such warranty shall extend for a period of one (1) year after acceptance of the Development by the City, provided nothing herein shall limit the time within which the City may bring an action against Developer on account of Developer's failure to construct such improvements in accordance with this Agreement, the Improvement Plans or the Standard Specifications. 10. WATER & SEWER HOOKUP FEES & MONTHLY UTILITY RATES Water and sewer hookup fees and monthly utility rates are established by City Resolution. Such rates are subject to updating from time to time. Developers of individual homes will be required to pay for DEVELOPMENT AGREEMENT - 5 the appropriate hookup fee for the size of water or sewer hookup dc-sired. If excavation is required within any public right -of -way, an Excavation Permit will also be required. The home owner's developer will be required to install the water service line and purchase the necessary water meter materials as specified by the City Water Department, for use it the water service connection. The home owner's developer or his plumber will be responsible for acquiring the required plumbing permits and for all costs associated with the installation of the - 7Tater service connection. 11. STREET IMPROVEMENTS AND SIDEWALKS STREET CONSTRUCTION Developer will construct all streets in accordance with the Street and Utility Improvement Plan. Said construction shall conform to the typical street design cross - sections which apply to the type of road construction required in the development. Said cross - sections are attached hereto and specifically made a part of this agreement. It is the policy of the city of Rexburg to pay for any street costs which may be required by the city but which exceed the standards required in a particular development. Any street cost sharing by the City of Rexburg is set out in the Special Conditions attached hereto SEAL COATING OF STREETS. All streets within the development are to be seal coated with an approved chip seal coat within two (2) years of their construction unless special arrangements are made with the city engineering department. The developer may contract with the city to have the streets seal coated under a city seal coating project with all costs paid by the developer. SIDEWALKS. Developer or homeowner is responsible for installing 5 ft. sidewalks in the development. All sidewalks associated with the development are to be completed within not more than three (3) years after the final plat of the subdivision is recorded. As lots are developed the sidewalks are to be constructed prior to the issuance of a certificate of occupancy. Lots that are not developed within the three (3) year period are to have the sidewalks installed by the developer. Failure to construct the sidewalks within the allowed period will result in the lots being included in a Local Improvement District and the resulting costs assessed against the property. DEVELOPMENT AGREEMENT - 6 12. STORM DRAINAGE FACILITIES. The Developer will construct all on -site and off - site storm drainage facilities for this project with no financial participation _ -)m the City. Storm drain facilities will consist of at least a collection system and storage facilit, 1pproved by the city and DEQ. The design of the storm water facilities is to be done in accordance with accepted engineering practices. Storm drain facilities within the development will incluc'e piping, catch basins and a storm water detention area as approved by the Engineering Department and shown on Street & Utility Improvement Drawings. Unless otherwise agreed to between the parties hereto, operation and maintenance for the storm water detention facility after the final plans have be -n developed and approved will be the responsibility of the Developer or Homeowners Association. 13. FAILURE TO PAY FEES In the event Developer fails or refuses to pay any of the fees, charges or costs set forth herein, the City may de -annex any property owned by Developer within the Development, or refuse to allow the development to connect to city owned water or wastewater systems, or declare the entire unpaid balance immediately due and payable and collect such sums in the manner provided by law, or may pursue any other remedy set forth herein or as may be available at law or in equity. All such remedies shall be cumulative and the City may pursue the same separately or simultaneously as it deems necessary or appropriate. In the event of such acceleration, all sums due shall bear interest at the rate established by law for judgments entered in the State of Idaho. 14. PARTICIPATION BY CITY The parties agree that those portions of the water mains and sanitary sewer lines, (hereafter collectively referred to as the "Shared Work "), the cost of which the City has expressly agreed to pay pursuant to the Special Conditions, including any water or sewer line extensions, increased line size or capacity are required because of future service needs originating from properties not owned by Developer and located within the vicinity of the Development and that sound planning requires construction thereof at the present time in order to accommodate future expansion and development. In recognition of the cost savings which can be accomplished by construction of such excess capacity and improvements concurrently with the facilities to be constructed for Developer's purposes, and the impracticality or impossibility of constructing such excess capacity and improvements separately or at a later time, Developer agrees to design and construct such facilities subject to the City's agreement to reimburse Developer for a f portion of such costs, all as set forth in the Special Conditions. Prior to the commencement of the DEVELOPMENT AGREEMENT - 7 Shared Work, Developer shall obtain and deliver to the City three (3) independent bona fide bids for the performance of such work from qualified and responsible contractors. Such bids shall be solicited and itemized in a manner which allows clear and specific identification of that portion of the construction work for which the City is responsible, or the City and the Developer may agree upon an equitable amount covering the City's participation in the shared work within the Development. The City shall have no obligation to pay for any portion of the costs of the Shared Work unless prior to the commencement of the work the parties have expressly agreed in writing to a specific amount for which the City will reimburse the Developer. Payment of such costs by the City shall be due within thirty (30) days from acceptance of the Development by the City and delivery of an itemized statement to the City setting forth in detail the total amount of the costs for which the City is responsible. 15. OCCUPANCY No building within the Development shall be used or occupied for any purpose other than for the construction of such building or structure, unless all public improvements within the Development have been completed and accepted by the City Engineer. The City may withhold Certificates of Occupancy until all such work has been completed. 16. DEFAULT In the event Developer fails to comply with the terms and conditions hereof in any material respect, the City may withhold the issuance of any building permits, certificates of occupancy or the connection of water or sewer service to any property owned by Developer and located within the Development, until such default is fully corrected. 17. NOTICES Any notice required by this Agreement shall be mailed to the receiving party at the address set forth above or such other address as may be delivered to the sending party in writing. Such notice shall be mailed by certified mail, return receipt requested, postage prepaid and addressed as set forth above and shall be deemed received upon its deposit in the United States mail in such manner. 18. RECORDING FEES Prior to the approval of the Development by the City Engineer, Developer shall pay to the City all recording fees necessary to record this Agreement with the Madison County Recorder's office. DEVELOPMENT AGREEMENT - 8 19. IRRIGATION DISTRICT RELEASE Prior to the final approval of the Development, Developer shall obtain a certification from any irrigation district, canal company, ditch association or other similar water delivery entity who provides or delivers water to any property located within the Development or who provides water through a facility passing through the Development. The certification shall state that the water rights for all property within the Development have been transferred from the property and that all liens and assessments of such water delivery entity have been released. Or, the certificate shall state that all irrigation facilities that have been disturbed or altered by the Development have been repaired or reconstructed to the satisfaction of the irrigation water user and /or the irrigation entity owning or operating said irrigation facilities. Developer will be responsible for maintenance on any modifications to the irrigation system unless otherwise specified in writing. 20. BONDS. Prior to the beginning of construction the Developer maybe required to file with the City the Bonds as required in the Subdivision Ordinance. Failure to file the appropriate bonds will be justification to refuse the issuance of any building permits. 21. CONFLICT WITH STANDARD SPECIFICATIONS In the event of any conflict between the terms of this Agreement or the Improvement Plans and the Standard Specifications, the terms of this Agreement or the Improvement Plans shall prevail over any contrary provision of the Standard Specifications. In the event of any conflict between the terms of this Agreement and the Improvement Plans, the terms of this Agreement shall prevail. 22. COVENANTS APPURTENANT TO THE LAND All covenants and conditions set forth herein shall be appurtenant to and run with the Development and shall be binding upon Developer's heirs, successors or assigns. 23. REMEDIES CUMULATIVE All remedies herein are cumulative and, to the extent not wholly inconsistent with each other, may be enforced simultaneously or separately, at the sole discretion of the City. 24. GOVERNING LAW This Agreement shall be governed by the laws of the State of Idaho. The venue for any action arising out of this Agreement shall be exclusively in the District DEVELOPMENT AGREEMENT - 9 Court of the 7th Judicial District of the State of Idaho, Madison County, or in the United States District Court for the District of Idaho. 25. ENTIRE AGREEMENT This writing evidences the final and complete agreement between the parties and no other prior statement, representation or understanding shall be binding upon the parties unless expressly set forth herein. 26. SEVERABILITY If any provision of this Agreement is determined to be invalid or illegal, the remainder of the Agreement shall not be affected. 27. WAIVER Waiver by the City of any breach of any term, covenant or condition shall not be deemed to be a waiver of that term, covenant or condition on any subsequent breach of it or any other term, covenant or condition. No term, covenant or condition of this Agreement shall be deemed to have been waived by the City unless the waiver is in writing by the City. 28. EFFECTIVE DATE This Agreement shall become valid and binding only upon its approval by the City and upon its execution by the Mayor. IN WITNESS WHEREOF, the parties have hereunto set their hands and seals the day and year first above written. DEVELOPMENT AGREEMENT - 10 FOR THE CITY OF REXBURG AS TO Public gin Works Difector/ City E eet, John Millar I APPT,�D,� By: . t At W %I— 4;:!�ATTEST: Mayor, Shawn Larsen By:— City Clerk, Kay STATE OF IDAHO) : ss. County of Madison) 0 ?'P0'R .4 ..... ............... On this day of October 2006, be etsigned, a Notary Public for f Idaho, personally appeared Shawn Larsen, known to me to bee Mayor of the City of Rexburg, the municipal corporation that executed the foregoing document, and acknowledged to me that such City executed the same. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal the day and year first above written. ' if Notary Public for Idaho p,R Y Residing at Rexburg, Idaho to My Commission Expires: - 7[7-Z,1Z--01Q puso TE DEVELOPMENT AGREEMENT - 11 DEVELOPER Edge Holdings and Kerry Schneider, LLC. By: Kerry Schneider Its: Managing Member (SEAL STATE OF Idaho) County of Madison) ss. On this 1 day of November, 2006 before me, the undersigned, a Notary Public for said State, personally appeared known or identified to me to be the Authorized Agent of the Limited Liability ColApany that executed this instrument, and acknowledged to me that such Limited Liability Company executed the same. IN WITNESS WHEREOF, I have hereunto set my hand and affixed my official seal the day and year first above written. ' Notary Public � (A R Y •: s Residing at: > . z My Commission Expires: - 717 , pus`iG ,..T��� I G ; A I T E, O '- ************************************************************ * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** DEVELOPMENT AGREEMENT - 12 Special Conditions The City of Rexburg, hereinafter referred to as `City' and Edge Holdings and Kerry Schneider, LLC. , hereinafter referred to as `Developer' hereby agree to the following additional terms and conditions: 1. STREET IMPROVEMENTS. The City will not share in the cost of widening Rolling Hills and NMollow to half of typical section no. 1. The City will not share in the cost of all other interior streets of the subdivision and they shall be built according to typical section no. 1. The construction of Shoshone will be constructed in accordance with the requirements of typical section no. 1 as attached hereto. The City shall pay for all costs of street construction over 19.5 feet on Shoshone Ave. ' 5. FRONT FOOT WATER CHARGE AND EXTENSIONS The subject property has approximately 990 lineal feet of frontage along an existing city water line that the City installed within the proposed development in the past. The Developer shall reimburse the City in accordance with the current ordinance as follows: Front footage costs for water line: $14,850.00 The developer will be responsible for the installation of all additional water lines, service lines, valves, fire hydrants and related work within the proposed development. 6. FRONT FOOT SANITARY SEWER CHARGES. The subject property has NO lineal feet of frontage along any sanitary sewer line that the City has installed. The Developer shall reimburse the City for his share of the costs of said utility as follows: Front footage costs for sanitary sewer lines: NONE 13. FRONT FOOT STORM DRAIN CHARGES. The subject property has NO lineal feet of frontage along the storm drain line that the City has installed. The Developer shall reimburse the City for his share of the costs of said utility as follows: Front footage costs for storm drain charges: NONE. DEVELOPMENT AGREEMENT - 13 14. LOT GRADING DESIGN. The Developer shall provide to t � City individual lot site grading plans for storm water runoff. These plans shall be provided befor_ ° any building permits are issued. FOR THE CITY OF REXBURG A R AST LR M : Pub c Works hector/ City Engineer, John Millar APP Mayor, Shawn Larsen DEVELOPER Edge Holdings and Kerry Schneider, LLC. By: Kerry Schneider Its: Managing Member ATTEST: By: fs�,, City Clerk, Blair Kay (SEAL) O RP OR r SEAL 0 OF 10Pxx DEVELOPMENT AGREEMENT - 14 i Exhibit A 1 of 2 co . LLJN¢ < -Z � F- W Ld w � w Wr �aQO W = Z O00 0 .�� Q�H z W Z Z Q t-X0 O U U) z O QFZQ a- 0 a F _ [if En Qa� 1 Z ¢ � L.1_. I �w� �I 41 G aNTTTT2TT J W J � � a I - C 6 afi +r +ww `Sa 5> X I @@ al pp, Fo °a 3 S�iw I d1 � I s= € g ',._� Pig g §§ a m�B�o ng €Ogm �AeT tJteeY� P N ifts � b W �<In n ��� >- _ .J 000 _uyEYpt +r +ww `Sa 5> X I @@ al pp, Fo °a 3 S�iw I d1 � I s= € g ',._� Pig g §§ a m�B�o ng €Ogm �AeT tJteeY� P N ifts Exhibit A 2 of 2 I l it yEY01f d N b U) o w Dez <W o -� q >- � ' Z O o <5 n Z z Q 0 o U� Q k�. Ig o ug � g S u Ii s o yyK== tl r'. h b I Oi 113 z� i �� _ aC ,5 5 €v § 1 1, F _ Rcjy �Ej� N W rn f— LJ W W � WN +- �N W > Q412 O.:.b .� �• Q S3E 5 (sib.. i t Q=ZO f Q < s �� 4 � 4 � i_Sg ate' 8 o; 0O= Q 1 §0 Qa5 J i � Ra � g, e b ' s� F Z e L� I l it yEY01f d N b U) o w Dez <W o -� q >- � ' Z O o <5 n Z z Q 0 o U� Q k�. Ig o ug � g S u Ii s o yyK== tl r'. i s o W .. y W Y J Q � W A N z z j y I z Z ¢ J l7 . Q U A Z Q J Y J W A H x W W Cl) Q W 3 H 0 Z z ix W A SW ti 0 , 2 O N W Y J Q � 3 W A rn t\ W Z J J Q W VI F W W F-- Z J Q F- F U Z Lit W (/1 A Q W U �CL _l. > Q � El Z z 0 uIQ a Q' Q U N 11� W d O J Cl) L7 Z d Q U to Z J Y J Q � W R N F- E o W M K M Iq N H F- N W Z z z A Z n W A SW ti N W Z W ¢ < °1 ¢ CL �Q ¢ A A a a oc U ° ¢ x F- a ZK�. Z 3 Q -3i � U U Lj J LL3 of K U Q W N QOU M U F • W Q O J Y iq Q \ d W 2M I 1 ¢ 2 ¢ Z J Q F_ O ti N fe N \L7 W J W f F_ M N W W Z d 0 -1 Q J Cl) IL) U z W W ¢ I LO Z r- H ~ .{ LO F- �3 f W Z J J Q W VI F W W F-- Z J Q F- F U Z Lit W (/1 A Q W U �CL _l. > Q � El Z z 0 uIQ a Q' Q U N 11� W d O J Cl) L7 Z d Q U to Z J Y J Q � W R N F- E o W M K M Iq N l z Y a ¢ U � I 1 Y _ a Y F- • c a W H N z A Z n N W Z N F- �Q ¢ A A z I: ° ¢ Z 3 x� f¢ v � U 2 W fL U Q W U M NQ0 U A Q F- . PT ¢ V L- d W 1 < ¢ ¢ F- ~ � O ti W J MN W 0 Z J w \ F w Cl) IL) U W ¢ z F¢-- !� LL. r- m W Q .{ W G' . F- �3 f Q � Z� W W C a J A F- Q � � � W�> F �U IU F- J Q W Cl) W A _1 U l z Y a ¢ U � I 1 Y _ a Y F- • c a W g 03 07 03:48p Myron Creager 208 -356 -3988 p.1 CITY OF R M URG • �' UILDING PERMIT APPLICATION 'lease 4 0700033 19 E MAIN, REXBURG, ID. 83440 If the ques 512 S Millhollow Rd 208- 359- 3020 X322 PARCEL NUMBER: L2 c I E (� I l� (� - - • - -- r - . ___ _. _ ._ SUBDIVISION: UNIT# BLOCK# LOT# (Addressing is based on the information - must be accurate) OWNER: 'a l CONTACT PHONE # � ! 3 S� PROPERTY ADDRESS: all PHONE #: Home ( ) Work ( ) - V , Y Cell( ) F5 Ss W /1 - 'ice OWNER MAILING ADDRESS: CITY: ,� STATE�7—ct ZIP EMAIL FAX APPLICANT (If other than owner) (Applicant if other than owner, a statement authorizing applicant to act as agent for owner must accompany ffiis application.) APPLICANT INFORMATION: ADDRESS CITY: STATE; ZIP EMAIL PHONE #: Home ( ), CONTRACTOR Work ( ) Cell( ) MAILING ADDRESS: S ` CITY PHONE: Home# Work# ✓ �V Cell# EMAIL FAX How many buildings are located on this property? Did you recently purchase this property? No Yes (If yes give owner's name) Is this a lot split? NO YES (Please bring copy of new legal description of property) PROPOSED USE: (i.e., Single Family Residence, Multi Family, Apartments, Remodel, Garage, Commercial, Addition, Etc.) APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury I hereby certify that I have read this application and state that the information herein is correct and I swear that any information which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. 1 agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to eater upon the above - mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2000 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 d� a� Signat6e of Owner / Applicant U it 1 Do you prefer to be contacted by fax, email or phone? Circle One r t ;), WARNING —BUn Dp4G PERMIT MUST BE POSTED ON CONS N S � 7 Plan fees are non - refundable and pre paid in full at the time of application Jar 1 ZO S. 2 City of Rexburg's Acceptance of the plan review fee does not constitut Ian proval . 171 ^ R EXgURG FAX STATE °` ZIP -YD Aug 03 07 03:48p Myron Creager 208- 356 -3988 p•2 ' ase c® �3l�"�e the en I°��p�1j��t16ID P Ia tine question does (S ap ffili in Ivy. ffoi Lion applicable NAME Permit# PROPERTY A 12ESS —// S �? �' . SUBDIVISION .required P I MECHANICAL Mechanical Contractor's Name: C 6Z. d— ,- Business Name: Address g',5 J� ,�, pjf © Y W y e l City o��✓ State Zip �3�� Contact Phone: ( ) �s 9� Business Phone: ( } Email Fax 356 IV' Mechanical Estimate S (Commercial/Multi Family Only) FIXTURES d'c APPLIANCES COUNT (Single Family Dwelling Only) Air Conditioner Bath Fan Vents Range Hood Vents Boiler Cook Stove Vents Decorative Gas Fireplaces Dryer Vents Evaporative Cooler Exhaust or vent ducts Fuel (gas) piping fixtures or appliance outlets Furnace Furnace /Air Conditioner Combo Heat Pump Incinerator Pool Heater Heat (Circle all that apply) (0 Oil Coal Fireplace Electric Space Heater Unit Heater Mechanical Sizing Calculations must be submitted with Plans & Application Point of Delivery must be shown on plans. Signature of Licensed Contractor Licen se number Date Required! The City of Rexburg's permit fee schedule is the same as required by the State . of fdaho 5 • P. 1 Memory TX Result Report ( Aug, 7. 2007"12:13PM) 1) 2) Date /Time: Aug. 7, 2007 12:12PM File Page No. Mode Destination Pg(s) Result Not Sent ------------------------------------------------------------------- 4652 Memory TX 35639$$ P. 1 OK --------------------------------------------------------------------- Reason for error E. 2) Busy E.1) Hang up or line fail E. 3) No answer E.4) No facsimile connection E. 5) Ex c e e d e d m a x. E m a l s i z e RMIMG C t R m Ooporfmoirt of Commonly fJnwlopmonl i9 E N6irt 8L / NR6ong, m-39�0 FFOne (208) 35 9302➢ 1 Far (203j 3543026 A*.10( 7 y`t- •b •c CITY OF RE"IJRG City of Rexb - - -C,. — - Department of Pommunity Development America:< FAmity Cnmmunity 19 E Main St. / Rexburg, ID. 83440 Phone (208) 359 -3020 / Fax (208) 359 -3024 The following fee amounts for this permit application are unpaid at this time: Building Permit Fee 2832211 $ 0.00 Mechanical Residential Fixtures 2832212 $ 85.00 Permit - Electrical 2832213 $ 0.00 Plan Check Fee 2832220 $ 0.00 Residential Plumbing Permit Fee 2832214 $0.00 Total: $ 85.00 Page 1 of 1 City of Rexburg Department of Comm Development 0 Receipt Number: 19 E Main St. / Rexburg, ID. 83440 Phone (208) 359 -3020 / Fax (208) 359 -3024 0700033 RPRCANVEDd Hookup Fee /Sewer 0700033 RPRCANVEDd Hookup Fee/Water 0700033 RPRCANVEDd Mechanical Residential Fixtures 0700033 RPRCANVEOd Water Meter & Parts $1,000.00 $1,000.00 $0.00 $1,550.00 $1,550.00 $0.00 $85.00 $85.00 $0.00 $317.00 $317.00 $0.00 Total: $2,952.00 a 07 -0080 02/15/2007 Building Permit Fee $713.75 0700033 07 -0080 02/15/2007 Permit - Electrical $100.00 0700033 07 -0080 02/15/2007 Residential Plumbing Permit Fee $78.00 0700033 a y CHECK 1020 $ 2,952.00 Total $2,952.00 1 SEP 14 20 Y OF r genprrtrreceipts Page 1 of 1 I s H P 512 MILLHOLLOW RD T REXBURG, ID 83440 0 SPECIAL INSTRUCTIONS: RDER DATE / / C onfirmed Date Roof Trusses QUOTE FORM 0 MD BUILDER Date 01/31/07 Page 1 # 601170 -7 JOB # SMITH REMODEL SALES REP JOE OLSEN BY DATE BID JO LAYOUT ENG. BY DELIVERY INSTRUCTIONS: Plant Location: Idaho Falls PROFILE LABEL QTY I T/C P B/C PTCH SPAN s OVERHANG 0 BRACING NOTES UNIT L D j # � o Idaho Falls Shelley PRICE PRICE 3715 Bombardier Ave. 580 N. State Job Idaho Falls, ID 83402 Shelley, ID 83274 Name Office: (208) 523 -6691 Office: (208) 357 -3468 Fax: (208) 522 -6459 Fax: (208) 357 -7466 Model: I s H P 512 MILLHOLLOW RD T REXBURG, ID 83440 0 SPECIAL INSTRUCTIONS: RDER DATE / / C onfirmed Date Roof Trusses QUOTE FORM 0 MD BUILDER Date 01/31/07 Page 1 # 601170 -7 JOB # SMITH REMODEL SALES REP JOE OLSEN BY DATE BID JO LAYOUT ENG. BY DELIVERY INSTRUCTIONS: Plant Location: Idaho Falls PROFILE LABEL QTY I T/C P B/C PTCH SPAN CANTILEVER OVERHANG BRACING NOTES UNIT TOTAL /C LM B/C LIVIII LEFT RIGHT LEFT I RIGHT I # ROWS PRICE PRICE Al 13 0.0.00 5.0.00 00 -00 6 --- 2X4 2X4 02 -00 -0 02 00 00 0 P 2 5.0.00 0.0.00 6 -00 -00 2X4 2X4 02 -00 -0 02 -00 00 0 6 5.0.00 3 00 -004 2.5.00 02 -00 -0 02 - 00 -00 0 DELIVER $60.00 -- SUB-TOTALF $1,459.45 JOBSITE PHONE # GR AND TOTA I $1,459.451 6 -2 -0 -0 6 -9 -14 13 -0 -0 2 -0 -0 6 -9 -14 6 -2 -2 5.00 F1 2 D 13 1 Jo 6.200s 19 -2 -2 6 -2 -2 8 -10 -10 17 -1 -6 8 -10 -10 8 -2 -13 Plate Offsets ( X Y) [B 0 2 5 Edge] [C 0 3 0 0 3 4] [E 0 3 0 0 3 41 [F 0 -2 -5 Edge] [KO-4-0.0-3 0 -3 1) 070- 4-0,0-3-01 _ LOADING (psf) SPACING 2 -0-0 CSI TC 0.51 DEFL Vert(LL) in (loc) I /defl L/d -0.15 H -1 >999 360 TCLL 35.0 TCDL 7.0 Plates Increase Lumber Increase 1.15 1.15 BC 0.46 Vert(TL) -0.32 B -1 >964 240 BCLL 0.0 Rep Stress Incr YES WB 0.41 Horz(TL) Wind(LL) 0.09 F n/a Na 0.06 H -1 >999 240 BCDL 7.0 Code IRC2003/TP12002 (Matrix) LUMBER NOTES TOP CHORD 2 X 4 SPF 165OF 1.5E 1) Unbalanced roof live loads have been BOT CHORD 2 X 4 SPF 1650F 1.5E considered for this design. WEBS 2 X 4 SPF Stud /Std 2) Wind: ASCE 7 -02; 90mph; h =25ft; TCDL= 4.2psf; BCDL= 4.2psf; Category II; Exp BRACING C; enclosed; MWFRS gable end zone; TOP CHORD cantilever left and right exposed ; Lumber Structural wood sheathing directly applied or DOL =1.33 plate grip DOL =1.33. 3 -11 -13 oc purlins. 3) This truss has been designed for a 10.0 psf BOT CHORD bottom chord live load nonconcurrent with any Rigid ceiling directly applied or 10 -0 -0 oc bracing. other live loads. 4) Provide mechanical connection (by others) of REACTIONS (lb/size) truss to bearing plate capable of withstanding B = 1444/0 -5 -8 250 lb uplift at joint B and 250 lb uplift at joint F. F = 1444/0 -5 -8 5) This truss is designed in accordance with the Max Horz 2003 International Residential Code sections B = 74(load case 5) R502.11.1 and R802.10.2 and referenced Max Uplift standard ANSI/TPI 1. B = - 250(load case 3) F = - 250(load case 4) LOAD CASE(S) FORCES (lb) Standard Maximum Compression/Maximum Tension TOP CHORD A -B = 0/65 B -C = - 2446/302 C -D = - 2114/288 D -E = - 2114/288 E -F = - 2446/302 F -G = 0/65 BOT CHORD B -1 = - 215/2145 H -1 = - 94/1468 F -H = - 207/2145 WEBS C -1 = - 521/153 D -1 = - 581682 26 -0 -0 28 -0 -0 � 6 -9 -14 2 -0 -0 Scale = 1:49.7 8 -10 -10 PLATES GRIP M1120 197/144 Weight: 90 lb I� 0 D -H = - 581682 E -H = - 521/153 F Job Truss TAWpe Qty Ply M ERS - SMITH REMODEL 801170 -7 Al GE FINK 2 1 Plates Increase 1.15 TC 0.33 Vert(LL) -0.05 Q nlr 120 Jab Reference (optional) oiv- -co I k-mnv rm1L o), IU/ MU PHLLJ, IU 634UL -2 -0 -0 2 -0 -0 13 -0 -0 13 -0 -0 5.00 F1 2 o� 26 -0 -0 26 -0 -0 Iq 0 LOADING (psf) = 0/64 SPACING 2 -0 -0 CSI DEFL in (loc) I /deft L/d PLATES GRIP TCLL 35.0 Z = Plates Increase 1.15 TC 0.33 Vert(LL) -0.05 Q nlr 120 M1120 197/144 TCDL 7.0 199(loadcase 1) Lumber Increase 1.15 BC 0.09 Vert(TL) -0.07 Q n/r 120 N -O BCLL 0.0 O -P Rep Stress Incr YES WB 0.10 Horz(TL) 0.00 P n/a n/a AA -AB BCDL 7.0 Z -AA Code IRC2003/TP12002 (Matrix) = 0 /80 X -Y = 0/79 W -X Weight: 104 lb LUMBER TOP CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD 2 X 4 SPF 1650F 1.5E OTHERS 2 X 4 SPF Stud /Std BRACING TOP CHORD Structural wood sheathing directly applied or 6 -0 -0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Ib/size) B = P = W = X = Y = Z = AA = AB = V = U = T = S = R = Max Horz B = Max Uplift B = P = X = Y = Z = AA = AB = V = U = T = S = R = Max Grav B = 375/26 -0 -0 375/26 -0 -0 181/26 -0 -0 197/26 -0 -0 199/26 -0 -0 193/26 -0 -0 202/26 -0 -0 189/26 -0 -0 197/26 -0 -0 199/26 -0 -0 193/26 -0 -0 202/26 -0 -0 189/26 -0 -0 74(load case 5) - 122(load case 3) - 128(load case 4) - 33(load case 5) - 40(load case 3) - 33(load case 5) - 53(load case 3) - 26(load case 4) - 32(load case 6) 41 (load case 4) - 33(load case 6) - 53(load case 4) - 26(load case 3) 375(loadcase 1) Max Grav = 0/64 P = 375(loadcase 1) W = 181 (load case 1) X = 205(load case 9) Y = 199(loadcase 1) Z = 193(load case 9) AA = 202(loadcase 1) AB = 190(load case 9) V = 205(load case 10) U = 199(loadcase 1) T = 193(load case 10) S = 202(loadcase 1) R = 190(load case 10) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A -B = 0/64 B-C = -73/33 C -D = -46/50 D -E = -45/65 E -F = -5/69 F -G = 45/88 G -H = - 51/109 H -1 = - 51/129 I -J = - 51/128 J -K = - 51/103 K -L = -45/73 L -M = -5/46 M -N = -45/40 N -O = -46/26 O -P = -73/33 P -Q = 0/64 BOTCHORD B -AB = 0 /80 AA -AB = 0 /80 Z -AA = 0 /80 Y -Z = 0 /80 X -Y = 0/79 W -X = 0/79 V -W = 0/79 a.ZUU s Feb zi zuuO MI I eK InaustrIes, Inc. vvea Jan 31 1 U:3y:oo LUU I rage I 26 -0 -0 28 -0 -0 13 -0 -0 2 -0 -0 Scale = 1:49.7 BOT CHORD U -V = 0/79 T -U = 0 /80 S -T = 0/80 R -S = 0/80 P -R = 0/80 WEBS I -W = -154/0 H -X = - 176/51 G -Y = - 170/56 F -Z = - 169/52 D -AA = - 164/58 C -AB = - 185/55 J -V = - 176/49 K -U = - 170/56 L -T = - 169/52 N -S = - 164/58 O -R = - 185/55 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 122 lb uplift at joint B, 128 lb uplift at joint P, 33 to uplift at joint X, 40 to uplift at joint Y, 33 lb uplift at joint Z, 53 lb uplift at joint AA, 26 lb uplift at joint AB, 32 lb uplift at joint V, 41 lb uplift at joint U, 33 lb uplift at joint T, 53 lb uplift at joint S and 26 lb uplift at joint R. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7 -02; 90mph; h =25ft; TCDL= 4.2psf; BCDL= 4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail' 4) This truss has been designed for a 10.0 psf bottom chard live load nonconcurrent with any other live loads. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2 -0 -0 oc. Job Truss T pe Qty Ply MD ERS -SMITH REMODEL 801170 -7 B1 CATHEDRAL 6 1 >545 BMC WEST (IDAHO FALLS), IDAHO - FALLS 83402 0.22 F n/a c inn_ Job Reference o tional -2 -0 -0 5 -9 -0 11 -6 -0 17 -3 -0 1 23 -0 -0 25 -0 -0 2 -0 -0 5 -9 -0 5 -9 -0 5 -9 -0 5 -9 -0 2 -0 -0 Scale = 1:45.5 n 2.50,12 4 -0 -12 4 -0 -12 LOADING (psf) TCLL 35.0 TCDL 7.0 BCLL 0.0 BCDL 7.0 LUMBER TOP CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD 2 X 4 SPF 165OF 1.5E WEBS 2 X 4 SPF Stud/Std *Except* W2 2 X 4 SPF 1650F 1.5E BRACING TOP CHORD Structural wood sheathing directly applied or 3 -3 -11 oc purlins. BOTCHORD Rigid ceiling directly applied or 10 -0 -0 oc bracing. REACTIONS (lb /size) B = 1297/0 -5-8 F = 1297/0 -5 -8 Max Horz B = 68(load case 5) Max Uplift B = -231 (load case 3) F = -231 (load case 4) FORCES (lb) Maximum Compression/Maximum Tension TOP CHORD A-B = 0/65 B -C = - 2154/235 C -D = - 1801/246 D -E = - 3307/330 E -F = - 3801/420 F -G = 0/62 BOT CHORD B -J = - 145/1886 I -J = - 178/1876 H -1 = - 10211549 F -H = - 336/3460 WEBS C-J = 0/129 C -1 = - 471/113 D -I = - 82/290 D -H = - 114/1934 E -H = - 519/174 8-1-8 15 -4 -0 4 -0 -12 7 -2 -8 CSI DEFL in (loc) I /deft TC 0.49 Vert(LL) -0.30 H -1 >910 BC 0.66 Vert(TL) -0.50 H -1 >545 WB 0.31 Horz(TL) 0.22 F n/a (Matrix) Wind(LL) 0.11 H -1 >999 WEBS GJ = 0/129 C-1 = - 471/113 D-I = - 821290 D -H = - 114/1934 E-H = - 519/174 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7 -02; 90mph; h =25ft; TCDL= 4.2psf; BCDL= 4.2psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; Lumber DOL =1.33 plate grip DOL =1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) Bearing at joint(s) F considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 231 Ito uplift at joint B and 231 lb uplift at joint F. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 7 -8 -0 Ud PLATES GRIP 360 M1120 197/144 240 n/a 240 Weight: 82 lb t I� SPACING 2 -0-0 Plates Increase 1.15 Lumber Increase 1.15 Rep Stress Incr YES Code IRC2003/TPI2002